The formula that the Heat Index function uses to compute heat index is as follows:
Heat Index = ( -42.379 + (2.04901523 * T) + (10.14333127 * R)
- (0.22475541 * TR) - (6.83783e-3 * TT) - (5.481717e-2 * RR)
+ (1.22874e-3 * TTR) + (8.5282e-4 * TRR) - (1.99e-6 * TTRR) )
where:
- T = Air temperature
- R = Relative humidity
For more information about how this function works, see the Heat Index raster function.
The referenced raster dataset for the raster object is temporary. To make it permanent, you can call the raster object's save method.
Syntaxe
HeatIndex (temperature_raster, relative_humidity_raster, {temperature_unit}, {heat_index_unit})
Paramètre | Explication | Type de données |
temperature_raster | Raster monocanal où les valeurs de pixel représentent la température de l’air ambiant. | Raster |
relative_humidity_raster | A single-band raster where pixel values represent relative humidity as a percentage value between 0 and 100. | Raster |
temperature_unit | Unité de mesure associée au raster de température en entrée. Les unités disponibles en entrée sont Celsius, Fahrenheit et Kelvin. (La valeur par défaut est Fahrenheit) | String |
heat_index_unit | Unité de mesure associée au raster en sortie. Les unités disponibles en sortie sont Celsius, Fahrenheit et Kelvin. (La valeur par défaut est Fahrenheit) | String |
Type de données | Explication |
Raster | The output raster. |