Key | Value |
---|---|
Name | UPDM_UtilityNetwork.geodatabase |
Workspace Type | Local Database |
Workspace Factory | Sqlite |
Geodatabase Release | 3.0.0 |
Date Exported | 2024-05-25 |
Path |
Key | Value |
---|---|
Name | main.UtilityNetwork |
Dataset Type | FeatureDataset |
Feature Dataset | |
Dataset ID | |
# of Children | 71 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max |
Key | Value |
---|---|
Name | main.StructureBoundary |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 38 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Boundary |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {009A3FE1-8031-4BD9-96E2-734FE87B5697} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Boundary feature class represents features whose outline should be display on a map view or container view. Structure boundaries can contain structure edges, structure junctions, devices, lines, assemblies, and junctions. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of features. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | The discriminator field with a subtype specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | The indicator of the type of utility network association to which the station structure feature participates. | |
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the Utility Network managed subnetwork that the station structure is associated too. | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. This is the primary key value for relationships to child tables. | ||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date when the construction of the structure boundary feature was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date when the structure boundary feature was put into production. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
stationname | Station Name | String | True | 0 | 0 | 30 | True | False | The name used to uniquely identify and reference this facility. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the station structure. In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the station structure. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The text value indicating the life cycle state of the structure boundary. Coded Value Domain: Pipeline_LifeCycle_Status | |
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the record. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides and assessment of the spatial accuracy of the coordinates of the features geometry when the feature is inserted into the geodatabase. | |||
structureunits | Structure Units | Short Integer | True | 0 | 0 | 2 | True | False | The units of measurement used to define the structure height, length and width. | |||
coverunits | Cover Units | Short Integer | True | 0 | 0 | 2 | True | False | The units of measurement used to define the roof distance to surface, width, and length. | |||
pipelineoperator | Pipeline Operator | String | True | 0 | 0 | 30 | True | False | The name of the external organization that is providing liquid or gas to the pipeline facility. | |||
structureheight | Structure Height | Double | True | 0 | 0 | 8 | True | False | The vertical linear distance from ground level to the top of the structure roof. | |||
structurelength | Structure Length | Double | True | 0 | 0 | 8 | True | False | The horizontal linear distance at ground level along one edge of the structure. | |||
structurewidth | Structure Width | Double | True | 0 | 0 | 8 | True | False | The horizontal linear distance at ground level along the edge perpendicular to the edge used for the structurelength measurement. | |||
material | Material | String | True | 0 | 0 | 2 | True | False | The primary material used in the construction of the station structure facility. | |||
coverdepth | Cover Depth | Double | True | 0 | 0 | 8 | True | False | The vertical distance below the ground to the roof of the vault. | |||
coverlength | Cover Length | Double | True | 0 | 0 | 8 | True | False | The vertical linear distance measured along one edge of the roof of the vault. | |||
coverwidth | Cover Width | Double | True | 0 | 0 | 8 | True | False | The vertical linear distance measure along the roof edge perpendicular to the roof edge used for the COVERlength measurement. | |||
ventedindicator | Vented Indicator | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the underground facility is vented to the atmosphere. | |||
contractor | Contractor | String | True | 0 | 0 | 50 | True | False | The name of the company hired to construct the station structure. | |||
pipelinestation | Pipeline Station | Double | True | 0 | 0 | 8 | True | False | The value is the measurement indicating where the station structure is located along the pipeline operators route. This column is only used when an external system requires that the linear referencing data be stored as a columnar attribute instead of embedded within the geometry. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping/asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the structure boundary feature was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the structure boundary feature. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this structure boundary feature. | |||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | A description of the location of the record. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
st_area(SHAPE) | SHAPE_Area | Double | Area | True | 0 | 0 | 0 | False | True | |||
st_perimeter(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_38_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_40 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureBoundary_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Pipe Station | 1 | The subtype feature layer Pipeline Station Structure describes the above ground structure used to house oil and gas facilities such as compressor stations, pump stations, town border stations and regulator stations. |
Pipe Vault | 2 | The subtype feature layer Pipeline Vault Boundary describes the below ground structure used to house oil and gas facilities such as compressor stations, pump stations, town border stations and regulator stations. |
Pipe Processing Facility | 3 | The subtype feature layer Pipeline Processing Facility describes the above ground structure used to process the raw commodity. |
Cathodic | 4 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 12.6 | 1 | StructureBoundary-GenerateIDs | Generate IDs for StructureBoundary using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:00 | // Assigned To: StructureBoundary // Type: Calculation // Name: StructureBoundary-GenerateIDs // Description: Generate IDs for StructureBoundary using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureLine-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineJunction-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Pp-Sttn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SB_Pp_Sttn_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "Pp-VLT", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SB_Pp_VLT_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "Pp-Prcssng-FAC", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SB_Pp_Prcssng_FAC_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Cthdc", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SB_Cthdc_4_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.P_EngineeringNetwork |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 429 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Engineering Network |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {02C19FEC-3B1D-4F44-9050-E2678D67296A} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_EngineeringNetwork is for storing pipeline routes defined using the Engineering Stationing Measure method of managing linear referencing information. If the Engineering Stationing method for managing linear referencing information is not used, then this feature class is not required for the ArcGIS Pipeline Referencing tools. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
routeid | Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID for the route. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
routename | Route Name | String | True | 0 | 0 | 100 | True | False | The user defined name for the route. This is an optional value. | |||
lineid | LineID | String | True | 0 | 0 | 38 | True | False | The unique ID for a collection of contiguous route segments. This is often referred to as a line loop in the pipeline industry. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
linename | Line Name | String | True | 0 | 0 | 100 | True | False | The user-defined name for the line loop. This is an optional value. | |||
orderid | OrderID | Long Integer | True | 0 | 0 | 4 | True | False | The sequence number of the route segment within a line loop. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_96 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_EngineeringNetwork_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_ExposedPipeInspect__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 462 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_ExposedPipeInspect |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_ExposedPipeInspect__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {089AD835-E7B2-413E-9290-E7902E6174F3} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_Redline |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 454 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Redline |
OID Field | OBJECTID |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | Shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {08F6A8CB-5013-41F7-8706-CF56F7D090D7} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_Redline is for storing desired modifications to the linear referencing network. The redline feature can be thought of as a placeholder for a future route editing operation. It is used as a markup feature so that LRS event editors don't have to be LRS route editors. This feature class is a core schema component for the ArcGIS Pipeline Referencing tools. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
effectivedate | Effective Date | Date | True | 0 | 0 | 8 | True | False | Date the reoute changes becomes effective. This date will be applied to events affected by the change. | |||
networkid | NetworkID | Short Integer | True | 0 | 0 | 2 | True | False | The unique ID for the ALRP network in which each route participates. | |||
routeid | Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID for the route. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
activitytype | Activity Type | Short Integer | True | 0 | 0 | 2 | True | False | Type of change being made, for example, Realign Route, Extend Route, and so on. | |||
routename | Route Name | String | True | 0 | 0 | 100 | True | False | The user defined name for the route. This is an optional value. | |||
frommeasure | From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network ROUTEID specified route where the start of the linear event is located. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
tomeasure | To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the ROUTEID specified route where the completion of the linear event is located. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
Shape | SHAPE | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(Shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_121 | True | True | globalid |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__P_Redline_Shape | True | True | Shape |
Key | Value |
---|---|
Name | main.P_LeakRepairs |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 443 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Leak Repair |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {0A60116E-4181-430E-BAD6-1C00C53CBF53} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The line feature class P_LeakRepair describes the extent of pipe that an organization has decided to fix in response to an identified leak. This often results in the replacement of a section of pipe. Therefore, this record is modeled as a line feature to allow for the extent of repair to be captured. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
leakrepairtype | Leak Repair Type | String | True | Pipeline_Leak_Repair_Type | 0 | 0 | 30 | True | False | The type of repair made to resolve the leak. | ||
repairedby | Repaired By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who was responsible for the repair to the pipe system and compiled the information for this record. | |||
daterepaired | Date Repaired | Date | True | 0 | 0 | 8 | True | False | The date and time the leak repair was completed. | |||
damagetype | Damage Type | String | True | Pipeline_Excav_Damage_Type | 0 | 0 | 30 | True | False | The type of damage to the pipe system asset that resulted in the leak. | ||
leaklocation | Leak Location | String | True | Pipeline_Leak_Location | 0 | 0 | 30 | True | False | The location in the pipe system of the origination of the leak. | ||
workperformed | Work Performed | String | True | Pipeline_Leak_Work_Performed | 0 | 0 | 30 | True | False | The type of work performed to repair the identified leak. | ||
soilatpipedepth | Soil at Pipe Depth | String | True | Pipeline_Soil_Type | 0 | 0 | 20 | True | False | The type of predominant soil at the depth of the buried asset. | ||
surfacetype | Surface Type | String | True | Pipeline_Surface_Type | 0 | 0 | 20 | True | False | The predominant surface type at the location where the leak repair occurred. | ||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The end-to-end distance of the record. | |||
gasleak_globalid | GasLeak_GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The GasLeak feature class globalid value of the leak feature that was inspected. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_443_GasLeak_ | False | True | gasleak_globalid |
UUID_110 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_LeakRepairs_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_HighConsequenceArea |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 433 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | High Consequence Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {0F2D671F-D5CF-424F-A06B-007947B35020} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygon feature class P_HighConsequenceArea describes the extent of the HCA for the pipe segment. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 15 | True | False | The text value indicating the life cycle state of the object. Valid values are conceptual, proposed, active, inactive, and unknown. | ||
hcatype | Area Type | String | True | Pipeline_HCA_Area_Type | 0 | 0 | 25 | True | False | The text value indicating the type of high consequence area. Valid values are 20 or more persons, DOT Class 3, DOT Class 4, and limited mobility. | ||
consequenceclass | Consequence Class | Short Integer | True | Pipeline_DOT_Class_Type | 0 | 0 | 2 | True | False | The text value indicating the class type designation of HCA. Valid values are 1, 2, 3, and 4. | ||
comments | Comments | String | True | 0 | 0 | 255 | True | False | The nonstructured information about the HCA. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_100 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_HighConsequenceArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.UPDMAssembly_P_StatVisInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 483 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineAssembly |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMAssembly_GlobalID |
Destination Name | main.P_StationVisualInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_StationVisualInspection |
Backward Path Label | PipelineAssembly |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {157872A4-846D-4712-8B63-224EE509E16F} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Compressor Station | 0 | 9999 | 0 | 9999 | |
2 | Pump Station | 0 | 9999 | 0 | 9999 | |
3 | Regulator Station | 0 | 9999 | 0 | 9999 | |
4 | Town Border Station | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_TestPressureRange |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 458 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Test Pressure Range |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {1B355DFD-58AC-4E9A-9EC3-0ADB3BCD4BAE} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_TestPressureRange describes the length or range of pressure test performed on the pipe system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
pressuretest | Pressure Test | Double | True | 0 | 0 | 8 | True | False | The pressure used for the test. | |||
mindesignpressure | Minimum Design Pressure | Double | True | 0 | 0 | 8 | True | False | The minimum design pressure of the pressure test for the pipe segment. | |||
minadjustedpressure | Minimum Adjusted Pressure | Double | True | 0 | 0 | 8 | True | False | The minimum adjusted pressure of the pressure test for the pipe segment. | |||
unitofmeasure | Unit of Measure | Short Integer | True | Units_for_Pressure | 0 | 0 | 2 | True | False | The unit of measure defining test pressure. | ||
pretest | PreTest | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The text value indicating whether a pretest was performed. Valid values are yes and no. | |
testdate | Test Date | Date | True | 0 | 0 | 8 | True | False | The date and time the test was performed. | |||
testmedium | Test Medium | String | True | Pipeline_Pressure_Test_Medium | 0 | 0 | 25 | True | False | The medium used for the pressure test. Valid values are air, gas, nitrogen, inert gas, water, and other. | ||
testname | Test Name | String | True | 0 | 0 | 50 | True | False | The name of the test. | |||
testtype | Test Type | String | True | Pipeline_Pressure_Test_Type | 0 | 0 | 25 | True | False | The type of pressure test performed. Valid values are strength, spike, yield, uprating, and other. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_125 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_TestPressureRange_shape | True | True | shape |
Key | Value |
---|---|
Name | main.UPDMDevice_P_CPTestReading |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 485 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineDevice |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMDevice_GlobalID |
Destination Name | main.P_CPTestPointReading |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CPTestPointReading |
Backward Path Label | PipelineDevice |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {1C369EDF-09FE-4324-9CCA-3022BFE53937} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Test Point | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_ILISurveyReadings |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 438 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | ILI Survey Readings |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {2273A9AF-5DFF-4009-9701-AF1F62C4C415} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_ILISurveyReadings describes information in the pipeline system as detected from inline inspection runs of a pigging device. Typical surveys include information on welds, branch connections, valves, wall thickness changes caused by corrosion, and other imperfections in the pipe. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
surveytype | ILI Survey Type | String | True | Pipeline_ILI_Survey_Type | 0 | 0 | 30 | True | False | The text value indicating the type of anomaly detected by the ILI run. Valid values are Metal Loss, Crack, Mechanical Damage, Material Defect, and ILI Other. | ||
featurecode | Feature Count | Long Integer | True | 0 | 0 | 4 | True | False | The feature code designation for the ILI reading. | |||
reldistance | Relative Distance | Double | True | 0 | 0 | 8 | True | False | The relative distance of the feature detected from the ILI run. | |||
rundistance | Run Distance | Double | True | 0 | 0 | 8 | True | False | The run distance recorded by the pigging device for the feature detected from inline inspection. | |||
defectorientation | Defect Orientation | Long Integer | True | 0 | 0 | 4 | True | False | The angular position of the anomaly feature reading. | |||
depth | Depth | Double | True | 0 | 0 | 8 | True | False | The distance below the ground cover where the record is buried. | |||
depthunits | Depth Units | Short Integer | True | Units_for_Depth | 0 | 0 | 2 | True | False | The unit of measure used to define the depth of the record. | ||
anomlength | Length | Double | True | 0 | 0 | 8 | True | False | ||||
lengthunits | Length Units | Short Integer | True | Units_for_Diameter | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | ||
longseamorientation | Long Seam Orientation | Long Integer | True | 0 | 0 | 4 | True | False | The angular position of the longitudinal seam detected by the pigging device. | |||
wallthickness | Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturer's defined thickness of the pipe wall. | |||
width | Width | Double | True | 0 | 0 | 8 | True | False | The width of the anomaly feature reading. | |||
widthunits | Width Units | Short Integer | True | Units_for_Diameter | 0 | 0 | 2 | True | False | The unit of measurement of the width of the anomaly. | ||
deepestpointdegrees | Deepest Point Degrees | Long Integer | True | 0 | 0 | 4 | True | False | The angular position of the deepest point at the anomaly feature reading. | |||
clusterno | Cluster Number | Long Integer | True | 0 | 0 | 4 | True | False | The numeric count of the anomaly features. | |||
clusterrpr | Cluster RPR | Double | True | 0 | 0 | 8 | True | False | The rupture pressure ratio at the anomaly features. | |||
pitrpr | Pit RPR | Double | True | 0 | 0 | 8 | True | False | The rupture pressure ratio as determined by the pigging device. | |||
remainingwt | Remaining WT | Double | True | 0 | 0 | 8 | True | False | The pipe wall thickness remaining at the anomaly feature reading. | |||
rstrengthrpr | R Strength RPR | Double | True | 0 | 0 | 8 | True | False | ||||
intextindicator | Internal External Indicator | String | True | Pipeline_ILI_Survey_Int_Ext_Indicator | 0 | 0 | 10 | True | False | The text value indicating if the anomaly position is internal or external. Valid values are internal, external, or unknown. | ||
usagmdistance | US AGM Distance | Double | True | 0 | 0 | 8 | True | False | The distance from current anomaly to the nearest AGM upstream on the pipeline. | |||
usagmreference | US AGM Reference | String | True | 0 | 0 | 50 | True | False | The reference identifier of the nearest AGM to the anomaly upstream on the pipeline. | |||
dsagmdistance | US AGM Distance | Double | True | 0 | 0 | 8 | True | False | The distance from the current anomaly to the nearest AGM downstream on the pipeline. | |||
dsagmreference | DS AGM Reference | String | True | 0 | 0 | 50 | True | False | The reference identifier of the nearest AGM to the anomaly downstream on the pipeline. | |||
erf | ERF | Double | True | 0 | 0 | 8 | True | False | The pipe estimated repair factor (ERF) at the anomaly. | |||
bpr | BPR | Double | True | 0 | 0 | 8 | True | False | The pipe back pressure ratio at the anomaly. | |||
longitude | Longitude | Double | True | 0 | 0 | 8 | True | False | The longitude reading at the anomaly. | |||
latitude | Latitude | Double | True | 0 | 0 | 8 | True | False | The latitude reading at the anomaly. | |||
ilisurveygroup_globalid | ILI Survey Group GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The ILI survey group feature class column containing the matching primary key value for relationships to associated components. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_438_ILISURVE | False | True | ilisurveygroup_globalid |
UUID_105 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ILISurveyReadings_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_GasLeak_P_LeakRepairs |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 464 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_GasLeak |
Origin Primary Key | GlobalID |
Origin Foreign Key | GasLeak_GlobalID |
Destination Name | main.P_LeakRepairs |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_LeakRepairs |
Backward Path Label | P_GasLeak |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {2469AF0B-DFF3-44E0-803E-A7C1E05A9DC6} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Construction | 0 | 9999 | 0 | 9999 | |
2 | Corrosion | 0 | 9999 | 0 | 9999 | |
3 | Equipment | 0 | 9999 | 0 | 9999 | |
4 | Excavation Damage | 0 | 9999 | 0 | 9999 | |
5 | Incorrect Operations | 0 | 9999 | 0 | 9999 | |
6 | Manufacturing | 0 | 9999 | 0 | 9999 | |
7 | Material or Welds | 0 | 9999 | 0 | 9999 | |
8 | Natural Forces | 0 | 9999 | 0 | 9999 | |
9 | Other | 0 | 9999 | 0 | 9999 | |
10 | Other Outside Force Damage | 0 | 9999 | 0 | 9999 | |
11 | Unknown | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_LeakRepairs__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 471 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_LeakRepairs |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_LeakRepairs__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {2EBFE3AB-D45E-4749-BFF5-136C00467356} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.StructureLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 37 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {36B54C1E-8110-4DF7-9885-E4DF5DF0D4F7} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Line contain lines which carry a resource. Structure lines participating as containers can contain other structure lines. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of records. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | The discriminator field with a subtype specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | An indicator of the type of utility network association to which the record participates. | |
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the Utility Network managed subnetwork that the record participates in. | |
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
filltype | Fill Type | Short Integer | True | 0 | 0 | 2 | True | False | The type of material used to fill the pipe casing. | |||
ventedindicator | Vented Indicator | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the underground linear feature such as a pipe casing is vented to the atmosphere. | |||
insertindicator | Insert Indicator | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the pipe casing was formerly a retired pipe segment and a new pipe segment has been inserted into the retired pipeline. | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the record was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the record was put into production. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the record. In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the record. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The value indicating the life cycle state of the record. | |
casingdiameter | Casing Diameter | Double | True | Pipeline_Casing_Diameter | 0 | 0 | 8 | True | False | The generalized edge to edge nominal measured length of a straight line through the center of the record. | ||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The end-to-end distance of the record. | |||
lengthsource | Length Source | Short Integer | True | 0 | 0 | 2 | True | False | The method used to determine the MEASURED length value. | |||
wallthickness | Wall Thickness | Double | True | Pipeline_Pipe_Wall_Thickness-Transmission | 0 | 0 | 8 | True | False | |||
material | Material | String | True | Pipeline_ASTM_Transmission_Pipe_Material | 0 | 0 | 2 | True | False | The primary material used in the construction of the record. | ||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the record. | |||
coatingtype | Coating Type | String | True | Pipeline_Coating_Type | 0 | 0 | 30 | True | False | The type of material applied to the exterior of the record. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | |||
diameterunits | Diameter Units | Short Integer | True | Units_for_Diameter | 0 | 0 | 2 | True | False | The unit of measure defining the diameter and diameter2 fields. | ||
lengthunits | Length Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | |||
endconnection | End Connection | String | True | 0 | 0 | 15 | True | False | The type of connection applied to the end of the pipe casing to seal the pipe. | |||
filldate | Fill Date | Date | True | 0 | 0 | 8 | True | False | The date when the pipe casing was filled with material. | |||
fillcapacity | Fill Capacity | Long Integer | True | 0 | 0 | 4 | True | False | The volume of maerial required to fill the interior of the pipe casing. | |||
protectiontype | Protection Type | String | True | 0 | 0 | 20 | True | False | The type of cathodic protection used for the pipe casing. | |||
reason | Reason | String | True | 0 | 0 | 20 | True | False | The reason for the installation of the pipe casing to protect the record. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the record was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the record. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this record. | |||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | A description of the location of the record. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_37_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_39 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Pipe Casing | 1 | The subtype feature layer Pipeline Pipe Casing describes the pipeline facility used to encase a portion of a pipeline. |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
3 | 12.6 | 1 | StructureLine-GenerateIDs | Generate IDs for StructureLine using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:04 | // Assigned To: StructureLine // Type: Calculation // Name: StructureLine-GenerateIDs // Description: Generate IDs for StructureLine using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureBoundary-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineJunction-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Pp-Csng", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SL_Pp_Csng_1_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.UPDMAssembly_P_ReliefValveInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 482 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineAssembly |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMAssembly_GlobalID |
Destination Name | main.P_ReliefValveInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_ReliefValveInspection |
Backward Path Label | PipelineAssembly |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {48F44E13-0EF1-4FC5-B352-6F180197F8F6} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Valve Assembly | 0 | 9999 | 0 | 9999 | |
2 | Compressor Station | 0 | 9999 | 0 | 9999 | |
3 | Fitting Assembly | 0 | 9999 | 0 | 9999 | |
4 | Meter Setting | 0 | 9999 | 0 | 9999 | |
5 | Pigging Structure | 0 | 9999 | 0 | 9999 | |
6 | Pump Station | 0 | 9999 | 0 | 9999 | |
7 | Regulator Station | 0 | 9999 | 0 | 9999 | |
8 | Rural Tap | 0 | 9999 | 0 | 9999 | |
9 | Town Border Station | 0 | 9999 | 0 | 9999 | |
10 | Unknown | 0 | 9999 | 0 | 9999 | |
11 | Wellhead | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.UPDMJunction_P_CPBondInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 489 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineJunction |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMJunction_GlobalID |
Destination Name | main.P_CPBondInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CPBondInspection |
Backward Path Label | PipelineJunction |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {4A7B3BE7-FD6C-486C-813E-C17C3993AFE4} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Wire Junction | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_PipeJobSeparator |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 452 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Pipe Job Separator |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {4DEA2C3A-E2BF-4D1F-A313-0AEFBC11C543} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_PipeJobSeparator describes the location along a pipe segment in the pipe system where one capital project terminated and another capital project started. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_119 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_PipeJobSeparator_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_ExcavationDamage |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 430 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Excavation Damage |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {4FE235E6-B751-472B-A49C-71559D0EC48C} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_ExcavationDamage represents the location where a component of the pipe system has been damaged by the actions of an external entity. This feature class stores the information, photos, and sketches captured as part of the reporting process to document the incident. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
datedamaged | Date Damaged | Date | True | 0 | 0 | 8 | True | False | The date the incident causing the damage occurred. | |||
responsiblepartyname | Responsible Party Name | String | True | 0 | 0 | 50 | True | False | The name of the company or person responsible for causing the damage to the pipe system. | |||
responsiblecontactname | Responsible Contact Name | String | True | 0 | 0 | 50 | True | False | The name of the person to contact of the party that is responsible for causing the damage to the pipe system. | |||
responsiblepartyaddress | Responsible Party Address | String | True | 0 | 0 | 50 | True | False | The street address of the company or person responsible for causing the damage to the pipe system. | |||
responsiblepartycity | Responsible Party City | String | True | 0 | 0 | 50 | True | False | The city name of the responsible companys business location or persons residence location. | |||
responsiblepartystate | Responsible Party State | String | True | Pipeline_Region | 0 | 0 | 2 | True | False | The U.S. postal code abbreviation of the responsible companys business location or persons residence location. | ||
responsiblepartyphone | Responsible Party Phone | String | True | 0 | 0 | 20 | True | False | The telephone number of the responsible companys business or persons primary contact phone. | |||
responsiblepartytype | Responsible Party Type | String | True | Pipeline_Excav_Dam_Resp_Party_Type | 0 | 0 | 30 | True | False | The categorical group in which the responsible party would be classified. Valid values are Home Owner, Other Utility, Company, Contractor, Local Government, State Government, Federal Government, and Other. | ||
incidentlocationaddress | Incident Location Address | String | True | 0 | 0 | 50 | True | False | The approximate street address of where the damage occurred to the gas system. | |||
incidentlocationcity | Incident Location City | String | True | 0 | 0 | 50 | True | False | The name of the city where the damage occurred to the gas system. | |||
incidentlocationstate | Incident Location State | String | True | Pipeline_Region | 0 | 0 | 2 | True | False | The U.S. postal code abbreviation of the state where the damage occurred to the gas system. | ||
damagetype | Damage Type | String | True | Pipeline_Excav_Dam_Damage_Type | 0 | 0 | 25 | True | False | The type of damage to the gas system. | ||
damagedfacilitytype | Damaged Facility Type | String | True | Pipeline_Leak_Facility_Type | 0 | 0 | 30 | True | False | The type of gas component damaged by the excavation event. | ||
equipcausingdamage | Equipment Causing Damage | String | True | Pipeline_Excav_Equip_Causing_Damage | 0 | 0 | 20 | True | False | The type of equipment responsible for the excavation damage. | ||
worktype | Work Type | String | True | Pipeline_Excav_Dam_Work_Type | 0 | 0 | 30 | True | False | The type of work that was being performed when the excavation damage occurred. | ||
rootcause | Root Cause | String | True | Pipeline_Excav_Dam_Root_Cause | 0 | 0 | 30 | True | False | The underlying cause of the excavation damage. | ||
policereport | Police Report | Short Integer | True | Yes_No | 1 | 0 | 0 | 2 | True | False | A yes/no Boolean attribute indicating whether a police report was filed as part of the excavation damage incident. | |
remarks | Remarks | String | True | 0 | 0 | 250 | True | False | A text comment attribute to allow for additional information to be recorded. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_97 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ExcavationDamage_shape | True | True | shape |
Key | Value |
---|---|
Name | main.UPDMLine_P_IsoPipeInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 491 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineLine |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMLine_GlobalID |
Destination Name | main.P_IsolatedPipeInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_IsolatedPipeInspection |
Backward Path Label | P_PipelineLine |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {5322D87D-213E-41E9-B3D5-1511D4A24A4C} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Distribution Pipe | 0 | 9999 | 0 | 9999 | |
2 | Gathering Pipe | 0 | 9999 | 0 | 9999 | |
3 | Pressure Sensor Pipe | 0 | 9999 | 0 | 9999 | |
4 | Riser Pipe | 0 | 9999 | 0 | 9999 | |
5 | Service Pipe | 0 | 9999 | 0 | 9999 | |
6 | Station Pipe | 0 | 9999 | 0 | 9999 | |
7 | Storage Pipe | 0 | 9999 | 0 | 9999 | |
8 | Transmission Pipe | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.UPDMDevice_P_ValveInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 488 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineDevice |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMDevice_GlobalID |
Destination Name | main.P_ValveInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_ValveInspection |
Backward Path Label | PipelineDevice |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {541E6BEF-7A4F-4861-8DE9-8822F0EEDDB0} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Controllable Valve | 0 | 9999 | 0 | 9999 | |
2 | Flow Valve | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.PipelineAssembly |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 378 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Pipeline Assembly |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {54E12594-B448-456A-8CCC-BFA8125177FC} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Assembly feature class represents complex point features which contain other devices and lines. Like device features, assembly features are compact features but they differ in that assemblies contain other significant devices. Assemblies are useful to show a single symbol on the map yet model the internal features and their connections. Assemblies can contain devices, lines, and junctions. You can view the internal features of an assembly on the map or in the diagram view. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of features. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | A discriminator field with a subtype-specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | An indicator of the type of utility network association to which the device feature participates. | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. This is the primary key value for relationships to child tables. | ||
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
cpsubnetworkname | CP Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | The name of the cathodic protection tier subnetwork where the device is located. | ||
systemsubnetworkname | System Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | The name of the system zone tier subnetwork where the device is located. | ||
pressuresubnetworkname | Pressure Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | The name of the pressure zone tier subnetwork where the device is located. | ||
isolationsubnetworkname | Isolation Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | The name of the isolation zone tier subnetwork where the device is located. | ||
regulatorytype | Regulatory Type | Short Integer | True | Pipeline_Regulatory_Type | 0 | 0 | 0 | 2 | True | False | The value indicating the regulatory status of the excess flow valve feature. This is used by the Facility Reporting tools to differentiate between Distribution, Transmission, Offshore Transmission, Gathering, and Offshore Gathering pipe. | |
vault | Vault | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the regulator station is contained in a vault. | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the excess flow valve was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the excess flow valve was put into production. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
name | Name | String | True | 0 | 0 | 64 | True | False | The textual name used within the organization to refer to the record. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the excess flow valve In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the excess flow valve. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The text value indicating the life cycle state of the excess flow valve. | |
pipelineoperatornumber | Pipeline Operator Number | Short Integer | True | Pipeline_Pipeline_Operator_Number | 0 | 0 | 0 | 2 | True | False | The U.S. DOT-issued unique identifier. | |
supplier | Supplier | Short Integer | True | Pipeline_Supplier | 0 | 0 | 0 | 2 | True | False | The name of the organization responsible for supplying the commodity to the organization. | |
pressurerating | Pressure Rating | Double | True | 0 | 0 | 8 | True | False | The pressure rating at which the feature is qualified. | |||
mopin | MOP In | Double | True | 0 | 0 | 8 | True | False | The maximum operating pressure allowed to enter the feature. | |||
mopout | MOP Out | Double | True | 0 | 0 | 8 | True | False | The maximum operating pressure allowed to exit the feature. | |||
sopin | SOP In | Double | True | 0 | 0 | 8 | True | False | The standard operating pressure allowed to enter the feature. | |||
sopout | SOP Out | Double | True | 0 | 0 | 8 | True | False | The standard operating pressure allowed to exit the feature. | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | This value defines the angular degrees that the point symbol should be rotated. The purpose is to have the feature's display symbology automatically rotated to the angle defined in this attribute. | ||
prottype | Over Pressure Protection Type | Short Integer | True | 0 | 0 | 2 | True | False | The type of over pressure protection used in the feature. | |||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the excess flow valve. | |||
wallthickness | Pipe Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturer defined thickness of the exterior wall of the upstream excess flow valve orifice. | |||
manufacturer | Manufacturer | String | True | 0 | 0 | 5 | True | False | The organization that built the device. Coded Value Domain: Pipeline_ASTM_Manufacturer | |||
pipegrade | Pipe Grade | String | True | 0 | 0 | 2 | True | False | The classification of the characteristics of the material used for the feature. | |||
pipematerial | Pipe Material | String | True | 0 | 0 | 30 | True | False | The generic classification of the type of material used for the feature. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the features geometry when the feature is included in the geodatabase. | |||
diameter | Pipe Diameter | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the center of the upstream excess flow valve orifice. | |||
diameterunits | Diameter Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the diameter of the excess flow valve. | |||
lengthunits | Length Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | |||
pressureunits | Pressure Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the operating pressure. | |||
pressureratingunits | Pressure Rating Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the pressure rating. | |||
connectiontype | Connection Type | String | True | 0 | 0 | 30 | True | False | The type of connection between the wellhead and the pipe system. | |||
materialclass | Material Class | String | True | 0 | 0 | 20 | True | False | The American Petroleum Institute classification of the material used to construct the wellhead. | |||
odorizerindicator | Odorizer Indicator | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no value indicating whether the record odorizes the natural gas. | |||
bypassindicator | Bypass indicator | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no value indicating whether the record includes a bypass. | |||
pipelineoperator | Pipeline Operator | String | True | 0 | 0 | 50 | True | False | The name of the external organization that is providing liquid or gas to the pipeline facility. | |||
designcapacity | Design Capacity | Double | True | 0 | 0 | 8 | True | False | The maximum flow rate through the record. | |||
designcapacityunits | Design Capacity Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for volume flow for designcapacity. | |||
structurelength | Structure Length | Double | True | 0 | 0 | 8 | True | False | The horizontal linear distance at ground level along one edge of the structure. | |||
outletvalvetype | Outlet Valve Type | String | True | 0 | 0 | 30 | True | False | The type of outlet valve used in the wellhead construction. | |||
shutoffvalvediameter | Shutoff Valve Diameter | Double | True | 0 | 0 | 8 | True | False | The edge-to-edge nominal measurement length of a straight line through the center of the rural tap shutoff valve orifice. | |||
shutoffvalvetype | Shutoff Valve Type | String | True | 0 | 0 | 25 | True | False | The type of valve used in the rural tap for shutoff. | |||
tapdiameter | Tap Diameter | Double | True | 0 | 0 | 8 | True | False | The to-edge nominal measurement length of a straight line through the center of the rural tap inflow tap orifice. | |||
taptype | Tap Type | String | True | 0 | 0 | 20 | True | False | The type of tap used in the rural tap. | |||
totalpower | Total Power | Double | True | 0 | 0 | 8 | True | False | The summation of the power of all units in the compressor station. | |||
numberofengines | Number of Engines | Short Integer | True | 0 | 0 | 2 | True | False | The number of engines in the compressor station. | |||
numberofturbines | Number of Turbines | Short Integer | True | 0 | 0 | 2 | True | False | The number of turbines in the compressor station. | |||
numberofmotors | Number of Motors | Short Integer | True | 0 | 0 | 2 | True | False | The number of motors in the compressor station. | |||
numberofunits | Number of Units | Short Integer | True | 0 | 0 | 2 | True | False | The number of pumps in the pump station facility. | |||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsz | GPS Z | Double | True | 0 | 0 | 8 | True | False | The elevation coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the excess flow valve feature was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the excess flow valve feature. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this excess flow valve feature. | |||
servicesummaryid | Service Summary ID | GUID | True | 0 | 0 | 38 | True | False | The foreign key unique value used to relate the excess flow valve feature to the SERVICESSUMMARY feature class record with which it participates. | |||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each event record. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the event became active on the route. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the event was retired from the route. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The name of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the anomaly is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset feature. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point feature class. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting feature. This can be Coordinates, Feature/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the excess flow valve. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
commodity | Commodity | Short Integer | True | 0 | 0 | 2 | True | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_378_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
UUID_45 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__PipelineAssembly_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Compressor Station | 1 | The subtype feature layer Compressor Station describes the facility in the natural gas transmission pipeline portion of the pipe system responsible for increasing pressure in the downstream pipeline. A compressor station is composed of one or more compressors plus other supporting components such as cooling systems, valves, fittings, and station piping. |
Meter Setting | 2 | The subtype feature layer Meter Setting describes the facility in the pipe system that contains meters, regulators, and risers to monitor and record the volume and flow. |
Regulator Station | 3 | The subtype feature layer Regulator Station describes the facility within a pipeline that contains the regulators, valves, and piping to change the pressure of the fluid or gas in the pipe system. |
Rural Tap | 4 | The derived point feature layer RuralTap describes the facility on a transmission pipeline used to serve gas to rural residential and industrial customers. This facility is also commonly referred to as a farm tap. |
Town Border Station | 5 | The point derived feature layer Town Border Station describes the regulator station facility within a pipeline that is also the point of transfer between the transmission system and the distribution system. In distribution-only pipe systems, the town border station represents the source of gas. |
Wellhead | 6 | The point derived feature layer Wellhead connects a well to the pipe system. These components are used in the utility network as a source of the gas or liquid being transported through the pipe system. |
Pigging Structure | 7 | The point derived feature layer PiggingStructure describes the facilities that allow for the insertion or extraction of a pig sensor unit from the gas or fluid system. PiggingStructure represents both the launcher and receiver aspects of the pig structure. |
Fitting Assembly | 8 | The point derived feature layer FittingAssembly describes the facility within a pipeline that contains many fittings and devices within a small geographic area. |
Pump Station | 9 | The point derived feature layer Pump Station describes the facility within a pipeline that pressurizes the fluid in the pipe system. Pump stations are typically used in long distance transmission pipelines where additional pressurization is required to allow the fluid to continue its transport through the pipeline. |
Valve Assembly | 10 | |
Cathodic Assembly | 11 | |
Storage Facility | 12 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 12.6 | 1 | PipelineAssembly-GenerateIDs | Generate IDs for PipelineAssembly using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:11 | // Assigned To: PipelineAssembly // Type: Calculation // Name: PipelineAssembly-GenerateIDs // Description: Generate IDs for PipelineAssembly using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureBoundary-GenerateIDs // - StructureLine-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineJunction-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Cmprssr-Sttn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Cmprssr_Sttn_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "MTR-Sttng", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_MTR_Sttng_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "REG-Sttn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_REG_Sttn_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Rrl-Tp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Rrl_Tp_4_seq'); }else if (selector_value_txt == '5') { id_format = { 'prefix': "Twn-Brdr-Sttn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Twn_Brdr_Sttn_5_seq'); }else if (selector_value_txt == '6') { id_format = { 'prefix': "Wllhd", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Wllhd_6_seq'); }else if (selector_value_txt == '7') { id_format = { 'prefix': "Pggng-Strctr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Pggng_Strctr_7_seq'); }else if (selector_value_txt == '8') { id_format = { 'prefix': "Fttng-Assmbly", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Fttng_Assmbly_8_seq'); }else if (selector_value_txt == '9') { id_format = { 'prefix': "Pmp-Sttn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Pmp_Sttn_9_seq'); }else if (selector_value_txt == '10') { id_format = { 'prefix': "Vlv-Assmbly", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Vlv_Assmbly_10_seq'); }else if (selector_value_txt == '11') { id_format = { 'prefix': "Cthdc-Assmbly", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_A_Cthdc_Assmbly_11_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.P_ILISurveyGroup |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 437 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | ILI Survey Group |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {570D2124-A6DB-4894-A630-3B6D8EA56CA9} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_ILISurveyGroup represents a set of anomalies in the pipeline system as detected from inline inspection runs of a pigging device. The group or cluster is identified by a particular cluster rule. Each cluster represents a location on the pipeline with a specified length and width. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ilisurveygrouptype | ILI Survey Group Type | String | True | Pipeline_ILI_Survey_Type | 0 | 0 | 30 | True | False | The text value indicating the type of cluster of ILI readings. Valid values are Metal Loss, Crack, Mechanical Damage, Material Defect, and ILI Other. | ||
anomalycount | Anomaly Count | Long Integer | True | 0 | 0 | 4 | True | False | The numeric count of anomalies in the cluster. | |||
reldistance | Relative Distance | Double | True | 0 | 0 | 8 | True | False | The relative distance of the feature detected from the ILI run. | |||
rundistance | Run Distance | Double | True | 0 | 0 | 8 | True | False | The run distance recorded by the pigging device for the feature detected from inline inspection. | |||
safetyfactor | Safety Factor | Double | True | 0 | 0 | 8 | True | False | The pressure safety factor as designated for the ILI run. | |||
maxdepthpercent | Max Depth Percent | Double | True | 0 | 0 | 8 | True | False | The maximum depth as a percentage of the wall thickness for the cluster of anomaly point features. | |||
maxdepth | Max Depth | Double | True | 0 | 0 | 8 | True | False | The maximum depth of the cluster of anomaly point features. | |||
maxdepthunits | Max Depth Units | Short Integer | True | Units_for_Depth | 0 | 0 | 2 | True | False | The unit of measure for depth. | ||
grouplength | Group Length | Double | True | 0 | 0 | 8 | True | False | The length of the cluster of anomaly point features. | |||
groupwidth | Group Width | Double | True | 0 | 0 | 8 | True | False | The width of the cluster of anomaly point features. | |||
grouparea | Group Area | Double | True | 0 | 0 | 8 | True | False | The area of the cluster of anomaly point features. | |||
bprcalculatedaverage | BPR Calculated Average | Double | True | 0 | 0 | 8 | True | False | The mean back pressure ratio calculated for a set of anomaly point features. | |||
bprpigaverage | BPR PIG Average | Double | True | 0 | 0 | 8 | True | False | The mean back pressure ratio as determined by the pigging device for a set of anomaly point features. | |||
bprvarianceaverage | BPR Variance Average | Double | True | 0 | 0 | 8 | True | False | The mean variance between calculated back pressure ratio and pig back pressure ratio for a set of anomaly point features recorded by an inline pig run. | |||
rprcalculatedaverage | RPR Calculated Average | Double | True | 0 | 0 | 8 | True | False | The calculated mean rupture pressure ratio for a set of anomaly point features. | |||
rprpigaverage | RPR Pig Average | Double | True | 0 | 0 | 8 | True | False | The mean rupture pressure ratio as determined by the pigging device for a set of anomaly point features. | |||
rprvarianceaverage | RPR Variance Average | Double | True | 0 | 0 | 8 | True | False | The mean variance between calculated rupture pressure ratio and pig rupture pressure ratio for a set of anomaly point features recorded by an inline pig run. | |||
widthaverage | Width Average | Double | True | 0 | 0 | 8 | True | False | The average width of the cluster of anomaly point features. | |||
lengthaverage | Length Average | Double | True | 0 | 0 | 8 | True | False | The average length of the cluster of anomaly point features. | |||
depthaverage | Depth Average | Double | True | 0 | 0 | 8 | True | False | The average depth of the cluster of anomaly point features. | |||
maxdiameteraverage | Max Diameter Average | Double | True | 0 | 0 | 8 | True | False | The maximum average diameter of the cluster of anomaly point features. | |||
mindiameteraverage | Min Diameter Average | Double | True | 0 | 0 | 8 | True | False | The minimum average diameter of the cluster of anomaly point features. | |||
orientationaverage | Orientation Average | Double | True | 0 | 0 | 8 | True | False | The mean angular position of the cluster of anomaly point features. | |||
r85burstpressure | R85 Burst Pressure | Double | True | 0 | 0 | 8 | True | False | The burst pressure ratio determined using the R85 method. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_104 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ILISurveyGroup_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_ExcavationDamage__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 461 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_ExcavationDamage |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_ExcavationDamage__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {5C215786-798B-480C-AC33-3C87CAB851D5} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_Anomaly |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 413 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Anomaly |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {5C391ED8-C5FD-4EC5-B4AF-59C6D3F9AAD6} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_Anomaly describes deficiencies in the pipeline system as detected from inline inspection runs of a pigging device. Typical anomalies include corrosion, geometric distortions, and material defects such as gouges or dents. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectiondate | Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date of inspection. | |||
anomalytype | Anomaly Type | String | True | Pipeline_Anomaly_Type | 0 | 0 | 50 | True | False | The text value indicating the type of an anomaly. Valid values are external corrosion, internal corrosion, dent, or gouge. | ||
anomalystatus | Anomaly Status | String | True | Pipeline_Anomaly_Status | 0 | 0 | 20 | True | False | The text value indicating the status of an anomaly. Valid values are previously excavated, proposed, postponed, pending review, in progress, scheduled, and unknown. | ||
priority | Priority | String | True | Pipeline_Anomaly_Priority | 0 | 0 | 10 | True | False | The text value indicating the priority of an anomaly. Valid values are immediate, scheduled, monitored, and unknown. | ||
severity | Severity | String | True | Pipeline_Anomaly_Severity | 0 | 0 | 20 | True | False | The text value indicating the severity of an anomaly. Valid values are high, medium, and low. | ||
dateclosed | Date Closed | Date | True | 0 | 0 | 8 | True | False | The date of closing an anomaly. | |||
location | Location | String | True | 0 | 0 | 255 | True | False | The textual description of the location of an anomaly. | |||
depth | Depth | Double | True | 0 | 0 | 8 | True | False | The distance below the ground cover where the record is buried. | |||
anomlength | Length | Double | True | 0 | 0 | 8 | True | False | ||||
width | Width | Double | True | 0 | 0 | 8 | True | False | The width of an anomaly. | |||
maximumdiameter | Maximum Diameter | Double | True | 0 | 0 | 8 | True | False | The maximum diameter of the pipe segment at an anomaly. | |||
minimumdiameter | Minimum Diameter | Double | True | 0 | 0 | 8 | True | False | The minimum diameter of the pipe segment at an anomaly. | |||
orientation | Orientation | String | True | 0 | 0 | 5 | True | False | The angular position of an anomaly on a pipe cross section. | |||
ovality | Ovality | Double | True | 0 | 0 | 8 | True | False | The measure of the ovality of the pipe segment at an anomaly. | |||
recommendedremediation | Recommended Remediation | String | True | Pipeline_Anomaly_Remediation | 0 | 0 | 40 | True | False | The text value indicating the recommended remediation for an anomaly. Valid values are composite sleeve, coupling reinforcement, full encirclement weld, pipe cutout, saddle sleeve, welded sleeve, and unknown. | ||
rprcalculated | RPR Calculated | Double | True | 0 | 0 | 8 | True | False | The calculated rupture pressure ratio. | |||
rprpig | RPR Pig | Double | True | 0 | 0 | 8 | True | False | The rupture pressure ratio recorded by an inline pig run. | |||
rprvariance | RPR Variance | Double | True | 0 | 0 | 8 | True | False | The variance between calculated rupture pressure ratios and rupture pressure ratios recorded by an inline pig run. | |||
depthofcovermin | Depth of Cover Min | Double | True | 0 | 0 | 8 | True | False | The minimum depth of cover recommended. | |||
depthofcovermax | Depth of Cover Max | Double | True | 0 | 0 | 8 | True | False | The maximum depth of cover recommended. | |||
bprcalculated | BPR Calculated | Double | True | 0 | 0 | 8 | True | False | The calculated back pressure ratio. | |||
bprpig | BPR Pig | Double | True | 0 | 0 | 8 | True | False | The back pressure ratio recorded by an inline pig run. | |||
bprvariance | BPR Variance | Double | True | 0 | 0 | 8 | True | False | The variance between calculated back pressure ratios and pig back pressure ratios recorded by an inline pig run. | |||
anomalygroup_globalid | Anomaly Group GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The foreign key value used to relate an anomaly record to the related anomaly group. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_413_ANOMALYG | False | True | anomalygroup_globalid |
UUID_80 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_Anomaly_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_OperatingPressureRange |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 447 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Operating Pressure Range |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {64B67845-F972-45D5-B128-75FE49B62BEA} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_OperatingPressureRange describes the length or range of operating pressure for the pipe system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
pressuretype | Pressure Type | String | True | Pipeline_MAOP_Pressure_Estab_By | 0 | 0 | 50 | True | False | The text value indicating the type of operating pressure. Valid values are design, certificate, grandfather, special permit, pressure type, other, unknown, operator assigned, and historical. | ||
pressurevalue | Pressure Value | Double | True | 0 | 0 | 8 | True | False | The value of operating pressure. | |||
unitofmeasure | Unit of Measure | Short Integer | True | Units_for_Pressure | 0 | 0 | 2 | True | False | The unit of measure defining the operating pressure. | ||
dateassigned | Date Assigned | Date | True | 0 | 0 | 8 | True | False | The date and time the pressure value was assigned to the pipe system. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_114 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_OperatingPressureRange_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_CalibrationPoint |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 415 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Calibration Point |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {65FC3B01-8AF6-4AB0-A071-4AB822E6945C} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point featureclass P_Calibration_Point stores points representing locations along a pipeline centerline route where the route measure is explicitly defined. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
measure | Measure | Double | True | 0 | 0 | 8 | True | False | The measure value to be stored on routes in a linear referencing system (LRS) network. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
routeid | Route ID | String | True | 0 | 0 | 38 | True | False | The unique identifier for the target route. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
networkid | NetworkID | Short Integer | True | 0 | 0 | 2 | True | False | The unique identifier of the LRS network. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_82 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_CalibrationPoint_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_PipeExposure_P_ExposedPipeInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 474 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_PipeExposure |
Origin Primary Key | GlobalID |
Origin Foreign Key | PIPEEXPOSURE_GlobalID |
Destination Name | main.P_ExposedPipeInspect |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_ExposedPipeInspect |
Backward Path Label | P_PipeExposure |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {67C1883C-4B53-4C94-BF6E-D18331E5FD1F} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.ServiceTerritory |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 5 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Service Territory |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 913130.8418653458 |
Y-Min | 1815493.8641191944 |
X-Max | 1061083.590578679 |
Y-Max | 1876401.2846269459 |
Catalog ID | {6CB3FC40-5547-4051-A6E1-25D3FF4D4C1B} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The networks service territory that represents the operational area of the utility. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | objectid | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
globalid | globalid | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_9 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__ServiceTerritory_shape | True | True | shape |
Key | Value |
---|---|
Name | main.StructureJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 34 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Junction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {6D43491F-14A8-41CC-9AED-309C3F66B1E4} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Junction feature class represents features which are tracked in a utility's asset inventory system. A structure junction can be either a structural feature that a device is attached to or a container of devices. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of records. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | The discriminator field with a subtype specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | An indicator of the type of utility network association to which the record participates. | |
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the Utility Network managed subnetwork that the record participates in. | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the record was completed. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the record. In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the record. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The value indicating the life cycle state of the record. | |
quantity | Quantity | Short Integer | True | 0 | 0 | 2 | True | False | The length of time the pressure monitoring device will be in use. | |||
weight | Weight | Double | True | 0 | 0 | 8 | True | False | The measured mass of the anodes at the specific location. | |||
barcode | Barcode | String | True | 0 | 0 | 16 | True | False | The ASTM F2897-15 code read from the bar code on the record. | |||
manufacturer | Manufacturer | String | True | 0 | 0 | 2 | True | False | The name of the company responsible for the creation of the pig structure. | |||
manufacturerlotno | Manufacturer Lot# | Long Integer | True | 0 | 0 | 4 | True | False | The manufacturer lot number from which the record was created. | |||
manufacturedate | Manufacture Date | Date | True | 0 | 0 | 8 | True | False | The date the record was created by the manufacturer. | |||
manufacturecomponent | Manufacturer Component | String | True | 0 | 0 | 2 | True | False | The manufacturer-specified, industry standard specification that was followed when the pipe segment was created. Subtype-specific coded value domains are based on the ASTM F2897 bar code derived values. | |||
material | Material | String | True | 0 | 0 | 2 | True | False | The primary material used in the construction of the record. | |||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the record. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | |||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsz | GPS Z | Double | True | 0 | 0 | 8 | True | False | The elevation coordinate of the record when it was originally inserted into the geodatabase. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the record was installed. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the record. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this record. | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | This value defines the angular degrees that the point symbol should be rotated. The purpose is to have the feature's display symbology automatically rotated to the angle defined in this attribute. | ||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | A description of the location of the record. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_34_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_38 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Pipe Muffler | 1 | The subtype feature layer Pipeline Muffler describes the pipeline facility component used to reduce the noise produced by a compressor or pump. |
Pipe Anchor | 2 | The subtype feature layer Pipeline Anchor describes the pipeline component used to secure the pipeline to a specific location. |
Pipe Support | 3 | The subtype feature layer Pipeline Pipe Support describes the pipeline facility component used to support a pipe segment. |
Pipe Hanger | 4 | The subtype feature layer Pipeline Pipe Hanger describes the pipeline facility component used to hang a pipe segment from an elevated location. |
Pipe End Connection | 5 | The subtype feature layer Pipeline End connection describes the type of connection at the end of a pipe casing. |
Pipe Vault | 6 | The subtype feature layer Pipeline Vault Boundary describes the below ground structure used to house oil and gas facilities such as compressor stations, pump stations, town border stations and regulator stations. |
Pipe Box | 7 | The subtype feature layer Pipeline Valve Box describes the underground structure which stores a gas valve. |
Pipe Sleeve | 8 | |
Pipe Access Point | 10 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 12.6 | 1 | StructureJunction-GenerateIDs | Generate IDs for StructureJunction using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:18:58 | // Assigned To: StructureJunction // Type: Calculation // Name: StructureJunction-GenerateIDs // Description: Generate IDs for StructureJunction using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureBoundary-GenerateIDs // - StructureLine-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineJunction-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Pp-Mfflr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Mfflr_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "Pp-Anchr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Anchr_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "Pp-SUP", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_SUP_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Pp-Hngr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Hngr_4_seq'); }else if (selector_value_txt == '5') { id_format = { 'prefix': "Pp-End-Cnnctn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_End_Cnnctn_5_seq'); }else if (selector_value_txt == '6') { id_format = { 'prefix': "Pp-VLT", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_VLT_6_seq'); }else if (selector_value_txt == '7') { id_format = { 'prefix': "Pp-Bx", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Bx_7_seq'); }else if (selector_value_txt == '8') { id_format = { 'prefix': "Pp-Slv", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Slv_8_seq'); }else if (selector_value_txt == '10') { id_format = { 'prefix': "Pp-Accss-Pnt", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('SJ_Pp_Accss_Pnt_10_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.P_PipeExposure |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 451 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Pipe Exposure |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {6D5C5484-B246-4003-9F6F-8B5EA964096A} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_PipeExposure describes the length or range of the pipe system that is exposed to the atmosphere. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
lengthexposed | Length Exposed | Double | True | 0 | 0 | 8 | True | False | The length of pipe exposed to the atmosphere. | |||
lengthunits | Length Units | Short Integer | True | Units_for_Length | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | ||
locationdescription | Location Description | String | True | 0 | 0 | 50 | True | False | A description of the location of the record. | |||
inspectionrange_globalid | Inspection Range GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The inspection range feature class column containing the matching primary key value for relationships to associated components. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_451_INSPECTI | False | True | inspectionrange_globalid |
UUID_118 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_PipeExposure_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_ILIInspectionRange |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 436 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | ILI Inspection Range |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {738B854E-4B3A-4D14-9940-780A55E727DB} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_ILIInspectionRange describes the length or range of inline inspection (ILI) performed on a pipe segment. ILI of a transmission pipeline may be broken into sections (P_InlineInspections) due to the length of the pipeline and where the pigging device can be inserted and retrieved. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
startodo | Start ODO | Double | True | 0 | 0 | 8 | True | False | The odometer reading on the pigging device at the start of the ILI run. | |||
endodo | End ODO | Double | True | 0 | 0 | 8 | True | False | The odometer reading on the pigging device at the end of the ILI run. | |||
sequence | Sequence | Long Integer | True | 0 | 0 | 4 | True | False | The numeric order that determines the sequence of multiple ILI run ranges that constitute an entire ILI run for a given pipeline. | |||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Additional description of the ILI run. | |||
inlineinspectionid | Inline Inspection ID | GUID | True | 0 | 0 | 38 | True | False | The inline inspection feature class column containing the matching primary key value for relationships to associated components. | |||
inspectionyear | Inspection Year | Short Integer | True | 0 | 0 | 2 | True | False | The year the ILI run occurred. | |||
corrosionmetallosscheck | Corrosion and Metal Loss Check | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether metal loss due to corrosion is checked. | |
dentdeformationcheck | Dent and Deformation Check | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether formation of dents is checked. | |
cracklongseamdefectcheck | Crack and Long Seam Defect Check | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether a crack or long seam defect is checked. | |
otherinspectioncheck | Other Inspection Check | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether another inspection is also performed along with ILI. | |
otherinspectiontype | Other Inspection Type | String | True | 0 | 0 | 50 | True | False | The description of inspection type if OTHER INSPECTION CHECK is performed. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_103 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ILIInspectionRange_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_Centerline |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 417 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Centerline |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {75BAFD88-2410-4DE1-B1EB-250D756A5E72} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_Centerline provides a single source of geometry for all linear referencing system networks. Every record represents a single range of the pipe system with continuous stationing along the pipe centerline. Centerlines typically go from start of the pipe to the end of the pipe, or an equation point where the stationing is reset. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
centerlineid | CenterlineID | GUID | True | 0 | 0 | 38 | True | False | The unique ID for the centerline geometry. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_84 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_Centerline_shape | True | True | shape |
Key | Value |
---|---|
Name | main.PipelineDevice |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 375 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Pipeline Device |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {76665B49-5DF6-4498-9BE8-89027F298004} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | These Device feature class represents features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of features. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | A discriminator field with a subtype-specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | An indicator of the type of utility network association to which the device feature participates. | |
ISSUBNETWORKCONTROLLER | Is subnetwork controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | The boolean true/false value indicating whether the device is a subnetwork controller. | |
ISCONNECTED | Is connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | The Boolean true/false value indicating whether the device is connected to a subnetwork controller. | |
SUBNETWORKCONTROLLERNAME | Subnetwork controller name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | If the device is of an asset group/asset type which has been designated as a subnetwork controller within the Utility Network configuration, this is the unique name assigned to the device. | |
TIERNAME | Tier name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | If the device is of an asset group/asset type which has been designated as a subnetwork controller within the Utility Network configuration, this is the name of the tier to which the subnetwork controller is associated. | |
TIERRANK | Tier rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | If the device is of an asset group/asset type which has been designated as a subnetwork controller within the Utility Network configuration, this is the rank of the tier to which the subnetwork controller is associated. | ||
TERMINALCONFIGURATION | Terminal Path | String | False | Default | 0 | 0 | 128 | True | True | If the device is of an asset group/asset type which has been designated as a subnetwork controller within the Utility Network configuration, this is name of the terminal to which the subnetwork controller is associated. | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. This is the primary key value for relationships to child tables. | ||
CPSubnetworkName | CP Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the cathodic protection tier subnetwork where the device is located. | |
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SystemSubnetworkName | System Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the system zone tier subnetwork where the device is located. | |
PressureSubnetworkName | Pressure Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the pressure zone tier subnetwork where the device is located. | |
IsolationSubnetworkName | Isolation Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the isolation zone tier subnetwork where the device is located. | |
adddetails | Additional Details and Clockwise to Close | Short Integer | True | 0 | 0 | 2 | True | False | Additional information about the device such as clockwise to close. | |||
devicestatus | Device Status | Short Integer | True | Pipeline_Valve_Status | 0 | 0 | 2 | True | False | A Boolean indicator of whether the device is open or closed to allowing the flow of the commodity thru the device. | ||
regulatorytype | Regulatory Type | Short Integer | True | Pipeline_Regulatory_Type | 0 | 0 | 0 | 2 | True | False | The value indicating the regulatory status of the excess flow valve feature. This is used by the Facility Reporting tools to differentiate between Distribution, Transmission, Offshore Transmission, Gathering, and Offshore Gathering pipe. | |
designtype | Type | Short Integer | True | 0 | 0 | 2 | True | False | The design type of the record. | |||
piggable | Piggable | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | |||
operable | Operable | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | |||
accessible | Accessible | Short Integer | True | Yes_No | 1 | 0 | 0 | 2 | True | False | The value used by the isolation trace tool to identify when a valve is no longer accessible for the purpose of emergency shutoffs. | |
yesno | Drain Valve Indicator Internal Meter, or SCADA Indicator | Short Integer | True | 0 | 0 | 2 | True | False | A general field to capture details of records. | |||
turnstoclose | Turns to Close | Double | True | 0 | 0 | 8 | True | False | The number of 360-degree turns required to close the valve. | |||
normalposition | Normal Position | Short Integer | True | 0 | 0 | 2 | True | False | The Boolean value indicating whether the valves most frequent position is open or closed. | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the excess flow valve was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the excess flow valve was put into production. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
serialnumber | Serial Number | String | True | 0 | 0 | 20 | True | False | The unique identifier physically labeled on the device. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the excess flow valve In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the excess flow valve. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The text value indicating the life cycle state of the excess flow valve. | |
maopdesign | MAOP Design | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure as defined during design. | |
maoptest | MAOP Test | Double | True | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The tested maximum allowable operating pressure during installation. | |
maoprecord | MAOP Record | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure under which the excess flow valve is currently operating. | |
depth | Depth | Double | True | 0 | 0 | 8 | True | False | The distance below the ground cover where the excess flow valve is buried. | |||
depthtonut | Depth to Nut | Double | True | 0 | 0 | 8 | True | False | The DEPTHTONUT value is the vertical distance below the surface to access the valve nut. | |||
measuredlength | Length | Double | True | 0 | 0 | 8 | True | False | The end-to-end distance of the record. | |||
diameter | Diameter | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the center of the upstream excess flow valve orifice. | |||
maxinletpressure | Max Inlet Pressure | Double | True | 0 | 0 | 8 | True | False | The maximum pressure allowed at the inlet of the record. | |||
maxoutletpressure | Max Outlet Pressure | Double | True | 0 | 0 | 8 | True | False | The maximum pressure allowed to exit the record. | |||
setpressureentered | Set Pressure Entered | Double | True | 0 | 0 | 8 | True | False | The pressure at which the relief valve is designed to open. | |||
setpressurestandard | Set Pressure Standard | Double | True | 0 | 0 | 8 | True | False | The standard operating pressure through the relief valve. | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | This value defines the angular degrees that the point symbol should be rotated. The purpose is to have the feature's display symbology automatically rotated to the angle defined in this attribute. | ||
barcode | Barcode | String | True | 0 | 0 | 16 | True | False | The ASTM F2897-15 code read from the bar code on the device. | |||
manufacturer | Manufacturer | String | True | 0 | 0 | 2 | True | False | The organization that built the device. Coded Value Domain: Pipeline_ASTM_Manufacturer | |||
manufacturerlotno | Manufacturer Lot # | Long Integer | True | 0 | 0 | 4 | True | False | The manufacturer lot number from which the device was created. | |||
manufacturedate | Manufacture Date | Date | True | 0 | 0 | 8 | True | False | The date the device was created by the manufacturer. | |||
manufacturecomponent | Manufacture Component | String | True | 0 | 0 | 2 | True | False | The manufacturer-specified, industry standard specification that was followed when the excess flow valve feature was created. | |||
material | Material | String | True | 0 | 0 | 2 | True | False | The primary material used in the construction of the record. | |||
casingmaterial | Casing Material | String | True | 0 | 0 | 20 | True | False | The material used for the construction of the regulator casing. | |||
devicename | Name | String | True | 0 | 0 | 20 | True | False | The organization identified name given to the device. | |||
quantity | Quantity | Double | True | 0 | 0 | 8 | True | False | The length of time the pressure monitoring device will be in use. | |||
weight | Weight | Double | True | 0 | 0 | 8 | True | False | The measured mass of the anodes at the specific location. | |||
amperage | Amperage | Double | True | 0 | 0 | 8 | True | False | The measure of the electrical current generated by the rectifier. | |||
usage | Usage | Double | True | 0 | 0 | 8 | True | False | The amount of gas consumed by the device, such as a gas lamp. | |||
duration | Duration | Long Integer | True | 0 | 0 | 4 | True | False | The duration for which the gas usage was measured. | |||
height | Height | Double | True | 0 | 0 | 8 | True | False | The vertical distance from the ground surface to the highest point on the gas lamp. | |||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the excess flow valve. | |||
iscritical | Critical Valve | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the device such as a valve is considered critical for the organization. | |||
flowcapacity | Flow Capacity | Double | True | 0 | 0 | 8 | True | False | The volume-based measurement of the flow of gas through the excess flow valve. | |||
permanentindicator | Permanent Indicator | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the device installation is considered permenant. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the features geometry when the feature is included in the geodatabase. | |||
depthunits | Depth Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the distance below the surface where the excess flow valve is located. | |||
diameterunits | Diameter Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the diameter of the excess flow valve. | |||
flowcapacityunits | Flow Capacity Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for the volume of flow capacity. | |||
heightunits | Height Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measurement for the value stored in the HEIGHT attribute. | |||
lengthunits | Length Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | |||
pressureunits | Set Pressure Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the operating pressure. | |||
maopunits | MAOP Unit of Measure | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure defining the maximum allowable operating pressure. | |||
usageunits | Usage Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measurement for the value stored in the USAGE attribute. | |||
usagerateunits | Usage Rate Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measurement for the value stored in the usagerate attribute. | |||
recordingmethod | Recording Method | String | True | 0 | 0 | 25 | True | False | The method used by the meter to record the volume of flow. | |||
regulatorbodytype | Regulator Body Type | String | True | 0 | 0 | 20 | True | False | The style of the regulator. | |||
outletdiameter | Outlet Diameter | Double | True | 0 | 0 | 8 | True | False | The edge to edge measured length of a straight line through the center of the regulator outlet. | |||
diaphragmdiameter | Diaphragm Diameter | Double | True | 0 | 0 | 8 | True | False | The outer edge to outer edge nominal length of a straight line through the center of the regulator diaphragm. | |||
premise | Premise | String | True | 0 | 0 | 10 | True | False | The Customer Information System unique identifier that links the meter to the customer record. | |||
indoormeter | Indoor Meter | Short Integer | True | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the meter is installed inside of the customer facility. | |||
operatingclassification | Operating Classification | String | True | 0 | 0 | 40 | True | False | ||||
maxdifferentialpressure | Max Differential Pressure | Double | True | 0 | 0 | 8 | True | False | The manufacturer-specified maximum pressure drop difference between the strainer upstream pressure and the strainer downstream pressure. | |||
companypaidtelephone | Company Paid Telephone | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the device can be monitored remotely. | |||
telephonenumber | Telephone Number | String | True | 0 | 0 | 15 | True | False | The telephone number to access the pressure monitoring device. | |||
usagerate | Usage Rate | Double | True | 0 | 0 | 8 | True | False | The rate of natural gas consumption by the gas lamp when it is in use. | |||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsz | GPS Z | Double | True | 0 | 0 | 8 | True | False | The elevation coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the excess flow valve feature was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the excess flow valve feature. | |||
servicesummaryid | Service Summary ID | GUID | True | 0 | 0 | 38 | True | False | The foreign key unique value used to relate the excess flow valve feature to the SERVICESSUMMARY feature class record with which it participates. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this excess flow valve feature. | |||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each event record. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the event became active on the route. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the event was retired from the route. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The name of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the anomaly is located. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset feature. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point feature class. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting feature. This can be Coordinates, Feature/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Excess Flow Valve features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
bondedinsulated | Bonded/Insulated | Short Integer | True | Bonded_Insulated | 0 | 0 | 2 | True | False | A Boolean indicator of whether the device acts as a conductive device (bonded) or an non-conductive device (insulated) in a cathodic protection system. Coded Valve Domain: Bonded_Insulated. | ||
cptraceability | Cathodic Protection Traceability | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | A Boolean indicator of whether the normal function of the device is traceable in a cathodic protection zone. Coded Value Domain: CP_Traceability | ||
cpoverride | CP Override | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | A Boolean indicator of a temporary state of whether the device is traceable in a cathodic protection zone. Coded Valve Domain: CP_Traceability | ||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the excess flow valve. | |||
wallthickness | Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturer defined thickness of the exterior wall of the upstream excess flow valve orifice. | |||
wallthickness2 | Wall Thickness 2 | Double | True | 0 | 0 | 8 | True | False | The manufacturer defined thickness of the exterior wall of the downstream excess flow valve orifice | |||
diameter2 | Diameter 2 | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the center of the downstream record. | |||
temprating | Temp Rating | String | True | 0 | 0 | 20 | True | False | The manufacturers specified temperature rating. | |||
coolingmethod | Cooling Method | String | True | 0 | 0 | 20 | True | False | The system used to prevent the rectifier from overheating. | |||
rating | Rating | Double | True | 0 | 0 | 8 | True | False | The manufacturer certified maximum operating pressure for which the device can operate. | |||
specification | Specification | String | True | 0 | 0 | 30 | True | False | The manufacturer certified industry standard to which the device was built. | |||
remoteoperation | Remote Operation | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | A yes/no boolean value indicating whether the device can be remotely operated. | ||
valvekeysize | Valve Key Size | Short Integer | True | 0 | 0 | 2 | True | False | The size of the key required to operate the device such as a valve. | |||
modelnumber | Model Number | String | True | 0 | 0 | 20 | True | False | The manufacturer model. | |||
deviceactuatortype | Device Actuator Type | Short Integer | True | 0 | 0 | 2 | True | False | A indicator of how the device actuates its movements when operated. | |||
operatortype | Operator Type | Short Integer | True | 0 | 0 | 2 | True | False | A indicator of whether the device is operated manually or remotely. | |||
remotedevicefailtype | Remote Device Fail Type | Short Integer | True | 0 | 0 | 2 | True | False | Defines the state the device sets to should a failure occur. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_375_SUBNETWO | False | True | SUBNETWORKCONTROLLERNAME |
GDB_375_CPSubnet | False | True | CPSubnetworkName |
GDB_375_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_375_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_375_SystemSu | False | True | SystemSubnetworkName |
GDB_375_Pressure | False | True | PressureSubnetworkName |
GDB_375_Isolatio | False | True | IsolationSubnetworkName |
UUID_43 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__PipelineDevice_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Excess Flow Valve | 1 | The subtype feature layer Excess Flow Valve describes the devices typically installed in a service line to prevent a pressure surge from propagating further down the pipe system. CFR 49 192.381 defines the performance standards for service line excess flow valves (EFV). |
Meter | 2 | The subtype feature layer Meter describes a measuring device of the volume of commodity flowing through the meter. |
Controllable Valve | 3 | The subtype feature layer Controllable Valve describes the component that can permit or prevent the flow through the pipe system. These components are used within a utility network to perform valve isolation traces. |
Flow Valve | 4 | The subtype feature layer Flow Valve describes the component that restricts the flow of the commodity to a singe direction. |
Relief Valve | 5 | The subtype feature layer Relief Valve describes the device in a pipe system that is responsible for automatically opening when the pressure rises above a set pressure. This is designed to prevent over pressure damage to the pipe system. Relief valves are typically located within facilities such as regulator stations and town border stations. |
Strainer | 6 | The subtype feature layer Strainer describes the component within a pipe system that removes free liquids or dirt particles from the commodity fluid or gas. |
Pressure Monitoring Device | 8 | The subtype feature layer Pressure Monitoring Device describes the component in a pipe system that can measure and record the flow at the installed location. These devices can be installed to permanently measure flow and to temporarily measure flow at a specific location. |
Lamp | 9 | The subtype feature layer Lamp describes street lamps that are fueled by natural gas. |
Compressor | 10 | The subtype feature layer Compressor describes the device that can mechanically increase the gas pressure in the pipe system. |
Wellhead Source Flange | 11 | The subtype feature layer Wellhead Source Flange describes the device on the wellhead that is the subnetwork controller source for gathering and storage systems. |
Controllable Tee | 12 | The subtype feature layer Controllable Tee describes the fittings that can mechanically control the flow of fluids or gases through the pipe system. |
Line Stopper | 13 | The subtype feature layer Line Stopper describes the fittings that can mechanically control the flow of fluids or gases through the pipe system. |
Pump | 18 | The subtype feature layer Pump describes the device that can mechanically increase the pressure on the hazardous liquid to move it through the pipe system. |
Regulator | 19 | The subtype feature layer Regulator describes the mechanical devices used in a pipe system for the controlled reduction of pressure. Regulators are typically contained within a regulator station or a town border station. |
Scrubber | 20 | The subtype feature layer Scrubber describes the component within a pipe system that removes harmful materials from gas. |
Anode | 50 | The subtype feature layer Anode describes the corrosive component that sacrifices its electrons to protect the metal of the pipe system. |
Rectifier | 51 | The subtype feature layer Rectifier describes the device that generates the current for the cathodic protection system. |
Test Point | 52 | The subtype feature layer Test Point describes the read point location where the electric potential can be measured for a cathodic protection system. |
Decoupler | 53 | |
Grounding Point | 54 | |
Service Station | 21 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 12.7 | 1 | Device - Auto Contain By Rules | Auto contain pipeline devices. Uses the rule table to contain feature in a container within a search distance | Calculation | False | True | True | False | True | False | True | 2024-04-26 11:19:08 | // Assigned To: PipelineDevice // Type: Calculation // Name: Device - Auto Contain By Rules // Description: Auto contain pipeline devices. Uses the rule table to contain feature in a container within a search distance // Subtypes: All // Trigger: Insert, Update // Exclude From Client: True // Disable: True // Implementation Note: This rule is disabled by default as it auto performs containment of features when editing. If you desire these functions, enable this rule and adjust the settings below. // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Auto Contain By Rules // - Junction - Auto Contain By Rules // - Line - Auto Contain By Rules // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // The subtype and asset type fields of $feature // ** Implementation Note: These fields are used to determine what Container associations are possible from the Rules table. var assetgroup = $feature.assetgroup var assettype = $feature.assettype // The association status field, this field is maintained by the utility network // ** Implementation Note: Do not change this value, it is in this section in case there is a schema change to the utility network in the future. var association_status = $feature.associationstatus; // The distance to search for a container // ** Implementation Note: Adjust this value based on the distance to auto contain, the comment after the value is an example how to use a // field to defined the distance, this field does not exist in the data model, but could be added to provide a data specific distance. var search_distance = 40; //DefaultValue($feature.searchdistance, 40); // The unit of the distance value in search_distance. // ** Implementation Note: Set the distance to search, for unit codes - https://desktop.arcgis.com/en/arcobjects/latest/net/webframe.htm#esriSRUnitType.htm var search_unit = 9002; // The utility network class ID for each layer. // ** Implementation Note: Adjust these values to match your geodatabase. The values defined below are for a Version 4 // utility network with only the schema provide(no additional domain networks) // These values will change with a version 3 utility network or if you applied more than one domain to the same utility network. // To review these values, open the attribute domains in the database with the utility network and search for FeatureSourceID. This domain // will list the class id by un domain alias, not class name, so you will have to related the un attribute domain to the gdb class name to match its ID function class_id_to_name(id) { return Decode(Text(id), "1", "Association", "2", "SystemJunction", "3", "SystemJunctionObject", "4", "StructureJunction", "5", "StructureLine", "6", "StructureBoundary", "7", "StructureJunctionObject", "8", "StructureEdgeObject", "9", "PipelineDevice", "10", "PipelineLine", "11", "PipelineAssembly", "12", "PipelineJunction", "13", "PipelineSubnetLine", "14", "PipelineJunctionObject", "15", "PipelineEdgeObject", null) } // monikerize FeatureSetByName function var get_features_switch_yard = FeatureSetByName; // A function to determine if the edit is triggered by UpdateSubnetwork. If a filegeodatbase, this action triggers an edit event, if enterprise, triggering the event is optional // ** Implementation Note: If using the industry model with all tiers, no change is required. If a tier was removed, remove the matching if block. function is_edit_from_subnetwork() { if ($feature.systemsubnetworkname != $originalfeature.systemsubnetworkname) { return true; } if ($feature.pressuresubnetworkname != $originalfeature.pressuresubnetworkname) { return true; } if ($feature.isolationsubnetworkname != $originalfeature.isolationsubnetworkname) { return true; } if ($feature.cpsubnetworkname != $originalfeature.cpsubnetworkname) { return true; } return false; } // ************* End User Variables Section ************ // ************* Functions ************* function geometry_change() { if (IsEmpty($originalfeature)) { return true; } if (IsEmpty(Geometry($originalfeature))) { return true; } return !Equals(Geometry($feature), Geometry($originalfeature)); } function sortCandidates(a, b) { if (a['distance'] < b['distance']) return -1; if (a['distance'] > b['distance']) return 1; return 0; } function build_containers_info() { var rule_fields = ['OBJECTID', 'RULETYPE', 'FROMNETWORKSOURCEID', 'FROMASSETGROUP', 'FROMASSETTYPE', 'TOASSETGROUP', 'TOASSETTYPE', 'GLOBALID'] var rules_fs = get_features_switch_yard($datastore, 'UN_6_Rules', rule_fields, false); var containers_rows = Filter(rules_fs, 'RULETYPE = 2 and TOASSETGROUP = @assetgroup and TOASSETTYPE = @assettype'); var container_row_count = Count(containers_rows) if (container_row_count == 0) { return null; } var container_class_types = {}; for (var container_row in containers_rows) { var class_name = class_id_to_name(container_row['FROMNETWORKSOURCEID']); if (IsEmpty(class_name)) { return {'errorMessage': 'Unable to translate Class ID to Class, attribute rules needs updating'}; } if (HasKey(container_class_types, class_name) == false) { container_class_types[class_name] = {}; } var asset_group = Text(container_row['FROMASSETGROUP']) if (HasKey(container_class_types[class_name], asset_group) == false) { container_class_types[class_name][asset_group] = []; } var asset_type = Text(container_row['FROMASSETTYPE']) if (IndexOf(container_class_types[class_name][asset_group], asset_type) == -1) { push(container_class_types[class_name][asset_group], asset_type) } } return container_class_types } function build_sql(container_info, feat_global_id) { var sql_class = []; var i = 0; for (var cls in container_info) { var sub_where = []; var k = 0; for (var ag in container_info[cls]) { sub_where[k++] = "(AssetGroup = " + ag + " AND AssetType IN (" + Concatenate(container_info[cls][ag], ',') + '))' } sql_class[i++] = [cls, '(' + Concatenate(sub_where, ' OR ') + ") and GLOBALID <> '" + feat_global_id + "'"]; } return sql_class } function generate_candidates(feature, sql_by_class, search_shape) { var container_candidate = []; var k = 0; for (var i = 0; i < Count(sql_by_class); i++) { var class_name = sql_by_class[i][0]; var where = sql_by_class[i][1]; var fs = get_features_switch_yard($datastore, class_name, ['GLOBALID'], false); var container_features = Filter(Intersects(fs, search_shape), where); var cont_feat_count = Count(container_features); if (cont_feat_count > 0) { for (var feat in container_features) { container_candidate[k++] = { 'class_name': class_name, 'globalid': feat.globalid, 'distance': Distance(feature, feat, 9002) } } } } return container_candidate; } // ************* End Functions Section ***************** // in FGDB, update subnetwork triggers an update operations, exit if (!($editContext.editType=='INSERT') && is_edit_from_subnetwork()) { return; } // If the geometry did not change on an update, return if (!($editContext.editType=='INSERT') && !geometry_change()) { return; } // If the feature is already content, return if ((association_status & 0x14) > 0) { return; } var container_info = build_containers_info(); if (IsEmpty(container_info)) { return; } if (TypeOf(container_info) == 'Dictionary') { if (HasKey(container_info, 'errorMessage')) { return container_info; } } var sql_by_class = build_sql(container_info, $feature.globalid); var search_shape = Buffer(Geometry($feature), search_distance, search_unit); var candidates = generate_candidates($feature, sql_by_class, search_shape) if (Count(candidates) == 0) { return; } var sorted_candidates = Sort(candidates, sortCandidates); var edit_payload = [{ 'className': sorted_candidates[0]['class_name'], 'updates': [{ 'globalID': sorted_candidates[0]['globalid'], 'associationType': 'container' }] }]; return {"edit": edit_payload}; | ||||||||
5 | 12.7 | 2 | Device - Cathodic Protection Traceability | Cathodic protection traceability for pipeline devices. Set traceability flag for device assets | Calculation | False | True | True | False | cptraceability | True | True | False | 2024-04-26 11:19:08 | // Assigned To: PipelineDevice // Type: Calculation // Name: Device - Cathodic Protection Traceability // Description: Cathodic protection traceability for pipeline devices. Set traceability flag for device assets // Subtypes: All // Field: cptraceability // Trigger: Insert, Update // Exclude From Client: False // Disable: False // Is Editable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Cathodic Protection Traceability // - Junction - Cathodic Protection Traceability // - Line - Cathodic Protection Traceability // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the CP information // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.cptraceability; var cp_override = $feature.cpoverride; var cp_bondedinsulated = $feature.bondedinsulated; // Field in the data model used to store and manage the material details // ** Implementation Note: This value does not need to change if using the industry data model var cp_material = $feature.material; // The list of material types that are conductive from the material field and the ASTM_Pipe_Material domain // ** Implementation Note: These do not need to be adjusted unless the value of the material attribute domains were changed. var conductive_materials = ['0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'S', 'R', 'Q', 'P', 'O', 'N', 'M']; // The list of material types that are not conductive from the material field and the ASTM_Pipe_Material domain // ** Implementation Note: These do not need to be adjusted unless the value of the material attribute domains were changed. var non_conductive_materials = ['A','B','C','D','E','F','G','H','J','K','L','T','U','V']; // Limit the rule to valid asset groups/subtypes // ** Implementation Note: Instead of recreating this rule for each subtype, this rules uses a list of subtypes and exits if not valid // If you have added Asset Groups, they will need to be added to this list. var valid_asset_groups = [1, 2, 3, 4, 5, 6, 8, 9, 10, 11, 12, 13, 18, 19, 20, 50, 51, 52, 53, 54]; // List of asset groups that are always included in a CP trace. // ** Implementation Note: If you have extended the CP model for additional asset groups, those asset groups should be added here var asset_groups_always_traceability = [50, 51, 52, 53, 54]; // List of asset groups that are always not include in a CP trace and are CP barriers. // ** Implementation Note: If you have extended the pipe model for additional asset groups that never conduct cp current, those asset groups should be added here var asset_groups_never_traceability = []; // Values to determine traceability // ** Implementation Note: These do not need to be adjusted unless the value of the CP_Traceability attribute domain were changed. var traceable = 1; // Also used for Bonded var not_traceable = 2; // Also used for Insulated // ************* End User Variables Section ************* if (!Includes(valid_asset_groups, $feature.assetgroup)) { return assigned_to_field; } // If an override is specified, use that value regardless of other attributes if (cp_override > 0) { return cp_override; } // If a device is always traceable or not, regardless of material, return the proper status if (Includes(asset_groups_always_traceability, $feature.assetgroup)) { return traceable; } if (Includes(asset_groups_never_traceability, $feature.assetgroup)) { return not_traceable; } // If a value is set on the bonded, insulated field, return that value if (!IsEmpty(cp_bondedinsulated) && cp_bondedinsulated > 0) { return cp_bondedinsulated; } // Check if the material is conductive if (Includes(conductive_materials, cp_material)) { return traceable; } if (Includes(non_conductive_materials, cp_material)) { return not_traceable; } //Return the value in the field when no other condition is met return assigned_to_field; | |||||||
6 | 12.7 | 3 | Device - Symbol Rotation | Rotate Pipeline Devices to match intersecting Line. Intersects a line layer and based on the number of intersected features, calculates the angle for the point | Calculation | False | True | True | False | symbolrotation | True | True | True | 2024-04-26 11:19:09 | // Assigned To: PipelineDevice // Type: Calculation // Name: Device - Symbol Rotation // Description: Rotate Pipeline Devices to match intersecting Line. Intersects a line layer and based on the number of intersected features, calculates the angle for the point // Subtypes: All // Field: symbolrotation // Trigger: Insert, Update // Exclude From Client: False // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Symbol Rotation // - Junction - Symbol Rotation // ************* User Variables ************* // Field in the data model used to store and manage the rotation of the feature // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.symbolrotation; // Set to true if the rotation setting is set to geographic in the layer properties // ** Implementation Note: This value does not need to change if using the industry maps var geographic_rotation = false; // Set the counter clockwise spin angle used for the symbol in the symbology options // ** Implementation Note: This value does not need to change if using the industry maps var symbol_flip_angle = 0 // Name of the Line layer to intersect // ** Implementation Note: This value does not need to change if using the industry maps var pipeline = "PipelineLine" // ************* End User Variables Section ************ // Return if a value is already set, to recalculate an angle, the field must be set to null if (!IsEmpty(assigned_to_field)) { return assigned_to_field; } // monikerize FeatureSetByName function var get_features_switch_yard = FeatureSetByName; // Create a feature set to the line layer var lineClass = get_features_switch_yard($datastore, "PipelineLine", ["objectid"], true); // Find the intersecting lines var lines = Intersects(lineClass, $feature); //If no lines intersect, return the original value if (Count(lines) == 0) { return assigned_to_field; } var diff_tol = 5; // Variable to store all found angles var angles = []; // Store the features geometry var feature_geometry = Geometry($feature); // Loop over all intersecting lines and find their angles var angle_type; var angle_value; for (var line in lines) { // Buffer and create an extent of the point by a small amount to extract the segment var clip_area = Extent(Buffer($feature, .01, "meter")); // Clip the line by the extent and get the first line segment var segment = Clip(line, clip_area)["paths"][0]; // The features location is on the start of the line, get the angle from the feature to the end vertex if (Equals(segment[0], feature_geometry)) { angle_type = 'from' angle_value = Round(Angle(feature_geometry, segment[-1]), 0) } // The features location is on the end of the line, create a new segment from the feature to the start vertex else if (Equals(segment[-1], feature_geometry)) { angle_type = 'to' angle_value = Round(Angle(feature_geometry, segment[0]), 0) } // The features location is midspan of the segment, use the angle of the segment else { angle_type = 'mid' angle_value = Round(Angle(segment[0], segment[-1]), 0) } if (geographic_rotation == true) { // Convert Arithmetic to Geographic angle_value = (450 - angle_value) % 360; } // Add 180 to match 0 rotation in the TOC // Add user specified spin angle if their symbol is rotated angle_value = (angle_value + 180 + symbol_flip_angle) % 360; push(angles, {'angle': angle_value, 'type': angle_type}); } // If only one angle, return that value if (Count(angles) == 1) { // If the point is midspan, flip to match symbol as it if was on the end point if (angles[0]['type'] == 'mid') { return (angles[0]['angle'] + 180) % 360; } return angles[0]['angle']; } else if (Count(angles) == 2) { // If the feature is midspan of the first line, return the angle of the second line if (angles[0]['type'] == 'mid') return angles[1]['angle']; // If the feature is midspan of the second line, return the angle of the first line else if (angles[1]['type'] == 'mid') return angles[0]['angle']; // If the feature is at the end point of both lines, return the angle of the first line else if (angles[0]['type'] == 'to' && angles[1]['type'] == 'to') { return angles[0]['angle']; } // If the feature is at the start point of both lines, return the angle of the first line else if (angles[0]['type'] == 'from' && angles[1]['type'] == 'from') { return angles[0]['angle']; } // If the feature is at the start point of the first line and end of the second line, return the second line else if (angles[0]['type'] == 'from') { return angles[1]['angle']; } // If the feature is at the start point of the second line and start of the second line, return the first line return angles[0]['angle']; } else if (Count(angles) == 3) { // Flatten the angles to ignore direction var flat_angle1 = angles[0]['angle'] % 180; var flat_angle2 = angles[1]['angle'] % 180; var flat_angle3 = angles[2]['angle'] % 180; // Create differences between angles var angle_dif_a = Abs(flat_angle1 - flat_angle2); var angle_dif_b = Abs(flat_angle1 - flat_angle3); var angle_dif_c = Abs(flat_angle2 - flat_angle3); // If difference between line 1 and 2 is below the tolerance, meaning the lines follow the ame plane, return the // third line if (angle_dif_a <= (diff_tol * 2) || angle_dif_a >= (180 - (diff_tol * 2))) { return angles[2]['angle']; } // If difference between line 1 and 3 is below the tolerance, meaning the lines follow the ame plane, return the // second line else if (angle_dif_b <= (diff_tol * 2) || angle_dif_b >= (180 - (diff_tol * 2))) { return angles[1]['angle']; } // If difference between line 2 and 3 is below the tolerance, meaning the lines follow the ame plane, return the // first line else if (angle_dif_c <= (diff_tol * 2) || angle_dif_c >= (180 - (diff_tol * 2))) { return angles[0]['angle']; } // Return first if not covered above return angles[0]['angle']; } // All other cases, the first feature is returned else { return angles[0]['angle']; } | |||||||
7 | 12.6 | 4 | PipelineDevice-GenerateIDs | Generate IDs for PipelineDevice using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:09 | // Assigned To: PipelineDevice // Type: Calculation // Name: PipelineDevice-GenerateIDs // Description: Generate IDs for PipelineDevice using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureBoundary-GenerateIDs // - StructureLine-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineJunction-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Excss-Flw-Vlv", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Excss_Flw_Vlv_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "MTR", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_MTR_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "CTRLlbl-Vlv", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_CTRLlbl_Vlv_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Flw-Vlv", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Flw_Vlv_4_seq'); }else if (selector_value_txt == '5') { id_format = { 'prefix': "Rlf-Vlv", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Rlf_Vlv_5_seq'); }else if (selector_value_txt == '6') { id_format = { 'prefix': "Strnr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Strnr_6_seq'); }else if (selector_value_txt == '8') { id_format = { 'prefix': "Prssr-Mntrng-Dvc", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Prssr_Mntrng_Dvc_8_seq'); }else if (selector_value_txt == '9') { id_format = { 'prefix': "Lmp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Lmp_9_seq'); }else if (selector_value_txt == '10') { id_format = { 'prefix': "Cmprssr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Cmprssr_10_seq'); }else if (selector_value_txt == '11') { id_format = { 'prefix': "Wllhd-Src-Flng", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Wllhd_Src_Flng_11_seq'); }else if (selector_value_txt == '12') { id_format = { 'prefix': "CTRLlbl-T", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_CTRLlbl_T_12_seq'); }else if (selector_value_txt == '13') { id_format = { 'prefix': "Ln-Stppr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Ln_Stppr_13_seq'); }else if (selector_value_txt == '18') { id_format = { 'prefix': "Pmp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Pmp_18_seq'); }else if (selector_value_txt == '19') { id_format = { 'prefix': "REG", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_REG_19_seq'); }else if (selector_value_txt == '20') { id_format = { 'prefix': "Scrbbr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Scrbbr_20_seq'); }else if (selector_value_txt == '50') { id_format = { 'prefix': "And", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_And_50_seq'); }else if (selector_value_txt == '51') { id_format = { 'prefix': "Rctfr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Rctfr_51_seq'); }else if (selector_value_txt == '52') { id_format = { 'prefix': "Tst-Pnt", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Tst_Pnt_52_seq'); }else if (selector_value_txt == '53') { id_format = { 'prefix': "Dcplr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_Dcplr_53_seq'); }else if (selector_value_txt == '54') { id_format = { 'prefix': "GNDng-Pnt", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_D_GNDng_Pnt_54_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.UPDMDevice_P_StrainerInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 487 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineDevice |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMDevice_GlobalID |
Destination Name | main.P_StrainerInspect |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_StrainerInspect |
Backward Path Label | PipelineDevice |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {766DC7F0-3480-44D3-9551-2FC430B5DBA0} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Strainer | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_ContinuousNetwork |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 420 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Continuous Network |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {7C391B5F-ADA0-4BAF-91B7-267AD6F7D3F0} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_ContinuousNetwork is for storing pipeline routes defined using the Continuous Measure method of managing linear referencing information. If the Continuous Measure method for managing linear referencing information is not used, then this feature class is not required for the ArcGIS Pipeline Referencing tools. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
routeid | Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID for the route. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
routename | Route Name | String | True | 0 | 0 | 100 | True | False | The user defined name for the route. This is an optional value. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_87 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ContinuousNetwork_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_SqueezeOff |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 455 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Squeeze Off |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {812F5647-795D-4E6B-8EE1-4E0202649442} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_SqueezeOff describes the location where a squeeze off tool was applied to a polyethylene pipe (Plastic PE). Squeeze off tools are used in operation and emergency situations where the flow through the pipe needs to be temporarily restricted. The purpose of tracking where squeeze offs have been performed on the plastic pipe is to ensure that a single location on the pipe is not subject to the repeated material stress. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
legacyid | LegacyID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
squeezeoffdate | Squeeze Off Date | Date | True | 0 | 0 | 8 | True | False | The date the squeeze off operation occurred. | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | This value defines the angular degrees that the point symbol should be rotated. The purpose is to have the feature's display symbology automatically rotated to the angle defined in this attribute. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_122 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_SqueezeOff_shape | True | True | shape |
Key | Value |
---|---|
Name | main.StructureLine_P_CasingInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 480 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.StructureLine |
Origin Primary Key | GLOBALID |
Origin Foreign Key | STRUCTURELINE_GlobalID |
Destination Name | main.P_CasingInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CasingInspection |
Backward Path Label | StructureLine |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {83115E1F-3147-4378-8A5C-F758309638CD} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Pipe Casing | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_PipelineMarker |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 453 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Pipeline Marker |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {85361A15-B6F6-4606-8DBE-7FF23B0BA50C} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_PipelineMarker an above ground structure used to indicate the location of the buried pipe system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
legacyid | LegacyID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
installationdate | Installation Date | Date | True | 0 | 0 | 8 | True | False | The date the installation of the marker was completed. | |||
markercondition | Marker Condition | String | True | 0 | 0 | 255 | True | False | The general observed condition of the pipeline marker. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
nextinspectiondate | Next Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date when the next inspection is scheduled to be completed. | |||
inspectionduedate | Inspection Due Date | Date | True | 0 | 0 | 8 | True | False | The date when the next inspection id required to be completed. | |||
inspectionfrequency | Inspection Frequency | Short Integer | True | 0 | 0 | 2 | True | False | The interval measured in months required for inspections. | |||
workorderid | Work OrderID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the record was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the record. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this record. | |||
rotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | The numerical value indicating the number of degrees the compressor station should be rotated in a map display. This is typically done to have the symbol match the orientation of the associated pipe segments. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | ||||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | ||||
markernumber | Marker Number | Short Integer | True | 0 | 0 | 2 | True | False | ||||
markertype | Marker Type | Short Integer | True | Pipeline_Marker_Markertype | 0 | 0 | 2 | True | False | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | ||
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | ||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_120 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_PipelineMarker_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_CenterlineAccuracy |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 418 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Centerline Accuracy |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {893F9DCE-B70D-4B6A-A628-C488B0D5AFDB} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_CenterlineAccuracy describes the spatial accuracy of the location of the centerline of the transmission pipe in relation to its actual location on the earth. This is proposed required information for the National Pipeline Mapping System (NPMS). |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_85 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_CenterlineAccuracy_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_DASurveyReadings |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 423 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | DA Survey Readings |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {8E881938-BD71-43E2-96BF-93F40CB856E9} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_DASurveyReadings is intended to store survey readings collected from a direct assessment (DA). |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
datype | Direct Assessment Type | String | True | Pipeline_DA_Survey_Type | 0 | 0 | 50 | True | False | The text value indicating the type of direct assessment performed. Valid values are close interval potential survey, direct current voltage gradient, pipeline current mapper, pearson survey, and alternate current voltage gradient. | ||
inspectiondate | Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date and time of the DA inspection. | |||
pson | PS On | Double | True | 0 | 0 | 8 | True | False | The value number indicating PS on. | |||
psoff | PS Off | Double | True | 0 | 0 | 8 | True | False | The value number indicating PS off. | |||
staticon | Static On | Double | True | 0 | 0 | 8 | True | False | The value number indicating Static on. | |||
staticoff | Static Off | Double | True | 0 | 0 | 8 | True | False | The value number indicating Static off. | |||
dcpotentialvolts | DC Potential Volts | Double | True | 0 | 0 | 8 | True | False | The value number indicating direct current (DC) potential voltage. | |||
acpotentialvolts | AC Potential Volts | Double | True | 0 | 0 | 8 | True | False | The value number indicating alternating current (AC) potential voltage. | |||
pcmcurrent | PCM Current | Double | True | 0 | 0 | 8 | True | False | The value number indicating PCM current. | |||
irpercent | IR Percent | Double | True | 0 | 0 | 8 | True | False | The value number indicating IR percent. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_90 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_DASurveyReadings_shape | True | True | shape |
Key | Value |
---|---|
Name | main.PipelineJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 379 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Pipeline Junction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {901976FD-D504-4792-878D-8A3FBC9D2B91} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Junction class represents locations where lines connect to lines or lines connect to devices. A key use for junction features is to allow devices or lines to connect to another line at an intermediate vertex. You can think of a junction as 'glue point' at key places to connect all the features of a utility network. Junctions can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models general classes of features. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | The discriminator field with a subtype-specific coded domain. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | Indicates the type of utility network association with which the junction feature participates. | |
ISCONNECTED | Is connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | The true/false Boolean value indicating whether the junction is connected to a subnetwork controller source. | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. This is the primary key value for relationships to child tables. | ||
CPSubnetworkName | CP Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name given to the cathodic protection tier subnetwork feature with which the junction feature is associated. | |
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SystemSubnetworkName | System Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name given to the system tier subnetwork feature with which the junction feature is associated. | |
PressureSubnetworkName | Pressure Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name given to the pressure tier subnetwork feature with which the junction feature is associated. | |
IsolationSubnetworkName | Isolation Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the isolation zone tier subnetwork where the record is located. | |
regulatorytype | Regulatory Type | Short Integer | True | Pipeline_Regulatory_Type | 0 | 0 | 0 | 2 | True | False | The value indicating the regulatory status of the junction feature. This is used by the Facility Reporting tools to differentiate between Distribution, Transmission, Offshore Transmission, Gathering, and Offshore Gathering. | |
designtype | Design Type | Short Integer | True | 0 | 0 | 2 | True | False | The design type of the record. | |||
piggable | Piggable | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the junction feature was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the junction feature was put into production. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The layer-specific textual unique identifier. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the junction. In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the junction. In most instances, this will be the name of your organization. | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status | 8 | 0 | 0 | 2 | True | False | The text value indicating the life cycle state of the junction. Coded Value Domain: Pipeline_LifeCycle_Status | |
maopdesign | MAOP Design | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure as defined during design. | |
maoptest | MAOP Test | Double | True | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The tested maximum allowable operating pressure during installation. | |
maoprecord | MAOP Record | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure under which the device feature is currently operating. | |
diameter | Diameter | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the inflow of the fitting orifice. | |||
height | Height | Double | True | 0 | 0 | 8 | True | False | The vertical distance from the ground surface to the highest point on the gas lamp. | |||
measuredlength | Length | Double | True | 0 | 0 | 8 | True | False | The end-to-end distance of the record. | |||
angle | Angle | Double | True | 0 | 0 | 8 | True | False | ||||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | This value defines the angular degrees that the point symbol should be rotated. The purpose is to have the feature's display symbology automatically rotated to the angle defined in this attribute. | ||
barcode | Barcode | String | True | 0 | 0 | 16 | True | False | The ASTM F2897-15 code read from the bar code on the device. | |||
manufacturer | Manufacturer | String | True | 0 | 0 | 2 | True | False | The organization that built the junction feature. | |||
manufacturerlotno | Manufacturer Lot # | Long Integer | True | 0 | 0 | 4 | True | False | The manufacturer lot number from which the record was created. | |||
heatnumber | Heat Number | String | True | 0 | 0 | 38 | True | False | ||||
manufacturedate | Manufacture Date | Date | True | 0 | 0 | 8 | True | False | The date the junction feature was created by the manufacturer. | |||
manufacturecomponent | Manufacture Component | String | True | 0 | 0 | 2 | True | False | The manufacturer-specified, industry standard specification followed when the junction feature was created. | |||
material | Material | String | True | 0 | 0 | 2 | True | False | The primary material used in the manufacture of the junction feature. Coded Value Domain: Pipeline_ASTM_Component_Material | |||
materialspecification | Material Specification | String | True | 0 | 0 | 50 | True | False | ||||
resistanceindicator | Resistance Indicator | Short Integer | True | 0 | 0 | 2 | True | False | ||||
liningtype | Lining Type | String | True | 0 | 0 | 50 | True | False | The type of lining used to cover the interior of the tank to prevent leakage or corrosion. | |||
capacity | Capacity | Double | True | 0 | 0 | 8 | True | False | The maximum volume of gas or liquid that the tank can store. | |||
criticalindicator | Critical Indicator | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the record is considered critical to the operation of the overall system. | |||
flowcapacity | Flow Capacity | Double | True | 0 | 0 | 8 | True | False | The volume-based measurement of the flow of gas through the excess flow valve. | |||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the record. | |||
wallthickness | Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturer defined thickness of the exterior wall of the inflow flow fitting orifice. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the features geometry when the feature is included in the geodatabase. | |||
diameterunits | Diameter Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the diameter of the fitting feature. | |||
wallthicknessunits | Wall Thickness Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the thickness of the outer wall of the fitting feature. | |||
flowcapacityunits | Flow Capacity Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for the volume of flow capacity. | |||
heightunits | Height Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measurement for the value stored in the HEIGHT attribute. | |||
heatingcapacityunits | Heating Capacity Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure of the heating capacity. | |||
lengthunits | Length Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure used to define the inline length of the junction feature. | |||
maopunits | MAOP Unit of Measure | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the maximum allowable operating pressure. | |||
capacityunits | Capacity Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure of the volume of the tank. | |||
installperson | Install Person | String | True | 0 | 0 | 50 | True | False | The name of the person who welded the two segments of pipe together. | |||
installmethod | Install Method | String | True | 0 | 0 | 30 | True | False | The method of welding used to connect the two pipe segments. | |||
rooftype | Roof Type | String | True | 0 | 0 | 50 | True | False | The type of structure used to cover the top of the tank. | |||
heatingfuel | Heating Fuel | String | True | 0 | 0 | 20 | True | False | The fuel used in the line heater to generate heat. | |||
heatingcapacity | Heating Capacity | Double | True | 0 | 0 | 8 | True | False | The manufacturer rated maximum capacity to heat that the line heater is capable of generating. | |||
odoranttype | Odorant Type | String | True | 0 | 0 | 30 | True | False | The type of chemical used to provide odor to the gas stream. | |||
percentgraph | Percent Graph | Double | True | 0 | 0 | 8 | True | False | The percent of graphitization. | |||
bondjunctiontype | Bond Junction Type | String | True | 0 | 0 | 35 | True | False | The type of bonding of the CP wire to the fitting. | |||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsz | GPS Z | Double | True | 0 | 0 | 8 | True | False | The elevation coordinate of the feature when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this junction feature. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the junction feature. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the junction feature was installed. | |||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each event record. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the event became active on the route. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the event was retired from the route. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The unique name of the engineering network route where the event is located. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the junction is located. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value isautomatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset feature. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point feature class. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting feature. This can be Coordinates, Feature/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the junction features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
bondedinsulated | Bonded/Insulated | Short Integer | True | Bonded_Insulated | 0 | 0 | 2 | True | False | A Boolean indicator of whether the fitting acts as a conductive fitting (bonded) or an non-conductive fitting (insulated) in a cathodic protection system. Coded Valve Domain: Bonded_Insulated. | ||
cptraceability | Cathodic Protection Traceability | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | A Boolean indicator of whether the normal function of the fitting is traceable in a cathodic protection zone. Coded Value Domain: CP_Traceability | ||
cpoverride | CP Override | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | A Boolean indicator of a temporary state of whether the fitting is traceable in a cathodic protection zone. Coded Valve Domain: CP_Traceability | ||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | A description of the location of the record. | |||
wallthickness2 | Wall Thickness 2 | Double | True | 0 | 0 | 8 | True | False | The manufacturer's defined thickness of the exterior wall of the record. | |||
diameter2 | Diameter 2 | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the center of the downstream record. | |||
rating | Rating | Double | True | 0 | 0 | 8 | True | False | The manufacturer certified maximum operating pressure for which the device can operate. | |||
fittingspecification | Fitting Specification | String | True | 0 | 0 | 30 | True | False | ||||
xraynumber | X-Ray Number | String | True | 0 | 0 | 20 | True | False | The unique identifier of the X-Ray picture taken as part of the weld certification. | |||
jointcoatingtype | Joint Coating Type | Short Integer | True | 0 | 0 | 2 | True | False | The type of coating applied to the joint. | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_379_CPSubnet | False | True | CPSubnetworkName |
GDB_379_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_379_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_379_SystemSu | False | True | SystemSubnetworkName |
GDB_379_Pressure | False | True | PressureSubnetworkName |
GDB_379_Isolatio | False | True | IsolationSubnetworkName |
UUID_46 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__PipelineJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Coupling | 1 | The subtype feature layer Coupling describes those inline assets used for connecting two pipe segments of the same diameter and material. |
Elbow | 2 | The subtype feature layer Elbow describes those inline assets used for connecting two pipe segments with an offset angle of the same diameter and material. |
End Cap | 3 | The subtype feature layer End Cap describes inline assets used for sealing the end of a pipe segment. |
Expansion Joint | 4 | The subtype feature layer Expansion Joint describes inline assets used for connecting pipe segments and to safely absorb pipe system expansion, contraction, and vibration. |
Flange | 5 | The subtype feature layer Flange describes inline assets used for connecting pipe segments. A flange has an internal or external rim to provide additional strength. |
Reducer | 6 | The subtype feature layer Reducer describes inline assets used for connecting pipe segments of different diameter. |
Tee | 7 | The subtype feature layer Tee describes inline assets used for connecting three or four pipe segments. |
Transition | 8 | The subtype feature layer Transition describes inline assets used for connecting pipe segments of different materials. |
Weld | 9 | The subtype feature layer Weld describes a method for connecting two pipe segments of metallic material. |
Screw | 10 | The subtype feature layer Screw describes an inline asset with screw threads for connecting two pipe segments of metallic material. |
Electro Stop | 11 | The subtype feature layer Electro Stop describes an inline asset that acts as an insulator of electric current. |
Plastic Fusion | 12 | The subtype feature layer Plastic Fusion describes the location where two plastic pipes and/or components are connected with an electro fusion device. |
Saddle | 13 | The subtype feature layer Saddle describes junction assets used for connecting pipe segments. Saddles perform a variety of purposes, such as tapping and structural strengthening. |
Tank | 14 | The subtype feature layer Tank describes the facility in a transmission pipeline used as a storage unit to relieve surges in flow or to receive and store liquid or gas for reinjection and continued transportation through the pipeline. |
Line Heater | 15 | The subtype feature layer Line Heater describes the component in a pipeline that has the ability to elevate the temperature of liquid/gas to prevent hydrate formation. |
Cooling System | 16 | The subtype feature layer Cooling System describes the component in a pipeline that has the ability to reduce the temperature of the liquid/gas commodity. |
Odorizer | 17 | The subtype feature layer Odorizer describes the component for injecting odorant into the gas pipe system. US DOT regulation CFR 49 part 192.625 requires that gas pipelines contain enough odorant so that the gas is readily detectable by a person with a normal sense of smell. |
Coupon | 18 | The subtype feature layer Coupon describes the location where a sample of the pipe is cut from the metal pipe to determine the extent of internal corrosion. |
Dehydration Equipment | 19 | The subtype feature layer Dehydration Equipment describes the component that is responsible for inhibiting the formation of hydrates in the pipeline. |
Drip | 20 | The subtype feature layer Drip describes the component in a gas pipeline that helps to separate and collect water that has accumulated in the pipeline. |
Connection Point | 21 | The subtype feature layer Connection Point describes the location along a pipe segment where a structure junction connects to a non-endpoint location along the pipe via a structural attachment. |
Union | 23 | |
Plug | 24 | |
Tap | 25 | |
Pipe Bend | 30 | |
Wire Junction | 50 | The subtype feature layer Wire Junction describes the component where multiple wires meet and interconnect. |
Insulation Junction | 51 | The subtype feature layer Insulation Junction describes the component which stops the flow of electricity through the cathodic protection zone. |
Olet | 26 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
9 | 12.7 | 1 | Junction - Auto Contain By Rules | Auto contain pipeline junctions. Uses the rule table to contain feature in a container within a search distance | Calculation | False | True | True | False | True | False | True | 2024-04-26 11:19:13 | // Assigned To: PipelineJunction // Type: Calculation // Name: Junction - Auto Contain By Rules // Description: Auto contain pipeline junctions. Uses the rule table to contain feature in a container within a search distance // Subtypes: All // Trigger: Insert, Update // Exclude From Client: True // Disable: True // Implementation Note: This rule is disabled by default as it auto performs containment of features when editing. If you desire these functions, enable this rule and adjust the settings below. // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Auto Contain By Rules // - Junction - Auto Contain By Rules // - Line - Auto Contain By Rules // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // The subtype and asset type fields of $feature // ** Implementation Note: These fields are used to determine what Container associations are possible from the Rules table. var assetgroup = $feature.assetgroup var assettype = $feature.assettype // The association status field, this field is maintained by the utility network // ** Implementation Note: Do not change this value, it is in this section in case there is a schema change to the utility network in the future. var association_status = $feature.associationstatus; // The distance to search for a container // ** Implementation Note: Adjust this value based on the distance to auto contain, the comment after the value is an example how to use a // field to defined the distance, this field does not exist in the data model, but could be added to provide a data specific distance. var search_distance = 40; //DefaultValue($feature.searchdistance, 40); // The unit of the distance value in search_distance. // ** Implementation Note: Set the distance to search, for unit codes - https://desktop.arcgis.com/en/arcobjects/latest/net/webframe.htm#esriSRUnitType.htm var search_unit = 9002; // The utility network class ID for each layer. // ** Implementation Note: Adjust these values to match your geodatabase. The values defined below are for a Version 4 // utility network with only the schema provide(no additional domain networks) // These values will change with a version 3 utility network or if you applied more than one domain to the same utility network. // To review these values, open the attribute domains in the database with the utility network and search for FeatureSourceID. This domain // will list the class id by un domain alias, not class name, so you will have to related the un attribute domain to the gdb class name to match its ID function class_id_to_name(id) { return Decode(Text(id), "1", "Association", "2", "SystemJunction", "3", "SystemJunctionObject", "4", "StructureJunction", "5", "StructureLine", "6", "StructureBoundary", "7", "StructureJunctionObject", "8", "StructureEdgeObject", "9", "PipelineDevice", "10", "PipelineLine", "11", "PipelineAssembly", "12", "PipelineJunction", "13", "PipelineSubnetLine", "14", "PipelineJunctionObject", "15", "PipelineEdgeObject", null) } // monikerize FeatureSetByName function var get_features_switch_yard = FeatureSetByName; // A function to determine if the edit is triggered by UpdateSubnetwork. If a filegeodatbase, this action triggers an edit event, if enterprise, triggering the event is optional // ** Implementation Note: If using the industry model with all tiers, no change is required. If a tier was removed, remove the matching if block. function is_edit_from_subnetwork() { if ($feature.systemsubnetworkname != $originalfeature.systemsubnetworkname) { return true; } if ($feature.pressuresubnetworkname != $originalfeature.pressuresubnetworkname) { return true; } if ($feature.isolationsubnetworkname != $originalfeature.isolationsubnetworkname) { return true; } if ($feature.cpsubnetworkname != $originalfeature.cpsubnetworkname) { return true; } return false; } // ************* End User Variables Section ************ // ************* Functions ************* function geometry_change() { if (IsEmpty($originalfeature)) { return true; } if (IsEmpty(Geometry($originalfeature))) { return true; } return !Equals(Geometry($feature), Geometry($originalfeature)); } function sortCandidates(a, b) { if (a['distance'] < b['distance']) return -1; if (a['distance'] > b['distance']) return 1; return 0; } function build_containers_info() { var rule_fields = ['OBJECTID', 'RULETYPE', 'FROMNETWORKSOURCEID', 'FROMASSETGROUP', 'FROMASSETTYPE', 'TOASSETGROUP', 'TOASSETTYPE', 'GLOBALID'] var rules_fs = get_features_switch_yard($datastore, 'UN_6_Rules', rule_fields, false); var containers_rows = Filter(rules_fs, 'RULETYPE = 2 and TOASSETGROUP = @assetgroup and TOASSETTYPE = @assettype'); var container_row_count = Count(containers_rows) if (container_row_count == 0) { return null; } var container_class_types = {}; for (var container_row in containers_rows) { var class_name = class_id_to_name(container_row['FROMNETWORKSOURCEID']); if (IsEmpty(class_name)) { return {'errorMessage': 'Unable to translate Class ID to Class, attribute rules needs updating'}; } if (HasKey(container_class_types, class_name) == false) { container_class_types[class_name] = {}; } var asset_group = Text(container_row['FROMASSETGROUP']) if (HasKey(container_class_types[class_name], asset_group) == false) { container_class_types[class_name][asset_group] = []; } var asset_type = Text(container_row['FROMASSETTYPE']) if (IndexOf(container_class_types[class_name][asset_group], asset_type) == -1) { push(container_class_types[class_name][asset_group], asset_type) } } return container_class_types } function build_sql(container_info, feat_global_id) { var sql_class = []; var i = 0; for (var cls in container_info) { var sub_where = []; var k = 0; for (var ag in container_info[cls]) { sub_where[k++] = "(AssetGroup = " + ag + " AND AssetType IN (" + Concatenate(container_info[cls][ag], ',') + '))' } sql_class[i++] = [cls, '(' + Concatenate(sub_where, ' OR ') + ") and GLOBALID <> '" + feat_global_id + "'"]; } return sql_class } function generate_candidates(feature, sql_by_class, search_shape) { var container_candidate = []; var k = 0; for (var i = 0; i < Count(sql_by_class); i++) { var class_name = sql_by_class[i][0]; var where = sql_by_class[i][1]; var fs = get_features_switch_yard($datastore, class_name, ['GLOBALID'], false); var container_features = Filter(Intersects(fs, search_shape), where); var cont_feat_count = Count(container_features); if (cont_feat_count > 0) { for (var feat in container_features) { container_candidate[k++] = { 'class_name': class_name, 'globalid': feat.globalid, 'distance': Distance(feature, feat, 9002) } } } } return container_candidate; } // ************* End Functions Section ***************** // in FGDB, update subnetwork triggers an update operations, exit if (!($editContext.editType=='INSERT') && is_edit_from_subnetwork()) { return; } // If the geometry did not change on an update, return if (!($editContext.editType=='INSERT') && !geometry_change()) { return; } // If the feature is already content, return if ((association_status & 0x14) > 0) { return; } var container_info = build_containers_info(); if (IsEmpty(container_info)) { return; } if (TypeOf(container_info) == 'Dictionary') { if (HasKey(container_info, 'errorMessage')) { return container_info; } } var sql_by_class = build_sql(container_info, $feature.globalid); var search_shape = Buffer(Geometry($feature), search_distance, search_unit); var candidates = generate_candidates($feature, sql_by_class, search_shape) if (Count(candidates) == 0) { return; } var sorted_candidates = Sort(candidates, sortCandidates); var edit_payload = [{ 'className': sorted_candidates[0]['class_name'], 'updates': [{ 'globalID': sorted_candidates[0]['globalid'], 'associationType': 'container' }] }]; return {"edit": edit_payload}; | ||||||||
10 | 12.7 | 2 | Junction - Cathodic Protection Traceability | Cathodic Protection Traceability for Pipeline Junctions. Set traceability flag for junction assets | Calculation | False | True | True | False | cptraceability | True | True | False | 2024-04-26 11:19:13 | // Assigned To: PipelineJunction // Type: Calculation // Name: Junction - Cathodic Protection Traceability // Description: Cathodic Protection Traceability for Pipeline Junctions. Set traceability flag for junction assets // Subtypes: All // Field: cptraceability // Trigger: Insert, Update // Exclude From Client: False // Disable: False // Is Editable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Cathodic Protection Traceability // - Junction - Cathodic Protection Traceability // - Line - Cathodic Protection Traceability // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the CP information // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.cptraceability; var cp_override = $feature.cpoverride; var cp_bondedinsulated = $feature.bondedinsulated; // Field in the data model used to store and manage the material details // ** Implementation Note: This value does not need to change if using the industry data model var cp_material = $feature.assettype; // The list of material types that are conductive from the assettype field and the asset type domains // ** Implementation Note: These do not need to be adjusted unless the value of the asset type attribute domains were changed. var conductive_materials = [1, 41, 81, 161, 201, 241, 242, 321, 341, 481]; // The list of material types that are not conductive from the assettype field and the asset type domains // ** Implementation Note: These do not need to be adjusted unless the value of the asset type attribute domains were changed. var non_conductive_materials = [2, 42, 82, 202, 243, 244, 401, 441, 482, 941]; // Limit the rule to valid asset groups/subtypes // ** Implementation Note: Instead of recreating this rule for each subtype, this rules uses a list of subtypes and exits if not valid // If you have added Asset Groups, they will need to be added to this list. var valid_asset_groups = [1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 23, 24, 25, 30, 50, 51]; // List of asset groups that are always included in a CP trace. // ** Implementation Note: If you have extended the CP model for additional asset groups, those asset groups should be added here var asset_groups_always_traceability = [50]; // List of asset groups that are always not include in a CP trace and are CP barriers. // ** Implementation Note: If you have extended the pipe model for additional asset groups that never conduct cp current, those asset groups should be added here var asset_groups_never_traceability = [51]; // Values to determine traceability // ** Implementation Note: These do not need to be adjusted unless the values of the CP_Traceability attribute domain were changed. var traceable = 1; // Also used for Bonded var not_traceable = 2; // Also used for Insulated // ************* End User Variables Section ************* if (!Includes(valid_asset_groups, $feature.assetgroup) == -1) { return assigned_to_field; } // If an override is specified, use that value regardless of other attributes if (cp_override > 0) { return cp_override; } // If a device is always traceability or not, regardless of material, return the proper status if (Includes(asset_groups_always_traceability, $feature.assetgroup)) { return traceable; } if (Includes(asset_groups_never_traceability, $feature.assetgroup)) { return not_traceable; } // If a value is set on the bonded, insulated field, return that value if (!IsEmpty(cp_bondedinsulated) && cp_bondedinsulated > 0) { return cp_bondedinsulated; } // Check if the material is conductive if (Includes(conductive_materials, cp_material)) { return traceable; } if (Includes(non_conductive_materials, cp_material)) { return not_traceable; } //Return the value in the field when no other condition is met return assigned_to_field; | |||||||
11 | 12.7 | 3 | Junction - Symbol Rotation | Rotate Pipeline Devices to match intersecting Line. Intersects a line layer and based on the number of intersected features, calculates the angle for the point | Calculation | False | True | True | False | symbolrotation | True | True | True | 2024-04-26 11:19:13 | // Assigned To: PipelineJunction // Type: Calculation // Name: Junction - Symbol Rotation // Description: Rotate Pipeline Devices to match intersecting Line. Intersects a line layer and based on the number of intersected features, calculates the angle for the point // Subtypes: All // Field: symbolrotation // Trigger: Insert, Update // Exclude From Client: False // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Symbol Rotation // - Junction - Symbol Rotation // ************* User Variables ************* // Field in the data model used to store and manage the rotation of the feature // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.symbolrotation; // Set to true if the rotation setting is set to geographic in the layer properties // ** Implementation Note: This value does not need to change if using the industry maps var geographic_rotation = false; // Set the counter clockwise spin angle used for the symbol in the symbology options // ** Implementation Note: This value does not need to change if using the industry maps var symbol_flip_angle = 0 // Name of the Line layer to intersect // ** Implementation Note: This value does not need to change if using the industry maps var pipeline = "PipelineLine" // ************* End User Variables Section ************ // Return if a value is already set, to recalculate an angle, the field must be set to null if (!IsEmpty(assigned_to_field)) { return assigned_to_field; } // monikerize FeatureSetByName function var get_features_switch_yard = FeatureSetByName; // Create a feature set to the line layer var lineClass = get_features_switch_yard($datastore, "PipelineLine", ["objectid"], true); // Find the intersecting lines var lines = Intersects(lineClass, $feature); //If no lines intersect, return the original value if (Count(lines) == 0) { return assigned_to_field; } var diff_tol = 5; // Variable to store all found angles var angles = []; // Store the features geometry var feature_geometry = Geometry($feature); // Loop over all intersecting lines and find their angles var angle_type; var angle_value; for (var line in lines) { // Buffer and create an extent of the point by a small amount to extract the segment var clip_area = Extent(Buffer($feature, .01, "meter")); // Clip the line by the extent and get the first line segment var segment = Clip(line, clip_area)["paths"][0]; // The features location is on the start of the line, get the angle from the feature to the end vertex if (Equals(segment[0], feature_geometry)) { angle_type = 'from' angle_value = Round(Angle(feature_geometry, segment[-1]), 0) } // The features location is on the end of the line, create a new segment from the feature to the start vertex else if (Equals(segment[-1], feature_geometry)) { angle_type = 'to' angle_value = Round(Angle(feature_geometry, segment[0]), 0) } // The features location is midspan of the segment, use the angle of the segment else { angle_type = 'mid' angle_value = Round(Angle(segment[0], segment[-1]), 0) } if (geographic_rotation == true) { // Convert Arithmetic to Geographic angle_value = (450 - angle_value) % 360; } // Add 180 to match 0 rotation in the TOC // Add user specified spin angle if their symbol is rotated angle_value = (angle_value + 180 + symbol_flip_angle) % 360; push(angles, {'angle': angle_value, 'type': angle_type}); } // If only one angle, return that value if (Count(angles) == 1) { // If the point is midspan, flip to match symbol as it if was on the end point if (angles[0]['type'] == 'mid') { return (angles[0]['angle'] + 180) % 360; } return angles[0]['angle']; } else if (Count(angles) == 2) { // If the feature is midspan of the first line, return the angle of the second line if (angles[0]['type'] == 'mid') return angles[1]['angle']; // If the feature is midspan of the second line, return the angle of the first line else if (angles[1]['type'] == 'mid') return angles[0]['angle']; // If the feature is at the end point of both lines, return the angle of the first line else if (angles[0]['type'] == 'to' && angles[1]['type'] == 'to') { return angles[0]['angle']; } // If the feature is at the start point of both lines, return the angle of the first line else if (angles[0]['type'] == 'from' && angles[1]['type'] == 'from') { return angles[0]['angle']; } // If the feature is at the start point of the first line and end of the second line, return the second line else if (angles[0]['type'] == 'from') { return angles[1]['angle']; } // If the feature is at the start point of the second line and start of the second line, return the first line return angles[0]['angle']; } else if (Count(angles) == 3) { // Flatten the angles to ignore direction var flat_angle1 = angles[0]['angle'] % 180; var flat_angle2 = angles[1]['angle'] % 180; var flat_angle3 = angles[2]['angle'] % 180; // Create differences between angles var angle_dif_a = Abs(flat_angle1 - flat_angle2); var angle_dif_b = Abs(flat_angle1 - flat_angle3); var angle_dif_c = Abs(flat_angle2 - flat_angle3); // If difference between line 1 and 2 is below the tolerance, meaning the lines follow the ame plane, return the // third line if (angle_dif_a <= (diff_tol * 2) || angle_dif_a >= (180 - (diff_tol * 2))) { return angles[2]['angle']; } // If difference between line 1 and 3 is below the tolerance, meaning the lines follow the ame plane, return the // second line else if (angle_dif_b <= (diff_tol * 2) || angle_dif_b >= (180 - (diff_tol * 2))) { return angles[1]['angle']; } // If difference between line 2 and 3 is below the tolerance, meaning the lines follow the ame plane, return the // first line else if (angle_dif_c <= (diff_tol * 2) || angle_dif_c >= (180 - (diff_tol * 2))) { return angles[0]['angle']; } // Return first if not covered above return angles[0]['angle']; } // All other cases, the first feature is returned else { return angles[0]['angle']; } | |||||||
12 | 12.6 | 4 | PipelineJunction-GenerateIDs | Generate IDs for PipelineJunction using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:13 | // Assigned To: PipelineJunction // Type: Calculation // Name: PipelineJunction-GenerateIDs // Description: Generate IDs for PipelineJunction using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureBoundary-GenerateIDs // - StructureLine-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineLine-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "Cplng", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Cplng_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "ELL", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_ELL_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "End-Cp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_End_Cp_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Expnsn-Jnt", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Expnsn_Jnt_4_seq'); }else if (selector_value_txt == '5') { id_format = { 'prefix': "Flng", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Flng_5_seq'); }else if (selector_value_txt == '6') { id_format = { 'prefix': "Rdcr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Rdcr_6_seq'); }else if (selector_value_txt == '7') { id_format = { 'prefix': "T", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_T_7_seq'); }else if (selector_value_txt == '8') { id_format = { 'prefix': "Trnstn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Trnstn_8_seq'); }else if (selector_value_txt == '9') { id_format = { 'prefix': "Wld", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Wld_9_seq'); }else if (selector_value_txt == '10') { id_format = { 'prefix': "Scrw", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Scrw_10_seq'); }else if (selector_value_txt == '11') { id_format = { 'prefix': "Elctr-Stp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Elctr_Stp_11_seq'); }else if (selector_value_txt == '12') { id_format = { 'prefix': "Plstc-FSn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Plstc_FSn_12_seq'); }else if (selector_value_txt == '13') { id_format = { 'prefix': "Sddl", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Sddl_13_seq'); }else if (selector_value_txt == '14') { id_format = { 'prefix': "Tnk", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Tnk_14_seq'); }else if (selector_value_txt == '15') { id_format = { 'prefix': "Ln-Htr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Ln_Htr_15_seq'); }else if (selector_value_txt == '16') { id_format = { 'prefix': "Clng-Systm", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Clng_Systm_16_seq'); }else if (selector_value_txt == '17') { id_format = { 'prefix': "Odrzr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Odrzr_17_seq'); }else if (selector_value_txt == '18') { id_format = { 'prefix': "Cpn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Cpn_18_seq'); }else if (selector_value_txt == '19') { id_format = { 'prefix': "Dhydrtn-Eqpmnt", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Dhydrtn_Eqpmnt_19_seq'); }else if (selector_value_txt == '20') { id_format = { 'prefix': "Drp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Drp_20_seq'); }else if (selector_value_txt == '21') { id_format = { 'prefix': "CPT", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_CPT_21_seq'); }else if (selector_value_txt == '23') { id_format = { 'prefix': "Unn", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Unn_23_seq'); }else if (selector_value_txt == '24') { id_format = { 'prefix': "Plg", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Plg_24_seq'); }else if (selector_value_txt == '25') { id_format = { 'prefix': "Tp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Tp_25_seq'); }else if (selector_value_txt == '30') { id_format = { 'prefix': "Pp-Bnd", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Pp_Bnd_30_seq'); }else if (selector_value_txt == '50') { id_format = { 'prefix': "Wr-JCT", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Wr_JCT_50_seq'); }else if (selector_value_txt == '51') { id_format = { 'prefix': "Insltn-JCT", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_J_Insltn_JCT_51_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id |
Key | Value |
---|---|
Name | main.P_DocumentPoint |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 425 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Document Point |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {94C09CB3-676C-4920-8818-47852C3DAF98} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_DocumentPoint is intended to store points that are used to link one or more external documents to a location. P_DocumentPoint features can be used to annotate (with supporting documents) features that are not explicitly defined in the geodatabase. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
documenttype | Document Type | String | True | Pipeline_Document_Type | 0 | 0 | 30 | True | False | The text value indicating the type of document. Valid values are Adobe Acrobat (.pdf), AutoCAD drawing (.dwg), bitmap (.bmp), GIF (.gif), HTML (.htm), JPEG (.jpg), Microsoft Excel (.xls), Microsoft Word (.doc), text (.txt), TIFF (.tif), and MicroStation drawing (.dgn). | ||
documentdescription | Document Description | String | True | 0 | 0 | 255 | True | False | The textual description of the document. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_92 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_DocumentPoint_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_ILIGroundRefMarkers |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 435 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | ILI Ground Ref Markers |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {98C11E7B-668D-4694-93BE-68B52255F8A6} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_ILIGroundRefMarkers describes reference markers in the pipeline system as detected from inline inspection (ILI) runs of a pigging device. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
markertype | Marker Type | String | True | Pipeline_ILI_Survey_Marker_Type | 0 | 0 | 50 | True | False | The text value indicating the type of marker detected. Valid values are AGR Timer Box, AGR Valve, Monument, Crossing, and Other. | ||
altrference | Alternative Reference | String | True | 0 | 0 | 50 | True | False | The alternative reference of the feature detected from the inline inspection. | |||
chainagesource | Water Elevation | String | True | 0 | 0 | 50 | True | False | The source of the chainage distance recorded from inline inspection. | |||
location | Location | String | True | 0 | 0 | 50 | True | False | The textual description of the feature location detected from inline inspection. | |||
offsetdist | Offset | Double | True | 0 | 0 | 8 | True | False | The perpendicular linear distance of the marker from the pipeline. | |||
offsetunits | Offset Units | Short Integer | True | Units_for_Length | 0 | 0 | 2 | True | False | The unit of measure for offset. | ||
referencenumber | Reference Number | String | True | 0 | 0 | 50 | True | False | The reference number assigned to the feature detected from inline inspection. | |||
rundistance | Run Distance | Double | True | 0 | 0 | 8 | True | False | The run distance of the feature detected by the pigging device. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the feature detected from inline inspection. | |||
inspectionrange_globalid | Inspection Range GlobalID | GUID | True | 0 | 0 | 38 | True | False | The inspection range feature class column containing the matching primary key value for relationships to associated components. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_102 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ILIGroundRefMarkers_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_IdentifiedIssue |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 439 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Identified Issue |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {9A19AC7F-6897-4EE4-BC54-D87C4C6507F3} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_IdentifiedIssue describes pipe system anomalies that were identified by the field technician. Some examples of identified issues are corrosion, damaged meter, and dead vegetation. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
issue | Issue | String | True | Pipeline_Identified_Issue | 0 | 0 | 50 | True | False | The type of issue identified by the field technician. | ||
datereported | Date Reported | Date | True | 0 | 0 | 8 | True | False | The date the field technician identified the issue. | |||
reportedby | Reported By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who identified the issue. | |||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Additional information provided by the field technician about the identified issue. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_106 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_IdentifiedIssue_shape | True | True | shape |
Key | Value |
---|---|
Name | main.UPDMDevice_P_RegulatorInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 486 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineDevice |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMDevice_GlobalID |
Destination Name | main.P_RegulatorInspect |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_RegulatorInspect |
Backward Path Label | PipelineDevice |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {9B58B5FC-63C2-4079-9BDA-DDA429AA55C8} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Regulator | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.Network |
Dataset Type | UtilityNetwork |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 6 |
Schema Generation | 7 |
Pro Version | ArcGIS Pro 3.3.0 |
User Identity | |
Creation Time | 2024-04-26 11:12:44 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Service Territory | main.ServiceTerritory |
Domain Network Name | Domain Network Alias | Domain Network ID | Tier Definition | Subnetwork Controller Type | Creation Time |
---|---|---|---|---|---|
Structure | Structure | 1 | None | 2024-04-26 11:12:44 | |
Pipeline | Pipeline | 2 | Hierarchical | Source | 2024-04-26 11:14:08 |
Domain Network Name | Tier Group Name | Creation Time |
---|---|---|
Pipeline | CathodicProtectionCoverage | 2024-04-26 11:14:16 |
Pipeline | System | 2024-04-26 11:14:16 |
Domain Network Name | Tier Group Name | Tier Name | Tier ID | Tier Rank | Tier Topology | Diagram Templates | Supports Disjoint | Subnetwork Field Name | Edit Mode in Default | Edit Mode in Version | Update Structures | Update Containers | Validate Locatability | Manage isDirty | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipeline | CathodicProtectionCoverage | Cathodic Protection | 1 | 1 | Mesh | True | CPSubnetworkName | Without Eventing | Without Eventing | False | False | False | False | 2024-04-26 11:14:16 | |
Pipeline | System | System | 2 | 1 | Mesh | True | SystemSubnetworkName | Without Eventing | Without Eventing | False | False | False | False | 2024-04-26 11:14:16 | |
Pipeline | System | Pressure | 3 | 2 | Mesh | True | PressureSubnetworkName | Without Eventing | Without Eventing | False | False | False | False | 2024-04-26 11:14:16 | |
Pipeline | System | Isolation | 4 | 3 | Mesh | True | IsolationSubnetworkName | Without Eventing | Without Eventing | False | False | False | False | 2024-04-26 11:14:16 |
Tier Name | Source Name | Asset Group | Asset Type | Controller / Aggregated |
---|---|---|---|---|
Cathodic Protection | Device | Lamp | Unknown | False |
Cathodic Protection | Device | Lamp | Lamp | False |
Cathodic Protection | Device | Excess Flow Valve | Unknown | False |
Cathodic Protection | Device | Excess Flow Valve | Automatic Reset | False |
Cathodic Protection | Device | Excess Flow Valve | Manual Reset | False |
Cathodic Protection | Device | Excess Flow Valve | Breakaway Fitting | False |
Cathodic Protection | Device | Meter | Unknown | False |
Cathodic Protection | Device | Meter | Custody Transfer | False |
Cathodic Protection | Device | Meter | Customer | False |
Cathodic Protection | Device | Meter | Utility | False |
Cathodic Protection | Device | Controllable Valve | Unknown | False |
Cathodic Protection | Device | Controllable Valve | Bypass | False |
Cathodic Protection | Device | Controllable Valve | Emergency | False |
Cathodic Protection | Device | Controllable Valve | System | False |
Cathodic Protection | Device | Controllable Valve | Meter | False |
Cathodic Protection | Device | Flow Valve | Unknown | False |
Cathodic Protection | Device | Flow Valve | Check | False |
Cathodic Protection | Device | Flow Valve | Slam-shut | False |
Cathodic Protection | Device | Relief Valve | Unknown | False |
Cathodic Protection | Device | Relief Valve | Blow Off | False |
Cathodic Protection | Device | Relief Valve | Flare | False |
Cathodic Protection | Device | Relief Valve | Over Pressure Protection | False |
Cathodic Protection | Device | Relief Valve | Vacuum Pressure Protection | False |
Cathodic Protection | Device | Relief Valve | Over Pressure and Vacuum Pressure Protection | False |
Cathodic Protection | Device | Strainer | Unknown | False |
Cathodic Protection | Device | Strainer | Strainer | False |
Cathodic Protection | Device | Pressure Monitoring Device | Unknown | False |
Cathodic Protection | Device | Pressure Monitoring Device | Pressure Monitoring Device | False |
Cathodic Protection | Device | Compressor | Unknown | False |
Cathodic Protection | Device | Compressor | Electric Motor | False |
Cathodic Protection | Device | Compressor | Reciprocating Engine | False |
Cathodic Protection | Device | Compressor | Turbine | False |
Cathodic Protection | Device | Wellhead Source Flange | Unknown | False |
Cathodic Protection | Device | Wellhead Source Flange | Flange | False |
Cathodic Protection | Device | Controllable Tee | Unknown | False |
Cathodic Protection | Device | Controllable Tee | Controllable Tee | False |
Cathodic Protection | Device | Line Stopper | Unknown | False |
Cathodic Protection | Device | Line Stopper | Line Stopper | False |
Cathodic Protection | Device | Pump | Unknown | False |
Cathodic Protection | Device | Pump | Booster | False |
Cathodic Protection | Device | Pump | Primary | False |
Cathodic Protection | Device | Regulator | Unknown | False |
Cathodic Protection | Device | Regulator | Regulator | False |
Cathodic Protection | Device | Regulator | Customer Regulator | False |
Cathodic Protection | Device | Scrubber | Unknown | False |
Cathodic Protection | Device | Scrubber | Scrubber | False |
Cathodic Protection | Device | Anode | Unknown | False |
Cathodic Protection | Device | Anode | ICCP | False |
Cathodic Protection | Device | Anode | Galvanic | False |
Cathodic Protection | Device | Rectifier | Unknown | False |
Cathodic Protection | Device | Rectifier | Rectifier | False |
Cathodic Protection | Device | Test Point | Unknown | False |
Cathodic Protection | Device | Test Point | Above Ground | True |
Cathodic Protection | Device | Test Point | Buried | True |
Cathodic Protection | Device | Test Point | On Post | True |
Cathodic Protection | Device | Test Point | Pipeline Marker | True |
Cathodic Protection | Device | Test Point | Service Line | True |
Cathodic Protection | Device | Decoupler | Unknown | False |
Cathodic Protection | Device | Decoupler | AC Decoupler | False |
Cathodic Protection | Device | Decoupler | DC Decoupler | False |
Cathodic Protection | Device | Grounding Point | Unknown | False |
Cathodic Protection | Device | Grounding Point | Grounding Point | False |
Cathodic Protection | Line | Service Pipe | Unknown | False |
Cathodic Protection | Line | Service Pipe | Bare Steel | False |
Cathodic Protection | Line | Service Pipe | Cast Iron | False |
Cathodic Protection | Line | Service Pipe | Coated Steel | False |
Cathodic Protection | Line | Service Pipe | Composite | False |
Cathodic Protection | Line | Service Pipe | Copper | False |
Cathodic Protection | Line | Service Pipe | Ductile Iron | False |
Cathodic Protection | Line | Service Pipe | Plastic ABS | False |
Cathodic Protection | Line | Service Pipe | Plastic Other | False |
Cathodic Protection | Line | Service Pipe | Plastic PE | False |
Cathodic Protection | Line | Service Pipe | Plastic PVC | False |
Cathodic Protection | Line | Service Pipe | Reconditioned Cast Iron | False |
Cathodic Protection | Line | Service Pipe | Wrought Iron | False |
Cathodic Protection | Line | Distribution Pipe | Unknown | True |
Cathodic Protection | Line | Distribution Pipe | Bare Steel | True |
Cathodic Protection | Line | Distribution Pipe | Cast Iron | True |
Cathodic Protection | Line | Distribution Pipe | Coated Steel | True |
Cathodic Protection | Line | Distribution Pipe | Composite | True |
Cathodic Protection | Line | Distribution Pipe | Copper | True |
Cathodic Protection | Line | Distribution Pipe | Ductile Iron | True |
Cathodic Protection | Line | Distribution Pipe | Plastic ABS | True |
Cathodic Protection | Line | Distribution Pipe | Plastic Other | True |
Cathodic Protection | Line | Distribution Pipe | Plastic PE | True |
Cathodic Protection | Line | Distribution Pipe | Plastic PVC | True |
Cathodic Protection | Line | Distribution Pipe | Reconditioned Cast Iron | True |
Cathodic Protection | Line | Distribution Pipe | Wrought Iron | True |
Cathodic Protection | Line | Transmission Pipe | Unknown | True |
Cathodic Protection | Line | Transmission Pipe | Bare Steel | True |
Cathodic Protection | Line | Transmission Pipe | Cast Iron | True |
Cathodic Protection | Line | Transmission Pipe | Coated Steel | True |
Cathodic Protection | Line | Transmission Pipe | Composite | True |
Cathodic Protection | Line | Transmission Pipe | Ductile Iron | True |
Cathodic Protection | Line | Transmission Pipe | Reconditioned Cast Iron | True |
Cathodic Protection | Line | Transmission Pipe | Wrought Iron | True |
Cathodic Protection | Line | Gathering Pipe | Unknown | True |
Cathodic Protection | Line | Gathering Pipe | Bare Steel | True |
Cathodic Protection | Line | Gathering Pipe | Cast Iron | True |
Cathodic Protection | Line | Gathering Pipe | Coated Steel | True |
Cathodic Protection | Line | Gathering Pipe | Composite | True |
Cathodic Protection | Line | Gathering Pipe | Ductile Iron | True |
Cathodic Protection | Line | Gathering Pipe | Plastic ABS | True |
Cathodic Protection | Line | Gathering Pipe | Plastic Other | True |
Cathodic Protection | Line | Gathering Pipe | Plastic PE | True |
Cathodic Protection | Line | Gathering Pipe | Plastic PVC | True |
Cathodic Protection | Line | Gathering Pipe | Reconditioned Cast Iron | True |
Cathodic Protection | Line | Gathering Pipe | Wrought Iron | True |
Cathodic Protection | Line | Station Pipe | Unknown | False |
Cathodic Protection | Line | Station Pipe | Bare Steel | False |
Cathodic Protection | Line | Station Pipe | Cast Iron | False |
Cathodic Protection | Line | Station Pipe | Coated Steel | False |
Cathodic Protection | Line | Station Pipe | Composite | False |
Cathodic Protection | Line | Station Pipe | Ductile Iron | False |
Cathodic Protection | Line | Station Pipe | Reconditioned Cast Iron | False |
Cathodic Protection | Line | Station Pipe | Wrought Iron | False |
Cathodic Protection | Line | Customer Pipe | Unknown | False |
Cathodic Protection | Line | Customer Pipe | Bare Steel | False |
Cathodic Protection | Line | Customer Pipe | Cast Iron | False |
Cathodic Protection | Line | Customer Pipe | Coated Steel | False |
Cathodic Protection | Line | Customer Pipe | Composite | False |
Cathodic Protection | Line | Customer Pipe | Ductile Iron | False |
Cathodic Protection | Line | Customer Pipe | Plastic ABS | False |
Cathodic Protection | Line | Customer Pipe | Plastic Other | False |
Cathodic Protection | Line | Customer Pipe | Plastic PE | False |
Cathodic Protection | Line | Customer Pipe | Plastic PVC | False |
Cathodic Protection | Line | Customer Pipe | Reconditioned Cast Iron | False |
Cathodic Protection | Line | Customer Pipe | Wrought Iron | False |
Cathodic Protection | Line | Riser Pipe | Unknown | False |
Cathodic Protection | Line | Riser Pipe | Bare Steel | False |
Cathodic Protection | Line | Riser Pipe | Cast Iron | False |
Cathodic Protection | Line | Riser Pipe | Coated Steel | False |
Cathodic Protection | Line | Riser Pipe | Composite | False |
Cathodic Protection | Line | Riser Pipe | Ductile Iron | False |
Cathodic Protection | Line | Riser Pipe | Reconditioned Cast Iron | False |
Cathodic Protection | Line | Riser Pipe | Wrought Iron | False |
Cathodic Protection | Line | Storage Pipe | Bare Steel | False |
Cathodic Protection | Line | Storage Pipe | Cast Iron | False |
Cathodic Protection | Line | Storage Pipe | Coated Steel | False |
Cathodic Protection | Line | Storage Pipe | Composite | False |
Cathodic Protection | Line | Storage Pipe | Copper | False |
Cathodic Protection | Line | Storage Pipe | Ductile Iron | False |
Cathodic Protection | Line | Storage Pipe | Plastic ABS | False |
Cathodic Protection | Line | Storage Pipe | Plastic Other | False |
Cathodic Protection | Line | Storage Pipe | Plastic PE | False |
Cathodic Protection | Line | Storage Pipe | Plastic PVC | False |
Cathodic Protection | Line | Storage Pipe | Reconditioned Cast Iron | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Unknown | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Bare Steel | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Cast Iron | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Coated Steel | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Ductile Iron | False |
Cathodic Protection | Line | Pressure Sensor Pipe | Wrought Iron | False |
Cathodic Protection | Line | Bonding Line | Unknown | False |
Cathodic Protection | Line | Bonding Line | Wire | False |
Cathodic Protection | Line | Bonding Line | Strap | False |
Cathodic Protection | Line | Test Lead Wire | Unknown | False |
Cathodic Protection | Line | Test Lead Wire | Aqua | False |
Cathodic Protection | Line | Test Lead Wire | Blue | False |
Cathodic Protection | Line | Test Lead Wire | Forest | False |
Cathodic Protection | Line | Test Lead Wire | Green | False |
Cathodic Protection | Line | Test Lead Wire | Lavender | False |
Cathodic Protection | Line | Test Lead Wire | Orange | False |
Cathodic Protection | Line | Test Lead Wire | Pink | False |
Cathodic Protection | Line | Test Lead Wire | Red | False |
Cathodic Protection | Line | Test Lead Wire | Yellow | False |
Cathodic Protection | Line | Test Lead Wire | Purple | False |
Cathodic Protection | Line | CP Cable | Unknown | False |
Cathodic Protection | Line | CP Cable | Rectifier Cable | False |
Cathodic Protection | Line | CP Cable | Decoupler Cable | False |
Cathodic Protection | Line | Linear Anode | Unknown | False |
Cathodic Protection | Line | Linear Anode | Horizontal Anode | False |
Cathodic Protection | Line | Linear Anode | Ribbon | False |
Cathodic Protection | Line | AC Mitigation Wire | Unknown | False |
Cathodic Protection | Line | AC Mitigation Wire | Mitigation Wire | False |
Cathodic Protection | Junction | Coupling | Unknown | |
Cathodic Protection | Junction | Coupling | Metal Coupling | |
Cathodic Protection | Junction | Coupling | Plastic Coupling | |
Cathodic Protection | Junction | Elbow | Unknown | |
Cathodic Protection | Junction | Elbow | Metal Elbow | |
Cathodic Protection | Junction | Elbow | Plastic Elbow | |
Cathodic Protection | Junction | End Cap | Unknown | |
Cathodic Protection | Junction | End Cap | Metal End Cap | |
Cathodic Protection | Junction | End Cap | Plastic End Cap | |
Cathodic Protection | Junction | Expansion Joint | Unknown | |
Cathodic Protection | Junction | Expansion Joint | Expansion Joint | |
Cathodic Protection | Junction | Flange | Unknown | |
Cathodic Protection | Junction | Flange | Metal Flange | |
Cathodic Protection | Junction | Reducer | Unknown | |
Cathodic Protection | Junction | Reducer | Metal Reducer | |
Cathodic Protection | Junction | Reducer | Plastic Reducer | |
Cathodic Protection | Junction | Tee | Unknown | |
Cathodic Protection | Junction | Tee | Metal 3-Way | |
Cathodic Protection | Junction | Tee | Metal 4-Way | |
Cathodic Protection | Junction | Tee | Plastic 3-Way | |
Cathodic Protection | Junction | Tee | Plastic 4-Way | |
Cathodic Protection | Junction | Transition | Unknown | |
Cathodic Protection | Junction | Transition | Transition | |
Cathodic Protection | Junction | Weld | Unknown | |
Cathodic Protection | Junction | Weld | Weld | |
Cathodic Protection | Junction | Screw | Unknown | |
Cathodic Protection | Junction | Screw | Screw | |
Cathodic Protection | Junction | Electro Stop | Unknown | |
Cathodic Protection | Junction | Electro Stop | Electro Stop | |
Cathodic Protection | Junction | Plastic Fusion | Unknown | |
Cathodic Protection | Junction | Plastic Fusion | Plastic Fusion | |
Cathodic Protection | Junction | Saddle | Unknown | |
Cathodic Protection | Junction | Saddle | Metal Saddle | |
Cathodic Protection | Junction | Saddle | Plastic Saddle | |
Cathodic Protection | Junction | Tank | Unknown | |
Cathodic Protection | Junction | Tank | Tank | |
Cathodic Protection | Junction | Line Heater | Unknown | |
Cathodic Protection | Junction | Line Heater | Line Heater | |
Cathodic Protection | Junction | Cooling System | Unknown | |
Cathodic Protection | Junction | Cooling System | Cooling System | |
Cathodic Protection | Junction | Odorizer | Unknown | |
Cathodic Protection | Junction | Odorizer | Absorption Bypass | |
Cathodic Protection | Junction | Odorizer | Injection Pump | |
Cathodic Protection | Junction | Odorizer | Pulse | |
Cathodic Protection | Junction | Odorizer | Rural Tap Odorizer | |
Cathodic Protection | Junction | Odorizer | Wick | |
Cathodic Protection | Junction | Coupon | Unknown | |
Cathodic Protection | Junction | Coupon | Coupon | |
Cathodic Protection | Junction | Dehydration Equipment | Unknown | |
Cathodic Protection | Junction | Dehydration Equipment | Glycol Dehydration | |
Cathodic Protection | Junction | Dehydration Equipment | Methanol Dehydration | |
Cathodic Protection | Junction | Dehydration Equipment | Solid Absorption | |
Cathodic Protection | Junction | Drip | Unknown | |
Cathodic Protection | Junction | Drip | Drip | |
Cathodic Protection | Junction | Connection Point | Unknown | |
Cathodic Protection | Junction | Connection Point | Connection Point | |
Cathodic Protection | Junction | Union | Unknown | |
Cathodic Protection | Junction | Union | Metal Union | |
Cathodic Protection | Junction | Plug | Unknown | |
Cathodic Protection | Junction | Plug | Test Plug | |
Cathodic Protection | Junction | Tap | Unknown | |
Cathodic Protection | Junction | Tap | Cold Tap | |
Cathodic Protection | Junction | Tap | Hot Tap | |
Cathodic Protection | Junction | Tap | Full Encirclement | |
Cathodic Protection | Junction | Pipe Bend | Unknown | |
Cathodic Protection | Junction | Pipe Bend | Hot Bend | |
Cathodic Protection | Junction | Pipe Bend | Cold Bend | |
Cathodic Protection | Junction | Pipe Bend | Miter Bend | |
Cathodic Protection | Junction | Pipe Bend | Field Bend | |
Cathodic Protection | Junction | Pipe Bend | Wrinkle Bend | |
Cathodic Protection | Junction | Pipe Bend | Factory Bend | |
Cathodic Protection | Junction | Wire Junction | Unknown | |
Cathodic Protection | Junction | Wire Junction | Bond Junction | |
Cathodic Protection | Junction | Wire Junction | Test Lead | |
Cathodic Protection | Junction | Insulation Junction | Unknown | |
Cathodic Protection | Junction | Insulation Junction | Flange Insert | |
System | Device | Lamp | Unknown | False |
System | Device | Lamp | Lamp | False |
System | Device | Excess Flow Valve | Unknown | False |
System | Device | Excess Flow Valve | Automatic Reset | False |
System | Device | Excess Flow Valve | Manual Reset | False |
System | Device | Excess Flow Valve | Breakaway Fitting | False |
System | Device | Meter | Unknown | False |
System | Device | Meter | Custody Transfer | True |
System | Device | Meter | Customer | False |
System | Device | Meter | Utility | False |
System | Device | Controllable Valve | Unknown | False |
System | Device | Controllable Valve | Bypass | False |
System | Device | Controllable Valve | Emergency | False |
System | Device | Controllable Valve | System | False |
System | Device | Controllable Valve | Meter | False |
System | Device | Flow Valve | Unknown | False |
System | Device | Flow Valve | Check | False |
System | Device | Flow Valve | Slam-shut | False |
System | Device | Relief Valve | Unknown | False |
System | Device | Relief Valve | Blow Off | False |
System | Device | Relief Valve | Flare | False |
System | Device | Relief Valve | Over Pressure Protection | False |
System | Device | Relief Valve | Vacuum Pressure Protection | False |
System | Device | Relief Valve | Over Pressure and Vacuum Pressure Protection | False |
System | Device | Strainer | Unknown | False |
System | Device | Strainer | Strainer | False |
System | Device | Pressure Monitoring Device | Unknown | False |
System | Device | Pressure Monitoring Device | Pressure Monitoring Device | False |
System | Device | Compressor | Unknown | False |
System | Device | Compressor | Electric Motor | False |
System | Device | Compressor | Reciprocating Engine | False |
System | Device | Compressor | Turbine | False |
System | Device | Wellhead Source Flange | Unknown | False |
System | Device | Wellhead Source Flange | Flange | True |
System | Device | Controllable Tee | Unknown | False |
System | Device | Controllable Tee | Controllable Tee | False |
System | Device | Line Stopper | Unknown | False |
System | Device | Line Stopper | Line Stopper | False |
System | Device | Pump | Unknown | False |
System | Device | Pump | Booster | False |
System | Device | Pump | Primary | False |
System | Device | Regulator | Unknown | False |
System | Device | Regulator | Regulator | False |
System | Device | Regulator | Customer Regulator | False |
System | Device | Scrubber | Unknown | False |
System | Device | Scrubber | Scrubber | False |
System | Device | Anode | Unknown | False |
System | Device | Anode | ICCP | False |
System | Device | Anode | Galvanic | False |
System | Device | Rectifier | Unknown | False |
System | Device | Rectifier | Rectifier | False |
System | Device | Test Point | Unknown | False |
System | Device | Test Point | Above Ground | False |
System | Device | Test Point | Buried | False |
System | Device | Test Point | On Post | False |
System | Device | Test Point | Pipeline Marker | False |
System | Device | Test Point | Service Line | False |
System | Device | Decoupler | Unknown | False |
System | Device | Decoupler | AC Decoupler | False |
System | Device | Decoupler | DC Decoupler | False |
System | Device | Grounding Point | Unknown | False |
System | Device | Grounding Point | Grounding Point | False |
System | Device | Service Station | Metered | False |
System | Device | Service Station | Metered and Regulated | False |
System | Line | Service Pipe | Unknown | False |
System | Line | Service Pipe | Bare Steel | False |
System | Line | Service Pipe | Cast Iron | False |
System | Line | Service Pipe | Coated Steel | False |
System | Line | Service Pipe | Composite | False |
System | Line | Service Pipe | Copper | False |
System | Line | Service Pipe | Ductile Iron | False |
System | Line | Service Pipe | Plastic ABS | False |
System | Line | Service Pipe | Plastic Other | False |
System | Line | Service Pipe | Plastic PE | False |
System | Line | Service Pipe | Plastic PVC | False |
System | Line | Service Pipe | Reconditioned Cast Iron | False |
System | Line | Service Pipe | Wrought Iron | False |
System | Line | Distribution Pipe | Unknown | False |
System | Line | Distribution Pipe | Bare Steel | True |
System | Line | Distribution Pipe | Cast Iron | True |
System | Line | Distribution Pipe | Coated Steel | True |
System | Line | Distribution Pipe | Composite | True |
System | Line | Distribution Pipe | Copper | True |
System | Line | Distribution Pipe | Ductile Iron | True |
System | Line | Distribution Pipe | Plastic ABS | True |
System | Line | Distribution Pipe | Plastic Other | True |
System | Line | Distribution Pipe | Plastic PE | True |
System | Line | Distribution Pipe | Plastic PVC | True |
System | Line | Distribution Pipe | Reconditioned Cast Iron | True |
System | Line | Distribution Pipe | Wrought Iron | True |
System | Line | Transmission Pipe | Unknown | False |
System | Line | Transmission Pipe | Bare Steel | True |
System | Line | Transmission Pipe | Cast Iron | True |
System | Line | Transmission Pipe | Coated Steel | True |
System | Line | Transmission Pipe | Composite | True |
System | Line | Transmission Pipe | Ductile Iron | True |
System | Line | Transmission Pipe | Reconditioned Cast Iron | True |
System | Line | Transmission Pipe | Wrought Iron | True |
System | Line | Gathering Pipe | Unknown | False |
System | Line | Gathering Pipe | Bare Steel | True |
System | Line | Gathering Pipe | Cast Iron | True |
System | Line | Gathering Pipe | Coated Steel | True |
System | Line | Gathering Pipe | Composite | True |
System | Line | Gathering Pipe | Ductile Iron | True |
System | Line | Gathering Pipe | Plastic ABS | False |
System | Line | Gathering Pipe | Plastic Other | True |
System | Line | Gathering Pipe | Plastic PE | True |
System | Line | Gathering Pipe | Plastic PVC | False |
System | Line | Gathering Pipe | Reconditioned Cast Iron | True |
System | Line | Gathering Pipe | Wrought Iron | True |
System | Line | Station Pipe | Unknown | False |
System | Line | Station Pipe | Bare Steel | False |
System | Line | Station Pipe | Cast Iron | False |
System | Line | Station Pipe | Coated Steel | False |
System | Line | Station Pipe | Composite | False |
System | Line | Station Pipe | Ductile Iron | False |
System | Line | Station Pipe | Reconditioned Cast Iron | False |
System | Line | Station Pipe | Wrought Iron | False |
System | Line | Customer Pipe | Unknown | False |
System | Line | Customer Pipe | Bare Steel | False |
System | Line | Customer Pipe | Cast Iron | False |
System | Line | Customer Pipe | Coated Steel | False |
System | Line | Customer Pipe | Composite | False |
System | Line | Customer Pipe | Ductile Iron | False |
System | Line | Customer Pipe | Plastic ABS | False |
System | Line | Customer Pipe | Plastic Other | False |
System | Line | Customer Pipe | Plastic PE | False |
System | Line | Customer Pipe | Plastic PVC | False |
System | Line | Customer Pipe | Reconditioned Cast Iron | False |
System | Line | Customer Pipe | Wrought Iron | False |
System | Line | Riser Pipe | Unknown | False |
System | Line | Riser Pipe | Bare Steel | False |
System | Line | Riser Pipe | Cast Iron | False |
System | Line | Riser Pipe | Coated Steel | False |
System | Line | Riser Pipe | Composite | False |
System | Line | Riser Pipe | Ductile Iron | False |
System | Line | Riser Pipe | Reconditioned Cast Iron | False |
System | Line | Riser Pipe | Wrought Iron | False |
System | Line | Storage Pipe | Unknown | False |
System | Line | Storage Pipe | Bare Steel | False |
System | Line | Storage Pipe | Cast Iron | False |
System | Line | Storage Pipe | Coated Steel | False |
System | Line | Storage Pipe | Composite | False |
System | Line | Storage Pipe | Copper | False |
System | Line | Storage Pipe | Ductile Iron | False |
System | Line | Storage Pipe | Plastic ABS | False |
System | Line | Storage Pipe | Plastic Other | False |
System | Line | Storage Pipe | Plastic PE | False |
System | Line | Storage Pipe | Plastic PVC | False |
System | Line | Storage Pipe | Reconditioned Cast Iron | False |
System | Line | Storage Pipe | Wrought Iron | False |
System | Line | Pressure Sensor Pipe | Unknown | False |
System | Line | Pressure Sensor Pipe | Bare Steel | False |
System | Line | Pressure Sensor Pipe | Cast Iron | False |
System | Line | Pressure Sensor Pipe | Coated Steel | False |
System | Line | Pressure Sensor Pipe | Ductile Iron | False |
System | Line | Pressure Sensor Pipe | Wrought Iron | False |
System | Line | Bonding Line | Unknown | False |
System | Line | Bonding Line | Wire | False |
System | Line | Bonding Line | Strap | False |
System | Line | Test Lead Wire | Unknown | False |
System | Line | Test Lead Wire | Aqua | False |
System | Line | Test Lead Wire | Blue | False |
System | Line | Test Lead Wire | Forest | False |
System | Line | Test Lead Wire | Green | False |
System | Line | Test Lead Wire | Lavender | False |
System | Line | Test Lead Wire | Orange | False |
System | Line | Test Lead Wire | Pink | False |
System | Line | Test Lead Wire | Red | False |
System | Line | Test Lead Wire | Yellow | False |
System | Line | Test Lead Wire | Purple | False |
System | Line | CP Cable | Unknown | False |
System | Line | CP Cable | Rectifier Cable | False |
System | Line | CP Cable | Decoupler Cable | False |
System | Line | Linear Anode | Unknown | False |
System | Line | Linear Anode | Horizontal Anode | False |
System | Line | Linear Anode | Ribbon | False |
System | Line | AC Mitigation Wire | Unknown | False |
System | Line | AC Mitigation Wire | Mitigation Wire | False |
System | Junction | Coupling | Unknown | |
System | Junction | Coupling | Metal Coupling | |
System | Junction | Coupling | Plastic Coupling | |
System | Junction | Elbow | Unknown | |
System | Junction | Elbow | Metal Elbow | |
System | Junction | Elbow | Plastic Elbow | |
System | Junction | End Cap | Unknown | |
System | Junction | End Cap | Metal End Cap | |
System | Junction | End Cap | Plastic End Cap | |
System | Junction | Expansion Joint | Unknown | |
System | Junction | Expansion Joint | Expansion Joint | |
System | Junction | Flange | Unknown | |
System | Junction | Flange | Metal Flange | |
System | Junction | Reducer | Unknown | |
System | Junction | Reducer | Metal Reducer | |
System | Junction | Reducer | Plastic Reducer | |
System | Junction | Tee | Unknown | |
System | Junction | Tee | Metal 3-Way | |
System | Junction | Tee | Metal 4-Way | |
System | Junction | Tee | Plastic 3-Way | |
System | Junction | Tee | Plastic 4-Way | |
System | Junction | Transition | Unknown | |
System | Junction | Transition | Transition | |
System | Junction | Weld | Unknown | |
System | Junction | Weld | Weld | |
System | Junction | Screw | Unknown | |
System | Junction | Screw | Screw | |
System | Junction | Electro Stop | Unknown | |
System | Junction | Electro Stop | Electro Stop | |
System | Junction | Plastic Fusion | Unknown | |
System | Junction | Plastic Fusion | Plastic Fusion | |
System | Junction | Saddle | Unknown | |
System | Junction | Saddle | Metal Saddle | |
System | Junction | Saddle | Plastic Saddle | |
System | Junction | Tank | Unknown | |
System | Junction | Tank | Tank | |
System | Junction | Line Heater | Unknown | |
System | Junction | Line Heater | Line Heater | |
System | Junction | Cooling System | Unknown | |
System | Junction | Cooling System | Cooling System | |
System | Junction | Odorizer | Unknown | |
System | Junction | Odorizer | Absorption Bypass | |
System | Junction | Odorizer | Injection Pump | |
System | Junction | Odorizer | Pulse | |
System | Junction | Odorizer | Rural Tap Odorizer | |
System | Junction | Odorizer | Wick | |
System | Junction | Coupon | Unknown | |
System | Junction | Coupon | Coupon | |
System | Junction | Dehydration Equipment | Unknown | |
System | Junction | Dehydration Equipment | Glycol Dehydration | |
System | Junction | Dehydration Equipment | Methanol Dehydration | |
System | Junction | Dehydration Equipment | Solid Absorption | |
System | Junction | Drip | Unknown | |
System | Junction | Drip | Drip | |
System | Junction | Connection Point | Unknown | |
System | Junction | Connection Point | Connection Point | |
System | Junction | Union | Unknown | |
System | Junction | Union | Metal Union | |
System | Junction | Plug | Unknown | |
System | Junction | Plug | Test Plug | |
System | Junction | Tap | Unknown | |
System | Junction | Tap | Cold Tap | |
System | Junction | Tap | Hot Tap | |
System | Junction | Tap | Full Encirclement | |
System | Junction | Pipe Bend | Unknown | |
System | Junction | Pipe Bend | Hot Bend | |
System | Junction | Pipe Bend | Cold Bend | |
System | Junction | Pipe Bend | Miter Bend | |
System | Junction | Pipe Bend | Field Bend | |
System | Junction | Pipe Bend | Wrinkle Bend | |
System | Junction | Pipe Bend | Factory Bend | |
System | Junction | Wire Junction | Unknown | |
System | Junction | Wire Junction | Bond Junction | |
System | Junction | Wire Junction | Test Lead | |
System | Junction | Insulation Junction | Unknown | |
System | Junction | Insulation Junction | Flange Insert | |
System | Junction | Olet | Weldolet | |
System | Junction | Olet | Threadolet | |
System | Junction | Olet | Sockolet | |
Pressure | Device | Lamp | Unknown | False |
Pressure | Device | Lamp | Lamp | False |
Pressure | Device | Excess Flow Valve | Unknown | False |
Pressure | Device | Excess Flow Valve | Automatic Reset | False |
Pressure | Device | Excess Flow Valve | Manual Reset | False |
Pressure | Device | Excess Flow Valve | Breakaway Fitting | False |
Pressure | Device | Meter | Unknown | False |
Pressure | Device | Meter | Custody Transfer | False |
Pressure | Device | Meter | Customer | False |
Pressure | Device | Meter | Utility | False |
Pressure | Device | Controllable Valve | Unknown | False |
Pressure | Device | Controllable Valve | Bypass | False |
Pressure | Device | Controllable Valve | Emergency | False |
Pressure | Device | Controllable Valve | System | False |
Pressure | Device | Controllable Valve | Meter | False |
Pressure | Device | Flow Valve | Unknown | False |
Pressure | Device | Flow Valve | Check | False |
Pressure | Device | Flow Valve | Slam-shut | False |
Pressure | Device | Relief Valve | Unknown | False |
Pressure | Device | Relief Valve | Blow Off | False |
Pressure | Device | Relief Valve | Flare | False |
Pressure | Device | Relief Valve | Over Pressure Protection | False |
Pressure | Device | Relief Valve | Vacuum Pressure Protection | False |
Pressure | Device | Relief Valve | Over Pressure and Vacuum Pressure Protection | False |
Pressure | Device | Strainer | Unknown | False |
Pressure | Device | Strainer | Strainer | False |
Pressure | Device | Pressure Monitoring Device | Unknown | False |
Pressure | Device | Pressure Monitoring Device | Pressure Monitoring Device | False |
Pressure | Device | Compressor | Unknown | False |
Pressure | Device | Compressor | Electric Motor | True |
Pressure | Device | Compressor | Reciprocating Engine | True |
Pressure | Device | Compressor | Turbine | True |
Pressure | Device | Wellhead Source Flange | Unknown | False |
Pressure | Device | Wellhead Source Flange | Flange | False |
Pressure | Device | Controllable Tee | Unknown | False |
Pressure | Device | Controllable Tee | Controllable Tee | False |
Pressure | Device | Line Stopper | Unknown | False |
Pressure | Device | Line Stopper | Line Stopper | False |
Pressure | Device | Pump | Unknown | False |
Pressure | Device | Pump | Booster | True |
Pressure | Device | Pump | Primary | True |
Pressure | Device | Regulator | Unknown | False |
Pressure | Device | Regulator | Regulator | True |
Pressure | Device | Regulator | Customer Regulator | False |
Pressure | Device | Scrubber | Unknown | False |
Pressure | Device | Scrubber | Scrubber | False |
Pressure | Device | Anode | Unknown | False |
Pressure | Device | Anode | ICCP | False |
Pressure | Device | Anode | Galvanic | False |
Pressure | Device | Rectifier | Unknown | False |
Pressure | Device | Rectifier | Rectifier | False |
Pressure | Device | Test Point | Unknown | False |
Pressure | Device | Test Point | Above Ground | False |
Pressure | Device | Test Point | Buried | False |
Pressure | Device | Test Point | On Post | False |
Pressure | Device | Test Point | Pipeline Marker | False |
Pressure | Device | Test Point | Service Line | False |
Pressure | Device | Decoupler | Unknown | False |
Pressure | Device | Decoupler | AC Decoupler | False |
Pressure | Device | Decoupler | DC Decoupler | False |
Pressure | Device | Grounding Point | Unknown | False |
Pressure | Device | Grounding Point | Grounding Point | False |
Pressure | Device | Service Station | Metered | False |
Pressure | Device | Service Station | Metered and Regulated | False |
Pressure | Line | Service Pipe | Unknown | False |
Pressure | Line | Service Pipe | Bare Steel | False |
Pressure | Line | Service Pipe | Cast Iron | False |
Pressure | Line | Service Pipe | Coated Steel | False |
Pressure | Line | Service Pipe | Composite | False |
Pressure | Line | Service Pipe | Copper | False |
Pressure | Line | Service Pipe | Ductile Iron | False |
Pressure | Line | Service Pipe | Plastic ABS | False |
Pressure | Line | Service Pipe | Plastic Other | False |
Pressure | Line | Service Pipe | Plastic PE | False |
Pressure | Line | Service Pipe | Plastic PVC | False |
Pressure | Line | Service Pipe | Reconditioned Cast Iron | False |
Pressure | Line | Service Pipe | Wrought Iron | False |
Pressure | Line | Distribution Pipe | Unknown | False |
Pressure | Line | Distribution Pipe | Bare Steel | True |
Pressure | Line | Distribution Pipe | Cast Iron | True |
Pressure | Line | Distribution Pipe | Coated Steel | True |
Pressure | Line | Distribution Pipe | Composite | True |
Pressure | Line | Distribution Pipe | Copper | True |
Pressure | Line | Distribution Pipe | Ductile Iron | True |
Pressure | Line | Distribution Pipe | Plastic ABS | True |
Pressure | Line | Distribution Pipe | Plastic Other | True |
Pressure | Line | Distribution Pipe | Plastic PE | True |
Pressure | Line | Distribution Pipe | Plastic PVC | True |
Pressure | Line | Distribution Pipe | Reconditioned Cast Iron | True |
Pressure | Line | Distribution Pipe | Wrought Iron | True |
Pressure | Line | Transmission Pipe | Unknown | False |
Pressure | Line | Transmission Pipe | Bare Steel | True |
Pressure | Line | Transmission Pipe | Cast Iron | True |
Pressure | Line | Transmission Pipe | Coated Steel | True |
Pressure | Line | Transmission Pipe | Composite | True |
Pressure | Line | Transmission Pipe | Ductile Iron | True |
Pressure | Line | Transmission Pipe | Reconditioned Cast Iron | True |
Pressure | Line | Transmission Pipe | Wrought Iron | True |
Pressure | Line | Gathering Pipe | Unknown | False |
Pressure | Line | Gathering Pipe | Bare Steel | True |
Pressure | Line | Gathering Pipe | Cast Iron | True |
Pressure | Line | Gathering Pipe | Coated Steel | True |
Pressure | Line | Gathering Pipe | Composite | True |
Pressure | Line | Gathering Pipe | Ductile Iron | True |
Pressure | Line | Gathering Pipe | Plastic ABS | False |
Pressure | Line | Gathering Pipe | Plastic Other | True |
Pressure | Line | Gathering Pipe | Plastic PE | True |
Pressure | Line | Gathering Pipe | Plastic PVC | False |
Pressure | Line | Gathering Pipe | Reconditioned Cast Iron | True |
Pressure | Line | Gathering Pipe | Wrought Iron | True |
Pressure | Line | Station Pipe | Unknown | False |
Pressure | Line | Station Pipe | Bare Steel | False |
Pressure | Line | Station Pipe | Cast Iron | False |
Pressure | Line | Station Pipe | Coated Steel | False |
Pressure | Line | Station Pipe | Composite | False |
Pressure | Line | Station Pipe | Ductile Iron | False |
Pressure | Line | Station Pipe | Reconditioned Cast Iron | False |
Pressure | Line | Station Pipe | Wrought Iron | False |
Pressure | Line | Customer Pipe | Unknown | False |
Pressure | Line | Customer Pipe | Bare Steel | False |
Pressure | Line | Customer Pipe | Cast Iron | False |
Pressure | Line | Customer Pipe | Coated Steel | False |
Pressure | Line | Customer Pipe | Composite | False |
Pressure | Line | Customer Pipe | Ductile Iron | False |
Pressure | Line | Customer Pipe | Plastic ABS | False |
Pressure | Line | Customer Pipe | Plastic Other | False |
Pressure | Line | Customer Pipe | Plastic PE | False |
Pressure | Line | Customer Pipe | Plastic PVC | False |
Pressure | Line | Customer Pipe | Reconditioned Cast Iron | False |
Pressure | Line | Customer Pipe | Wrought Iron | False |
Pressure | Line | Riser Pipe | Unknown | False |
Pressure | Line | Riser Pipe | Bare Steel | False |
Pressure | Line | Riser Pipe | Cast Iron | False |
Pressure | Line | Riser Pipe | Coated Steel | False |
Pressure | Line | Riser Pipe | Composite | False |
Pressure | Line | Riser Pipe | Ductile Iron | False |
Pressure | Line | Riser Pipe | Reconditioned Cast Iron | False |
Pressure | Line | Riser Pipe | Wrought Iron | False |
Pressure | Line | Storage Pipe | Unknown | False |
Pressure | Line | Storage Pipe | Bare Steel | False |
Pressure | Line | Storage Pipe | Cast Iron | False |
Pressure | Line | Storage Pipe | Coated Steel | False |
Pressure | Line | Storage Pipe | Composite | False |
Pressure | Line | Storage Pipe | Copper | False |
Pressure | Line | Storage Pipe | Ductile Iron | False |
Pressure | Line | Storage Pipe | Plastic ABS | False |
Pressure | Line | Storage Pipe | Plastic Other | False |
Pressure | Line | Storage Pipe | Plastic PE | False |
Pressure | Line | Storage Pipe | Plastic PVC | False |
Pressure | Line | Storage Pipe | Reconditioned Cast Iron | False |
Pressure | Line | Storage Pipe | Wrought Iron | False |
Pressure | Line | Pressure Sensor Pipe | Unknown | False |
Pressure | Line | Pressure Sensor Pipe | Bare Steel | False |
Pressure | Line | Pressure Sensor Pipe | Cast Iron | False |
Pressure | Line | Pressure Sensor Pipe | Coated Steel | False |
Pressure | Line | Pressure Sensor Pipe | Ductile Iron | False |
Pressure | Line | Pressure Sensor Pipe | Wrought Iron | False |
Pressure | Line | Bonding Line | Unknown | False |
Pressure | Line | Bonding Line | Wire | False |
Pressure | Line | Bonding Line | Strap | False |
Pressure | Line | Test Lead Wire | Unknown | False |
Pressure | Line | Test Lead Wire | Aqua | False |
Pressure | Line | Test Lead Wire | Blue | False |
Pressure | Line | Test Lead Wire | Forest | False |
Pressure | Line | Test Lead Wire | Green | False |
Pressure | Line | Test Lead Wire | Lavender | False |
Pressure | Line | Test Lead Wire | Orange | False |
Pressure | Line | Test Lead Wire | Pink | False |
Pressure | Line | Test Lead Wire | Red | False |
Pressure | Line | Test Lead Wire | Yellow | False |
Pressure | Line | Test Lead Wire | Purple | False |
Pressure | Line | CP Cable | Unknown | False |
Pressure | Line | CP Cable | Rectifier Cable | False |
Pressure | Line | CP Cable | Decoupler Cable | False |
Pressure | Line | Linear Anode | Unknown | False |
Pressure | Line | Linear Anode | Horizontal Anode | False |
Pressure | Line | Linear Anode | Ribbon | False |
Pressure | Line | AC Mitigation Wire | Unknown | False |
Pressure | Line | AC Mitigation Wire | Mitigation Wire | False |
Pressure | Junction | Coupling | Unknown | |
Pressure | Junction | Coupling | Metal Coupling | |
Pressure | Junction | Coupling | Plastic Coupling | |
Pressure | Junction | Elbow | Unknown | |
Pressure | Junction | Elbow | Metal Elbow | |
Pressure | Junction | Elbow | Plastic Elbow | |
Pressure | Junction | End Cap | Unknown | |
Pressure | Junction | End Cap | Metal End Cap | |
Pressure | Junction | End Cap | Plastic End Cap | |
Pressure | Junction | Expansion Joint | Unknown | |
Pressure | Junction | Expansion Joint | Expansion Joint | |
Pressure | Junction | Flange | Unknown | |
Pressure | Junction | Flange | Metal Flange | |
Pressure | Junction | Reducer | Unknown | |
Pressure | Junction | Reducer | Metal Reducer | |
Pressure | Junction | Reducer | Plastic Reducer | |
Pressure | Junction | Tee | Unknown | |
Pressure | Junction | Tee | Metal 3-Way | |
Pressure | Junction | Tee | Metal 4-Way | |
Pressure | Junction | Tee | Plastic 3-Way | |
Pressure | Junction | Tee | Plastic 4-Way | |
Pressure | Junction | Transition | Unknown | |
Pressure | Junction | Transition | Transition | |
Pressure | Junction | Weld | Unknown | |
Pressure | Junction | Weld | Weld | |
Pressure | Junction | Screw | Unknown | |
Pressure | Junction | Screw | Screw | |
Pressure | Junction | Electro Stop | Unknown | |
Pressure | Junction | Electro Stop | Electro Stop | |
Pressure | Junction | Plastic Fusion | Unknown | |
Pressure | Junction | Plastic Fusion | Plastic Fusion | |
Pressure | Junction | Saddle | Unknown | |
Pressure | Junction | Saddle | Metal Saddle | |
Pressure | Junction | Saddle | Plastic Saddle | |
Pressure | Junction | Tank | Unknown | |
Pressure | Junction | Tank | Tank | |
Pressure | Junction | Line Heater | Unknown | |
Pressure | Junction | Line Heater | Line Heater | |
Pressure | Junction | Cooling System | Unknown | |
Pressure | Junction | Cooling System | Cooling System | |
Pressure | Junction | Odorizer | Unknown | |
Pressure | Junction | Odorizer | Absorption Bypass | |
Pressure | Junction | Odorizer | Injection Pump | |
Pressure | Junction | Odorizer | Pulse | |
Pressure | Junction | Odorizer | Rural Tap Odorizer | |
Pressure | Junction | Odorizer | Wick | |
Pressure | Junction | Coupon | Unknown | |
Pressure | Junction | Coupon | Coupon | |
Pressure | Junction | Dehydration Equipment | Unknown | |
Pressure | Junction | Dehydration Equipment | Glycol Dehydration | |
Pressure | Junction | Dehydration Equipment | Methanol Dehydration | |
Pressure | Junction | Dehydration Equipment | Solid Absorption | |
Pressure | Junction | Drip | Unknown | |
Pressure | Junction | Drip | Drip | |
Pressure | Junction | Connection Point | Unknown | |
Pressure | Junction | Connection Point | Connection Point | |
Pressure | Junction | Union | Unknown | |
Pressure | Junction | Union | Metal Union | |
Pressure | Junction | Plug | Unknown | |
Pressure | Junction | Plug | Test Plug | |
Pressure | Junction | Tap | Unknown | |
Pressure | Junction | Tap | Cold Tap | |
Pressure | Junction | Tap | Hot Tap | |
Pressure | Junction | Tap | Full Encirclement | |
Pressure | Junction | Pipe Bend | Unknown | |
Pressure | Junction | Pipe Bend | Hot Bend | |
Pressure | Junction | Pipe Bend | Cold Bend | |
Pressure | Junction | Pipe Bend | Miter Bend | |
Pressure | Junction | Pipe Bend | Field Bend | |
Pressure | Junction | Pipe Bend | Wrinkle Bend | |
Pressure | Junction | Pipe Bend | Factory Bend | |
Pressure | Junction | Wire Junction | Unknown | |
Pressure | Junction | Wire Junction | Bond Junction | |
Pressure | Junction | Wire Junction | Test Lead | |
Pressure | Junction | Insulation Junction | Unknown | |
Pressure | Junction | Insulation Junction | Flange Insert | |
Pressure | Junction | Olet | Weldolet | |
Pressure | Junction | Olet | Threadolet | |
Pressure | Junction | Olet | Sockolet | |
Isolation | Device | Lamp | Unknown | False |
Isolation | Device | Lamp | Lamp | False |
Isolation | Device | Excess Flow Valve | Unknown | False |
Isolation | Device | Excess Flow Valve | Automatic Reset | False |
Isolation | Device | Excess Flow Valve | Manual Reset | False |
Isolation | Device | Excess Flow Valve | Breakaway Fitting | False |
Isolation | Device | Meter | Unknown | False |
Isolation | Device | Meter | Custody Transfer | False |
Isolation | Device | Meter | Customer | False |
Isolation | Device | Meter | Utility | False |
Isolation | Device | Controllable Valve | Unknown | False |
Isolation | Device | Controllable Valve | Bypass | False |
Isolation | Device | Controllable Valve | Emergency | True |
Isolation | Device | Controllable Valve | System | False |
Isolation | Device | Controllable Valve | Meter | False |
Isolation | Device | Flow Valve | Unknown | False |
Isolation | Device | Flow Valve | Check | False |
Isolation | Device | Flow Valve | Slam-shut | False |
Isolation | Device | Relief Valve | Unknown | False |
Isolation | Device | Relief Valve | Blow Off | False |
Isolation | Device | Relief Valve | Flare | False |
Isolation | Device | Relief Valve | Over Pressure Protection | False |
Isolation | Device | Relief Valve | Vacuum Pressure Protection | False |
Isolation | Device | Relief Valve | Over Pressure and Vacuum Pressure Protection | False |
Isolation | Device | Strainer | Unknown | False |
Isolation | Device | Strainer | Strainer | False |
Isolation | Device | Pressure Monitoring Device | Unknown | False |
Isolation | Device | Pressure Monitoring Device | Pressure Monitoring Device | False |
Isolation | Device | Compressor | Unknown | False |
Isolation | Device | Compressor | Electric Motor | False |
Isolation | Device | Compressor | Reciprocating Engine | False |
Isolation | Device | Compressor | Turbine | False |
Isolation | Device | Wellhead Source Flange | Unknown | False |
Isolation | Device | Wellhead Source Flange | Flange | False |
Isolation | Device | Controllable Tee | Unknown | False |
Isolation | Device | Controllable Tee | Controllable Tee | False |
Isolation | Device | Line Stopper | Unknown | False |
Isolation | Device | Line Stopper | Line Stopper | False |
Isolation | Device | Pump | Unknown | False |
Isolation | Device | Pump | Booster | False |
Isolation | Device | Pump | Primary | False |
Isolation | Device | Regulator | Unknown | False |
Isolation | Device | Regulator | Regulator | False |
Isolation | Device | Regulator | Customer Regulator | False |
Isolation | Device | Scrubber | Unknown | False |
Isolation | Device | Scrubber | Scrubber | False |
Isolation | Device | Anode | Unknown | False |
Isolation | Device | Anode | ICCP | False |
Isolation | Device | Anode | Galvanic | False |
Isolation | Device | Rectifier | Unknown | False |
Isolation | Device | Rectifier | Rectifier | False |
Isolation | Device | Test Point | Unknown | False |
Isolation | Device | Test Point | Above Ground | False |
Isolation | Device | Test Point | Buried | False |
Isolation | Device | Test Point | On Post | False |
Isolation | Device | Test Point | Pipeline Marker | False |
Isolation | Device | Test Point | Service Line | False |
Isolation | Device | Decoupler | Unknown | False |
Isolation | Device | Decoupler | AC Decoupler | False |
Isolation | Device | Decoupler | DC Decoupler | False |
Isolation | Device | Grounding Point | Unknown | False |
Isolation | Device | Grounding Point | Grounding Point | False |
Isolation | Device | Service Station | Metered | False |
Isolation | Device | Service Station | Metered and Regulated | False |
Isolation | Line | Service Pipe | Unknown | False |
Isolation | Line | Service Pipe | Bare Steel | False |
Isolation | Line | Service Pipe | Cast Iron | False |
Isolation | Line | Service Pipe | Coated Steel | False |
Isolation | Line | Service Pipe | Composite | False |
Isolation | Line | Service Pipe | Copper | False |
Isolation | Line | Service Pipe | Ductile Iron | False |
Isolation | Line | Service Pipe | Plastic ABS | False |
Isolation | Line | Service Pipe | Plastic Other | False |
Isolation | Line | Service Pipe | Plastic PE | False |
Isolation | Line | Service Pipe | Plastic PVC | False |
Isolation | Line | Service Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Service Pipe | Wrought Iron | False |
Isolation | Line | Distribution Pipe | Unknown | False |
Isolation | Line | Distribution Pipe | Bare Steel | True |
Isolation | Line | Distribution Pipe | Cast Iron | True |
Isolation | Line | Distribution Pipe | Coated Steel | True |
Isolation | Line | Distribution Pipe | Composite | True |
Isolation | Line | Distribution Pipe | Copper | True |
Isolation | Line | Distribution Pipe | Ductile Iron | True |
Isolation | Line | Distribution Pipe | Plastic ABS | True |
Isolation | Line | Distribution Pipe | Plastic Other | True |
Isolation | Line | Distribution Pipe | Plastic PE | True |
Isolation | Line | Distribution Pipe | Plastic PVC | True |
Isolation | Line | Distribution Pipe | Reconditioned Cast Iron | True |
Isolation | Line | Distribution Pipe | Wrought Iron | True |
Isolation | Line | Transmission Pipe | Unknown | False |
Isolation | Line | Transmission Pipe | Bare Steel | False |
Isolation | Line | Transmission Pipe | Cast Iron | False |
Isolation | Line | Transmission Pipe | Coated Steel | False |
Isolation | Line | Transmission Pipe | Composite | False |
Isolation | Line | Transmission Pipe | Ductile Iron | False |
Isolation | Line | Transmission Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Transmission Pipe | Wrought Iron | False |
Isolation | Line | Gathering Pipe | Unknown | False |
Isolation | Line | Gathering Pipe | Bare Steel | False |
Isolation | Line | Gathering Pipe | Cast Iron | False |
Isolation | Line | Gathering Pipe | Coated Steel | False |
Isolation | Line | Gathering Pipe | Composite | False |
Isolation | Line | Gathering Pipe | Ductile Iron | False |
Isolation | Line | Gathering Pipe | Plastic ABS | False |
Isolation | Line | Gathering Pipe | Plastic Other | False |
Isolation | Line | Gathering Pipe | Plastic PE | False |
Isolation | Line | Gathering Pipe | Plastic PVC | False |
Isolation | Line | Gathering Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Gathering Pipe | Wrought Iron | False |
Isolation | Line | Station Pipe | Unknown | False |
Isolation | Line | Station Pipe | Bare Steel | False |
Isolation | Line | Station Pipe | Cast Iron | False |
Isolation | Line | Station Pipe | Coated Steel | False |
Isolation | Line | Station Pipe | Composite | False |
Isolation | Line | Station Pipe | Ductile Iron | False |
Isolation | Line | Station Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Station Pipe | Wrought Iron | False |
Isolation | Line | Customer Pipe | Unknown | False |
Isolation | Line | Customer Pipe | Bare Steel | False |
Isolation | Line | Customer Pipe | Cast Iron | False |
Isolation | Line | Customer Pipe | Coated Steel | False |
Isolation | Line | Customer Pipe | Composite | False |
Isolation | Line | Customer Pipe | Ductile Iron | False |
Isolation | Line | Customer Pipe | Plastic ABS | False |
Isolation | Line | Customer Pipe | Plastic Other | False |
Isolation | Line | Customer Pipe | Plastic PE | False |
Isolation | Line | Customer Pipe | Plastic PVC | False |
Isolation | Line | Customer Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Customer Pipe | Wrought Iron | False |
Isolation | Line | Riser Pipe | Unknown | False |
Isolation | Line | Riser Pipe | Bare Steel | False |
Isolation | Line | Riser Pipe | Cast Iron | False |
Isolation | Line | Riser Pipe | Coated Steel | False |
Isolation | Line | Riser Pipe | Composite | False |
Isolation | Line | Riser Pipe | Ductile Iron | False |
Isolation | Line | Riser Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Riser Pipe | Wrought Iron | False |
Isolation | Line | Storage Pipe | Unknown | False |
Isolation | Line | Storage Pipe | Bare Steel | False |
Isolation | Line | Storage Pipe | Cast Iron | False |
Isolation | Line | Storage Pipe | Coated Steel | False |
Isolation | Line | Storage Pipe | Composite | False |
Isolation | Line | Storage Pipe | Copper | False |
Isolation | Line | Storage Pipe | Ductile Iron | False |
Isolation | Line | Storage Pipe | Plastic ABS | False |
Isolation | Line | Storage Pipe | Plastic Other | False |
Isolation | Line | Storage Pipe | Plastic PE | False |
Isolation | Line | Storage Pipe | Plastic PVC | False |
Isolation | Line | Storage Pipe | Reconditioned Cast Iron | False |
Isolation | Line | Storage Pipe | Wrought Iron | False |
Isolation | Line | Pressure Sensor Pipe | Unknown | False |
Isolation | Line | Pressure Sensor Pipe | Bare Steel | False |
Isolation | Line | Pressure Sensor Pipe | Cast Iron | False |
Isolation | Line | Pressure Sensor Pipe | Coated Steel | False |
Isolation | Line | Pressure Sensor Pipe | Ductile Iron | False |
Isolation | Line | Pressure Sensor Pipe | Wrought Iron | False |
Isolation | Line | Bonding Line | Unknown | False |
Isolation | Line | Bonding Line | Wire | False |
Isolation | Line | Bonding Line | Strap | False |
Isolation | Line | Test Lead Wire | Unknown | False |
Isolation | Line | Test Lead Wire | Aqua | False |
Isolation | Line | Test Lead Wire | Blue | False |
Isolation | Line | Test Lead Wire | Forest | False |
Isolation | Line | Test Lead Wire | Green | False |
Isolation | Line | Test Lead Wire | Lavender | False |
Isolation | Line | Test Lead Wire | Orange | False |
Isolation | Line | Test Lead Wire | Pink | False |
Isolation | Line | Test Lead Wire | Red | False |
Isolation | Line | Test Lead Wire | Yellow | False |
Isolation | Line | Test Lead Wire | Purple | False |
Isolation | Line | CP Cable | Unknown | False |
Isolation | Line | CP Cable | Rectifier Cable | False |
Isolation | Line | CP Cable | Decoupler Cable | False |
Isolation | Line | Linear Anode | Unknown | False |
Isolation | Line | Linear Anode | Horizontal Anode | False |
Isolation | Line | Linear Anode | Ribbon | False |
Isolation | Line | AC Mitigation Wire | Unknown | False |
Isolation | Line | AC Mitigation Wire | Mitigation Wire | False |
Isolation | Junction | Coupling | Unknown | |
Isolation | Junction | Coupling | Metal Coupling | |
Isolation | Junction | Coupling | Plastic Coupling | |
Isolation | Junction | Elbow | Unknown | |
Isolation | Junction | Elbow | Metal Elbow | |
Isolation | Junction | Elbow | Plastic Elbow | |
Isolation | Junction | End Cap | Unknown | |
Isolation | Junction | End Cap | Metal End Cap | |
Isolation | Junction | End Cap | Plastic End Cap | |
Isolation | Junction | Expansion Joint | Unknown | |
Isolation | Junction | Expansion Joint | Expansion Joint | |
Isolation | Junction | Flange | Unknown | |
Isolation | Junction | Flange | Metal Flange | |
Isolation | Junction | Reducer | Unknown | |
Isolation | Junction | Reducer | Metal Reducer | |
Isolation | Junction | Reducer | Plastic Reducer | |
Isolation | Junction | Tee | Unknown | |
Isolation | Junction | Tee | Metal 3-Way | |
Isolation | Junction | Tee | Metal 4-Way | |
Isolation | Junction | Tee | Plastic 3-Way | |
Isolation | Junction | Tee | Plastic 4-Way | |
Isolation | Junction | Transition | Unknown | |
Isolation | Junction | Transition | Transition | |
Isolation | Junction | Weld | Unknown | |
Isolation | Junction | Weld | Weld | |
Isolation | Junction | Screw | Unknown | |
Isolation | Junction | Screw | Screw | |
Isolation | Junction | Electro Stop | Unknown | |
Isolation | Junction | Electro Stop | Electro Stop | |
Isolation | Junction | Plastic Fusion | Unknown | |
Isolation | Junction | Plastic Fusion | Plastic Fusion | |
Isolation | Junction | Saddle | Unknown | |
Isolation | Junction | Saddle | Metal Saddle | |
Isolation | Junction | Saddle | Plastic Saddle | |
Isolation | Junction | Tank | Unknown | |
Isolation | Junction | Tank | Tank | |
Isolation | Junction | Line Heater | Unknown | |
Isolation | Junction | Line Heater | Line Heater | |
Isolation | Junction | Cooling System | Unknown | |
Isolation | Junction | Cooling System | Cooling System | |
Isolation | Junction | Odorizer | Unknown | |
Isolation | Junction | Odorizer | Absorption Bypass | |
Isolation | Junction | Odorizer | Injection Pump | |
Isolation | Junction | Odorizer | Pulse | |
Isolation | Junction | Odorizer | Rural Tap Odorizer | |
Isolation | Junction | Odorizer | Wick | |
Isolation | Junction | Coupon | Unknown | |
Isolation | Junction | Coupon | Coupon | |
Isolation | Junction | Dehydration Equipment | Unknown | |
Isolation | Junction | Dehydration Equipment | Glycol Dehydration | |
Isolation | Junction | Dehydration Equipment | Methanol Dehydration | |
Isolation | Junction | Dehydration Equipment | Solid Absorption | |
Isolation | Junction | Drip | Unknown | |
Isolation | Junction | Drip | Drip | |
Isolation | Junction | Connection Point | Unknown | |
Isolation | Junction | Connection Point | Connection Point | |
Isolation | Junction | Union | Unknown | |
Isolation | Junction | Union | Metal Union | |
Isolation | Junction | Plug | Unknown | |
Isolation | Junction | Plug | Test Plug | |
Isolation | Junction | Tap | Unknown | |
Isolation | Junction | Tap | Cold Tap | |
Isolation | Junction | Tap | Hot Tap | |
Isolation | Junction | Tap | Full Encirclement | |
Isolation | Junction | Pipe Bend | Unknown | |
Isolation | Junction | Pipe Bend | Hot Bend | |
Isolation | Junction | Pipe Bend | Cold Bend | |
Isolation | Junction | Pipe Bend | Miter Bend | |
Isolation | Junction | Pipe Bend | Field Bend | |
Isolation | Junction | Pipe Bend | Factory Bend | |
Isolation | Junction | Wire Junction | Unknown | |
Isolation | Junction | Wire Junction | Bond Junction | |
Isolation | Junction | Wire Junction | Test Lead | |
Isolation | Junction | Insulation Junction | Unknown | |
Isolation | Junction | Insulation Junction | Flange Insert | |
Isolation | Junction | Olet | Weldolet | |
Isolation | Junction | Olet | Threadolet | |
Isolation | Junction | Olet | Sockolet |
Tier Name | Include Containers | Include Content | Include Structures | Include Barriers | Validate Locatability | Traversability Scope |
---|---|---|---|---|---|---|
Cathodic Protection | False | False | False | False | False | junctionsAndEdges |
System | False | False | False | True | False | junctionsAndEdges |
Pressure | False | False | False | True | False | junctionsAndEdges |
Isolation | False | False | False | True | False | junctionsAndEdges |
Tier Name | Function | Network Attribute | Summary Field | Network Attribute / Category | Operator | Value | Combine Using Or |
---|---|---|---|---|---|---|---|
Cathodic Protection | Add | Measured Length | totalmeasurelength | ||||
Cathodic Protection | Add | P:Pipe Surface Area | totalsurfacearea | Category | Equal | MetalPipe | False |
Cathodic Protection | Add | Shape length | totallength | Category | Equal | MetalPipe | False |
Cathodic Protection | Count | Asset group | countanodes | Category | Equal | Anode | False |
Cathodic Protection | Count | Asset group | countrectifiers | Category | Equal | Rectifier | False |
Cathodic Protection | Count | Asset group | counttestpoint | Category | Equal | TestPoint | False |
System | Add | Measured Length | totalmeasurelength | ||||
System | Add | P:Pipe Surface Area | totalsurfacearea | ||||
System | Add | P:Pipe Volume | totalpipevolume | ||||
System | Add | Shape length | totallength | ||||
System | Count | Asset group | numbermeters | Category | Equal | Meter | False |
System | Min | P:MAOP Design | maopdesign | ||||
System | Min | P:MAOP Record | maoprecord | ||||
System | Min | P:MAOP Test | maoptest | ||||
Pressure | Add | Measured Length | totalmeasurelength | ||||
Pressure | Add | P:Pipe Surface Area | totalsurfacearea | ||||
Pressure | Add | P:Pipe Volume | totalpipevolume | ||||
Pressure | Add | Shape length | totallength | ||||
Pressure | Count | Asset group | numbermeters | Category | Equal | Meter | False |
Pressure | Count | Asset group | numbervalves | Category | Equal | Valve | False |
Pressure | Min | P:MAOP Design | maopdesign | ||||
Pressure | Min | P:MAOP Record | maoprecord | ||||
Pressure | Min | P:MAOP Test | maoptest | ||||
Isolation | Add | Measured Length | totalmeasurelength | ||||
Isolation | Add | P:Pipe Surface Area | totalsurfacearea | ||||
Isolation | Add | P:Pipe Volume | totalpipevolume | ||||
Isolation | Add | Shape length | totallength | ||||
Isolation | Count | Asset group | numbermeters | Category | Equal | Meter | False |
Isolation | Count | Asset group | numbervalves | Category | Equal | Valve | False |
Isolation | Min | P:MAOP Design | maopdesign | ||||
Isolation | Min | P:MAOP Record | maoprecord | ||||
Isolation | Min | P:MAOP Test | maoptest |
Tier Name | Network Attribute / Category | Operator | Value | Combine Using Or |
---|---|---|---|---|
Cathodic Protection | Cathodic Protection Traceability | Equal | 2 | False |
System | P:Device Status | Equal | 0 | True |
System | Category | Equal | CP Only | True |
System | Lifecycle Status | Does Not Include Any | 24 | False |
Pressure | P:Device Status | Equal | 0 | True |
Pressure | Lifecycle Status | Does Not Include Any | 24 | True |
Pressure | Category | Equal | CP Only | False |
Isolation | P:Device Status | Equal | 0 | True |
Isolation | Lifecycle Status | Does Not Include Any | 24 | True |
Isolation | Category | Equal | CP Only | False |
Domain Network Name | Source Name | Table | Usage Type | Source ID | # of Asset Groups | # of Asset Types |
---|---|---|---|---|---|---|
Structure | StructureJunction | main.StructureJunction | Structure Junction | 4 | 10 | 33 |
Structure | StructureBoundary | main.StructureBoundary | Structure Boundary | 6 | 5 | 13 |
Structure | StructureJunctionObject | main.StructureJunctionObject | Structure Junction Object | 7 | 1 | 1 |
Structure | StructureLine | main.StructureLine | Structure Line | 5 | 2 | 3 |
Structure | StructureEdgeObject | main.StructureEdgeObject | Structure Edge Object | 8 | 1 | 1 |
Pipeline | PipelineDevice | main.PipelineDevice | Device | 9 | 22 | 66 |
Pipeline | PipelineAssembly | main.PipelineAssembly | Assembly | 11 | 13 | 30 |
Pipeline | PipelineJunction | main.PipelineJunction | Junction | 12 | 29 | 81 |
Pipeline | PipelineJunctionObject | main.PipelineJunctionObject | Junction Object | 14 | 1 | 1 |
Pipeline | PipelineLine | main.PipelineLine | Line | 10 | 15 | 116 |
Pipeline | PipelineSubnetLine | main.PipelineSubnetLine | Subnet Line | 13 | 5 | 0 |
Pipeline | PipelineEdgeObject | main.PipelineEdgeObject | Edge Object | 15 | 1 | 1 |
Source Name | Asset Group Name | Asset Group Code | # of Asset Types | Creation Time |
---|---|---|---|---|
StructureJunction | Unknown | 0 | 1 | 2024-04-26 11:12:45 |
StructureJunction | Pipe Muffler | 1 | 2 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Anchor | 2 | 2 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Support | 3 | 3 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Hanger | 4 | 4 | 2024-04-26 11:14:28 |
StructureJunction | Pipe End Connection | 5 | 4 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Vault | 6 | 2 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Box | 7 | 6 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Sleeve | 8 | 3 | 2024-04-26 11:14:28 |
StructureJunction | Pipe Access Point | 10 | 6 | 2024-04-26 11:14:28 |
StructureBoundary | Unknown | 0 | 1 | 2024-04-26 11:12:45 |
StructureBoundary | Pipe Station | 1 | 6 | 2024-04-26 11:14:33 |
StructureBoundary | Pipe Vault | 2 | 2 | 2024-04-26 11:14:33 |
StructureBoundary | Pipe Processing Facility | 3 | 2 | 2024-04-26 11:14:33 |
StructureBoundary | Cathodic | 4 | 2 | 2024-04-26 11:14:33 |
StructureJunctionObject | Unknown | 0 | 1 | 2024-04-26 11:12:45 |
StructureLine | Unknown | 0 | 1 | 2024-04-26 11:12:45 |
StructureLine | Pipe Casing | 1 | 2 | 2024-04-26 11:14:37 |
StructureEdgeObject | Unknown | 0 | 1 | 2024-04-26 11:12:45 |
PipelineDevice | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
PipelineDevice | Excess Flow Valve | 1 | 4 | 2024-04-26 11:14:53 |
PipelineDevice | Meter | 2 | 4 | 2024-04-26 11:14:53 |
PipelineDevice | Controllable Valve | 3 | 5 | 2024-04-26 11:14:53 |
PipelineDevice | Flow Valve | 4 | 3 | 2024-04-26 11:14:53 |
PipelineDevice | Relief Valve | 5 | 6 | 2024-04-26 11:14:53 |
PipelineDevice | Strainer | 6 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Pressure Monitoring Device | 8 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Lamp | 9 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Compressor | 10 | 4 | 2024-04-26 11:14:53 |
PipelineDevice | Wellhead Source Flange | 11 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Controllable Tee | 12 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Line Stopper | 13 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Pump | 18 | 3 | 2024-04-26 11:14:53 |
PipelineDevice | Regulator | 19 | 3 | 2024-04-26 11:14:53 |
PipelineDevice | Scrubber | 20 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Anode | 50 | 3 | 2024-04-26 11:14:53 |
PipelineDevice | Rectifier | 51 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Test Point | 52 | 6 | 2024-04-26 11:14:53 |
PipelineDevice | Decoupler | 53 | 3 | 2024-04-26 11:14:53 |
PipelineDevice | Grounding Point | 54 | 2 | 2024-04-26 11:14:53 |
PipelineDevice | Service Station | 21 | 3 | 2024-04-26 11:14:53 |
PipelineAssembly | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
PipelineAssembly | Compressor Station | 1 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Meter Setting | 2 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Regulator Station | 3 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Rural Tap | 4 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Town Border Station | 5 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Wellhead | 6 | 4 | 2024-04-26 11:15:28 |
PipelineAssembly | Pigging Structure | 7 | 3 | 2024-04-26 11:15:28 |
PipelineAssembly | Fitting Assembly | 8 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Pump Station | 9 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Valve Assembly | 10 | 2 | 2024-04-26 11:15:28 |
PipelineAssembly | Cathodic Assembly | 11 | 3 | 2024-04-26 11:15:28 |
PipelineAssembly | Storage Facility | 12 | 3 | 2024-04-26 11:15:28 |
PipelineJunction | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
PipelineJunction | Coupling | 1 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | Elbow | 2 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | End Cap | 3 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | Expansion Joint | 4 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Flange | 5 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Reducer | 6 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | Tee | 7 | 5 | 2024-04-26 11:15:54 |
PipelineJunction | Transition | 8 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Weld | 9 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Screw | 10 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Electro Stop | 11 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Plastic Fusion | 12 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Saddle | 13 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | Tank | 14 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Line Heater | 15 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Cooling System | 16 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Odorizer | 17 | 6 | 2024-04-26 11:15:54 |
PipelineJunction | Coupon | 18 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Dehydration Equipment | 19 | 4 | 2024-04-26 11:15:54 |
PipelineJunction | Drip | 20 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Connection Point | 21 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Union | 23 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Plug | 24 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Tap | 25 | 4 | 2024-04-26 11:15:54 |
PipelineJunction | Pipe Bend | 30 | 7 | 2024-04-26 11:15:54 |
PipelineJunction | Wire Junction | 50 | 3 | 2024-04-26 11:15:54 |
PipelineJunction | Insulation Junction | 51 | 2 | 2024-04-26 11:15:54 |
PipelineJunction | Olet | 26 | 4 | 2024-04-26 11:15:54 |
PipelineJunctionObject | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
PipelineLine | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
PipelineLine | Service Pipe | 1 | 13 | 2024-04-26 11:16:50 |
PipelineLine | Distribution Pipe | 2 | 13 | 2024-04-26 11:16:50 |
PipelineLine | Transmission Pipe | 3 | 8 | 2024-04-26 11:16:50 |
PipelineLine | Gathering Pipe | 4 | 12 | 2024-04-26 11:16:50 |
PipelineLine | Station Pipe | 5 | 8 | 2024-04-26 11:16:50 |
PipelineLine | Customer Pipe | 6 | 12 | 2024-04-26 11:16:50 |
PipelineLine | Riser Pipe | 7 | 8 | 2024-04-26 11:16:50 |
PipelineLine | Storage Pipe | 8 | 13 | 2024-04-26 11:16:50 |
PipelineLine | Pressure Sensor Pipe | 15 | 6 | 2024-04-26 11:16:50 |
PipelineLine | Bonding Line | 50 | 3 | 2024-04-26 11:16:50 |
PipelineLine | Test Lead Wire | 51 | 11 | 2024-04-26 11:16:50 |
PipelineLine | CP Cable | 52 | 3 | 2024-04-26 11:16:50 |
PipelineLine | Linear Anode | 53 | 3 | 2024-04-26 11:16:50 |
PipelineLine | AC Mitigation Wire | 54 | 2 | 2024-04-26 11:16:50 |
PipelineSubnetLine | Unknown | 0 | 0 | 2024-04-26 11:14:09 |
PipelineSubnetLine | Cathodic Protection | 1 | 0 | 2024-04-26 11:14:28 |
PipelineSubnetLine | System | 2 | 0 | 2024-04-26 11:14:28 |
PipelineSubnetLine | Pressure | 3 | 0 | 2024-04-26 11:14:28 |
PipelineSubnetLine | Isolation | 4 | 0 | 2024-04-26 11:14:28 |
PipelineEdgeObject | Unknown | 0 | 1 | 2024-04-26 11:14:09 |
Source Name | Asset Group Name | Asset Type Name | Asset Group Code | Asset Type Code | Terminal Configuration | Association Role | Delete Type | Containment Scale | Split Content | Connectivity Policy | Network Categories | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|
StructureJunction | Unknown | Unknown | 0 | 0 | 2024-04-26 11:12:45 | |||||||
StructureJunction | Pipe Muffler | Unknown | 1 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Muffler | Muffler | 1 | 1 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Anchor | Unknown | 2 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Anchor | Anchor | 2 | 41 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Support | Unknown | 3 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Support | Pipe Stand | 3 | 81 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Support | Roller | 3 | 82 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Hanger | Unknown | 4 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Hanger | Constant Spring | 4 | 121 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Hanger | Rigid | 4 | 122 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Hanger | Variable Spring | 4 | 123 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe End Connection | Unknown | 5 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe End Connection | End Seals | 5 | 161 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe End Connection | Skids & Straps | 5 | 162 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe End Connection | Spacers | 5 | 163 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Vault | Unknown | 6 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Vault | Vault | 6 | 201 | Container | Cascade | 25 | 2024-04-26 11:14:28 | ||||
StructureJunction | Pipe Box | Unknown | 7 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Box | Curb Box | 7 | 61 | Container | Restricted | 5 | 2024-04-26 11:14:28 | ||||
StructureJunction | Pipe Box | Curb Box with Stationary Rod | 7 | 62 | Container | Restricted | 5 | 2024-04-26 11:14:28 | ||||
StructureJunction | Pipe Box | Roadway | 7 | 63 | Container | Restricted | 5 | 2024-04-26 11:14:28 | ||||
StructureJunction | Pipe Box | Valve Box | 7 | 64 | Container | Restricted | 5 | 2024-04-26 11:14:28 | ||||
StructureJunction | Pipe Box | Meter Box | 7 | 65 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Sleeve | Unknown | 8 | 0 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Sleeve | Damage Repair | 8 | 131 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Sleeve | Leak Repair | 8 | 132 | 2024-04-26 11:14:28 | |||||||
StructureJunction | Pipe Access Point | Unknown | 10 | 0 | 2024-04-26 11:14:29 | |||||||
StructureJunction | Pipe Access Point | Manhole Cover | 10 | 231 | 2024-04-26 11:14:29 | |||||||
StructureJunction | Pipe Access Point | Door | 10 | 232 | 2024-04-26 11:14:29 | |||||||
StructureJunction | Pipe Access Point | Grate | 10 | 233 | 2024-04-26 11:14:29 | |||||||
StructureJunction | Pipe Access Point | Hand Hole | 10 | 234 | 2024-04-26 11:14:29 | |||||||
StructureJunction | Pipe Access Point | Lid | 10 | 235 | 2024-04-26 11:14:29 | |||||||
StructureBoundary | Unknown | Unknown | 0 | 0 | 2024-04-26 11:12:45 | |||||||
StructureBoundary | Pipe Station | Unknown | 1 | 0 | 2024-04-26 11:14:33 | |||||||
StructureBoundary | Pipe Station | Station Structure | 1 | 1 | Container | Cascade | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Pipe Station | Town Border Station | 1 | 2 | Container | Restricted | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Pipe Station | District Regulator Station | 1 | 3 | Container | Restricted | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Pipe Station | Commercial Regulator Station | 1 | 4 | Container | Restricted | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Pipe Station | Compressor Station | 1 | 5 | 2024-04-26 11:14:33 | |||||||
StructureBoundary | Pipe Vault | Unknown | 2 | 0 | 2024-04-26 11:14:33 | |||||||
StructureBoundary | Pipe Vault | Vault Boundary | 2 | 81 | Container | Cascade | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Pipe Processing Facility | Unknown | 3 | 0 | 2024-04-26 11:14:33 | |||||||
StructureBoundary | Pipe Processing Facility | Processing Facility | 3 | 41 | Container | Cascade | 25 | 2024-04-26 11:14:33 | ||||
StructureBoundary | Cathodic | Unknown | 4 | 0 | 2024-04-26 11:14:33 | |||||||
StructureBoundary | Cathodic | Grounding Mat | 4 | 101 | Container | Restricted | 250 | 2024-04-26 11:14:33 | ||||
StructureJunctionObject | Unknown | Unknown | 0 | 0 | 2024-04-26 11:12:45 | |||||||
StructureLine | Unknown | Unknown | 0 | 0 | 2024-04-26 11:12:45 | |||||||
StructureLine | Pipe Casing | Unknown | 1 | 0 | 2024-04-26 11:14:37 | |||||||
StructureLine | Pipe Casing | Casing | 1 | 1 | Container | Restricted | 100 | False | 2024-04-26 11:14:37 | |||
StructureEdgeObject | Unknown | Unknown | 0 | 0 | 2024-04-26 11:12:45 | |||||||
PipelineDevice | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 | |||||||
PipelineDevice | Excess Flow Valve | Unknown | 1 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Excess Flow Valve | Automatic Reset | 1 | 1 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Excess Flow Valve | Manual Reset | 1 | 2 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Excess Flow Valve | Breakaway Fitting | 1 | 3 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Meter | Unknown | 2 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Meter | Custody Transfer | 2 | 41 | Pipe Directional Dual Terminal | Meter;Subnetwork Controller | 2024-04-26 11:14:53 | |||||
PipelineDevice | Meter | Customer | 2 | 42 | Meter | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Meter | Utility | 2 | 43 | Meter | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Controllable Valve | Unknown | 3 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Controllable Valve | Bypass | 3 | 482 | Isolating;Valve | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Controllable Valve | System | 3 | 485 | Isolating;Valve | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Controllable Valve | Emergency | 3 | 483 | Pipe Bidirectional Dual Terminal | Isolating;Subnetwork Controller;Valve | 2024-04-26 11:14:53 | |||||
PipelineDevice | Controllable Valve | Meter | 3 | 486 | Valve | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Flow Valve | Unknown | 4 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Flow Valve | Check | 4 | 261 | Pipe Directional Dual Terminal | 2024-04-26 11:14:53 | ||||||
PipelineDevice | Flow Valve | Slam-shut | 4 | 262 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Unknown | 5 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Blow Off | 5 | 21 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Flare | 5 | 22 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Over Pressure Protection | 5 | 23 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Vacuum Pressure Protection | 5 | 24 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Relief Valve | Over Pressure and Vacuum Pressure Protection | 5 | 25 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Strainer | Unknown | 6 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Strainer | Strainer | 6 | 442 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Pressure Monitoring Device | Unknown | 8 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Pressure Monitoring Device | Pressure Monitoring Device | 8 | 81 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Lamp | Unknown | 9 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Lamp | Lamp | 9 | 121 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Compressor | Unknown | 10 | 0 | 2024-04-26 11:14:53 | |||||||
PipelineDevice | Compressor | Electric Motor | 10 | 161 | Pressure Increasing | Subnetwork Controller | 2024-04-26 11:14:53 | |||||
PipelineDevice | Compressor | Reciprocating Engine | 10 | 162 | Pressure Increasing | Subnetwork Controller | 2024-04-26 11:14:53 | |||||
PipelineDevice | Compressor | Turbine | 10 | 163 | Pressure Increasing | Subnetwork Controller | 2024-04-26 11:14:53 | |||||
PipelineDevice | Wellhead Source Flange | Unknown | 11 | 0 | Pipe Directional Dual Terminal | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Wellhead Source Flange | Flange | 11 | 201 | Pipe Directional Dual Terminal | Subnetwork Controller | 2024-04-26 11:14:54 | |||||
PipelineDevice | Controllable Tee | Unknown | 12 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Controllable Tee | Controllable Tee | 12 | 241 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Line Stopper | Unknown | 13 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Line Stopper | Line Stopper | 13 | 461 | Isolating | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Pump | Unknown | 18 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Pump | Booster | 18 | 401 | Pressure Increasing | Subnetwork Controller | 2024-04-26 11:14:54 | |||||
PipelineDevice | Pump | Primary | 18 | 402 | Pressure Increasing | Subnetwork Controller | 2024-04-26 11:14:54 | |||||
PipelineDevice | Regulator | Unknown | 19 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Regulator | Regulator | 19 | 521 | Pressure Reducing | Subnetwork Controller | 2024-04-26 11:14:54 | |||||
PipelineDevice | Regulator | Customer Regulator | 19 | 522 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Scrubber | Unknown | 20 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Scrubber | Scrubber | 20 | 561 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Anode | Unknown | 50 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Anode | ICCP | 50 | 901 | Anode | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Anode | Galvanic | 50 | 902 | Anode | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Rectifier | Unknown | 51 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Rectifier | Rectifier | 51 | 941 | CP Only;Rectifier | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Test Point | Unknown | 52 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Test Point | Above Ground | 52 | 981 | Terminal Block | CP Only;Subnetwork Controller;TestPoint | 2024-04-26 11:14:54 | |||||
PipelineDevice | Test Point | Buried | 52 | 982 | Terminal Block | CP Only;Subnetwork Controller;TestPoint | 2024-04-26 11:14:54 | |||||
PipelineDevice | Test Point | On Post | 52 | 983 | Terminal Block | CP Only;Subnetwork Controller;TestPoint | 2024-04-26 11:14:54 | |||||
PipelineDevice | Test Point | Pipeline Marker | 52 | 984 | Terminal Block | CP Only;Subnetwork Controller;TestPoint | 2024-04-26 11:14:54 | |||||
PipelineDevice | Test Point | Service Line | 52 | 985 | Terminal Block | CP Only;Subnetwork Controller;TestPoint | 2024-04-26 11:14:54 | |||||
PipelineDevice | Decoupler | Unknown | 53 | 0 | 2024-04-26 11:14:54 | |||||||
PipelineDevice | Decoupler | AC Decoupler | 53 | 921 | CP Only | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Decoupler | DC Decoupler | 53 | 922 | CP Only | 2024-04-26 11:14:54 | ||||||
PipelineDevice | Grounding Point | Unknown | 54 | 0 | 2024-04-26 11:14:55 | |||||||
PipelineDevice | Grounding Point | Grounding Point | 54 | 961 | CP Only | 2024-04-26 11:14:55 | ||||||
PipelineDevice | Service Station | Unknown | 21 | 0 | 2024-04-26 11:14:55 | |||||||
PipelineDevice | Service Station | Metered | 21 | 31 | 2024-04-26 11:14:55 | |||||||
PipelineDevice | Service Station | Metered and Regulated | 21 | 32 | 2024-04-26 11:14:55 | |||||||
PipelineAssembly | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 | |||||||
PipelineAssembly | Compressor Station | Unknown | 1 | 0 | 2024-04-26 11:15:28 | |||||||
PipelineAssembly | Compressor Station | Compressor Station | 1 | 1 | Container | Restricted | 200 | 2024-04-26 11:15:28 | ||||
PipelineAssembly | Meter Setting | Unknown | 2 | 0 | 2024-04-26 11:15:28 | |||||||
PipelineAssembly | Meter Setting | Meter Set | 2 | 41 | Container | Restricted | 5 | 2024-04-26 11:15:28 | ||||
PipelineAssembly | Regulator Station | Unknown | 3 | 0 | 2024-04-26 11:15:28 | |||||||
PipelineAssembly | Regulator Station | Regulator Station | 3 | 81 | Container | Restricted | 25 | 2024-04-26 11:15:28 | ||||
PipelineAssembly | Rural Tap | Unknown | 4 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Rural Tap | Rural Tap | 4 | 121 | Container | Restricted | 25 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Town Border Station | Unknown | 5 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Town Border Station | Town Border Station | 5 | 161 | Container | Restricted | 25 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Wellhead | Unknown | 6 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Wellhead | Mudline | 6 | 201 | Container | Restricted | 10 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Wellhead | Subsea | 6 | 202 | Container | Restricted | 10 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Wellhead | Surface | 6 | 203 | Container | Restricted | 10 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Pigging Structure | Unknown | 7 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Pigging Structure | Launcher | 7 | 241 | Container | Restricted | 25 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Pigging Structure | Receiver | 7 | 242 | Container | Restricted | 25 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Fitting Assembly | Unknown | 8 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Fitting Assembly | Service Tap | 8 | 281 | Container | Restricted | 10 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Pump Station | Unknown | 9 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Pump Station | Pump Station | 9 | 321 | Container | Restricted | 100 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Valve Assembly | Unknown | 10 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Valve Assembly | Valve Assembly | 10 | 61 | Container | Restricted | 25 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Cathodic Assembly | Unknown | 11 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Cathodic Assembly | Groundbed Assembly | 11 | 361 | Container | Restricted | 200 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Cathodic Assembly | Junction Box | 11 | 362 | Container | Restricted | 100 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Storage Facility | Unknown | 12 | 0 | 2024-04-26 11:15:29 | |||||||
PipelineAssembly | Storage Facility | Underground | 12 | 31 | Container | Restricted | 200 | 2024-04-26 11:15:29 | ||||
PipelineAssembly | Storage Facility | Tank Farm | 12 | 32 | Container | Restricted | 200 | 2024-04-26 11:15:29 | ||||
PipelineJunction | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 | |||||||
PipelineJunction | Coupling | Unknown | 1 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Coupling | Metal Coupling | 1 | 1 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Coupling | Plastic Coupling | 1 | 2 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Elbow | Unknown | 2 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Elbow | Metal Elbow | 2 | 41 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Elbow | Plastic Elbow | 2 | 42 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | End Cap | Unknown | 3 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | End Cap | Metal End Cap | 3 | 81 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | End Cap | Plastic End Cap | 3 | 82 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Expansion Joint | Unknown | 4 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Expansion Joint | Expansion Joint | 4 | 121 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Flange | Unknown | 5 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Flange | Metal Flange | 5 | 161 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Reducer | Unknown | 6 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Reducer | Metal Reducer | 6 | 201 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Reducer | Plastic Reducer | 6 | 202 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Tee | Unknown | 7 | 0 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Tee | Metal 3-Way | 7 | 241 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Tee | Metal 4-Way | 7 | 242 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Tee | Plastic 3-Way | 7 | 243 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Tee | Plastic 4-Way | 7 | 244 | 2024-04-26 11:15:54 | |||||||
PipelineJunction | Transition | Unknown | 8 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Transition | Transition | 8 | 281 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Weld | Unknown | 9 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Weld | Weld | 9 | 321 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Screw | Unknown | 10 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Screw | Screw | 10 | 361 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Electro Stop | Unknown | 11 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Electro Stop | Electro Stop | 11 | 401 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Plastic Fusion | Unknown | 12 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Plastic Fusion | Plastic Fusion | 12 | 441 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Saddle | Unknown | 13 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Saddle | Metal Saddle | 13 | 481 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Saddle | Plastic Saddle | 13 | 482 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Tank | Unknown | 14 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Tank | Tank | 14 | 521 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Line Heater | Unknown | 15 | 0 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Line Heater | Line Heater | 15 | 561 | 2024-04-26 11:15:55 | |||||||
PipelineJunction | Cooling System | Unknown | 16 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Cooling System | Cooling System | 16 | 601 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Unknown | 17 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Absorption Bypass | 17 | 641 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Injection Pump | 17 | 642 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Pulse | 17 | 643 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Rural Tap Odorizer | 17 | 644 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Odorizer | Wick | 17 | 645 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Coupon | Unknown | 18 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Coupon | Coupon | 18 | 681 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Dehydration Equipment | Unknown | 19 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Dehydration Equipment | Glycol Dehydration | 19 | 721 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Dehydration Equipment | Methanol Dehydration | 19 | 722 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Dehydration Equipment | Solid Absorption | 19 | 723 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Drip | Unknown | 20 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Drip | Drip | 20 | 761 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Connection Point | Unknown | 21 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Connection Point | Connection Point | 21 | 801 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Union | Unknown | 23 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Union | Metal Union | 23 | 341 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Plug | Unknown | 24 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Plug | Test Plug | 24 | 181 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Tap | Unknown | 25 | 0 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Tap | Cold Tap | 25 | 841 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Tap | Hot Tap | 25 | 842 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Tap | Full Encirclement | 25 | 843 | 2024-04-26 11:15:56 | |||||||
PipelineJunction | Pipe Bend | Unknown | 30 | 0 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Hot Bend | 30 | 51 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Cold Bend | 30 | 52 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Miter Bend | 30 | 53 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Field Bend | 30 | 54 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Wrinkle Bend | 30 | 55 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Pipe Bend | Factory Bend | 30 | 56 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Wire Junction | Unknown | 50 | 0 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Wire Junction | Bond Junction | 50 | 901 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Wire Junction | Test Lead | 50 | 902 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Insulation Junction | Unknown | 51 | 0 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Insulation Junction | Flange Insert | 51 | 941 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Olet | Unknown | 26 | 0 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Olet | Weldolet | 26 | 31 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Olet | Threadolet | 26 | 32 | 2024-04-26 11:15:57 | |||||||
PipelineJunction | Olet | Sockolet | 26 | 33 | 2024-04-26 11:15:57 | |||||||
PipelineJunctionObject | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 | |||||||
PipelineLine | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 | |||||||
PipelineLine | Service Pipe | Unknown | 1 | 0 | 2024-04-26 11:16:50 | |||||||
PipelineLine | Service Pipe | Bare Steel | 1 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Cast Iron | 1 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Coated Steel | 1 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Composite | 1 | 4 | Any Vertex | 2024-04-26 11:16:50 | ||||||
PipelineLine | Service Pipe | Copper | 1 | 5 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Ductile Iron | 1 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Plastic ABS | 1 | 7 | Any Vertex | 2024-04-26 11:16:50 | ||||||
PipelineLine | Service Pipe | Plastic Other | 1 | 8 | Any Vertex | 2024-04-26 11:16:50 | ||||||
PipelineLine | Service Pipe | Plastic PE | 1 | 9 | Any Vertex | 2024-04-26 11:16:50 | ||||||
PipelineLine | Service Pipe | Plastic PVC | 1 | 10 | Any Vertex | 2024-04-26 11:16:50 | ||||||
PipelineLine | Service Pipe | Reconditioned Cast Iron | 1 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Service Pipe | Wrought Iron | 1 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:50 | |||||
PipelineLine | Distribution Pipe | Unknown | 2 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Distribution Pipe | Bare Steel | 2 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Cast Iron | 2 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Coated Steel | 2 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Composite | 2 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Distribution Pipe | Copper | 2 | 5 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Ductile Iron | 2 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Plastic ABS | 2 | 7 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Distribution Pipe | Plastic Other | 2 | 8 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Distribution Pipe | Plastic PE | 2 | 9 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Distribution Pipe | Plastic PVC | 2 | 10 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Distribution Pipe | Reconditioned Cast Iron | 2 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Distribution Pipe | Wrought Iron | 2 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Unknown | 3 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Transmission Pipe | Bare Steel | 3 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Cast Iron | 3 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Coated Steel | 3 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Composite | 3 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Transmission Pipe | Ductile Iron | 3 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Reconditioned Cast Iron | 3 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Transmission Pipe | Wrought Iron | 3 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Unknown | 4 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Gathering Pipe | Bare Steel | 4 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Cast Iron | 4 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Coated Steel | 4 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Composite | 4 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Gathering Pipe | Ductile Iron | 4 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Plastic ABS | 4 | 7 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Gathering Pipe | Plastic Other | 4 | 8 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Gathering Pipe | Plastic PE | 4 | 9 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Gathering Pipe | Plastic PVC | 4 | 10 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Gathering Pipe | Reconditioned Cast Iron | 4 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Gathering Pipe | Wrought Iron | 4 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Unknown | 5 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Station Pipe | Bare Steel | 5 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Cast Iron | 5 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Coated Steel | 5 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Composite | 5 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Station Pipe | Ductile Iron | 5 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Reconditioned Cast Iron | 5 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Station Pipe | Wrought Iron | 5 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Unknown | 6 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Customer Pipe | Bare Steel | 6 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Cast Iron | 6 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Coated Steel | 6 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Composite | 6 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Customer Pipe | Ductile Iron | 6 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Plastic ABS | 6 | 7 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Customer Pipe | Plastic Other | 6 | 8 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Customer Pipe | Plastic PE | 6 | 9 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Customer Pipe | Plastic PVC | 6 | 10 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Customer Pipe | Reconditioned Cast Iron | 6 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Customer Pipe | Wrought Iron | 6 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Unknown | 7 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Riser Pipe | Bare Steel | 7 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Cast Iron | 7 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Coated Steel | 7 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Composite | 7 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Riser Pipe | Ductile Iron | 7 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Reconditioned Cast Iron | 7 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Riser Pipe | Wrought Iron | 7 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Unknown | 8 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Storage Pipe | Bare Steel | 8 | 1 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Cast Iron | 8 | 2 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Coated Steel | 8 | 3 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Composite | 8 | 4 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Storage Pipe | Copper | 8 | 5 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Ductile Iron | 8 | 6 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Plastic ABS | 8 | 7 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Storage Pipe | Plastic Other | 8 | 8 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Storage Pipe | Plastic PE | 8 | 9 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Storage Pipe | Plastic PVC | 8 | 10 | Any Vertex | 2024-04-26 11:16:51 | ||||||
PipelineLine | Storage Pipe | Reconditioned Cast Iron | 8 | 11 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Storage Pipe | Wrought Iron | 8 | 12 | Any Vertex | MetalPipe | 2024-04-26 11:16:51 | |||||
PipelineLine | Pressure Sensor Pipe | Unknown | 15 | 0 | 2024-04-26 11:16:51 | |||||||
PipelineLine | Pressure Sensor Pipe | Bare Steel | 15 | 1 | MetalPipe | 2024-04-26 11:16:51 | ||||||
PipelineLine | Pressure Sensor Pipe | Cast Iron | 15 | 2 | MetalPipe | 2024-04-26 11:16:51 | ||||||
PipelineLine | Pressure Sensor Pipe | Coated Steel | 15 | 3 | MetalPipe | 2024-04-26 11:16:51 | ||||||
PipelineLine | Pressure Sensor Pipe | Ductile Iron | 15 | 6 | MetalPipe | 2024-04-26 11:16:51 | ||||||
PipelineLine | Pressure Sensor Pipe | Wrought Iron | 15 | 12 | MetalPipe | 2024-04-26 11:16:51 | ||||||
PipelineLine | Bonding Line | Unknown | 50 | 0 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Bonding Line | Wire | 50 | 961 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Bonding Line | Strap | 50 | 962 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Unknown | 51 | 0 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Aqua | 51 | 901 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Blue | 51 | 902 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Forest | 51 | 903 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Green | 51 | 904 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Lavender | 51 | 905 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Orange | 51 | 906 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Pink | 51 | 907 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Red | 51 | 908 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Yellow | 51 | 909 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Test Lead Wire | Purple | 51 | 910 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | CP Cable | Unknown | 52 | 0 | 2024-04-26 11:16:52 | |||||||
PipelineLine | CP Cable | Rectifier Cable | 52 | 941 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | CP Cable | Decoupler Cable | 52 | 942 | CP Only | 2024-04-26 11:16:52 | ||||||
PipelineLine | Linear Anode | Unknown | 53 | 0 | 2024-04-26 11:16:52 | |||||||
PipelineLine | Linear Anode | Horizontal Anode | 53 | 981 | Any Vertex | CP Only | 2024-04-26 11:16:52 | |||||
PipelineLine | Linear Anode | Ribbon | 53 | 982 | Any Vertex | CP Only | 2024-04-26 11:16:52 | |||||
PipelineLine | AC Mitigation Wire | Unknown | 54 | 0 | 2024-04-26 11:16:52 | |||||||
PipelineLine | AC Mitigation Wire | Mitigation Wire | 54 | 921 | Any Vertex | CP Only | 2024-04-26 11:16:52 | |||||
PipelineEdgeObject | Unknown | Unknown | 0 | 0 | 2024-04-26 11:14:09 |
Category Name | Creation Time |
---|---|
Subnetwork Controller | 2024-04-26 11:12:44 |
Subnetwork Tap | 2024-04-26 11:12:44 |
Attribute Substitution | 2024-04-26 11:12:44 |
CP Only | 2024-04-26 11:17:56 |
Isolating | 2024-04-26 11:17:56 |
MetalPipe | 2024-04-26 11:17:56 |
Anode | 2024-04-26 11:17:56 |
Rectifier | 2024-04-26 11:17:56 |
TestPoint | 2024-04-26 11:17:56 |
Meter | 2024-04-26 11:17:56 |
Valve | 2024-04-26 11:17:56 |
Configuration Name | Configuration ID | Traversability Model | Default | Creation Time |
---|---|---|---|---|
Single terminal | 0 | Bidirectional | All | 2024-04-26 11:12:44 |
Pressure Reducing | 2 | Directional | All | 2024-04-26 11:17:56 |
Pressure Increasing | 3 | Directional | All | 2024-04-26 11:17:56 |
Pipe Directional Dual Terminal | 4 | Directional | All | 2024-04-26 11:17:56 |
Pipe Bidirectional Dual Terminal | 5 | Bidirectional | All | 2024-04-26 11:17:56 |
Terminal Block | 6 | Bidirectional | All | 2024-04-26 11:17:56 |
Configuration Name | Terminal Name | Terminal ID | Upstream |
---|---|---|---|
Single terminal | Single Terminal | 1 | |
Pressure Reducing | High Pressure In | 2 | True |
Pressure Reducing | Low Pressure Out | 3 | False |
Pressure Increasing | Low Pressure In | 4 | True |
Pressure Increasing | High Pressure Out | 5 | False |
Pipe Directional Dual Terminal | Inlet Port | 6 | True |
Pipe Directional Dual Terminal | Outlet Port | 7 | False |
Pipe Bidirectional Dual Terminal | Port One | 8 | |
Pipe Bidirectional Dual Terminal | Port Two | 9 | |
Terminal Block | Terminal One | 10 | |
Terminal Block | Terminal Two | 11 | |
Terminal Block | Terminal Three | 12 | |
Terminal Block | Terminal Four | 13 | |
Terminal Block | Terminal Five | 14 | |
Terminal Block | Terminal Six | 15 | |
Terminal Block | Terminal Seven | 16 | |
Terminal Block | Terminal Eight | 17 |
Name | ID | Usage Type | Data Type | Field Type | Inline | Domain Name | Nullable | Apportionable | Substitution Attribute | Bit Position | Bit Size | Junction ID | Edge ID | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Source ID | 1 | Source ID | Integer | Short Integer | True | False | False | 0 | 7 | 1 | 2 | 2024-04-26 11:12:44 | ||
Terminal ID | 2 | Terminal ID | Integer | Short Integer | False | False | False | 7 | 0 | 3 | 4 | 2024-04-26 11:12:44 | ||
Asset group | 3 | Asset Group | Integer | Short Integer | True | False | False | 7 | 10 | 5 | 6 | 2024-04-26 11:12:44 | ||
Asset type | 4 | Asset Type | Integer | Short Integer | True | False | False | 17 | 10 | 7 | 8 | 2024-04-26 11:12:44 | ||
Is subnetwork controller | 5 | Is Subnetwork Controller | Integer | Short Integer | True | False | False | 27 | 1 | 9 | 10 | 2024-04-26 11:12:44 | ||
Tier name | 6 | Tier Name | Integer | Short Integer | True | False | False | 28 | 6 | 11 | 12 | 2024-04-26 11:12:44 | ||
Shape length | 7 | Shape Length | Double | Double | False | False | True | 34 | 0 | 13 | 14 | 2024-04-26 11:12:44 | ||
Position from | 8 | Position From | Double | Double | False | False | False | 34 | 0 | 15 | 16 | 2024-04-26 11:12:44 | ||
Position to | 9 | Position To | Double | Double | False | False | False | 34 | 0 | 17 | 18 | 2024-04-26 11:12:44 | ||
Flow direction | 10 | Flow Direction | Integer | Short Integer | True | False | False | 34 | 2 | 19 | 20 | 2024-04-26 11:12:44 | ||
Cathodic Protection Traceability | 11 | Unknown | Integer | Short Integer | True | CP_Traceability | True | False | 36 | 2 | 21 | 22 | 2024-04-26 11:17:56 | |
Lifecycle Status | 12 | Unknown | Integer | Short Integer | False | False | False | 0 | 0 | 23 | 24 | 2024-04-26 11:17:56 | ||
Measured Length | 13 | Unknown | Double | Double | False | True | True | 0 | 0 | 25 | 26 | 2024-04-26 11:17:56 | ||
P:Accessible | 14 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 27 | 28 | 2024-04-26 11:17:56 | ||
P:Device Status | 15 | Unknown | Integer | Short Integer | True | Pipeline_Valve_Status | True | False | 39 | 1 | 29 | 30 | 2024-04-26 11:17:56 | |
P:MAOP Design | 16 | Unknown | Double | Double | False | True | False | 0 | 0 | 31 | 32 | 2024-04-26 11:17:56 | ||
P:MAOP Record | 17 | Unknown | Double | Double | False | True | False | 0 | 0 | 33 | 34 | 2024-04-26 11:17:56 | ||
P:MAOP Test | 18 | Unknown | Double | Double | False | True | False | 0 | 0 | 35 | 36 | 2024-04-26 11:17:56 | ||
P:Odorized | 19 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 37 | 38 | 2024-04-26 11:17:56 | ||
P:Operable | 20 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 39 | 40 | 2024-04-26 11:17:56 | ||
P:Piggable | 21 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 41 | 42 | 2024-04-26 11:17:56 | ||
P:Pinchable | 22 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 43 | 44 | 2024-04-26 11:17:56 | ||
P:Pipe Surface Area | 23 | Unknown | Double | Double | False | True | True | 0 | 0 | 45 | 46 | 2024-04-26 11:17:56 | ||
P:Pipe Volume | 24 | Unknown | Double | Double | False | True | True | 0 | 0 | 47 | 48 | 2024-04-26 11:17:56 |
Key | Value |
---|---|
Name | main.P_InspectionRange |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 442 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Inspection Range |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {A1B27827-3F60-4589-B6CE-2D5E42E1DCB5} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_InspectionRange describes the extent of patrolled pipeline. Multiple types of inspections can be performed during a single patrol event. The results of these inspections are tied to the inspection range by a relationship class. This allows a user to access all information gathered during the patrol of an inspection range. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | 0 | 0 | 15 | True | False | The operational status of the inspection range record. | |||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Any additional comments about the inspection range. | |||
inspectionstartdate | Inspection Start Date | Date | True | 0 | 0 | 8 | True | False | The date and time the inspection of the inspection range was initiated. | |||
inspectionenddate | Inspection End Date | Date | True | 0 | 0 | 8 | True | False | The date and time the inspection of the inspection range was completed. | |||
inspectionrangename | Inspection Range Name | String | True | 0 | 0 | 50 | True | False | The unique name assigned to the inspection range. | |||
inspectiontype | Inspection Type | String | True | Pipeline_Inspection_Range_Type | 0 | 0 | 30 | True | False | The type of inspection performed within the inspection range. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_109 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_InspectionRange_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_GasLeak |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 432 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Gas Leaks |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | LEAKCAUSE |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {A20CE60B-DF97-4F56-8651-A831FFDA793F} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_GasLeaks describes the identified location where natural gas is escaping the contained system. This is a field data collection activity commonly performed by a gas utilitys operations staff. The field investigation process will result in the verification of the presence of leaking gas. This is typically a singular location where the concentration of recorded methane is the greatest. Related information such as follow-up LeakInspections, Leak Sniff points, and the eventual Leak Repair are also commonly collected as part of the leak management process. The purpose of this feature class is to track the core leak data over the life cycle of the leak. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
leakcause | Leak Cause | Long Integer | Subtype | True | 0 | 0 | 0 | 4 | True | False | The official reported cause of the gas leak. The list of possible causes is consistent with U.S. DOT annual report classifications. | |
leakcausetype | Leak Cause Type | String | True | 0 | 0 | 50 | True | False | The subptye specific cause of the gas leak. | |||
leakstatus | Leak Status | String | True | 0 | 0 | 15 | True | False | The current status of the leak. | |||
timereported | Time Reported | Date | True | 0 | 0 | 8 | True | False | The date and time when the gas leak was reported to the gas company. | |||
timedispatched | Time Dispatched | Date | True | 0 | 0 | 8 | True | False | The date and time when gas company staff were dispatched to the location of the gas leak. | |||
timearrived | Time Arrived | Date | True | 0 | 0 | 8 | True | False | The date and time when gas company staff arrived at the location of the gas leak. | |||
timemadesafe | Time Made Safe | Date | True | 0 | 0 | 8 | True | False | The date and time when gas company staff were able to make the gas leak safe. | |||
address | Address | String | True | 0 | 0 | 100 | True | False | The house number, street name, and city name closest to the location where the leak was reported, for example, 123 E. Main St, Apple Valley. | |||
locationdescription | Location Description | String | True | 0 | 0 | 250 | True | False | A description of the location of the record. | |||
gasin | Gas In | String | True | 0 | 0 | 25 | True | False | The location where the leaking gas was discovered. | |||
originalleakclass | Original Leak Class | Short Integer | True | 0 | 0 | 2 | True | False | The classification by the gas field technician of the type of leak. | |||
methoddetected | Method Detected | String | True | 0 | 0 | 20 | True | False | The method used by the gas field technician to identify the location and concentration of leaking gas. | |||
gasmeasurement | Gas Measurement | Double | True | 0 | 0 | 8 | True | False | The highest concentration of methane gas recorded by the gas field technician while investigating the reported leak. | |||
gasmeasurementunits | Gas Measurement Units | Short Integer | True | 0 | 0 | 2 | True | False | The units of measurement used to determine the volume of leaking gas. | |||
surfacetype | Surface Type | String | True | 0 | 0 | 20 | True | False | The type of ground surface at the location determined by the gas field technician. | |||
probablesource | Probable Source | String | True | 0 | 0 | 25 | True | False | The pipeline asset which is most likely to have been the source of the leaking gas. | |||
revisedleakclass | Revised Leak Class | Short Integer | True | 0 | 0 | 2 | True | False | The classification approved by the gas operations supervisor as to the type of leak. | |||
revisedleakdate | Revised Leak Date | Date | True | 0 | 0 | 8 | True | False | The date and time the gas supervisor revised the leak class. | |||
revisedleaksupervisor | Revised Leak Supervisor | String | True | 0 | 0 | 50 | True | False | The name of the gas supervisor who approved the revision of the leak class. | |||
reportableincident | Reportable Incident | Short Integer | True | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the reported leak meets the DOT 191.3 requirement as a reportable incident. | ||
dotreportedindicator | DOT Reported Indicator | Short Integer | True | 2 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the reported leak has been reported to the U.S. DOT. | ||
federallandindicator | Federal Land Indicator | Short Integer | True | 2 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the reported leak was on federal government land. | ||
compdate | Compliance Date | Date | True | 0 | 0 | 8 | True | False | The compliance date is the calculated date when the gas leak is out of compliance. The compliance date is calculated by adding the frequency value plus the grace period to the timemadesafe. | |||
duedate | Due Date | Date | True | 0 | 0 | 8 | True | False | The date the gas leak is next due for inspection. duedate is calculated by adding the frequency value to the timemadesafe. | |||
frequency | Inspection Frequency | Short Integer | True | Pipeline_Leak_Inspect_Frequency | 0 | 0 | 2 | True | False | The duration as measured in days when the gas leak is required to be inspected next. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
ProbableSourceGlobalID | Probable Source GlobalID | GUID | True | 0 | 0 | 38 | True | False | ||||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_99 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_GasLeak_shape | True | True | shape |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Incorrect Operations | 1 | |
Material or Welds | 2 | |
Manufacturing | 3 | |
Construction | 4 | |
Equipment | 5 | |
Natural Forces | 6 | |
Corrosion | 7 | |
Other Outside Force Damage | 8 | |
Excavation Damage | 9 | |
Other | 10 |
Key | Value |
---|---|
Name | main.UPDMDevice_P_CPRectifierInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 484 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineDevice |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMDevice_GlobalID |
Destination Name | main.P_CPRectifierInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CPRectifierInspection |
Backward Path Label | PipelineDevice |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {A371EE8C-36BB-49DA-AEB6-5BCC4861BF33} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Rectifier | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_CouldAffectSegment |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 421 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Could Affect Segment |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {A3AA39B2-4537-4416-8224-1D205C2E81D2} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_CouldAffectSegment is intended to store the results of liquids HCA analysis. The P_CouldAffectSegment features represent pipeline segments that could affect a high consequence area. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 30 | True | False | The text value indicating the life cycle state of the object. Valid values are conceptual, proposed, active, inactive, and unknown. | ||
intersectiontype | Intersection Type | String | True | Pipeline_Could_Affect_Intersection | 0 | 0 | 50 | True | False | The text value indicating the type of intersection with an HCA that determined the could affect segment. Valid values are direct, indirect, and potential. | ||
couldaffectsegmenttype | Could Affect Segment Type | String | True | Pipeline_Could_Affect_Type | 0 | 0 | 50 | True | False | The text value indicating the type of HCA that determined the could affect segment. Valid values are high population, other population, ecological area, drinking water, and navigable waterway. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_88 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_CouldAffectSegment_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_AnomalyGroup_P_Anomaly |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 459 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_AnomalyGroup |
Origin Primary Key | GlobalID |
Origin Foreign Key | ANOMALYGROUP_GlobalID |
Destination Name | main.P_Anomaly |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_Anomaly |
Backward Path Label | P_AnomalyGroup |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {A5578E6D-EEE5-4859-A77D-C0A6D6E6A4E4} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_PipeCrossing |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 450 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Pipe Crossing |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | CROSSINGTYPE |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {A77C75C3-07A2-438B-A9E4-CEF49CA567FD} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_PipeCrossing describes the length of pipe segment that is intersected by another feature such as a road, river, and so on. Every pipeline company must track these types of features for right-of-way purposes, ownership purposes, and DOT and FERC safety regulations. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | 0 | 0 | 20 | True | False | The text value indicating the life cycle state of the object. Valid values are conceptual, proposed, active, inactive, and unknown. | |||
crossingtype | Crossing Type | Long Integer | Subtype | True | 0 | 0 | 0 | 4 | True | False | The subtype indicating the category of a crossing as pipe utility, topographic, transportation, or wired utility. | |
crossingfeaturetype | Crossing Feature Type | String | True | 0 | 0 | 50 | True | False | The text value indicating the specific feature type of the crossing. | |||
crossinglocation | Crossing Location | String | True | 0 | 0 | 10 | True | False | The text value indicating the location of the crossing relative to the pipeline. | |||
lineclearance | Line Clearance | Double | True | 0 | 0 | 8 | True | False | The value indicating the clearance between the crossing and pipeline. | |||
easementwidth | Easement Width | Double | True | 0 | 0 | 8 | True | False | The value indicating the width of the easement of the crossing. | |||
depthofpipe | Depth of Pipe | Double | True | 0 | 0 | 8 | True | False | The value indicating the depth of the pipeline at the crossing intersection. | |||
depthunits | Depth Units | Short Integer | True | 2 | 0 | 0 | 2 | True | False | The unit of measure used to define the depth of the record. | ||
depthofcrossingfeature | Depth of Crossing Feature | Double | True | 0 | 0 | 8 | True | False | The value indicating the depth of the crossing at the pipeline intersection. | |||
comments | Comments | String | True | 0 | 0 | 1000 | True | False | The nonstructured information about the crossing. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | |||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | ||||
diameter | Diameter | Double | True | 0 | 0 | 8 | True | False | ||||
diameterunits | Diameter Units | Short Integer | True | 0 | 0 | 2 | True | False | ||||
material | Material | String | True | Pipeline_ASTM_Material | 0 | 0 | 2 | True | False | |||
owner | Owner | String | True | 0 | 0 | 50 | True | False | ||||
wireheight | Wire Height | Double | True | 0 | 0 | 8 | True | False | ||||
heightunits | Height Units | Short Integer | True | 0 | 0 | 2 | True | False | ||||
casingindicator | Casing Indicator | Short Integer | True | 0 | 0 | 2 | True | False | ||||
angle | Angle | Double | True | 0 | 0 | 8 | True | False | ||||
name | Name | String | True | 0 | 0 | 50 | True | False | ||||
surfacetype | Surface Type | String | True | 0 | 0 | 50 | True | False | ||||
width | Width | Double | True | 0 | 0 | 8 | True | False | ||||
widthunits | Width Units | Short Integer | True | 0 | 0 | 2 | True | False | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | ||
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | ||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_117 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_PipeCrossing_shape | True | True | shape |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Pipe Utility | 1 | |
Wire Utility | 2 | |
Transportation | 3 | |
Topographic | 4 |
Key | Value |
---|---|
Name | main.UPDMAssembly_P_LineValveInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 481 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineAssembly |
Origin Primary Key | GLOBALID |
Origin Foreign Key | UPDMAssembly_GlobalID |
Destination Name | main.P_LineValveInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_LineValveInspection |
Backward Path Label | PipelineAssembly |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {A7AE366D-E06D-4592-93CD-7ED1EFF460A3} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Valve Assembly | 0 | 9999 | 0 | 9999 | |
2 | Compressor Station | 0 | 9999 | 0 | 9999 | |
3 | Fitting Assembly | 0 | 9999 | 0 | 9999 | |
4 | Meter Setting | 0 | 9999 | 0 | 9999 | |
5 | Pigging Structure | 0 | 9999 | 0 | 9999 | |
6 | Pump Station | 0 | 9999 | 0 | 9999 | |
7 | Regulator Station | 0 | 9999 | 0 | 9999 | |
8 | Rural Tap | 0 | 9999 | 0 | 9999 | |
9 | Town Border Station | 0 | 9999 | 0 | 9999 | |
10 | Unknown | 0 | 9999 | 0 | 9999 | |
11 | Wellhead | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_InspectionNote |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 441 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Inspection Note |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {A988E78E-5A30-409A-87C9-C07DECC8FE30} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_InspectionNote describes where additional information can be captured during an inspection that is not necessarily related to the inspection. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectiondate | Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date the inspection was performed. | |||
inspector | Inspector | String | True | 0 | 0 | 30 | True | False | The name of the field technician who performed the inspection. | |||
notetype | Note Type | String | True | Pipeline_Inspection_Note_Type | 0 | 0 | 30 | True | False | The type of inspection being performed when the note was captured. | ||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Any additional comments the field technician provides. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_108 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_InspectionNote_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_InlineInspection |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 440 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Inline Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {B6C3F5A9-D625-47AE-8160-B91B0B394779} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_InlineInspection describes the length or range of a single inline inspection event on a pipe segment. Multiple inline inspections can be grouped together as inline inspection ranges. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
startdate | Start Date | Date | True | 0 | 0 | 8 | True | False | The start date of the ILI run. | |||
enddate | End Date | Date | True | 0 | 0 | 8 | True | False | The end date of the ILI run. | |||
ilivendor | ILI Vendor | String | True | 0 | 0 | 50 | True | False | The survey vendor performing the ILI run. | |||
tooltype | Tool Type | String | True | 0 | 0 | 50 | True | False | The type of pigging device used for the ILI run. | |||
startodo | Start Odometer | Double | True | 0 | 0 | 8 | True | False | The odometer reading on the pigging device at the start of the ILI run. | |||
endodo | End Odometer | Double | True | 0 | 0 | 8 | True | False | The odometer reading on the pigging device at the end of the ILI run. | |||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Additional description of the ILI run. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_107 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_InlineInspection_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_InspectionRange_P_AnomalyGroup |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 469 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_InspectionRange |
Origin Primary Key | GlobalID |
Origin Foreign Key | INSPECTIONRANGE_GlobalID |
Destination Name | main.P_AnomalyGroup |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_AnomalyGroup |
Backward Path Label | P_InspectionRange |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {C49095E7-B033-4098-B917-DF0F570067C6} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_Elevation |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 428 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Elevation |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {C66F717F-634B-4513-8E24-5B28CD6FF604} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_Elevation describes surface height information at a discrete location. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
featureelevation | Feature Elevation | Double | True | 0 | 0 | 8 | True | False | The measured vertical distance to the top of a physical object from a common reference such as mean sea level. | |||
groundelevation | Ground Elevation | Double | True | 0 | 0 | 8 | True | False | The measured vertical distance of the surface from a common reference such as mean sea level. | |||
waterelevation | Water Elevation | Double | True | 0 | 0 | 8 | True | False | The measured vertical distance of the surface or top of the water body from a common reference such as mean sea level. | |||
measurementunits | Measurement Units | Short Integer | True | Units_for_Length | 0 | 0 | 2 | True | False | The units of measure used for determining elevation. | ||
measurementdate | Date Measured | Date | True | 0 | 0 | 8 | True | False | The date the measurements were captured. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_95 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_Elevation_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_IdentifiedIssue__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 468 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_IdentifiedIssue |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_IdentifiedIssue__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {CF4F80DA-5B9B-49DC-8EF3-54C0838026A7} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_ExposedPipeInspect |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 431 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Exposed Pipe Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {D043FB9C-B970-47AC-8AEC-ABA44066D419} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_ExposedPipeInspect represents an exposed pipe inspection. An exposed pipe inspection is done during construction or maintenance activity. This is a field data collection activity commonly performed by the utilitys operations staff. Once the pipe is exposed, it is inspected for safe operation. Some inspections are required by DOT regulations, such as internal and external corrosion. In addition, Distribution Integrity Management (DIM) requires the collection of additional information during normal operations to gain critical knowledge of the system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectionnumber | Inspection Number | String | True | 0 | 0 | 20 | True | False | The inspection management system-generated unique ID. | |||
inspectiondate | Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date the exposed pipe inspection was performed. | |||
inspectedby | Inspected By | String | True | 0 | 0 | 20 | True | False | The name of the field technician who performed the inspection. | |||
lengthexposed | Length Exposed | Double | True | 0 | 0 | 8 | True | False | The length of pipe that is exposed. | |||
pipedepth | Pipe Depth | Double | True | 0 | 0 | 8 | True | False | The depth of the pipe below the ground surface. | |||
pittingdepth | Pitting Depth | Double | True | 0 | 0 | 8 | True | False | The inspection measured depth of identified pitting. | |||
soiltype | Soil Type | String | True | Pipeline_Soil_Type | 0 | 0 | 20 | True | False | The type of soil in which the pipe is situated. | ||
coatingcondition | Coating Condition | String | True | Pipeline_Coating_Condition | 0 | 0 | 25 | True | False | The description of the coating condition. | ||
corrosioncondition | Corrosion Condition | String | True | Pipeline_Corrosion_Condition | 0 | 0 | 25 | True | False | The inspection-determined condition of identified corrosion. | ||
corrosionextent | Corrosion Extent | String | True | Pipeline_Corrosion_Extent | 0 | 0 | 20 | True | False | The inspection-determined extent of corrosion. | ||
pipecondition | Pipe Condition | String | True | Pipeline_Pipe_Condition | Normal | 0 | 0 | 20 | True | False | The inspection-determined condition of the pipe. This includes plastic pipes where cracking is possible. | |
jointtrench | Joint Trench | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the exposed pipe was installed in a joint trench with other utilities. | |||
trenchencroachment | Joint Encroachment | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether third-party utilities are in close proximity to the gas line. | |||
repairorderrequired | Repair Order Required | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether a repair order is required. | |||
comments | COMMENTS | String | True | 0 | 0 | 255 | True | False | The user or inspection comments. | |||
pipeexposure_globalid | Pipe Exposure GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The PipeExposure feature class globalid value of the record with which the field inspection is associated. | ||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_431_PIPEEXPO | False | True | pipeexposure_globalid |
UUID_98 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ExposedPipeInspect_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_InspectionRange_P_PipeExposure |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 470 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_InspectionRange |
Origin Primary Key | GlobalID |
Origin Foreign Key | INSPECTIONRANGE_GlobalID |
Destination Name | main.P_PipeExposure |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_PipeExposure |
Backward Path Label | P_InspectionRange |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {D0A8AAD6-59CC-4F0B-B6FA-FE1DFFDC1EBE} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_DOTClass |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 424 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | DOT Class |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {D50A6427-A84A-4556-858A-E432DF5953FD} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_DOTClass describes the segments indicating the calculated or assigned Department of Transportation Office of Pipeline Safety class designations. This is an important designation of the pipe segment that defines and determines how this is treated and maintained for operational as well as regulatory practice. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
classtype | Class Type | Short Integer | True | Pipeline_DOT_Class_Type | 0 | 0 | 2 | True | False | The type of DOT class determined on the pipe segment. Valid values are Class 1, Class 2, Class 3, and Class 4. | ||
classsource | Class Source | String | True | Pipeline_DOT_Class_Source | 0 | 0 | 20 | True | False | The text value indicating the source of DOT class determined. Valid values are calculated, manual, unknown (verified), and unknown. | ||
classlength | Class Length | Double | True | 0 | 0 | 8 | True | False | The length of an individual DOT segment. | |||
corridorwidth | Corridor Width | Double | True | 0 | 0 | 8 | True | False | The corridor width of an individual DOT segment. | |||
datecalculated | Date Calculated | Date | True | 0 | 0 | 8 | True | False | The date and time the DOT segment was originally calculated. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_91 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_DOTClass_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_MAOPCalcRange |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 445 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | MAOP Calculated Range |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {D71D8F78-79B4-4225-8430-5E208E802906} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_MAOPCalcRange describes the length or range of an MAOP calculation for the pipe system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
pressureestablishedby | Pressure Established By | String | True | Pipeline_MAOP_Pressure_Estab_By | 0 | 0 | 50 | True | False | The text value indicating the method of establishing MAOP. Valid values are design, certificate, grandfather, special permit, pressure type, other, unknown, operator assigned, and historical. | ||
documentmaturityindex | Document Maturity Index | String | True | Pipeline_Document_Maturity_Index | 0 | 0 | 50 | True | False | The text value rating the quality of documentation supporting the MAOP. Valid values are high, medium, and low. | ||
maopdesign | MAOP Design | Double | True | 0 | 0 | 8 | True | False | The maximum allowable operating pressure as defined during design. | |||
maoptest | MAOP Test | Double | True | 0 | 0 | 8 | True | False | The tested maximum allowable operating pressure during installation. | |||
maoprecord | MAOP Record | Double | True | 0 | 0 | 8 | True | False | The maximum allowable operating pressure under which the record is currently operating. | |||
maopunitofmeasure | MAOP Unit of Measure | Short Integer | True | Units_for_Pressure | 0 | 0 | 2 | True | False | The unit of measure for defining MAOP. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_112 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_MAOPCalcRange_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_GasLeak_P_P_GasLeakInspect |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 465 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_GasLeak |
Origin Primary Key | GlobalID |
Origin Foreign Key | GASLEAK_GlobalID |
Destination Name | main.P_GasLeakInspect |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_GasLeakInspect |
Backward Path Label | P_GasLeak |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {D7719AC6-7ADC-4681-9A7D-581DE976B80B} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Construction | 0 | 9999 | 0 | 9999 | |
2 | Corrosion | 0 | 9999 | 0 | 9999 | |
3 | Equipment | 0 | 9999 | 0 | 9999 | |
4 | Excavation Damage | 0 | 9999 | 0 | 9999 | |
5 | Incorrect Operations | 0 | 9999 | 0 | 9999 | |
6 | Manufacturing | 0 | 9999 | 0 | 9999 | |
7 | Material or Welds | 0 | 9999 | 0 | 9999 | |
8 | Natural Forces | 0 | 9999 | 0 | 9999 | |
9 | Other | 0 | 9999 | 0 | 9999 | |
10 | Other Outside Force Damage | 0 | 9999 | 0 | 9999 | |
11 | Unknown | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_ILISurveyGroup_P_ILISurveyReadings |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 467 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_ILISurveyGroup |
Origin Primary Key | GlobalID |
Origin Foreign Key | ILISURVEYGROUP_GlobalID |
Destination Name | main.P_ILISurveyReadings |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_ILISurveyReadings |
Backward Path Label | P_ILISurveyGroup |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {D8E5B31C-A24C-48CD-86B0-B05A859C88E2} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.UPDMLine_P_CPBondInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 490 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.PipelineLine |
Origin Primary Key | GlobalID |
Origin Foreign Key | UPDMLine_GlobalID |
Destination Name | main.P_CPBondInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CPBondInspection |
Backward Path Label | PipelineLine |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {EC84C83E-C7AA-4266-9923-2E1B8632A2BF} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | AC Mitigation Wire | 0 | 9999 | 0 | 9999 | |
2 | Bonding Line | 0 | 9999 | 0 | 9999 | |
3 | CP Cable | 0 | 9999 | 0 | 9999 | |
4 | Linear Anode | 0 | 9999 | 0 | 9999 | |
5 | Test Lead Wire | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.P_GasLeak__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 466 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_GasLeak |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_GasLeak__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {ED552B31-9CF2-458B-A72E-23789B679AE1} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.PipelineSubnetLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 380 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Pipeline Subnet Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | TIERNAME |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {ED627562-72D0-4894-A4BB-55B1C8C48B1A} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The system maintained set of subnetworks. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
SUBNETWORKNAME | Subnetwork name | String | False | Unknown | 0 | 0 | 64 | False | True | The name of the Utility Network managed subnetwork that the record participates in. | ||
ISDIRTY | Is dirty | Short Integer | False | Network_6_IsDirty | 1 | 0 | 0 | 2 | False | True | System managed value indicating whether edits have been performed on the features comprising the subnetwork feature since it was last updated. | |
TIERNAME | Tier name | Short Integer | Subtype | False | 0 | 0 | 0 | 2 | False | True | If the device is of an asset group/asset type which has been designated as a subnetwork controller within the Utility Network configuration, this is the name of the tier to which the subnetwork controller is associated. | |
SUBNETWORKCONTROLLERNAMES | Subnetwork controller names | String | False | Unknown | 0 | 0 | 1073741822 | False | True | The names of the subnetwork controllers which define the sources for the subnetwork. | ||
LASTUPDATESUBNETWORK | Last update subnetwork | Date | True | 0 | 0 | 8 | False | True | The date and time of the last successfully updating of the subnetwork. | |||
LASTACKEXPORTSUBNETWORK | Last ack export subnetwork | Date | True | 0 | 0 | 8 | False | True | ||||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
totallength | Total Length | Double | True | 0 | 0 | 8 | True | False | The total length based on shape_length of the pipe features comprising the subnetwork. | |||
maopdesign | MAOP Design | Double | True | 0 | 0 | 8 | True | False | The maximum allowable operating pressure as defined during design. | |||
numbervalves | Number of Valves | Long Integer | True | 0 | 0 | 4 | True | False | The number of controllable valves within the subnetwork. | |||
numbermeters | Number of Meters | Long Integer | True | 0 | 0 | 4 | True | False | The number of meters within the subnetwork. | |||
maoprecord | MAOP Record | Double | True | 0 | 0 | 8 | True | False | The maximum allowable operating pressure under which the record is currently operating. | |||
maoptest | MAOP Test | Double | True | 0 | 0 | 8 | True | False | The tested maximum allowable operating pressure during installation. | |||
totalsurfacearea | Total Surface Area | Double | True | 0 | 0 | 8 | True | False | The total surface area of the metallic pipe features of the subnetwork. | |||
totalpipevolume | Total Pipe Volume | Double | True | 0 | 0 | 8 | True | False | The total pipe volume of the pipe features of the subnetwork. | |||
countrectifiers | Number of Rectifier | Long Integer | True | 0 | 0 | 4 | True | False | The total count cathodic protection rectifier features in the subnetwork. | |||
counttestpoint | Number of Test Points | Long Integer | True | 0 | 0 | 4 | True | False | The total count of the cathodic protection test points in the subnetwork. | |||
countanodes | Number of Anodes | Long Integer | True | 0 | 0 | 4 | True | False | The total count of the cathodic protection anodes in the subnetwork. | |||
totalmeasurelength | Total Measured Length | Double | True | 0 | 0 | 8 | True | False | The sum of the MeasureLength PipelineLine | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_47 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__PipelineSubnetLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Cathodic Protection | 1 | |
System | 2 | |
Pressure | 3 | |
Isolation | 4 |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name |
---|---|---|---|---|
Unknown | 0 | SUBNETWORKNAME | Unknown | |
Unknown | 0 | ISDIRTY | 1 | Network_6_IsDirty |
Unknown | 0 | SUBNETWORKCONTROLLERNAMES | Unknown | |
Cathodic Protection | 1 | SUBNETWORKNAME | Unknown | |
Cathodic Protection | 1 | ISDIRTY | 1 | Network_6_IsDirty |
Cathodic Protection | 1 | SUBNETWORKCONTROLLERNAMES | Unknown | |
System | 2 | SUBNETWORKNAME | Unknown | |
System | 2 | ISDIRTY | 1 | Network_6_IsDirty |
System | 2 | SUBNETWORKCONTROLLERNAMES | Unknown | |
Pressure | 3 | SUBNETWORKNAME | Unknown | |
Pressure | 3 | ISDIRTY | 1 | Network_6_IsDirty |
Pressure | 3 | SUBNETWORKCONTROLLERNAMES | Unknown | |
Isolation | 4 | SUBNETWORKNAME | Unknown | |
Isolation | 4 | ISDIRTY | 1 | Network_6_IsDirty |
Isolation | 4 | SUBNETWORKCONTROLLERNAMES | Unknown |
Key | Value |
---|---|
Name | main.P_ConsequenceSegment |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 419 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Consequence Segment |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | METHOD |
Default Subtype | Installed |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {EDB63303-2282-4B5F-98BF-2D778EC5EBC7} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polyline feature class P_ConsequenceSegment describes the segments derived from an HCA calculation or assignment. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | 0 | 0 | 15 | True | False | The text value indicating the life cycle state of the object. Valid values are conceptual, proposed, active, inactive, and unknown. | |||
habitablebuildingcount | Habitable Building Count | Long Integer | True | 0 | 0 | 4 | True | False | The number of structures intended for human occupancy that created the individual HCA segment. | |||
calculatedlength | Calculated Length | Double | True | 0 | 0 | 8 | True | False | The length of an individual consequence segment. | |||
datecalculated | Date Calculated | Date | True | 0 | 0 | 8 | True | False | The date and time the consequence segment was originally calculated. | |||
maop | Date Calculated | Double | True | 0 | 0 | 8 | True | False | The maximum allowable operating pressure used for the consequence segment calculation. | |||
pir | Potential Impact Radius | Double | True | 0 | 0 | 8 | True | False | The potential impact radius of the consequence segment from the HCA calculation. | |||
pirfactor | PIR Factor | Double | True | 0 | 0 | 8 | True | False | A tolerance factor to account for variation in spatial data accuracy of the features used to determine whether a segment is HCA. | |||
type | Type | String | True | 0 | 0 | 40 | True | False | The type of HCA on the pipe segment. Valid values are class 3 or 4 designation, identified site, sliding circle, sliding circle and class designation, sliding circle and identified site, engineering assessment, and unknown. | |||
method | Method | Long Integer | Subtype | True | 0 | 0 | 0 | 4 | True | False | The feature class subtype that defines the technique used to describe the consequence segment. Valid subtypes are installed, calculated, and approved. | |
outsidediameter | Outside Diameter | Double | True | 0 | 0 | 8 | True | False | The outer edge-to-outer edge measured length of a straight line through the center of the pipe orifice. | |||
consequenceareatype | Consequence Area Type | String | True | 0 | 0 | 30 | True | False | The U.S. federal classification of whether the consequent is classified as a high consequence segment or a medium consequence segment. | |||
regulatorytype | Regulatory Type | Short Integer | True | 0 | 0 | 2 | True | False | The value indicating the regulatory status of the record. This is used by the Facility Reporting tools to differentiate between Distribution, Transmission, Offshore Transmission, Gathering, and Offshore Gathering pipe. | |||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_86 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_ConsequenceSegment_shape | True | True | shape |
Name | Code | Details |
---|---|---|
Installed | 0 | |
Calculated | 1 | |
Approved | 2 |
Key | Value |
---|---|
Name | main.P_Coupon |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 422 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Coupon |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {F1B5BCC4-1FE3-4122-95DD-9034F165AF9A} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_Coupon describes the location where a sample of the pipe is cut from the metal pipe to determine the extent of internal corrosion. A coupon is typically extracted as part of an exposed pipe inspection. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
precentofgraph | Percent of Graph | Double | True | 0 | 0 | 8 | True | False | The percent of graphitization. | |||
wallthickness | Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturer's defined thickness of the pipe wall. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | ||||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | ||||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | ||||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | ||||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | ||||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | ||||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | ||||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | ||||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | ||||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | ||||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | ||||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | ||||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_89 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_Coupon_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_PipeCrossing_P_CrossingInspection |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 473 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.P_PipeCrossing |
Origin Primary Key | GlobalID |
Origin Foreign Key | PIPECROSSING_GlobalID |
Destination Name | main.P_CrossingInspection |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | P_CrossingInspection |
Backward Path Label | P_PipeCrossing |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {F613642C-1D33-4294-88FC-067B553F1364} |
Class ID | |
Extension Class ID |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | Pipe Utility | 0 | 9999 | 0 | 9999 | |
2 | Topographic | 0 | 9999 | 0 | 9999 | |
3 | Transportation | 0 | 9999 | 0 | 9999 | |
4 | Unknown | 0 | 9999 | 0 | 9999 | |
5 | Wire Utility | 0 | 9999 | 0 | 9999 |
Key | Value |
---|---|
Name | main.PipelineLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 377 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Pipeline Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 905733.2044296792 |
Y-Min | 1812448.4930938068 |
X-Max | 1068481.2280143457 |
Y-Max | 1879446.6556523335 |
Catalog ID | {F9359364-26DA-48B8-9C71-FA9471BA7AAD} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within assemblies |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | The geodatabase generated and maintained unique identifier value. | ||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | The geodatabase subtype field. The subtype field models the engineering system type of the pipe segments. | |
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | The value indicating the material type of the pipe segment. | ||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | An indicator of the type of utility network association to which the line feature participates. | |
ISCONNECTED | Is connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | A Boolean true/false value indicating whether the pipe segment is connected to a subnetwork controller device. | |
FROMDEVICETERMINAL | From device terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | If the first vertex of the line is connected to a device with a terminal definition. This integer value will indicate which port id of the terminal the pipe segment has been associated too. | |
TODEVICETERMINAL | To device terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | If the last vertex of the line is connected to a device with a terminal definition. This integer value will indicate which port id of the terminal the pipe segment has been associated too. | |
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. This is the primary key value for relationships to child tables. | ||
CPSubnetworkName | CP Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the cathodic protection tier subnetwork where the pipe segment is located. | |
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SystemSubnetworkName | System Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the system tier subnetwork where the pipe segment is located. | |
PressureSubnetworkName | Pressure Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the pressure tier subnetwork where the pipe segment is located. | |
IsolationSubnetworkName | Isolation Zone Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The name of the isolation zone tier subnetwork where the record is located. | |
regulatorytype | Regulatory Type | Short Integer | True | Pipeline_Regulatory_Type | 0 | 0 | 2 | True | False | The value indicating the regulatory status of the pipe segment. This is used by the Facility Reporting tools to differentiate between Distribution, Transmission, Offshore Transmission, Gathering, and Offshore Gathering pipe. | ||
pinchable | Pinchable | Short Integer | False | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the pipe segment is made of a material that can be pinched during emergency operations. | |
piggable | Piggable | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the pipe segment can be pigged. | |||
warningtape | Warning Tape | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether a warning tape was installed with the pipe segment. | |||
tracerwire | Tracer Wire | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether a tracer wire was installed with the pipe segment. | |||
seamtype | Seam Type | Short Integer | True | Pipeline_Seam_Type | 0 | 0 | 2 | True | False | The type of seam used during the manufacture of the pipe. | ||
girthweldtype | Girth Weld Type | Short Integer | True | Pipeline_Girth_Weld_Type | 0 | 0 | 2 | True | False | The type of welding procedure and welding equipment used to weld the records. | ||
longitudinalseamorientation | Longitudinal Seam Orientation | Double | True | Pipeline_Seam_Orientation | 0 | 0 | 8 | True | False | The clock position of the weld along a pipe length of the installed pipe if the pipe is not a seamless pipe. A clock position of 12:00 indicates the weld seam is on top of the pipe, and a clock position of 6:00 indicates the weld seam is at the bottom of the pipe. | ||
pipesurfacearea | Pipe Surface Area | Double | False | 0 | 0 | 0 | 8 | True | False | The exterior surface area of the pipe segment. This is a network attribute in the utility network configuration. | ||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the construction of the pipe was completed. | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the pipe segment was put into production. | |||
installationmethod | Installation Method | Short Integer | True | 0 | 0 | 2 | True | False | The construction process used to install the pipe segment. | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | A layer-specific textual unique identifier. | |||
ownedby | Owned By | Short Integer | True | Asset_Owner | 1 | 0 | 0 | 2 | True | False | The name of the organization with ownership of the pipe segment. In most instances, this will be the name of your organization. | |
maintby | Maintained By | Short Integer | True | Asset_Manager | 1 | 0 | 0 | 2 | True | False | The name of the organization responsible for the operation and maintenance of the pipe segment. In most instances, this will be the name of your organization. Coded Value Domain: Asset_Manager | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 8 | 0 | 0 | 2 | True | False | The text value indicating the life cycle state of the pipe feature. | |
nominaldiameter | Nominal Diameter | Double | True | 0 | 0 | 8 | True | False | The generalized edge-to-edge measured length of a straight line through the center of the pipe orifice. | |||
operatingpressure | Operating Pressure | Double | True | Pipeline_Pressure_Range | 0 | 0 | 8 | True | False | The nominal pressure at which the pipe system operates. | ||
maopdesign | MAOP Design | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure as defined during design. | |
maoptest | MAOP Test | Double | True | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The tested maximum allowable operating pressure during installation. | |
maoprecord | MAOP Record | Double | False | Pipeline_Pressure_Range | 0 | 0 | 0 | 8 | True | False | The maximum allowable operating pressure under which the pipe segment is currently operating. | |
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The end-to-end distance of the pipe segment. | |||
lengthsource | Length Source | Short Integer | True | Pipeline_Length_Source | 0 | 0 | 2 | True | False | The source of the distance value used to define the pipe segments length. | ||
wallthickness | Wall Thickness | Double | True | 0 | 0 | 8 | True | False | The manufacturers defined width of the pipe wall. Subtype-specific coded value domains. | |||
wallthickness2 | Wall Thickness2 | Double | True | 0 | 0 | 8 | True | False | The manufacturer's defined thickness of the exterior wall of the record. | |||
outsidediameter | Outside Diameter | Double | True | 0 | 0 | 8 | True | False | The outer edge-to-outer edge measured length of a straight line through the center of the pipe orifice. | |||
barcode | Barcode | String | True | 0 | 0 | 16 | True | False | The ASTM F2897-15 code read from the bar code on the pipe segment. | |||
manufacturer | Manufacturer | String | True | 0 | 0 | 15 | True | False | The organization that built the pipe segment. | |||
manufacturerlotno | Manufacturer Lot # | Long Integer | True | 0 | 0 | 4 | True | False | The manufacturer lot number from which the pipe segment was created. | |||
manufacturedate | Manufacture Date | Date | True | 0 | 0 | 8 | True | False | The date the pipe segment was created by the manufacturer. | |||
manufacturecomponent | Manufacture Component | String | True | 0 | 0 | 2 | True | False | The manufacturer-specified, industry standard specification that was followed when the pipe segment was created. Subtype-specific coded value domains are based on the ASTM F2897 bar code derived values. | |||
material | Material and Pipe Grade | String | True | 0 | 0 | 2 | True | False | A specific coded value domains are based on ASTM F2897 list of pipe grades. | |||
pipevolume | Pipe Volume | Double | False | 0 | 0 | 0 | 8 | True | False | The interior volume of the pipe segment. | ||
gauge | Gauge | Short Integer | True | 0 | 0 | 2 | True | False | The diameter size of the wire. | |||
depth | Depth | Double | True | 0 | 0 | 8 | True | False | The distance below the ground cover where the record is buried. | |||
criticalindicator | Critical Indicator | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the pipe segment is considered critical to the operation of the overall system. | |||
notes | Notes | String | True | 0 | 0 | 2000 | True | False | Additional information about the record. | |||
commodity | Commodity | Short Integer | True | 0 | 0 | 2 | True | False | The federal description for the type of fluid or gas being transported by the pipe segment. | |||
odorized | Odorized | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | |||
actualinternaldiameter | Actual Internal Diameter | Double | True | 0 | 0 | 8 | True | False | The manufacturers defined internal edge-to-edge measurement of a straight line through the centroid of the pipe. | |||
originalcoverdepth | Original Cover Depth | Double | True | 0 | 0 | 8 | True | False | The depth below the ground surface at which the pipe was placed during original construction. | |||
primarycoatingtype | Primary Coating Type | String | True | 0 | 0 | 30 | True | False | The initial type of protective coating applied to the exterior of the pipe segment. | |||
primarycoatingappdate | Primary Coating App Date | Date | True | 0 | 0 | 8 | True | False | The date the initial type of protective coating was applied to the pipe segment. | |||
secondarycoatingtype | Secondary Coating Type | String | True | 0 | 0 | 30 | True | False | The secondary type of protective coating applied to the exterior of the pipe segment. | |||
secondarycoatingappdate | Secondary Coating App Date | Date | True | 0 | 0 | 8 | True | False | The date the secondary type of protective coating was applied to the pipe segment. | |||
tertiarycoatingtype | Tertiary Coating Type | String | True | 0 | 0 | 30 | True | False | The third type of protective coating applied to the exterior of the pipe segment. | |||
tertiarycoatingappdate | Tertiary Coating App Date | Date | True | 0 | 0 | 8 | True | False | The date the third type of protective coating was applied to the pipe segment. | |||
designclass | Design Class | Short Integer | True | 0 | 0 | 2 | True | False | The U.S. DOT class location for which the pipe segment was designed. Pipelines in the U.S. are designed for the expected DOT class of the area where the pipe segment will be installed. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the features geometry when the feature is included in the geodatabase. | |||
covertype | Cover Type | String | True | 0 | 0 | 20 | True | False | The type of surface above the buried pipe segment. | |||
depthunits | Depth Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure defining the original cover depth. | |||
diameterunits | Diameter Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure defining the nominal and outside diameters of the pipe. | |||
lengthunits | Length Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the measured length. | |||
pressureunits | Pressure Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the operating pressure. | |||
designpressureunits | Design Pressure Unit of Measure | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure defining the internal force specified as the design pressure. | |||
maopunits | MAOP Unit of Measure | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for defining the maximum allowable operating pressure. | |||
pipesurfaceareaunits | Pipe Surface Area Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for measuring the value in PIPESURFACEAREA. | |||
pipevolumeunits | Pipe Volume Units | Short Integer | True | 0 | 0 | 2 | True | False | The unit of measure for measuring the interior volume of the pipe segment. | |||
smys | SMYS | Double | True | 0 | 0 | 8 | True | False | The manufacturer-determined Specified Minimum Yield Strength value. | |||
percentsmys | Percent SMYS | Double | True | 0 | 0 | 8 | True | False | The percentage of the SMYS value under which the pipe segment pressure is operating. | |||
retireddate | Retired Date | Date | True | 0 | 0 | 8 | True | False | The date the pipe segment was permanently removed from production. | |||
stubbed | Stubbed | Short Integer | True | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the pipe segment has been stubbed. | |||
designpressureentered | Design Pressure Entered | Double | True | 0 | 0 | 8 | True | False | The internal force under which the pipe segment is designed to operate. | |||
designpressurestandard | Design Pressure Standard | Double | True | 0 | 0 | 8 | True | False | The average internal force under which the pipe segment is designed to operate. | |||
designfactor | Design Factor | Double | True | 0 | 0 | 8 | True | False | The margin of safety that was used during the design of the pipe segment when determining the design class. DOT regulations 192.103, 192.105, 192.107, and 192.111 require the use of class location design factors for steel pipes. | |||
wirematerial | Wire Material | String | True | 0 | 0 | 20 | True | False | The material used in the construction of the bond wire. | |||
servicesummaryid | Service Summary ID | GUID | True | 0 | 0 | 38 | True | False | The foreign key unique value used to relate the excess flow valve record to the SERVICESSUMMARY record class record with which it participates. | |||
workorderid | Work Order ID | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the task number under which the pipe segment was installed. | |||
projectnumber | Project Number | String | True | 0 | 0 | 38 | True | False | The work management system value used to identify the project number under which a work order was generated to install the pipe segment. | |||
legacyid | Legacy ID | String | True | 0 | 0 | 38 | True | False | A unique identifier used to relate this record to its predecessor record from a previous mapping or asset system. This provides continuity between the old system and the current Utility and Pipeline Data model. | |||
assetunitcode | Asset Unit Code | String | True | 0 | 0 | 38 | True | False | The foreign key value used to link this record to the utilities asset management system information for this pipe segment. | |||
eventid | Event ID | String | True | 0 | 0 | 38 | True | False | The unique ID for each pipe segment record. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the pipe segment became active on the route. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the pipe segment was retired from the route. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engfromm | Engineering From Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network engrouteid specified route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engfromm is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtorouteid | Engineering To Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtorouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtoroutename | Engineering To Route Name | String | True | 0 | 0 | 100 | True | False | The user-defined name of the engineering network route where the end of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtoroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engtom | Engineering To Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engrouteid or engtorouteid specified route where the completion of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engtom is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. | |||
continfromm | Continuous From Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network beginning measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
contintom | Continuous To Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network ending measure along the derived route ID. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
fromrefmethod | From Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset feature. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point feature class. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromreflocation | From Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting feature. This can be Coordinates, Feature/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
fromrefoffset | From Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefmethod | To Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset feature. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point feature class. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
toreflocation | To Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting feature. This can be Coordinates, Feature/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
torefoffset | To Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the Pipes features as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
bondedinsulated | Bonded/Insulated | Short Integer | True | Bonded_Insulated | 0 | 0 | 2 | True | False | Indicator of whether the pipe segment is Bonded or Insulated. Coded Value Domain: Bonded_Insulated | ||
cptraceability | Cathodic Protection Traceability | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | Indicator of whether the pipe segment participates in a cathodic protection zone. A code value of 2 (not traceable) is a barrier for the subnetwork cathodic protection zone. Coded Value Domain: CP_Traceability | ||
cpoverride | CP Override | Short Integer | True | CP_Traceability | 0 | 0 | 2 | True | False | Override of the default cptraceability Indicator of whether the pipe segment participates in a cathodic protection zone. Coded Value Domain: CP_Traceability | ||
locationdescription | Location Description | String | True | 0 | 0 | 255 | True | False | A description of the location of the record. | |||
centerlineid | Centerline ID | GUID | True | 0 | 0 | 38 | True | False | The system assigned value used for the ArcGIS Pipeline Referencing management of routes to pipeline features. | |||
milltestpressure | Mill Test Pressure | Double | True | 0 | 0 | 8 | True | False | The pressure to which the metallic pipe was tested at the manufacturer's facility. | |||
heatnumber | Heat Number | String | True | 0 | 0 | 38 | True | False | A unique value which defines where and when the steel used to manufacture the pipe was melted and formed into the steel pipe. | |||
jointnumber | Joint Number | String | True | 0 | 0 | 20 | True | False | A unique identifier used in the transmission pipeline construction process. | |||
validationstatus | Validation status | Short Integer | True | 6 | 0 | 0 | 2 | True | False | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_377_CPSubnet | False | True | CPSubnetworkName |
GDB_377_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_377_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_377_SystemSu | False | True | SystemSubnetworkName |
GDB_377_Pressure | False | True | PressureSubnetworkName |
GDB_377_Isolatio | False | True | IsolationSubnetworkName |
UUID_44 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__PipelineLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Service Pipe | 1 | The subtype feature layer Service Line describes the pipes that transport gas or liquid to the customer. Service Line is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, and removed). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Distribution Pipe | 2 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Transmission Pipe | 3 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Gathering Pipe | 4 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Station Pipe | 5 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Customer Pipe | 6 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Riser Pipe | 7 | The polyline derived layer Pipes describes the linear containers that transport liquid or gas. This feature class contains distribution, transmission, and gathering pipes. The attribute RegulatoryType is used to identify the system per regulation (Distribution, Transmission, Transmission Operated Distribution, Offshore Transmission, Gathering, or Offshore Gathering) with which the pipe segment is associated. Pipes is intended to be used for storing the representation of the physical pipe through all stages of its engineering life cycle (proposed, active, inactive, retired, removed, and abandoned). The asset types are configured to match the U.S. DOT annual reporting classifications of material type to simplify DOT compliance reporting. |
Storage Pipe | 8 | |
Pressure Sensor Pipe | 15 | |
Bonding Line | 50 | The subtype feature layer Bonding Line describes the wire that is used to continue the electrical connection in a cathodic protection system. Bonding Lines are used to span nonconductive assets such as plastic pipe segments. |
Test Lead Wire | 51 | The subtype feature layer Test Lead Wire describes the wire that is used to connect the test lead device to the cathodic protection system.. |
CP Cable | 52 | The subtype feature layer CP Rectifier Cable describes the cable that transmits electricity from the rectifier to the cathodic protection system. |
Linear Anode | 53 | |
AC Mitigation Wire | 54 |
ID | Minimum Client Version | Evaluation Order | Name | Description | Type | Batch | Insert Trigger | Update Trigger | Delete Trigger | Subtype | Field Name | Severity | Error Number | Error Message | Editable | Enabled | Exclude From Client | Tags | Creation Time | Category | Check Parameters | Script |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
13 | 12.1 | 1 | Line - Asset Type Material to Material Field | Calculate Material from Asset Type for Pipeline Line. Converts the Asset Type codes to Material codes. | Calculation | False | True | True | False | material | True | True | False | 2024-04-26 11:19:18 | // Assigned To: PipelineLine // Type: Calculation // Name: Line - Asset Type Material to Material Field // Description: Calculate Material from Asset Type for Pipeline Line. Converts the Asset Type codes to Material codes. // Subtypes: All // Field: material // Trigger: Insert, Update // Exclude From Client: False // Disable: False // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store Asset Type and Material // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.material; var asset_type = $feature.assettype; // Limit the rule to valid asset groups/subtypes // ** Implementation Note: Instead of recreating this rule for each subtype, this rules uses a list of subtypes and exits if not valid // If you have added Asset Groups, they will need to be added to this list. var valid_asset_groups = [1, 2, 3, 4, 5, 6, 7, 8, 15]; // Convert Asset Type to Material codes var at_to_mat = { '2': 'O', '11': '0', '12': 'R', '6': 'S', '4': 'X' }; // ************* End User Variables Section ************* if (!HasKey(at_to_mat, Text(asset_type))) { return assigned_to_field; } // Only when the field is null or set to unknown, set the value if (IsEmpty(assigned_to_field)) { return at_to_mat[Text(asset_type)]; } return assigned_to_field; | |||||||
14 | 12.7 | 2 | Line - Auto Contain By Rules | Auto contain pipeline lines. Uses the rule table to contain feature in a container within a search distance | Calculation | False | True | True | False | True | False | True | 2024-04-26 11:19:18 | // Assigned To: PipelineLine // Type: Calculation // Name: Line - Auto Contain By Rules // Description: Auto contain pipeline lines. Uses the rule table to contain feature in a container within a search distance // Subtypes: All // Trigger: Insert, Update // Exclude From Client: True // Disable: True // Implementation Note: This rule is disabled by default as it auto performs containment of features when editing. If you desire these functions, enable this rule and adjust the settings below. // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Auto Contain By Rules // - Junction - Auto Contain By Rules // - Line - Auto Contain By Rules // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // The subtype and asset type fields of $feature // ** Implementation Note: These fields are used to determine what Container associations are possible from the Rules table. var assetgroup = $feature.assetgroup var assettype = $feature.assettype // The association status field, this field is maintained by the utility network // ** Implementation Note: Do not change this value, it is in this section in case there is a schema change to the utility network in the future. var association_status = $feature.associationstatus; // The distance to search for a container // ** Implementation Note: Adjust this value based on the distance to auto contain, the comment after the value is an example how to use a // field to defined the distance, this field does not exist in the data model, but could be added to provide a data specific distance. var search_distance = 40; //DefaultValue($feature.searchdistance, 40); // The unit of the distance value in search_distance. // ** Implementation Note: Set the distance to search, for unit codes - https://desktop.arcgis.com/en/arcobjects/latest/net/webframe.htm#esriSRUnitType.htm var search_unit = 9002; // The utility network class ID for each layer. // ** Implementation Note: Adjust these values to match your geodatabase. The values defined below are for a Version 4 // utility network with only the schema provide(no additional domain networks) // These values will change with a version 3 utility network or if you applied more than one domain to the same utility network. // To review these values, open the attribute domains in the database with the utility network and search for FeatureSourceID. This domain // will list the class id by un domain alias, not class name, so you will have to related the un attribute domain to the gdb class name to match its ID function class_id_to_name(id) { return Decode(Text(id), "1", "Association", "2", "SystemJunction", "3", "SystemJunctionObject", "4", "StructureJunction", "5", "StructureLine", "6", "StructureBoundary", "7", "StructureJunctionObject", "8", "StructureEdgeObject", "9", "PipelineDevice", "10", "PipelineLine", "11", "PipelineAssembly", "12", "PipelineJunction", "13", "PipelineSubnetLine", "14", "PipelineJunctionObject", "15", "PipelineEdgeObject", null) } // monikerize FeatureSetByName function var get_features_switch_yard = FeatureSetByName; // A function to determine if the edit is triggered by UpdateSubnetwork. If a filegeodatbase, this action triggers an edit event, if enterprise, triggering the event is optional // ** Implementation Note: If using the industry model with all tiers, no change is required. If a tier was removed, remove the matching if block. function is_edit_from_subnetwork() { if ($feature.systemsubnetworkname != $originalfeature.systemsubnetworkname) { return true; } if ($feature.pressuresubnetworkname != $originalfeature.pressuresubnetworkname) { return true; } if ($feature.isolationsubnetworkname != $originalfeature.isolationsubnetworkname) { return true; } if ($feature.cpsubnetworkname != $originalfeature.cpsubnetworkname) { return true; } return false; } // ************* End User Variables Section ************ // ************* Functions ************* function geometry_change() { if (IsEmpty($originalfeature)) { return true; } if (IsEmpty(Geometry($originalfeature))) { return true; } return !Equals(Geometry($feature), Geometry($originalfeature)); } function sortCandidates(a, b) { if (a['distance'] < b['distance']) return -1; if (a['distance'] > b['distance']) return 1; return 0; } function build_containers_info() { var rule_fields = ['OBJECTID', 'RULETYPE', 'FROMNETWORKSOURCEID', 'FROMASSETGROUP', 'FROMASSETTYPE', 'TOASSETGROUP', 'TOASSETTYPE', 'GLOBALID'] var rules_fs = get_features_switch_yard($datastore, 'UN_6_Rules', rule_fields, false); var containers_rows = Filter(rules_fs, 'RULETYPE = 2 and TOASSETGROUP = @assetgroup and TOASSETTYPE = @assettype'); var container_row_count = Count(containers_rows) if (container_row_count == 0) { return null; } var container_class_types = {}; for (var container_row in containers_rows) { var class_name = class_id_to_name(container_row['FROMNETWORKSOURCEID']); if (IsEmpty(class_name)) { return {'errorMessage': 'Unable to translate Class ID to Class, attribute rules needs updating'}; } if (HasKey(container_class_types, class_name) == false) { container_class_types[class_name] = {}; } var asset_group = Text(container_row['FROMASSETGROUP']) if (HasKey(container_class_types[class_name], asset_group) == false) { container_class_types[class_name][asset_group] = []; } var asset_type = Text(container_row['FROMASSETTYPE']) if (IndexOf(container_class_types[class_name][asset_group], asset_type) == -1) { push(container_class_types[class_name][asset_group], asset_type) } } return container_class_types } function build_sql(container_info, feat_global_id) { var sql_class = []; var i = 0; for (var cls in container_info) { var sub_where = []; var k = 0; for (var ag in container_info[cls]) { sub_where[k++] = "(AssetGroup = " + ag + " AND AssetType IN (" + Concatenate(container_info[cls][ag], ',') + '))' } sql_class[i++] = [cls, '(' + Concatenate(sub_where, ' OR ') + ") and GLOBALID <> '" + feat_global_id + "'"]; } return sql_class } function generate_candidates(feature, sql_by_class, search_shape) { var container_candidate = []; var k = 0; for (var i = 0; i < Count(sql_by_class); i++) { var class_name = sql_by_class[i][0]; var where = sql_by_class[i][1]; var fs = get_features_switch_yard($datastore, class_name, ['GLOBALID'], false); var container_features = Filter(Intersects(fs, search_shape), where); var cont_feat_count = Count(container_features); if (cont_feat_count > 0) { for (var feat in container_features) { container_candidate[k++] = { 'class_name': class_name, 'globalid': feat.globalid, 'distance': Distance(feature, feat, 9002) } } } } return container_candidate; } // ************* End Functions Section ***************** // in FGDB, update subnetwork triggers an update operations, exit if (!($editContext.editType=='INSERT') && is_edit_from_subnetwork()) { return; } // If the geometry did not change on an update, return if (!($editContext.editType=='INSERT') && !geometry_change()) { return; } // If the feature is already content, return if ((association_status & 0x14) > 0) { return; } var container_info = build_containers_info(); if (IsEmpty(container_info)) { return; } if (TypeOf(container_info) == 'Dictionary') { if (HasKey(container_info, 'errorMessage')) { return container_info; } } var sql_by_class = build_sql(container_info, $feature.globalid); var search_shape = Buffer(Geometry($feature), search_distance, search_unit); var candidates = generate_candidates($feature, sql_by_class, search_shape) if (Count(candidates) == 0) { return; } var sorted_candidates = Sort(candidates, sortCandidates); var edit_payload = [{ 'className': sorted_candidates[0]['class_name'], 'updates': [{ 'globalID': sorted_candidates[0]['globalid'], 'associationType': 'container' }] }]; return {"edit": edit_payload}; | ||||||||
15 | 12.7 | 3 | Line - Cathodic Protection Traceability | Cathodic protection traceability for pipeline lines. Set traceability flag for lines assets | Calculation | False | True | True | False | cptraceability | True | True | False | 2024-04-26 11:19:18 | // Assigned To: PipelineLine // Type: Calculation // Name: Line - Cathodic Protection Traceability // Description: Cathodic protection traceability for pipeline lines. Set traceability flag for lines assets // Subtypes: All // Field: cptraceability // Trigger: Insert, Update // Exclude From Client: False // Disable: False // Is Editable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - Device - Cathodic Protection Traceability // - Junction - Cathodic Protection Traceability // - Line - Cathodic Protection Traceability // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the CP information // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.cptraceability; var cp_override = $feature.cpoverride; var cp_bondedinsulated = $feature.bondedinsulated; // Field in the data model used to store and manage the material details // ** Implementation Note: This value does not need to change if using the industry data model var cp_material = $feature.assettype; // The list of material types that are conductive from the assettype field and the asset type domains // ** Implementation Note: These do not need to be adjusted unless the value of the asset type attribute domains were changed. var conductive_materials = [1, 2, 3, 5, 6, 11, 12]; // The list of material types that are not conductive from the assettype field and the asset type domains // ** Implementation Note: These do not need to be adjusted unless the value of the asset type attribute domains were changed. var non_conductive_materials = [4, 7, 8, 9, 10]; // Limit the rule to valid asset groups/subtypes // ** Implementation Note: Instead of recreating this rule for each subtype, this rules uses a list of subtypes and exits if not valid // If you have added Asset Groups, they will need to be added to this list. var valid_asset_groups = [1, 2, 3, 4, 5, 6, 7, 8, 15, 50, 51, 52, 53, 54]; // List of asset groups that are always included in a CP trace. // ** Implementation Note: If you have extended the CP model for additional asset groups, those asset groups should be added here var asset_groups_always_traceability = [50, 51, 52, 53, 54]; // List of asset groups that are always not include in a CP trace and are CP barriers. // ** Implementation Note: If you have extended the pipe model for additional asset groups that never conduct cp current, those asset groups should be added here var asset_groups_never_traceability = []; // Values to determine traceability // ** Implementation Note: These do not need to be adjusted unless the value of the CP_Traceability attribute domain were changed. var traceable = 1; // Also used for Bonded var not_traceable = 2; // Also used for Insulated // ************* End User Variables Section ************* if (!Includes(valid_asset_groups, $feature.assetgroup)) { return assigned_to_field; } // If an override is specified, use that value regardless of other attributes if (cp_override > 0) { return cp_override; } // If a device is always traceability or not, regardless of material, return the proper status if (Includes(asset_groups_always_traceability, $feature.assetgroup)) { return traceable; } if (Includes(asset_groups_never_traceability, $feature.assetgroup)) { return not_traceable; } // If a value is set on the bonded, insulated field, return that value if (!IsEmpty(cp_bondedinsulated) && cp_bondedinsulated > 0) { return cp_bondedinsulated; } // Check if the material is conductive if (Includes(conductive_materials, cp_material)) { return traceable; } if (Includes(non_conductive_materials, cp_material)) { return not_traceable; } //Return the value in the field when no other condition is met return assigned_to_field; | |||||||
16 | 12.6 | 4 | PipelineLine-GenerateIDs | Generate IDs for PipelineLine using database sequences | Calculation | False | True | True | False | assetid | True | True | True | 2024-04-26 11:19:18 | // Assigned To: PipelineLine // Type: Calculation // Name: PipelineLine-GenerateIDs // Description: Generate IDs for PipelineLine using database sequences // Subtypes: All // Field: assetid // Trigger: Insert, Update // Exclude From Client: True // Disable: False // Related Rules: Some rules are rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated In: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - StructureJunction-GenerateIDs // - StructureBoundary-GenerateIDs // - StructureLine-GenerateIDs // - PipelineDevice-GenerateIDs // - PipelineAssembly-GenerateIDs // - PipelineJunction-GenerateIDs // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Field in the data model used to store and manage the ID // ** Implementation Note: This value does not need to change if using the industry data model var assigned_to_field = $feature.assetid; // Asset group/Subtype field used to define different IDs per the class // ** Implementation Note: This value does not need to change if using the industry data model var id_selector_value = $feature.assetgroup; // Define the leading text, the trailing text and the delimiter for the ID, this function requires the keyed passed in // NextSequenceValue requires a string literal for copy and paste, although it supports a variable, it is recommended // to not use one // ** Implementation Note: Adjust the prefix and join_char for each subtype. The selector_value_txt is the subtype of the layer function get_id(selector_value) { var id_format = {} var seq_val = null; var selector_value_txt = Text(selector_value) if (selector_value_txt == '1') { id_format = { 'prefix': "SVC-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_SVC_Pp_1_seq'); }else if (selector_value_txt == '2') { id_format = { 'prefix': "Dstrbtn-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Dstrbtn_Pp_2_seq'); }else if (selector_value_txt == '3') { id_format = { 'prefix': "Trnsmssn-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Trnsmssn_Pp_3_seq'); }else if (selector_value_txt == '4') { id_format = { 'prefix': "Gthrng-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Gthrng_Pp_4_seq'); }else if (selector_value_txt == '5') { id_format = { 'prefix': "Sttn-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Sttn_Pp_5_seq'); }else if (selector_value_txt == '6') { id_format = { 'prefix': "Cstmr-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Cstmr_Pp_6_seq'); }else if (selector_value_txt == '7') { id_format = { 'prefix': "Rsr-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Rsr_Pp_7_seq'); }else if (selector_value_txt == '8') { id_format = { 'prefix': "Strg-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Strg_Pp_8_seq'); }else if (selector_value_txt == '15') { id_format = { 'prefix': "Prssr-Snsr-Pp", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Prssr_Snsr_Pp_15_seq'); }else if (selector_value_txt == '50') { id_format = { 'prefix': "Bndng-Ln", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Bndng_Ln_50_seq'); }else if (selector_value_txt == '51') { id_format = { 'prefix': "Tst-Ld-Wr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Tst_Ld_Wr_51_seq'); }else if (selector_value_txt == '52') { id_format = { 'prefix': "CP-Cbl", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_CP_Cbl_52_seq'); }else if (selector_value_txt == '53') { id_format = { 'prefix': "Lnr-And", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_Lnr_And_53_seq'); }else if (selector_value_txt == '54') { id_format = { 'prefix': "AC-Mtgtn-Wr", 'join_char': '-', 'suffix': '' } seq_val = NextSequenceValue('P_L_AC_Mtgtn_Wr_54_seq'); } else { return null; } var id_parts = remove_empty([id_format['prefix'], seq_val, id_format['suffix']]) return Concatenate(id_parts, id_format['join_char']) } // ************* End User Variables Section ************* // ************* Functions ************* function remove_empty(arr) { var new_arr = []; var j = 0; for (var i = 0; i < Count(arr); i++) { if (!IsEmpty(arr[i]) && arr[i] != '') { new_arr[j++] = arr[i]; } } return new_arr; } // ************* End Functions Section ***************** if ($editcontext.editType == 'UPDATE'){ if (IsEmpty(assigned_to_field) == false) { return assigned_to_field } } var new_id = get_id(id_selector_value) if (IsEmpty(new_id)) { return assigned_to_field; } return new_id | |||||||
17 | 12.7 | 1 | PipelineLine - Constrain Contingent Values | Constrain attributes on all PipelineLine features with Contingent Values applied. | Constraint | False | True | True | False | 5002 | Error | True | True | 2024-04-26 11:19:18 | // Assigned To: PipelineLine // Type: Constraint // Name: PipelineLine - Constrain Contingent Values // Description: Constrain attributes on all PipelineLine features with Contingent Values applied. // Subtypes: All // Error Number: 5002 // Error Message: Error // Exclude From Client: True // Disable: False // Trigger: Insert, Update // Related Rules: Some rules rely on additional rules for execution. If this rule works in conjunction with another, they are listed below: // - None // Duplicated in: This rule may be implemented on other classes, they are listed here to aid you in adjusting those rules when a code change is required. // - None // ************* User Variables ************* // This section has the functions and variables that need to be adjusted based on your implementation // Limit the rule to specific asset groups on $feature. For non-subtyped layers, a value of zero will be used. // ** Implementation Note: This rule uses a list of subtypes and exits if not valid. Add to list to limit rule to specific asset groups. var assetgroup = $feature.ASSETGROUP; var valid_asset_groups = [1, 2, 3, 4, 5, 6, 7, 8, 15]; // Customize error message for contingent value violations var cav_violation_message = 'Attributes do not satisfy the Contingent Value Field Group'; // Declare all fields that participate in a Contingent Value to ensure ArcGIS validation works var ASSETTYPE = $feature.ASSETTYPE; var material = $feature.material; // Lookup for checking field attribute value combinations // ** Implementation Note: This is a JSON structure used to quickly check that attributes satisfy all required Contingent Values. var cv_lookup = [{'field_group': 'Limit Material By Asset Type', 'fields': ['ASSETTYPE', 'material'], 'retired': {}, 'subtypes': {'1': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '10': ['J', '__null__', 'UN', 'X'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '5': ['X', '__null__', 'UN'], '6': ['S', '__null__', 'UN', 'X'], '7': ['__null__', 'X', 'UN'], '8': ['__null__', 'UN', 'X'], '9': ['A', 'B', 'C', 'D', 'E', 'F', 'G', 'H', 'UN', '__null__', 'X']}, '15': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '6': ['S', '__null__', 'UN', 'X']}, '2': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '10': ['J', '__null__', 'UN', 'X'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '5': ['X', '__null__', 'UN'], '6': ['S', '__null__', 'UN', 'X'], '7': ['__null__', 'X', 'UN'], '8': ['__null__', 'UN', 'X'], '9': ['A', 'B', 'C', 'D', 'E', 'F', 'G', 'H', 'UN', '__null__', 'X']}, '3': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '6': ['S', '__null__', 'UN', 'X']}, '4': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '10': ['J', '__null__', 'UN', 'X'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '6': ['S', '__null__', 'UN', 'X'], '7': ['__null__', 'X', 'UN'], '8': ['__null__', 'UN', 'X'], '9': ['A', 'B', 'C', 'D', 'E', 'F', 'G', 'H', 'UN', '__null__', 'X']}, '5': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '6': ['S', '__null__', 'UN', 'X']}, '6': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '10': ['J', '__null__', 'UN', 'X'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '6': ['S', '__null__', 'UN', 'X'], '7': ['__null__', 'X', 'UN'], '8': ['__null__', 'UN', 'X'], '9': ['A', 'B', 'C', 'D', 'E', 'F', 'G', 'H', 'UN', '__null__', 'X']}, '7': {'0': ['UN', '__null__'], '1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['__null__', 'UN', 'X'], '6': ['S', '__null__', 'UN', 'X']}, '8': {'1': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '10': ['J', '__null__', 'UN', 'X'], '11': ['__null__', 'O', 'UN', 'X'], '12': ['R', '__null__', 'UN', 'X'], '2': ['__null__', 'UN', 'O', 'X'], '3': ['UN', '0', '1', '2', '3', '4', '5', '6', '7', '8', '9', 'M', 'N', 'X', '__null__'], '4': ['T', 'U', '__null__', 'UN', 'X', 'V'], '5': ['X', '__null__', 'UN'], '6': ['S', '__null__', 'UN', 'X'], '7': ['__null__', 'X', 'UN'], '8': ['__null__', 'UN', 'X'], '9': ['A', 'B', 'C', 'D', 'E', 'F', 'G', 'H', 'UN', '__null__', 'X']}}}] // ************* End User Variables Section ************* // ************* Functions ************* function get(d, key) { // retrieve value from dict // - if dict has 'ANY' key, return value // - if key does not exist return null if (IsEmpty(d)) return null; if (!HasKey(d, key)) { if (HasKey(d, 'ANY')) { return d['ANY']; } // no valid matches found return null; } return d[key] } function is_range(d) { // determine if keys in a dict are range keys. if first key is a range, all of them are. for (var k in d) { return Find('#', k) > -1 } } function in_range(val, range) { // Check if val is within range // Args: // range (str): string representation of a range with '#' as separator // val (str): value to check if within range var values = Split(range, '#', 2) val = Number(val) return Number(values[0]) <= val && val <= Number(values[1]) } function in_array_of_ranges(list, val) { // check if val is in contained in any ranges in list var valid_range = null; for (var idx in list) { if (in_range(val, list[idx])) { valid_range = true break } } return valid_range } function drill_down(d, values) { // check if valid combo of values exists in lookup // Args: // d (dict): lookup of possible CAV combinations // values (array): an array of values. first value is subtype and remaining are attributes in a certain order if (Text(d) == '{}') return null; if (TypeOf(d) == "Dictionary" && is_range(d)) { // we need to check every range key possible (with all downstream values) for (var k in d) { if (in_range(values[0], k)) { var ret = drill_down(d[k], Slice(values, 1)); if (IsEmpty(ret)) { continue } else {return ret} } } // no valid combos found return null; } else if (TypeOf(d) == "Array") { // check for value in array or in any range in array if (Includes(d, values[-1]) || Includes(d, 'ANY')) { return true; } else if (Find('#', d[0]) > -1) { return in_array_of_ranges(d, values[-1]) } else {return null} } else { var ret = get(d, Text(values[0])); ret = drill_down(ret, Slice(values, 1)) // need check the 'ANY' key as well if (IsEmpty(ret) && HasKey(d, 'ANY')) { ret = get(d, 'ANY') ret = drill_down(ret, Slice(values, 1)) } return ret } } // ************* End Functions Section ****************** // Limit the rule to valid subtypes if (!Includes(valid_asset_groups, assetgroup)) { return true; } var error_mess = ''; for (var idx in cv_lookup) { var field_group = cv_lookup[idx]; // if subtype is not in field group, skip to next field group if (!HasKey(field_group["subtypes"], Text(assetgroup))) { continue } var values_list = []; push(values_list, Text(assetgroup)); for (var idx2 in field_group['fields']) { var field = field_group['fields'][idx2]; push(values_list, iif($feature[field]==null, '__null__', Text($feature[field]))) } // check if values_list combo exists in contingent value lookup var ret = drill_down(field_group["subtypes"], values_list); if (IsEmpty(ret)) { // check for retired if (!IsEmpty(drill_down(field_group["retired"], values_list))) { continue } else { error_mess += `${cav_violation_message} - ${field_group["field_group"]}. `; } } } if (IsEmpty(error_mess)) { return true; } else { return {'errorMessage': error_mess} } |
Key | Value |
---|---|
Name | main.P_AnomalyGroup |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 414 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Anomaly Group |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {FBDBFB5F-3098-4D2E-B72C-EE4A72A23F96} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_AnomalyGroup represents a set of anomalies in the pipeline system as detected from inline inspection runs of a pigging device. The record contains mean (average) values for a set of anomaly point features. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 15 | True | False | The text value indicating the life cycle state of the object. Valid values are conceptual, proposed, active, inactive, and unknown. | ||
bprcalculatedaverage | Average BPR Calculated | Double | True | 0 | 0 | 8 | True | False | The mean back pressure ratio calculated for a set of anomaly point features. | |||
bprpigaverage | BPR Pig Average | Double | True | 0 | 0 | 8 | True | False | The mean back pressure ratio for a set of anomaly point features recorded by an inline pig run. | |||
bprvarianceaverage | BPR Pig Average | Double | True | 0 | 0 | 8 | True | False | The mean variance between calculated back pressure ratio and pig back pressure ratio for a set of anomaly point features recorded by an inline pig run. | |||
depthaverage | Average Depth | Double | True | 0 | 0 | 8 | True | False | The mean depth for a set of anomaly point features from ground surface. | |||
lengthaverage | Average Length | Double | True | 0 | 0 | 8 | True | False | The mean length of a set of anomaly point features. | |||
widthaverage | Average Width | Double | True | 0 | 0 | 8 | True | False | The mean width of a set of anomaly point features. | |||
maxdiameteraverage | Average Max Diameter | Double | True | 0 | 0 | 8 | True | False | The mean maximum diameter of the pipe segment at a set of anomaly point features. | |||
mindiameteraverage | Average Min Diameter | Double | True | 0 | 0 | 8 | True | False | The mean minimum diameter of the pipe segment at a set of anomaly point features. | |||
orientationaverage | Average Orientation | String | True | 0 | 0 | 5 | True | False | The mean angular position of a set of anomaly point features on a pipe cross section. | |||
rprcalculatedaverage | Average Calculated RPR | Double | True | 0 | 0 | 8 | True | False | The calculated mean rupture pressure ratio for a set of anomaly point features. | |||
rprpigdaverage | Average Pig RPR | Double | True | 0 | 0 | 8 | True | False | The calculated mean rupture pressure ratio for a set of anomaly point features. | |||
rprvarianceaverage | Average Variance RPR | Double | True | 0 | 0 | 8 | True | False | The mean variance between calculated rupture pressure ratios and pig rupture pressure ratios recorded for a set of anomaly point features. | |||
inspectionrange_globalid | InspectionRange GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The foreign key value used to relate an anomaly group record to the related inspection range. | ||
eventid | EventID | String | True | 0 | 0 | 38 | True | False | The unique ID for each record. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
engrouteid | Engineering Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engrouteid is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engroutename | Engineering Route Name | String | True | 0 | 0 | 255 | True | False | The user-defined name of the engineering network route where the beginning of the linear event is located. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. engroutename is not required if modeling in ArcGIS Pipeline Referencing (APR) as continuous networks. | |||
engm | Engineering Measure | Double | True | 0 | 0 | 8 | True | False | The measure location along the engineering network route where the record is located. This attribute is only used by organizations wanting to maintain the junction records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
continrouteid | Continuous Route ID | String | True | 0 | 0 | 38 | True | False | The continuous network route ID that is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. | |||
continroutename | Continuous Route Name | String | True | 0 | 0 | 100 | True | False | The continuous network name where the point event is located. This event route name is automatically created and maintained by the ArcGIS Pipeline Referencing tools. This attribute is only used by organizations wanting to maintain the features as event records with the ArcGIS Pipeline Referencing tools. | |||
continm | Continuous Measure | Double | True | 0 | 0 | 8 | True | False | The continuous network measure along the continrouteid route. This value is automatically created and maintained by the ArcGIS Pipeline Referencing tools. | |||
refmethod | Reference Method | Short Integer | True | 0 | 0 | 2 | True | False | The method of referencing the offset record. This can be Coordinates, Stationing, Length, LRS Network, Event Intersection, or other point record class. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
refoffset | Reference Offset | String | True | 0 | 0 | 50 | True | False | The offset measure. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
reflocation | Reference Location | String | True | 0 | 0 | 50 | True | False | The location of the offsetting record. This can be Coordinates, record/EventID, and/or IntersectionID. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is populated by the ArcGIS Pipeline Referencing tools. | |||
locationerror | Location Error | String | True | 0 | 0 | 100 | True | False | The resultant message from the process of defining the event's location on a route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_414_INSPECTI | False | True | inspectionrange_globalid |
UUID_81 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_AnomalyGroup_shape | True | True | shape |
Key | Value |
---|---|
Name | main.StructureJunctionObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 39 |
Minimum Client Version | 13.2 |
Alias | Structure Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {B5B6C5FE-4A86-4960-A6E2-19C17D6F6FFE} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | |||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | ||
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | |||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | ||
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_39_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_41 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name |
---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus |
Unknown | 0 | SUBNETWORKNAME | Unknown |
Key | Value |
---|---|
Name | main.StructureEdgeObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 40 |
Minimum Client Version | 13.2 |
Alias | Structure Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {572B9DB7-C669-4BF7-A080-15EE75C62522} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | |||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | ||
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | |||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | ||
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_40_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_42 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name |
---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus |
Unknown | 0 | SUBNETWORKNAME | Unknown | |
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection |
Key | Value |
---|---|
Name | main.PipelineJunctionObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 381 |
Minimum Client Version | 13.2 |
Alias | Pipeline Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {1DAF57D8-C030-4B7F-B454-1FDFA1B38C5E} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | |||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | ||
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | |||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | ||
ISSUBNETWORKCONTROLLER | Is subnetwork controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | ||
ISCONNECTED | Is connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
SUBNETWORKCONTROLLERNAME | Subnetwork controller name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
TIERNAME | Tier name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | ||
TIERRANK | Tier rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | |||
TERMINALCONFIGURATION | Terminal path | String | False | Default | 0 | 0 | 128 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
CPSubnetworkName | CPSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SystemSubnetworkName | SystemSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
PressureSubnetworkName | PressureSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
IsolationSubnetworkName | IsolationSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_381_Isolatio | False | True | IsolationSubnetworkName |
GDB_381_Pressure | False | True | PressureSubnetworkName |
GDB_381_SystemSu | False | True | SystemSubnetworkName |
GDB_381_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_381_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_381_CPSubnet | False | True | CPSubnetworkName |
GDB_381_SUBNETWO | False | True | SUBNETWORKCONTROLLERNAME |
UUID_48 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name |
---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus |
Unknown | 0 | ISSUBNETWORKCONTROLLER | 0 | Network_6_IsSubnetworkController |
Unknown | 0 | ISCONNECTED | 2 | Network_6_IsConnected |
Unknown | 0 | SUBNETWORKCONTROLLERNAME | Unknown | |
Unknown | 0 | TIERNAME | 0 | Network_6_TierName |
Unknown | 0 | TIERRANK | 0 | |
Unknown | 0 | TERMINALCONFIGURATION | Default | |
Unknown | 0 | CPSubnetworkName | Unknown | |
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | |
Unknown | 0 | SUPPORTINGSUBNETWORKNAME | Unknown | |
Unknown | 0 | SystemSubnetworkName | Unknown | |
Unknown | 0 | PressureSubnetworkName | Unknown | |
Unknown | 0 | IsolationSubnetworkName | Unknown |
Key | Value |
---|---|
Name | main.PipelineEdgeObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 382 |
Minimum Client Version | 13.2 |
Alias | Pipeline Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {8FF31DD5-E9BC-49F7-B0D2-2111BD533650} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | Object ID | OID | Index | False | 0 | 0 | 8 | False | True | |||
ASSETGROUP | Asset group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | ||
ASSETTYPE | Asset type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | |||
ASSOCIATIONSTATUS | Association status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | ||
ISCONNECTED | Is connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
CPSubnetworkName | CPSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SystemSubnetworkName | SystemSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
PressureSubnetworkName | PressureSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
IsolationSubnetworkName | IsolationSubnetworkName | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_382_Isolatio | False | True | IsolationSubnetworkName |
GDB_382_Pressure | False | True | PressureSubnetworkName |
GDB_382_SystemSu | False | True | SystemSubnetworkName |
GDB_382_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_382_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_382_CPSubnet | False | True | CPSubnetworkName |
UUID_49 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name |
---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus |
Unknown | 0 | ISCONNECTED | 2 | Network_6_IsConnected |
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection |
Unknown | 0 | CPSubnetworkName | Unknown | |
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | |
Unknown | 0 | SUPPORTINGSUBNETWORKNAME | Unknown | |
Unknown | 0 | SystemSubnetworkName | Unknown | |
Unknown | 0 | PressureSubnetworkName | Unknown | |
Unknown | 0 | IsolationSubnetworkName | Unknown |
Key | Value |
---|---|
Name | main.P_CPBondInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 383 |
Minimum Client Version | 10.1 |
Alias | CP Bond Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {5479CD80-97C7-4BAD-8568-9B1A4169ACA2} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_CPBondInspection contains the results of the inspection of cathodic protection bonds. This record contains the measurements obtained at interference bond locations. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
bondedpson | Bonded PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement while bonded to the foreign structure. | |||
disbondedpson | Disbonded PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement while not bonded to the foreign structure. | |||
foreignstructuredisbondedpson | Foreign Structure Disbonded PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading from the foreign structure for the pipe-to-soil on measurement while not bonded. | |||
dcamps | DC Amps | Double | True | 0 | 0 | 8 | True | False | The amperage reading taken at the interference bond. | |||
instrument | Instrument | String | True | 0 | 0 | 30 | True | False | The instrument used to acquire the measurements. | |||
maintenancerequired | Maintenance Required | String | True | 0 | 0 | 255 | True | False | The description of any follow-up maintenance activities required at this interference bond. | |||
maintenanceperformed | Maintenance Performed | String | True | 0 | 0 | 255 | True | False | The description of any maintenance actions taken by the field technician during the read process. | |||
updmjunction_globalid | UPDMJunction GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMJunction feature class, subtype Bond Junction globalid value of the record with which the field measurement is associated. | ||
updmline_globalid | UPDMLine GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMLine feature class, subtype Bond Wire globalid value of the record with which the field measurement is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_383_UPDMLine | False | True | updmline_globalid |
GDB_383_UPDMJunc | False | True | updmjunction_globalid |
UUID_50 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_CPRectifierInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 384 |
Minimum Client Version | 10.1 |
Alias | CP Rectifier Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {A5F27373-1FA0-438C-90B1-97B9FAD5E9EF} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_CPRectifierInspection contains the results of the inspection of a cathodic protection rectifier. Regulations require that each rectifier be inspected periodically to ensure it is operating properly. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
pson | PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement. | |||
psoff | PS Off | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil off measurement. | |||
dcvoltagefound | DC Voltage Found | Double | True | 0 | 0 | 8 | True | False | The DC voltage reading of the rectifier as initially found at the device. | |||
dcampsfound | DC Amps Found | Double | True | 0 | 0 | 8 | True | False | The DC amperage reading of the rectifier as initially found at the device. | |||
statusasfound | On Off Status | String | True | Pipeline_On_Off_Status | 0 | 0 | 5 | True | False | The operating status of the rectifier as initially found by the field technician at the device. | ||
dcvoltageleft | DC Voltage Left | Double | True | 0 | 0 | 8 | True | False | The DC voltage reading of the rectifier as left by the field technician at the device. | |||
dcampsleft | DC Amperage Left | Double | True | 0 | 0 | 8 | True | False | The DC amperage reading of the rectifier as left by the field technician at the device. | |||
statusasleft | Status as Left | String | True | Pipeline_On_Off_Status | 0 | 0 | 5 | True | False | The operating status of the rectifier as left by the technician at the device. | ||
taptype | Tap Type | String | True | 0 | 0 | 15 | True | False | The type of tap used in the rural tap. | |||
tapsetting | Tap Setting | String | True | 0 | 0 | 15 | True | False | The current tap position setting of the rectifier. | |||
instrument | Instrument | String | True | 0 | 0 | 30 | True | False | The instrument used to acquire the measurements. | |||
maintenancerequired | Maintenance Required | String | True | 0 | 0 | 255 | True | False | The description of any follow-up maintenance activities required at this rectifier. | |||
maintenanceperformed | Maintenance Performed | String | True | 0 | 0 | 255 | True | False | The description of any maintenance actions taken by the field technician during the read process. | |||
updmdevice_globalid | UPDMDevice GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMDevice feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_384_UPDMDevi | False | True | updmdevice_globalid |
UUID_51 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_CPTestPointReading |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 385 |
Minimum Client Version | 10.1 |
Alias | CP Test Point Reading |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {7D69BD7F-5928-4FF1-AFF3-37530350C6A4} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_CPTestPointReading represents the set of electrical field measurements and other information collected at a specific test point location along the pipeline. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
pson | PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement. | |||
psoff | PS Off | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil off measurement. | |||
soilresistivity | Soil Resistivity | Double | True | 0 | 0 | 8 | True | False | The resistivity of the soil measured in ohm-centimeter. | |||
shorted | Shorted | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether there is an electrical short at the test station. | ||
instrument | Instrument | String | True | 0 | 0 | 30 | True | False | The instrument used to acquire the measurements. | |||
reasonforfailurereading | Reason For Failed Reading | String | True | 0 | 0 | 30 | True | False | The field technician stated reason for the test point reading giving a value outside the acceptable range. | |||
correctiveactiontaken | Corrective Action Taken | String | True | 0 | 0 | 30 | True | False | If applicable, the corrective or repair action taken by the field technician to restore the cathodic protection. | |||
maintenancerequired | Maintenance Required | String | True | 0 | 0 | 255 | True | False | The description of any follow-up maintenance activities required at this test station. | |||
maintenanceperformed | Maintenance Performed | String | True | 0 | 0 | 255 | True | False | The description of any maintenance actions taken by the field technician during the read process. | |||
updmdevice_globalid | CPRectifier GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMDevice feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_385_UPDMDevi | False | True | updmdevice_globalid |
UUID_52 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_CasingInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 386 |
Minimum Client Version | 10.1 |
Alias | Casing Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {8A58D4A1-2E6B-443B-9743-CEA6DB440F61} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_CasingInspection contains the results of cathodic inspections of metallic gas pipe casings. Metallic casings carrying gas pipes are also subject to corrosion and can participate in a cathodic protection system. A casing inspection represents the set of electrical field measurements and other information collected on the casing as well as on the gas pipe inside the casing. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
daterecorded | Date Recorded | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
carrierpipepson | Carrier Pipe PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement for the gas pipe inside the casing. | |||
carrierpipepsoff | Carrier Pipe PS Off | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil off measurement for the gas pipe inside the casing. | |||
casingpipepson | Casing Pipe PS On | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement for the gas pipe casing. | |||
casingpipepsoff | Casing Pipe PS Off | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil off measurement for the gas pipe casing. | |||
shorted | Shorted | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether there was an electrical short. | |
instrument | Instrument | String | True | 0 | 0 | 30 | True | False | The instrument used to acquire the measurements. | |||
maintenancerequired | Maintenance Required | String | True | 0 | 0 | 255 | True | False | The description of any follow-up maintenance activities required at this casing. | |||
maintenanceperformed | Maintenance Performed | String | True | 0 | 0 | 255 | True | False | The description of any maintenance actions taken by the field technician during the read process. | |||
structureline_globalid | Structure Line GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The structureline feature class globalid value of the record with which the field measurement is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_386_STRUCTUR | False | True | structureline_globalid |
UUID_53 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_Centerline_Sequence |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 387 |
Minimum Client Version | 10.1 |
Alias | Centerline Sequence |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {A362813C-971E-4B2E-A359-C8C2DC9437D7} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_Centerline_Sequence is a cross-reference table to define the many-to-many relationship between centerlines and routes. One centerline feature can participate in many routes and a route is typically made up of more than one centerlines. This table is only required if the ArcGIS Linear Referencing for Pipeline Tools are being utilized. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
fromdate | From Date | Date | True | 0 | 0 | 8 | True | False | The date the record became active on the route. This attribute is only used by organizations wanting to maintain the Pipes records as event records with the ArcGIS Pipeline Referencing tools. This value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
todate | To Date | Date | True | 0 | 0 | 8 | True | False | The date the record was retired from the route. This attribute is only used by organizations wanting to maintain the records as event records with the ArcGIS Pipeline Referencing tools. The value is automatically generated and populated by the ArcGIS Pipeline Referencing tools. | |||
routeid | Route ID | String | True | 0 | 0 | 38 | True | False | The unique ID for the route. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
centerlineid | CenterLineIDGUID | GUID | True | 0 | 0 | 38 | True | False | The unique ID for the centerline geometry. This value is assigned by the ArcGIS Pipeline Referencing tools. | |||
networkid | NetworkID | Short Integer | True | 0 | 0 | 2 | True | False | The unique ID for the ALRP network in which each route participates. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | globalid | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_54 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_CrossingInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 388 |
Minimum Client Version | 10.1 |
Alias | Crossing Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {30CCA3E5-1C39-4D61-91E7-534730E4915E} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The inspection performed at the locations identified by the features in the LineCrossing feature class. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
lastinspectiondate | Last Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date the last inspection was performed. | |||
nextinspectiondate | Next Inspection Date | Date | True | 0 | 0 | 8 | True | False | The date the next inspection is due to be performed. | |||
locationdescription | Location Description | String | True | 0 | 0 | 150 | True | False | A description of the location of the record. | |||
notes | Notes | String | True | 0 | 0 | 255 | True | False | Additional information about the record. | |||
pipecrossing_globalid | Pipe Crossing GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The PipeCrossing feature class globalid value of the record with which the field measurement is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_388_PIPECROS | False | True | pipecrossing_globalid |
UUID_55 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_DocumentPoint__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 389 |
Minimum Client Version | 10.1 |
Alias | P_DocumentPoint__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {917A2C92-3807-407F-9CE2-B8B1E9AA5F8A} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_389_REL_GLOB | False | True | rel_globalid |
UUID_56 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_ElectricSurvey |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 390 |
Minimum Client Version | 10.1 |
Alias | Electric Survey |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {4CB50AA9-956C-408A-9532-49B3BD5C50BA} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The inspection performed on above ground metallic pipes to monitor rate of corrosion. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
surveydate | Survey Date | Date | True | 0 | 0 | 8 | True | False | The date the survey what performed. | |||
surveyduedate | Survey Due Date | Date | True | 0 | 0 | 8 | True | False | The date the next survey is due to be performed. | |||
surveyfrequency | Survey Frequency | Short Integer | True | 0 | 0 | 2 | True | False | The frequency at which surveys are performed. | |||
voltage | Voltage | Double | True | 0 | 0 | 8 | True | False | The measured voltage. | |||
amperage | Amperage | Double | True | 0 | 0 | 8 | True | False | The measure of the electrical current generated by the rectifier. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_57 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_ExcavationDamage__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 391 |
Minimum Client Version | 10.1 |
Alias | P_ExcavationDamage__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {50CFE073-35D8-44B0-884F-3D4EFF9238E3} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_391_REL_GLOB | False | True | rel_globalid |
UUID_58 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_ExposedPipeInspect__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 392 |
Minimum Client Version | 10.1 |
Alias | P_ExposedPipeInspect__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {C5F54832-ED9B-45DB-822D-835C38C8938A} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_392_REL_GLOB | False | True | rel_globalid |
UUID_59 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_GasLeakInspect |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 393 |
Minimum Client Version | 10.1 |
Alias | Gas Leak Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {063B57C4-083F-4B99-BEC3-54ADC81F4734} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_GasLeakInspection describes a Class 2 or Class 3 leak that may be inspected multiple times over the life of the leak. For full audit capabilities, each leak inspection must be stored. This is a field data collection activity commonly performed by a gas utilitys operations staff. The field leak inspection investigation process will result is a remeasurement of the amount of gas escaping from the gas system. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
surfacetype | Surface Type | String | True | Pipeline_Surface_Type | 0 | 0 | 20 | True | False | The type of surface covering the identified gas leak location. | ||
gasin | Gas In | String | True | Pipeline_Leak_Inspect_Gas_In | 0 | 0 | 25 | True | False | The categorical description of where the gas leak is located. | ||
probablesource | Facility | String | True | Pipeline_Leak_Facility_Type | 0 | 0 | 25 | True | False | The field technicians determination of the most likely pipe system asset source of the gas leak. | ||
leakclass | Original Leak Class | Short Integer | True | Pipeline_Leak_Class | 0 | 0 | 2 | True | False | The DOT classification of the type of gas leak. | ||
methoddetected | Method Detected | String | True | Pipeline_Leak_Method_Detected | 0 | 0 | 20 | True | False | The method used by the gas field technician to identify the location and concentration of leaking gas. | ||
gasmeasurement | Gas Measurement | Double | True | 0 | 0 | 8 | True | False | The highest concentration of methane gas recorded by the gas field technician while performing the leak inspection. | |||
gasmeasurementunits | Gas Measurement Units | Short Integer | True | Pipeline_Measurement_Units | 0 | 0 | 2 | True | False | The unit of measure used to determine the amount of natural gas escaping from the leak. | ||
comments | Comments | String | True | 0 | 0 | 255 | True | False | Any additional comments the gas field technician provides about the reported leak. | |||
gasleak_globalid | GasLeak GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The GasLeak feature class globalid value of the leak feature that was inspected. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_393_GASLEAK_ | False | True | gasleak_globalid |
UUID_60 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_GasLeakInspect__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 394 |
Minimum Client Version | 10.1 |
Alias | P_GasLeakInspect__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {07196C4C-8B82-4CE9-BA94-32614F09DD0B} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_394_REL_GLOB | False | True | rel_globalid |
UUID_61 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_GasLeak__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 395 |
Minimum Client Version | 10.1 |
Alias | P_GasLeak__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {42389818-5219-43E2-A9C1-929AE7A5F45B} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_395_REL_GLOB | False | True | rel_globalid |
UUID_62 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_IdentifiedIssue__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 396 |
Minimum Client Version | 10.1 |
Alias | P_IdentifiedIssue__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {52D3E42D-D244-4DA7-813A-99B4B03E29D5} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_396_REL_GLOB | False | True | rel_globalid |
UUID_63 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_IsolatedPipeInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 397 |
Minimum Client Version | 10.1 |
Alias | Isolated Pipe Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {0FEBC1BA-4547-444E-8D3E-AEE7AF93D63D} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_IsolatedPipeInspection contains the inspections of isolated cathodically protected sections of pipe. This record contains the measurements obtained for separately protected, short sections of mains or services. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
pson | PSON | Double | True | 0 | 0 | 8 | True | False | The voltage reading for the pipe-to-soil on measurement. | |||
shorted | Shorted | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether there is an electrical short at the test station. | |
instrument | Instrument | String | True | 0 | 0 | 50 | True | False | The instrument used to acquire the measurements. | |||
maintenancerequired | Maintenance Required | String | True | 0 | 0 | 255 | True | False | The description of any follow-up maintenance activities required at this interference bond. | |||
maintenanceperformed | Maintenance Performed | String | True | 0 | 0 | 255 | True | False | The description of any maintenance actions taken by the field technician during the read process. | |||
updmline_globalid | UPDMLine GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMLine feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_397_UPDMLine | False | True | updmline_globalid |
UUID_64 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_LeakRepairs__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 398 |
Minimum Client Version | 10.1 |
Alias | P_LeakRepairs__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {AE30F5DF-86EA-4AE6-A7E6-A5F32F6250AE} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_398_REL_GLOB | False | True | rel_globalid |
UUID_65 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_LineValveInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 399 |
Minimum Client Version | 10.1 |
Alias | Line Valve Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {8A8F1A61-806F-47A3-9406-1B307CA7F2FB} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_LineValveInspection describes where a line valve inspection was performed in a Regulator or Town Border Station. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
manufacturer | Manufacturer | String | True | Pipeline_Valve_Manufacturer | 0 | 0 | 50 | True | False | The name of the company responsible for the creation of the pig structure. | ||
manufacturemodel | Manufacturer Model | String | True | Pipeline_Valve_Model | 0 | 0 | 30 | True | False | The manufacture model of the equipment. | ||
valvetype | Valve Type | Short Integer | True | Pipeline_Valve_DesignType | 0 | 0 | 2 | True | False | The type of line valve. | ||
figureno | Figure No | String | True | 0 | 0 | 5 | True | False | The figure number of the line valve. | |||
quantity | Quantity | Long Integer | True | 0 | 0 | 4 | True | False | The length of time the pressure monitoring device will be in use. | |||
valvediameter | Valve Diameter | Double | True | Pipeline_Valve_Diameter | 0 | 0 | 8 | True | False | The size (in inches) of the line valve. | ||
lineconnection | Line Connection | String | True | Pipeline_Line_Valve_Connection | 0 | 0 | 20 | True | False | The type of connection the line valve has to the station. | ||
pressure | Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The pressure rating of the line valve. | |||
pressureunits | Pressure Units | Short Integer | True | Units_for_Pressure | 231 | 0 | 0 | 2 | True | False | The unit of measure for defining the operating pressure. | |
valveposition | Valve Position | Short Integer | True | Pipeline_Valve_Position | 0 | 0 | 2 | True | False | The position of the line valve. | ||
comments | Comments | String | True | 0 | 0 | 500 | True | False | The documentation of any other details about the line valve. | |||
updmassembly_globalid | UPDMAssembly GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The foreign key value linking the inspection record to the regulator station containing the line valve that was inspected. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_399_UPDMAsse | False | True | updmassembly_globalid |
UUID_66 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_LineValveInspection__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 400 |
Minimum Client Version | 10.1 |
Alias | P_LineValveInspection__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {4D9200B9-1C03-4342-B3BB-577291191D83} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | GlobalID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_400_REL_GLOB | False | True | rel_globalid |
UUID_67 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_PipeSystemPressureTests |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 401 |
Minimum Client Version | 10.1 |
Alias | Pipe System Pressure Tests |
OID Field | objectid |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {D1A121C2-8610-4FD4-831E-3A0C38067492} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
pipetestdate | Pipe Test Date | Date | True | 0 | 0 | 8 | True | False | The date the newly installed record was pressure tested. | |||
pipetestduration | Pipe Test Duration | Double | True | 0 | 0 | 8 | True | False | The length of time the record was under pressure during the test. | |||
pipetestpressure | Pipe Test Pressure | Double | True | 0 | 0 | 8 | True | False | The internal force to which the record was exposed during the pipe test. | |||
pipetestmedium | Pipe Test Medium | String | True | Pipeline_Pipe_Test_Medium | 0 | 0 | 25 | True | False | The substance used to generate internal pressure in the pipe during pressure testing. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_RegulatorInspect |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 402 |
Minimum Client Version | 10.1 |
Alias | Regulator Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {243333EE-C070-40AF-805D-34A7E43B31A2} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_RegulatorInspect describes the annual inspection required for all regulator stations, border stations, and customer meter sets or stations with a capacity of over 4001 cfh at differential and other specified stations. The inspection is to make sure that all necessary equipment is installed and working properly, that the design of the station is as it should be, and that there are no dangerous or hazardous conditions present. Each station must be examined annually. This inspection is specifically for the regulators in a regulator station. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
manufacturer | Manufacturer | String | True | Pipeline_Regulator_Manufacturer | 0 | 0 | 50 | True | False | The manufacturer of the regulator. | ||
manufacturemodel | Manufacturer Model | String | True | Pipeline_Regulator_Model | 0 | 0 | 30 | True | False | The model name/number of the regulator. | ||
regulatortype | Regulator Type | String | True | Pipeline_Regulator_Type | 0 | 0 | 30 | True | False | Indicates whether the regulator is operating as a monitor or a controller in the regulator station. | ||
regulatordiameter | Regulator Diameter | Double | True | Pipeline_Pipe_Diameter-Combined | 0 | 0 | 8 | True | False | The size, in inches, of the orifice diameter of the regulator. | ||
regulatorconnection | Regulator Connection | String | True | Pipeline_Pipe_Connection_Type | 0 | 0 | 15 | True | False | The type of connection on the regulator. | ||
pressurerating | Pressure Rating | Long Integer | True | 0 | 0 | 4 | True | False | The pressure rating at which the regulator station is qualified. | |||
pressureunits | Pressure Units | Short Integer | True | Units_for_Pressure | 231 | 0 | 0 | 2 | True | False | The unit of measurement used to define pressure. | |
pilotmake | Pilot Make | Long Integer | True | 0 | 0 | 4 | True | False | The make/type of the pilot. | |||
pilotconnectiontype | Pilot Connect Type | String | True | Pipeline_Pilot_Connection_Type | 0 | 0 | 15 | True | False | The type of connection used for the pilot. | ||
flow | Flow | String | True | Pipeline_Flow | 0 | 0 | 15 | True | False | The note stating whether this regulator is the upstream or downstream regulator. | ||
intermediatepressure | Intermediate Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The determined and entered intermediate pressure for working monitor applications. | |||
outletpressure | Outlet Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The determined and entered outlet set pressures. If the outlet pressure can get higher than the MAOP downstream, determine that proper safety devices are used. | |||
maxinletpressure | Max Inlet Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The determined and entered maximum inlet pressure. | |||
minoutletpressure | Min Outlet Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The determined and entered minimum inlet pressure. | |||
internalinspection | Internal Inspection | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The text column indicating whether internal inspection is to be performed. | |
innervalve | Inner Valve | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The text column indicating whether the regulators inner valve passed or failed inspection. The default value is Not Inspected. | |
innervalvediameter | Inner Valve Diameter | Double | True | Pipeline_Pipe_Diameter-Combined | 0 | 0 | 8 | True | False | The measured internal diameter of the inspected inner valve. | ||
internallockup | Internal Lockup | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The text column indicating whether the lockup passed or failed inspection. | |
internalsetpressure | Internal Set Pressure | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal set pressure passed or failed inspection. | |
internaldiaphragmposition | Internal Diaphragm Position | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal diaphragm passed or failed inspection. | |
internalventposition | Internal Vent Position | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal vent position passed or failed inspection. | |
internalpilots | Internal Pilots | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal pilots passed or failed inspection. | |
internalcontrollinesclear | Internal Control Lines Clear | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal control lines passed or failed inspection. | |
internalvalvessecured | Internal Valve Secured | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The attribute indicating whether the internal valves were secured and thereby passed or failed inspection. | |
comments | Comments | String | True | 0 | 0 | 500 | True | False | Any comments or issues as a result of the regulator inspection. | |||
updmdevice_globalid | UPDMDevice GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMDevice feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The foreign key value linking the inspections record to the regulator being inspected. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The name of the system user who originally created the object record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The date and time the object record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The name of the system user responsible for the last modification to the object record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The date and time the object record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_402_UPDMDevi | False | True | updmdevice_globalid |
UUID_69 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_RegulatorInspect__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 403 |
Minimum Client Version | 10.1 |
Alias | P_RegulatorInspect__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {18752AA9-BFF6-46FD-B1DA-D9098A602008} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_403_REL_GLOB | False | True | rel_globalid |
UUID_70 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_ReliefValveInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 404 |
Minimum Client Version | 10.1 |
Alias | Relief Valve Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {F867D31D-332F-4322-8C8D-922FB8C55DBB} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The set pressure of all separated relief devices (except rupture disks) shall be tested in place any time the meter set is turned on, changed out, or field tested. Verify the relief capacity using calculations or flow charts to determine that they have enough capacity to limit the downstream pressure to the MAOP plus allowable buildup. When calculations are made to verify relief capacity, keep documentation current showing calculations for audit purposes. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
manufacturer | Manufacturer | String | True | Pipeline_Valve_Manufacturer | 0 | 0 | 50 | True | False | The name of the company responsible for the creation of the pig structure. | ||
manufacturemodel | Manufacturer Model | String | True | Pipeline_Valve_Model | 0 | 0 | 30 | True | False | The manufacture model of the equipment. | ||
valvetype | Relief Valve Type | String | True | 0 | 0 | 30 | True | False | The type of relief or shutoff valve. | |||
internaltoregulator | Internal to Regulator | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve is internal to the regulator. | |
tokenrelief | Token Relief | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the device uses a token for relief. | |
properreplacement | Proper Replacement | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no boolean value indicating whether the shutoff device is in the proper place in the setting. | |
pressurerating | Pressure Rating | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The pressure rating at which the feature is qualified. | |
innersize | Inner Size | Long Integer | True | 0 | 0 | 4 | True | False | The diameter of the inner valve. | |||
flowcritical | Flow Critical | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether a loss of service would be critical to the pipe system if the device shuts off the flow. | |
safeprotected | Safe Protected | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the relief valve itself is in a safe location and has proper protection around it. | |
stackcovers | Stack Covers | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the relief stack is free of and protected against obstructions. | |
setpointpressure | Set Point Pressure | Long Integer | True | 0 | 0 | 4 | True | False | The proper set point pressure reached when the relief valve(s) will begin to open in case of excessive pressure buildup. | |||
devicereaction | Device Reaction | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The test to ensure the regulator can pass at maximum pressure conditions without over pressuring the downstream piping or the customers equipment in case of failure of the regulator. Test the shutoff valve to the point that it actually shuts off. | |
capacitymaop | Capacity MAOP | Long Integer | True | 0 | 0 | 4 | True | False | The calculated relief valve maximum allowable operating pressure. | |||
updmassembly_globalid | UPDMAssembly GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The foreign key value linking the inspection record to the pipeline facility containing the valve that was inspected. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_404_UPDMAsse | False | True | updmassembly_globalid |
UUID_71 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_ReliefValveInspection__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 405 |
Minimum Client Version | 10.1 |
Alias | P_ReliefValveInspection__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {AC3A3603-C135-4195-A868-FDF3CEA10D4C} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_405_REL_GLOB | False | True | rel_globalid |
UUID_72 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_StationVisualInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 406 |
Minimum Client Version | 10.1 |
Alias | Station Visual Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {0995D04E-AF69-4D53-A07E-8F0B51815240} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_StationVisualInsp describes the condition of a compressor, pump, regulator, or town border station that must be visually verified. If a check results in Fail, follow-up activities are scheduled to remedy the deficiency. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
trashweeds | Trash Weeds | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for presence of trash and weeds. | |
atmoscorrosion | Atmospheric Corrosion | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for presence of atmospheric corrosion. | |
paintcondition | Paint Condition | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for paint condition of the station. | |
detectableleaks | Detectable Leaks | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for any detectable leaks. | |
damagetofacilities | Damage to Facilities | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for any damage to the facilities. | |
enclosurecondition | Enclosure Recondition | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for the condition of the station enclosure. | |
bolts | Bolts | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for bolts where applicable. | |
supportpipingrigid | Support Piping Rigid | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check to ensure the support piping is rigid. | |
stationguards | Station Guards | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for the condition of the station guards. | |
valveboxcondition | Valve Box Condition | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check for the condition of the valve box. | |
warningsignsinplace | Warning Signs in Place | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The check to ensure the warning signs are in place. | |
updmassembly_globalid | UPDMAssembly GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The foreign key value linking the inspection record to the pipeline facility containing the valve that was inspected. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_406_UPDMAsse | False | True | updmassembly_globalid |
UUID_73 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_StationVisualInspection__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 407 |
Minimum Client Version | 10.1 |
Alias | P_StationVisualInspection__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {7B618229-6AB6-432B-8B4A-CE4745949F3E} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_407_REL_GLOB | False | True | rel_globalid |
UUID_74 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_StrainerInspect |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 408 |
Minimum Client Version | 10.1 |
Alias | Strainer Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {40F61810-9FB4-45E2-AC9D-E5EA6E24D67E} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_StrainerInspect describes the equipment inspection performed on the strainers contained in compressors, pumps, regulators, and town border stations. Inspect the strainer screens for damage or erosion and clean or replace as necessary. The inspection should occur at least once each calendar year and at intervals not exceeding 15 months. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
strainermanufacturer | Strainer Manufacturer | String | True | Pipeline_Strainer_Manufacturer | 0 | 0 | 50 | True | False | The name of the manufacturer of the strainer or filter. | ||
strainermodel | Strainer Model | String | True | Pipeline_Strainer_Model | 0 | 0 | 30 | True | False | The manufacturer name/number of the type of strainer or filter. | ||
controllinemanufacturer | Control Line Manufacturer | String | True | Pipeline_Control_Line_Manufacturer | 0 | 0 | 50 | True | False | The name of the manufacturer of the control line. | ||
controllinemodel | Control Line Model | String | True | Pipeline_Control_Line_Model | 0 | 0 | 30 | True | False | The manufacturer name/number of the type of control line. | ||
devicetype | Device Type | String | True | Pipeline_Strainer_Device_Type | 0 | 0 | 15 | True | False | The type of device. | ||
differentialpressure | Differential Pressure | Short Integer | True | Pipeline_Pass_Fail_Status | 0 | 0 | 0 | 2 | True | False | The status of the filter cartridges or screens for indication of excessive differential pressure. | |
leaks | LEAKS | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether leaks were found during the inspection. | |
comments | Comments | String | True | 0 | 0 | 150 | True | False | Any comments or issues as a result of the strainer inspection. | |||
updmdevice_globalid | UPDMDevice GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMDevice feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_408_UPDMDevi | False | True | updmdevice_globalid |
UUID_75 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_StrainerInspect__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 409 |
Minimum Client Version | 10.1 |
Alias | P_StrainerInspect__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {A57BB284-6B06-4820-B4B0-A338E058D769} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_409_REL_GLOB | False | True | rel_globalid |
UUID_76 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_ValveInspection |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 410 |
Minimum Client Version | 10.1 |
Alias | Valve Inspection |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {1FE6EC3D-0A73-40CF-B9E1-D3F8D8F283EA} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The table P_ValveInspection describes the U.S. DOT required inspection of valves. Each operating location must inspect and perform necessary maintenance on all valves that are installed in the system to permit sectionalizing or emergency shutoff. Keep a record of all valve inspections by each location. Each valve must be examined at least once each calendar year and at intervals not exceeding 15 months. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
inspectedby | Inspected By | String | True | 0 | 0 | 50 | True | False | The name of the field technician who performed the inspection. | |||
dateinspected | Date Inspected | Date | True | 0 | 0 | 8 | True | False | The date and time the gas operations field technician recorded the information for this record. | |||
inspectednumber | Inspected Number | String | True | 0 | 0 | 20 | True | False | The unique ID generated by an asset management system to uniquely identify the inspection. | |||
systemtype | System Type | Short Integer | True | Pipeline_Regulatory_Type | 0 | 0 | 2 | True | False | The type of system where the valve is installed. | ||
atmoscorrosion | Atmospheric Corrosion | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether atmospheric corrosion was present. | |
requirepaint | Differential Pressure | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve requires painting. | |
goodcondition | Good Condition | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve is working properly and in good condition. | |
requirelubrication | Require Lubrication | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve requires lubrication. | |
lubricated | Lubricated | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve was lubricated. | |
tagged | Tagged | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve was tagged properly. | |
operating | Operating | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve is operating correctly. | |
secured | Secured | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve is secured from unauthorized access. | |
accessible | Accessible | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The value used by the isolation trace tool to identify when a valve is no longer accessible for the purpose of emergency shutoffs. | |
signs | Signs | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether signs are present and current. | |
valveboxcond | Valve Box Condition | Short Integer | True | Gas_Valve_Condition | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valve box is in good condition. | |
protectfromdamage | Protect From Damage | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the valves are protected from accidental damage by vehicular traffic. | |
reviewedby | Reviewed By | String | True | 0 | 0 | 50 | True | False | The name of the supervisor or designated person who reviewed the valve maintenance record. | |||
revieweddate | Reviewed Date | Date | True | 0 | 0 | 8 | True | False | The date the valve maintenance record was reviewed. | |||
comments | Comments | String | True | 0 | 0 | 500 | True | False | Any pertinent information. | |||
updmdevice_globalid | UPDMDevice GlobalID | GUID | Index | True | 0 | 0 | 38 | True | False | The UPDMDevice feature class globalid value of the record with which the field inspection is associated. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_410_UPDMDevi | False | True | updmdevice_globalid |
UUID_77 | True | True | globalid |
FDO_objectid | True | True | objectid |
Key | Value |
---|---|
Name | main.P_ValveInspection__ATTACH |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 411 |
Minimum Client Version | 10.1 |
Alias | P_ValveInspection__ATTACH |
OID Field | attachmentid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {E94E2FA1-3426-4060-96F3-BAC993D7E6C4} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
attachmentid | ATTACHMENTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
rel_globalid | REL_GLOBALID | GUID | Index | False | 0 | 0 | 38 | True | False | |||
content_type | CONTENT_TYPE | String | False | 0 | 0 | 150 | True | False | ||||
att_name | ATT_NAME | String | False | 0 | 0 | 250 | True | False | ||||
data_size | DATA_SIZE | Long Integer | False | 0 | 0 | 4 | True | False | ||||
data | DATA | Blob | True | 0 | 0 | 0 | True | False | ||||
globalid | GLOBALID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | ||||
creator | Creator | String | True | 0 | 0 | 255 | True | True | ||||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | ||||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | ||||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_411_REL_GLOB | False | True | rel_globalid |
UUID_78 | True | True | globalid |
FDO_attachmentid | True | True | attachmentid |
Key | Value |
---|---|
Name | main.P_AlignmentSheet |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 412 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | False |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Alignment Sheet |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {1DE77882-A0C0-4E0A-BF83-3554EC1E0838} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygon feature class P_AlignmentSheet describes the spatial extent along a pipeline to be used to generate a map layout. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
sheetname | Sheet Name | String | True | 0 | 0 | 45 | True | False | The unique name used to identify a single map sheet. | |||
sheetnumber | Sheet Number | String | True | 0 | 0 | 45 | True | False | The unique alphanumeric value used to identify a single map sheet. | |||
sheettype | Sheet Type | String | True | Pipeline_Alignment_Sheet_Type | Unknown | 0 | 0 | 45 | True | False | The type of map series that this map sheet will generate. | |
status | Status | String | True | Pipeline_Object_Status | Active | 0 | 0 | 15 | True | False | The life cycle status of the alignment sheet. | |
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_79 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_AlignmentSheet_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_CapitalProject |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 416 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | False |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Capital Project |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {6DFEFD1E-BF41-4F95-8466-BD717AB95DAC} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygon feature class P_CapitalProject describes the location where the organization plans to perform work that is financed through capital funding. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
projectname | Project Name | String | True | 0 | 0 | 50 | True | False | The textual name associated with the capital project. | |||
projectid | ProjectID | Short Integer | True | 0 | 0 | 2 | True | False | The project management assigned unique identifier for the capital project. | |||
status | Status | String | True | Pipeline_Object_Status | Active | 0 | 0 | 15 | True | False | The life cycle state of the capital project. | |
assignedto | Assigned To | String | True | 0 | 0 | 50 | True | False | The name of the department to which the project is currently assigned. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the project. | |||
percomplete | Percent Complete | Double | True | 0 | 0 | 8 | True | False | An indicator on the progress of completing the capital project. | |||
estmaterialcost | Estimated Material Cost | Double | True | 0 | 0 | 8 | True | False | The projects estimated total cost of materials required to complete the project. | |||
estlaboreqptcost | Estimated Labor and Equipment Cost | Double | True | 0 | 0 | 8 | True | False | The projects estimated total cost of labor and equipment required to complete the project. | |||
esttotalocst | Estimated Total Cost | Double | True | 0 | 0 | 8 | True | False | The estimated total cost of the capital project. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_83 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_CapitalProject_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_DrinkingWater |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 426 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Drinking Water |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {CC2FADF0-A5E9-4F05-AD4D-63D663E323CA} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_DrinkingWater describes U.S. drinking water resources, as defined at 49 CFR 195.6, that constitute a hazardous liquids pipeline high consequence area (HCA). CFR 195.6 defines a drinking water resource area as those locations where a community water system or a nontransient, noncommunity water system obtains its drinking water and does not have an adequate alternative drinking water source. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
drinkingwatername | Drinking Water Name | String | True | 0 | 0 | 50 | True | False | The name of the drinking water resource. | |||
drinkingwatertype | Drinking Water Type | String | True | 0 | 0 | 50 | True | False | The text value indicating the drinking water resources classification. Valid values are water intake, source water protection area, or sole source aquifer recharge area. | |||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating the state of the drinking water resource and whether it qualifies as an HCA. | ||
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the drinking water resource was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the drinking water resource became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the drinking water resource. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_93 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_DrinkingWater_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_EcologicalArea |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 427 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Ecological Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {B83E36CC-FCDC-4872-8D9A-9369F4F7DEAB} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_EcologicalArea describes U.S. locations, as defined at 49 CFR 195.6, that constitute a hazardous liquids pipeline high consequence area (HCA) by reason of being an ecological area. CFR 195.6 defines an ecological area as an area that is unusually sensitive to environmental damage from a hazardous liquid pipeline release. Types of ecological areas include areas containing a critically imperiled species or ecological community, a multispecies assemblage area, and a migratory water bird concentration area. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
areaname | Area Name | String | True | 0 | 0 | 50 | True | False | The name of the ecological area. | |||
ecologicalareatype | Ecological Area Type | String | True | 0 | 0 | 50 | True | False | The text value indicating the classification of the location pursuant to 49 CFR 195.6(b). | |||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating the status of the ecological area for HCA purposes. | ||
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the ecological area was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the ecological area became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the ecological area. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_94 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_EcologicalArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_HighPopulatedArea |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 434 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | High Populated Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {C73A7FDF-70AA-46A0-B7E0-C5C5A7D58C8A} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_HighPopulatedArea describes U.S. locations, as defined at 49 CFR 195.450, that constitute a hazardous liquids pipeline high consequence area (HCA) by reason of being highly populated. CFR 195.450 defines a highly populated area as a Census Bureau delineated urbanized area that has 50,000 or more people and a population density of at least 1,000 people per square mile. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
areaname | Area Name | String | True | 0 | 0 | 50 | True | False | The name of the populated area. | |||
areatype | Ecological Area Type | String | True | 0 | 0 | 50 | True | False | The type of highly populated area. | |||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The entity and data product name from which knowledge of the highly populated area became known. | ||
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the highly populated area was defined. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the highly populated area became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the highly populated area. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_101 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_HighPopulatedArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_LeakSurveyArea |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 444 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Leak Survey Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {3081AAC8-48CF-4775-8D89-AE2DA18573A8} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygon feature class P_LeakSurveyArea is for capturing the information associated with compliance with federal regulations. The following are a sampling of federal regulations: |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
surveytype | Survey Type | String | True | Pipeline_Leak_Survey_Type | 0 | 0 | 30 | True | False | The type of leak survey to be performed within the spatial extent of the polygon. | ||
mapgridname | Map Grid Name | String | True | 0 | 0 | 20 | True | False | The name of the map grid. | |||
surveystatus | Survey Status | String | True | Pipeline_Leak_Survey_Status | 0 | 0 | 15 | True | False | The current status of the leak survey inspection for a grid. Valid values are Assigned, In Progress, and Completed. | ||
assignedcrewleader | Assigned Crew Leader | String | True | 0 | 0 | 50 | True | False | The system user name of the technician or lead technician who has been assigned to perform the scheduled leak survey inspection of the grid. | |||
surveyedby | Surveyed By | String | True | 0 | 0 | 50 | True | False | The technician who performed the completed survey of the grid. | |||
startdate | Start Date | Date | True | 0 | 0 | 8 | True | False | The date the leak survey inspection was initiated by field staff. | |||
enddate | End Date | Date | True | 0 | 0 | 8 | True | False | The date the area survey of the grid was completed. | |||
duedate | Due Date | Date | True | 0 | 0 | 8 | True | False | The date the leak survey area is next due for inspection. DUEDATE is calculated by adding the interval value (that is, every 60 months for area surveys) to the enddate. | |||
compdate | Compliance Date | Date | True | 0 | 0 | 8 | True | False | The compliance date is the calculated date when the leak survey is out of compliance. The compliance date is calculated by adding the INTERVAL value plus the grace period to the enddate (that is, every 63 months for area surveys). | |||
belowgradeleaks | Below Grade Leaks | Short Integer | True | 0 | 0 | 2 | True | False | The number of leaks identified during the leak survey inspection of the grid area. | |||
surveymethod | Survey Method | String | True | Pipeline_Leak_Survey_Method | 0 | 0 | 30 | True | False | The method used to perform the leak survey inspection. | ||
footagemains | Footage Mains | Double | True | 0 | 0 | 8 | True | False | The calculated footage of the total active mains within the map grid. | |||
numberservices | Number of Services | Long Integer | True | 0 | 0 | 4 | True | False | The calculated number of active services within the map grid. | |||
duration | Duration | Double | True | 0 | 0 | 8 | True | False | The time required by field staff to complete the assigned leak survey. | |||
comments | Comments | String | True | 0 | 0 | 1000 | True | False | Additional descriptors about the leak survey. | |||
interval | Interval | Short Integer | True | Pipeline_Leak_Survey_Frequency | 0 | 0 | 2 | True | False | The frequency as measured in months between surveys. Some state regulatory bodies require a shorter survey frequency interval than the federally mandated 63 months. | ||
assignedhelper1 | Assigned Helper 1 | String | True | 0 | 0 | 50 | True | False | The system user name of the technician who has been assigned to perform the scheduled leak survey inspection of the grid. | |||
assignedhelper2 | Assigned Helper 2 | String | True | 0 | 0 | 50 | True | False | The system user name of the technician who has been assigned to perform the scheduled leak survey inspection of the grid. | |||
assignedhelper3 | Assigned Helper 3 | String | True | 0 | 0 | 50 | True | False | The system user name of the technician who has been assigned to perform the scheduled leak survey inspection of the grid. | |||
remainingfootagemains | Remaining Footage Mains | Double | True | 0 | 0 | 8 | True | False | The calculated footage of the total remaining active mains within the map grid. | |||
remainingservices | Remaining Services | Long Integer | True | 0 | 0 | 4 | True | False | The calculated number of remaining active services within the map grid. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_111 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_LeakSurveyArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_NavigableWaterway |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 446 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | False |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Navigable Waterway |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {085712D9-0D31-40AC-B6E1-EE60565C4451} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_NavigableWaterway describes U.S. locations, as defined at 49 CFR 195.450, that constitute a hazardous liquids pipeline high consequence area (HCA). CFR 195.450 defines a navigable waterway as a water body with a substantial likelihood of commercial navigation. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
waterwayname | Waterway Name | String | True | 0 | 0 | 50 | True | False | The name of the commercially navigable waterway. | |||
waterwaytype | Waterway Type | String | True | 0 | 0 | 50 | True | False | The text value indicating the classification of the waterway. | |||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating the state of qualification as a commercially navigable waterway for HCA purposes. | ||
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the commercially navigable waterway was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the navigable waterway became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the navigable waterway. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_length(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_113 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_NavigableWaterway_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_OtherPopulatedArea |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 448 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Other Populated Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {48883E84-3CA8-4864-8B17-B43581D5A9AD} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_OtherPopulatedArea describes U.S. locations, as defined by 49 CFR 195.450, that constitute other populated area hazardous liquids pipeline high consequence area (HCA). CFR 195.450 defines other populated area as a Census Bureau-delineated area that contains a concentrated population such as an incorporated or unincorporated city, town, village or other designated residential or commercial area. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
populatedareaname | Other Populated Name | String | True | 0 | 0 | 50 | True | False | The Census Bureau-defined name for the populated area. | |||
type | Other Populated Type | String | True | 0 | 0 | 50 | True | False | The type of other populated area. | |||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating the state of qualification of the other populated area for HCA purposes. | ||
occupantcount | Occupant Count | Short Integer | True | 0 | 0 | 2 | True | False | The Census Bureau-defined count of the occupants within the populated area. | |||
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the other populated area was defined. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the other populated area became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the other populated area. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_115 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_OtherPopulatedArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_OutsideArea |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 449 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Outside Area |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {22D7474E-3D7A-45C9-A7B2-15AFA0F05806} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_OutsideArea describes U.S. locations, as defined by 49 CFR 192.903, that constitute an identified site for gas transmission pipeline high consequence area (HCA) determination purposes. CFR 195.903 defines an outside area as an area or open structure that is occupied by 20 or more persons at least 50 days in any 12-month period. Examples include beaches, playgrounds, recreational facilities, camping grounds, outdoor theaters, and stadiums. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
status | Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating whether the location currently qualifies as an outside area for HCA purposes. | ||
identifiedsite | Identified Site | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the outside area represents an identified site. | |
identifiedsitetype | Identified Site Type | String | True | Pipeline_Identified_Site_Outside | 0 | 0 | 30 | True | False | The categorical type of outside area for the identified type. | ||
daysperweek | Days Per Week | Short Integer | True | UPDM_DaysPerWeek | 0 | 0 | 2 | True | False | The number of days per week the outside area is occupied. | ||
weeksperyear | Weeks Per Year | Short Integer | True | UPDM_WeeksPerYear | 0 | 0 | 2 | True | False | The number of weeks per year when the outside area is occupied. | ||
impairedmobility | Impaired Mobility | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the outside area qualifies as an area with persons of impaired mobility. | |
gatheringplace | Gathering Place | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the outside area is considered a gathering place. | |
discoverydate | Discovery Date | Date | True | 0 | 0 | 8 | True | False | The date the outside area was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the outside area became known. | |||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the outside area. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_116 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_OutsideArea_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_StructureFootPrint |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 456 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Structure Footprint |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {F541F845-E9BF-44BC-985E-16AF63FBE27E} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The polygonal feature class P_StructureFootprint describes U.S. locations, as defined by 49 CFR 192.903, that constitute a human occupied building for gas transmission pipeline high consequence area (HCA) determination purposes. This feature class can also be used to determine building counts near the pipeline for DOT pipe classification as defined under 49 CFR 192.5. This polygonal representation of the structure provides an outline of the structures two-dimensional footprint. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
structurename | Structure Name | String | True | 0 | 0 | 50 | True | False | The commonly known name of the structure. | |||
structuretype | Structure Type | String | True | Pipeline_Structure_Type | 0 | 0 | 30 | True | False | The categorical type of human occupied structure. | ||
structurestatus | Structure Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating whether the location currently qualifies as a structure for HCA purposes. | ||
humanoccupancy | Human Occupancy | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is suitable for human occupancy. | |
daysperweek | Days Per Week | Short Integer | True | UPDM_DaysPerWeek | 0 | 0 | 2 | True | False | The number of days per week that the structure is occupied. | ||
limitedmobility | Limited Mobility | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure contains persons with limited ability to evacuate in emergency situations. | |
limitedmobilityreason | Limited Mobility Reason | String | True | Pipeline_Structure_Limited_Mobility | 0 | 0 | 50 | True | False | The reason why the persons in the structure have limited mobility. | ||
impairedmobility | Impaired Mobility | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure contains persons with impaired ability to evacuate in emergency situations. | |
gatheringplace | Gathering Place | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is considered a gathering place. | |
discoverydate | Discovery Place | Date | True | 0 | 0 | 8 | True | False | The date the structure was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the structure became known. | |||
occupantcount | Occupant Count | Short Integer | True | 0 | 0 | 2 | True | False | The number of persons typically in the structure. | |||
numberofstories | Number of Stories | Short Integer | True | 0 | 0 | 2 | True | False | The number of aboveground levels of the structure. | |||
numberofunits | Number of Units | Short Integer | True | 0 | 0 | 2 | True | False | The number of pumps in the pump station facility. | |||
weeksperyear | Weeks Per Year | Short Integer | True | UPDM_WeeksPerYear | 0 | 0 | 2 | True | False | The number of weeks per year that the structure is occupied. | ||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the structure. | |||
identifiedsite | Identified Site | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is identified as a high consequence area. | |
identifiedsitetype | Identified Site Type | String | True | 0 | 0 | 50 | True | False | The categorical type of identified site. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. | ||
st_area(shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_123 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_StructureFootPrint_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_StructurePoint |
Dataset Type | FeatureClass |
Feature Dataset | |
Dataset ID | 457 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Structure Point |
OID Field | objectid |
GlobalID Field | globalid |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max | |
Catalog ID | {1098EAEA-AA1A-4C7C-80C5-3C22BCA11345} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The point feature class P_StructurePoint describes U.S. locations, as defined by 49 CFR 192.903, that constitute a human-occupied building for gas transmission pipeline high consequence area (HCA) determination purposes. This feature class can also be used to determine building counts near the pipeline for DOT pipe classification as defined by 49 CFR 192.5. This point representation of the structure defines the location of the building closest to the pipeline. |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
objectid | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | The geodatabase generated and maintained unique identifier value. | ||
structurename | Structure Name | String | True | 0 | 0 | 50 | True | False | The commonly known name of the structure. | |||
structuretype | Structure Type | String | True | Pipeline_Structure_Type | 0 | 0 | 30 | True | False | The categorical type of human-occupied structure. | ||
structurestatus | Structure Status | String | True | Pipeline_Object_Status | 0 | 0 | 20 | True | False | The text value indicating whether the location currently qualifies as a structure for HCA purposes. | ||
humanoccupancy | Human Occupancy | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is suitable for human occupancy. | |
daysperweek | Days Per Week | Short Integer | True | UPDM_DaysPerWeek | 0 | 0 | 2 | True | False | The number of days per week that the structure is occupied. | ||
limitedmobility | Limited Mobility | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure contains persons with limited ability to evacuate in emergency situations. | |
limitedmobilityreason | Limited Mobility Reason | String | True | Pipeline_Structure_Limited_Mobility | 0 | 0 | 50 | True | False | The reason why the persons in the structure have limited mobility. | ||
impairedmobility | Impaired Mobility | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure contains persons with impaired ability to evacuate in emergency situations. | |
gatheringplace | Gathering Place | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is considered a gathering place. | |
discoverydate | Discovery Place | Date | True | 0 | 0 | 8 | True | False | The date the structure was identified. | |||
source | Source | String | True | 0 | 0 | 50 | True | False | The entity and data product name from which knowledge of the structure became known. | |||
occupantcount | Occupant Count | Short Integer | True | 0 | 0 | 2 | True | False | The number of persons typically in the structure. | |||
numberofstories | Number of Stories | Short Integer | True | 0 | 0 | 2 | True | False | The number of aboveground levels of the structure. | |||
numberofunits | Number of Units | Short Integer | True | 0 | 0 | 2 | True | False | The number of pumps in the pump station facility. | |||
weeksperyear | Weeks Per Year | Short Integer | True | UPDM_WeeksPerYear | 0 | 0 | 2 | True | False | The number of weeks per year that the structure is occupied. | ||
description | Description | String | True | 0 | 0 | 255 | True | False | The textual description of the location of the structure. | |||
identifiedsite | Identified Site | Short Integer | True | Yes_No | 0 | 0 | 0 | 2 | True | False | The yes/no Boolean value indicating whether the structure is identified as a high consequence area. | |
identifiedsitetype | Identified Site Type | String | True | 0 | 0 | 50 | True | False | The categorical type of identified site. | |||
spatialaccuracy | Spatial Accuracy | Short Integer | True | Spatial_Accuracy | 0 | 0 | 2 | True | False | This short integer value provides an assessment of the spatial accuracy of the coordinates of the record's geometry when the record is included in the geodatabase. | ||
gpsx | GPS X | Double | True | 0 | 0 | 8 | True | False | The longitudinal coordinate of the record when it was originally included in the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
gpsy | GPS Y | Double | True | 0 | 0 | 8 | True | False | The latitudinal coordinate of the record when it was originally inserted into the geodatabase. If using the attribute rules capability, this value can be automatically populated. | |||
creator | Creator | String | True | 0 | 0 | 255 | True | True | The name of the system user who originally created the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
creationdate | Creation date | Date | True | 0 | 0 | 8 | True | True | The date and time the record was originally created in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
updatedby | Updated by | String | True | 0 | 0 | 255 | True | True | The name of the system user responsible for the last modification to the record in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
lastupdate | Last update | Date | True | 0 | 0 | 8 | True | True | The date and time the record was last modified in the geodatabase. This value is automatically populated by the Editor Tracking. | |||
globalid | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | The systemwide unique identifier. | ||
created_user | created_user | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | created_date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | last_edited_user | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | last_edited_date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | Geometry of the feature. |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_124 | True | True | globalid |
FDO_objectid | True | True | objectid |
st_spindex__P_StructurePoint_shape | True | True | shape |
Key | Value |
---|---|
Name | main.P_DocumentPoint__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 460 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_DocumentPoint |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_DocumentPoint__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {4DA5E5A1-774A-43BB-9E8E-D56F472C2043} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_GasLeakInspect__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 463 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_GasLeakInspect |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_GasLeakInspect__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {53B62ACD-5E62-421E-AE2D-181E570F1AD4} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_LineValveInspection__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 472 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_LineValveInspection |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_LineValveInspection__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {04858B10-0067-41D0-9FB8-6FDDF10E5CA8} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_RegulatorInspect__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 475 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_RegulatorInspect |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_RegulatorInspect__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {1488F454-DAA2-43C8-8A08-47BC1CD92757} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_ReliefValveInspection__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 476 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_ReliefValveInspection |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_ReliefValveInspection__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {F2C715ED-9519-4356-9C86-DAF43BEF2E19} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_StationVisualInspection__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 477 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_StationVisualInspection |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_StationVisualInspection__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {B63C82FA-8F98-45A7-99B3-B37D91DF7E98} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_StrainerInspect__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 478 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_StrainerInspect |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_StrainerInspect__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {942D438E-8ED4-4AA9-88FC-4FF280AEBF71} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Name | main.P_ValveInspection__ATTACHREL |
Dataset Type | RelationshipClass |
Feature Dataset | |
Dataset ID | 479 |
Type | Composite |
Cardinality | One To Many |
Notification | None |
Is Attachment | True |
Is Attributed | False |
Origin Name | main.P_ValveInspection |
Origin Primary Key | GlobalID |
Origin Foreign Key | REL_GLOBALID |
Destination Name | main.P_ValveInspection__ATTACH |
Destination Primary Key | |
Destination Foreign Key | |
Forward Path Label | attachment |
Backward Path Label | object |
Split Policy | |
Minimum Client Version | 10.0 |
Alias | |
OID Field | |
GlobalID Field | |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | False |
Editor Tracking UTC | |
Creator Field | |
Create Date Field | |
Editor Field | |
Edit Date Field | |
Catalog ID | {EC55021F-041D-4EB3-8289-8BD6004EB524} |
Class ID | |
Extension Class ID |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Line_Heater_Model |
Description | List of valid models of oil and gas storage Line Heaters |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 15 | Line Heater | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | UPDM_WeeksPerYear |
Description | Valid Range of values for the number of weeks per year |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Geometry Ratio |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 3 |
Minimum | Maximum |
---|---|
0 | 52 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_OutsideArea | weeksperyear | ||
main.P_StructureFootPrint | weeksperyear | ||
main.P_StructurePoint | weeksperyear |
Key | Value |
---|---|
Owner | |
Domain Name | UPDM_DaysPerWeek |
Description | Valid Range of values for the number of days per week |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Geometry Ratio |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 3 |
Minimum | Maximum |
---|---|
0 | 7 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_OutsideArea | daysperweek | ||
main.P_StructureFootPrint | daysperweek | ||
main.P_StructurePoint | daysperweek |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Line_Heater |
Description | The Asset Types for the PipelineJunction's Asset Group Line Heater |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A line heater fitting whose type is unknown. |
561 | Line Heater | A generic line heater. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 15 | Line Heater | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pressure_Test_Medium |
Description | List of Valid Materials used to test pressure in a pipe system |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Air | Air | |
Gas | Gas | |
Nitrogen | Nitrogen | |
Inert Gas | Inert Gas | |
Water | Water | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_TestPressureRange | testmedium |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Cooling_System |
Description | The Asset Types for the PipelineJunction's Asset Group Cooling System |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A cooling system fitting whose type is unknown. |
601 | Cooling System | A generic Cooling System. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 16 | Cooling System | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Junction_Angle |
Description | Valid Range of PipelineJunction angles for Pipe Bends and Elbows |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 2 |
Minimum | Maximum |
---|---|
0 | 90 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 2 | Elbow | angle |
main.PipelineJunction | 30 | Pipe Bend | angle |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Position |
Description | Indicates if the valve is open or closed |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Closed | |
1 | Open |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 1 | Excess Flow Valve | normalposition |
main.PipelineDevice | 3 | Controllable Valve | normalposition |
main.PipelineDevice | 12 | Controllable Tee | normalposition |
main.P_LineValveInspection | valveposition |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Measured_Length |
Description | Valid Range of values for gas pipe lengths |
Field Type | Double |
Domain Type | Range |
Split Policy | Geometry Ratio |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 7 |
Minimum | Maximum |
---|---|
0 | 1000000000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | measuredlength |
main.PipelineLine | 2 | Distribution Pipe | measuredlength |
main.PipelineLine | 3 | Transmission Pipe | measuredlength |
main.PipelineLine | 4 | Gathering Pipe | measuredlength |
main.PipelineLine | 5 | Station Pipe | measuredlength |
main.PipelineLine | 6 | Customer Pipe | measuredlength |
main.PipelineLine | 8 | Storage Pipe | measuredlength |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Tap_DesignType |
Description | List of types for taps |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
841 | Flexolet | |
842 | Nipple | |
843 | PigSig | |
844 | Tap | |
845 | Thredolet | |
846 | Weldolet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 25 | Tap | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Device_Pressure_Rating |
Description | List of valid device pressure ratings |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 15 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
150 | 150 | |
300 | 300 | |
600 | 600 | |
900 | 900 | |
1500 | 1500 | |
2500 | 2500 |
Key | Value |
---|---|
Owner | |
Domain Name | Symbol_Rotation |
Description | Valid Range of degrees for rotation |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 76 |
Minimum | Maximum |
---|---|
0 | 359 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pilot_Connection_Type |
Description | Method used to connect a pilot |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Screw | Screw | |
Flange | Flange |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | pilotconnectiontype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Drip |
Description | The Asset Types for the PipelineJunction's Asset Group Drip |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A drip fitting whose type is unknown. |
761 | Drip | A generic Drip component. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 20 | Drip | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Relief_Valve_DesignType |
Description | List of types for relief valves |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
21 | Pilot Operated | |
22 | Pressure Relief | |
23 | Rupture Disk | |
24 | Spring Operated | |
25 | Vacuum Relief | |
26 | Vacuum Pressure Relief |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 5 | Relief Valve | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Controllable_Valve |
Description | The Asset Types for the PipelineDevice's Asset Group Controllable Valve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Controllable Valve is unknown asset type. |
482 | Bypass | A bypass controllable valve is a device typically located within a facility such as a regulator station or pump station. Its purpose is to allow or disallow the flow of the commodity around the facilities primary devices such as a regulator or pump. |
485 | System | A system controllable valve is a device capable of impeding the flow of the commodity through the pipe system. The system controllable valve is not considered a source for the commodity in an isolation subnetwork. |
483 | Emergency | An emergency controllable valve is a device capable of impeding the flow of the commodity through the pipe system. The emergency controllable valve is considered a source for the commodity in an isolation subnetwork. |
486 | Meter | A meter controllable valve is the valve located within a meter set. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Flow |
Description | Description of whether the device is considered upstream or downstream within the gas facility |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Upstream | Upstream | |
Downstream | Downstream |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | flow |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pressure_Range |
Description | Valid Range of values for pipeline pipe pressure |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 179 |
Minimum | Maximum |
---|---|
0 | 10000 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Storage_Facility |
Description | The Asset Types for the PipelineAssembly's Asset Group Storage Facility |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
31 | Underground | |
32 | Tank Farm |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 12 | Storage Facility | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FeatureSourceID |
Description | The source feature class name in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Association | |
2 | System Junction | |
3 | System Junction Object | |
4 | Structure Junction | |
5 | Structure Line | |
6 | Structure Boundary | |
7 | Structure Junction Object | |
8 | Structure Edge Object | |
9 | Pipeline Device | |
10 | Pipeline Line | |
11 | Pipeline Assembly | |
12 | Pipeline Junction | |
13 | Pipeline Subnet Line | |
14 | Pipeline Junction Object | |
15 | Pipeline Edge Object |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsContentVisible |
Description | Indicates if the content or attachment association is visible for containment associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FlowDirection |
Description | Indicates how the feature flows in network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 23 |
Code | Description | Details |
---|---|---|
1 | With digitized | |
2 | Against digitized | |
3 | Indeterminate |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierTopologyType |
Description | The type of topology for each tier. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Radial | |
2 | Mesh |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Crossing_Transportation |
Description | Type of transportation features crossing the pipeline |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Bicycle Trail | Bicycle Trail | |
Local Road | Local Road | |
Major Road | Major Road | |
Highway | Highway | |
Interstate | Interstate | |
Private Road | Private Road | |
Driveway | Driveway | |
Railroad | Railroad | |
Subway | Subway | |
Airport Runway | Airport Runway | |
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeCrossing | 3 | Transportation | crossingfeaturetype |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_AssociationStatus |
Description | Indicates how the feature participates in associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 36 |
# of Assignments | 111 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Container | |
2 | Structure | |
4 | Content | |
5 | Content and Container | |
6 | Content and Structure | |
8 | Attachment | |
9 | Attachment and Container | |
10 | Attachment and Structure | |
12 | Attachment and Content | |
13 | Attachment and Content and Container | |
14 | Attachment and Content and Structure | |
16 | Visible Content | |
17 | Visible Content and Container | |
18 | Visible Content and Structure | |
24 | Visible Content and Attachment | |
25 | Visible Content and Attachment and Container | |
26 | Visible Content and Attachment and Structure | |
32 | Connectivity | |
33 | Connectivity and Container | |
34 | Connectivity and Structure | |
36 | Connectivity and Content | |
37 | Connectivity and Content and Container | |
38 | Connectivity and Content and Structure | |
40 | Connectivity and Attachment | |
41 | Connectivity and Attachment and Container | |
42 | Connectivity and Attachment and Structure | |
44 | Connectivity and Attachment and Content | |
45 | Connectivity and Attachment and Content and Container | |
46 | Connectivity and Attachment and Content and Structure | |
48 | Connectivity and Visible Content | |
49 | Connectivity and Visible Content and Container | |
50 | Connectivity and Visible Content and Structure | |
56 | Connectivity and Visible Content and Attachment | |
57 | Connectivity and Visible Content and Attachment and Container | |
58 | Connectivity and Visible Content and Attachment and Structure |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDirty |
Description | Indicates if a subnetwork is clean, dirty, or invalid. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 6 |
Code | Description | Details |
---|---|---|
0 | Clean | |
1 | Dirty | |
2 | Invalid |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineSubnetLine | ISDIRTY | ||
main.PipelineSubnetLine | 0 | Unknown | ISDIRTY |
main.PipelineSubnetLine | 1 | Cathodic Protection | ISDIRTY |
main.PipelineSubnetLine | 2 | System | ISDIRTY |
main.PipelineSubnetLine | 3 | Pressure | ISDIRTY |
main.PipelineSubnetLine | 4 | Isolation | ISDIRTY |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Work_Performed |
Description | List of the work performed to repair a leak |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 15 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Avon Seal | Avon Seal | |
Electro-Fuse Fitting | Electro-Fuse Fitting | |
Fused Fitting | Fused Fitting | |
Grease Valve | Grease Valve | |
Leak Clamp | Leak Clamp | |
Negative Report | Negative Report | |
Replaced Clamp | Replaced Clamp | |
Replaced Fitting | Replaced Fitting | |
Replaced Pipe | Replaced Pipe | |
Replaced Regulator | Replaced Regulator | |
Retired Drop | Retired Drop | |
Retired Pipe | Retired Pipe | |
Tighten Bolts/Nuts | Tighten Bolts/Nuts | |
Turn Valve | Turn Valve | |
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakRepairs | workperformed |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDeleted |
Description | Indicates if a subnetwork has been marked for deletion. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Install_Method |
Description | List of valid types of methods for installing Pipeline Lines |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 8 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Trench | |
2 | Joint Trench | |
3 | Insertion | |
4 | Direct Bore | |
5 | Split and Pull | |
6 | Assemble |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Wellhead |
Description | The Asset Types for the PipelineAssembly's Asset Group Wellhead |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A wellhead facility of unknown configuration type. |
201 | Mudline | A wellhead designed for deeper water that includes a series of hangers called mudline suspension equipment. |
202 | Subsea | A wellhead located on the ocean floor. |
203 | Surface | A wellhead located on land. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_AC_Mitigation_Wire |
Description | The Asset Types for the PipelineLine's Asset Group AC Mitigation Wire |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
921 | Mitigation Wire |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 54 | AC Mitigation Wire | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | AP_Category_Configure |
Description | List of configurations |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 0 |
# of Assignments | 0 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Compressor_Station |
Description | The Asset Types for the PipelineAssembly's Asset Group Compressor Station |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A compressor station of unknown configuration type. |
1 | Compressor Station | A compressor station of generic configuration. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 1 | Compressor Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_UnknownAssetType |
Description | The AssetType domain for the Unknown AssetGroup. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | AnnotationStatus |
Description | Valid annotation state values. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Placed | |
1 | Unplaced |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Manager |
Description | The manager of the asset |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 101 |
Code | Description | Details |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Tank |
Description | The Asset Types for the PipelineJunction's Asset Group Tank |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A tank fitting whose type is unknown. |
521 | Tank | A generic type of Tank. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 14 | Tank | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Owner |
Description | The owner of the asset |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 101 |
Code | Description | Details |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Elbow_Manufacture_Component |
Description | List of ASTM F-2897 types of Elbow Manufacture Models |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 20 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
50 | Other Elbow | |
51 | Butt fusion 90 Elbow | |
52 | Socket fusion 90 Elbow | |
53 | Electrofusion 90 Elbow | |
54 | Mechanical compression or nut follower Elbow | |
55 | Mechanical stab 90 Elbow | |
56 | Mechanical interference fit 90 Elbow | |
57 | Welded 90 Elbow | |
58 | Threaded 90 Elbow | |
59 | Fabricated 90 Elbow | |
5A | Butt fusion 45 Elbow | |
5B | Socket fusion 45 Elbow | |
5C | Electrofusion 45 Elbow | |
5D | Mechanical compression or nut follower 45 Elbow | |
5E | Mechanical stab 45 Elbow | |
5F | Mechanical interference fit 45 Elbow | |
5G | Welded 45 Elbow | |
5H | Threaded 45 Elbow | |
5J | Fabricated 45 Elbow | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 2 | Elbow | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Saddle |
Description | The Asset Types for the PipelineJunction's Asset Group Saddle |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A saddle fitting whose typel is unknown. |
481 | Metal Saddle | A saddle whose primary material is metallic. |
482 | Plastic Saddle | A saddle whose primary material is plastic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 13 | Saddle | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Rural_Tap |
Description | The Asset Types for the PipelineAssembly's Asset Group Rural Tap |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A rural tap station of unknown configuration type. |
121 | Rural Tap | A rural tap facility of generic configuration. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 4 | Rural Tap | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Cathodic_Assembly |
Description | The Asset Types for the PipelineAssembly's Asset Group Cathodic Assembly |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
361 | Groundbed Assembly | |
362 | Junction Box |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 11 | Cathodic Assembly | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Flange |
Description | The Asset Types for the PipelineJunction's Asset Group Flange |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A flange fitting whose primary material is unknown. |
161 | Metal Flange | A flange fitting whose primary material is metallic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 5 | Flange | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Fitting_Assembly |
Description | The Asset Types for the PipelineAssembly's Asset Group Fitting Assembly |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A fitting assembly of unknown configuration. |
281 | Service Tap | The location where a service pipe meets the main line. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 8 | Fitting Assembly | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Meter_Setting |
Description | The Asset Types for the PipelineAssembly's Asset Group Meter Setting |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A meter setting whose configuration is unknown. |
41 | Meter Set | A meter setting of generic configuration. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 2 | Meter Setting | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Muffler |
Description | The Asset Types for the StructureJunction's Asset Group Muffler |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe muffler of unknown type. |
1 | Muffler | A generic muffler component. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 1 | Pipe Muffler | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Boundary_Processing_Facility |
Description | The Asset Types for the StructureBoundary's Asset Group Processing Facility |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pipe Processing Facility of unknown type. |
41 | Processing Facility | A Pipe Processing Facility of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 3 | Pipe Processing Facility | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Pigging_Structure |
Description | The Asset Types for the PipelineAssembly's Asset Group Pigging Structure |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pigging structure facility of unknown configuration. |
241 | Launcher | A launcher is the pigging structure where the pigging device is inserted. into the pipe system. |
242 | Receiver | A receiver is the pigging structure where the pigging device is extracted. from the pipe system. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 7 | Pigging Structure | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Anode |
Description | The Asset Types for the Device's Asset Group Anode |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An Anode of unknown asset type. |
901 | ICCP | Impressed current cathodic protection anode is an anode which participates in an active cathodic protection system. An ICCP system includes an electric current input device, such as a rectifier. |
902 | Galvanic | A Galvanic anode is an anode which participates in a passive cathodic protection system, which does not have an electric current input device such as a rectifier. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 50 | Anode | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Valve_Assembly |
Description | The Asset Types for the PipelineAssembly's Asset Group Valve Assembly |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A valve assembly of unknown configuration. |
61 | Valve Assembly | A valve assembly of generic configuration. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 10 | Valve Assembly | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wall_Thickness-Station |
Description | List of NPS valid wall thickness of Station Steel Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.068 | 0.068" | |
0.083 | 0.083" | |
0.088 | 0.088" | |
0.091 | 0.091" | |
0.109 | 0.109" | |
0.113 | 0.113" | |
0.12 | 0.120" | |
0.133 | 0.133" | |
0.134 | 0.134" | |
0.14 | 0.140" | |
0.145 | 0.145" | |
0.148 | 0.148" | |
0.154 | 0.154" | |
0.165 | 0.165" | |
0.18 | 0.180" | |
0.203 | 0.203" | |
0.216 | 0.216" | |
0.226 | 0.226" | |
0.237 | 0.237" | |
0.247 | 0.247" | |
0.25 | 0.250" | |
0.258 | 0.258" | |
0.277 | 0.277" | |
0.28 | 0.280" | |
0.281 | 0.281" | |
0.301 | 0.301" | |
0.307 | 0.307" | |
0.312 | 0.312" | |
0.322 | 0.322" | |
0.33 | 0.330" | |
0.337 | 0.337" | |
0.342 | 0.342" | |
0.355 | 0.355" | |
0.365 | 0.365" | |
0.375 | 0.375" | |
0.406 | 0.406" | |
0.432 | 0.432" | |
0.437 | 0.437" | |
0.5 | 0.500" | |
0.562 | 0.562" | |
0.593 | 0.593" | |
0.625 | 0.625" | |
0.656 | 0.656" | |
0.75 | 0.750" | |
0.812 | 0.812" | |
0.968 | 0.968" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 5 | Station Pipe | wallthickness |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Pump_Station |
Description | The Asset Types for the PipelineAssembly's Asset Group Pump Station |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pump station facility of unknown configuration. |
321 | Pump Station | A pump station facility of generic configuration. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 9 | Pump Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Regulator_Station |
Description | The Asset Types for the PipelineAssembly's Asset Group Regulator Station |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A regulator station of unknown configuration type. |
81 | Regulator Station | A regulator station of generic configuration |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 3 | Regulator Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Assembly_Town_Border_Station |
Description | The Asset Types for the PipelineAssembly's Asset Group Town Border Station |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A town border station of unknown type. |
161 | Town Border Station | A generic town border station. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 5 | Town Border Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Elbow |
Description | The Asset Types for the PipelineJunction's Asset Group Elbow |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An elbow fitting whose type is unknown. |
41 | Metal Elbow | An elbow fitting whose base material is metal. |
42 | Plastic Elbow | An elbow fitting whose base material is plastic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 2 | Elbow | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Compressor |
Description | The Asset Types for the PipelineDevice's Asset Group Compressor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A gas compressor of unknown asset type. |
161 | Electric Motor | A electric motor compressor uses electrically powered pistons to compress the gas. |
162 | Reciprocating Engine | A reciprocating engine compressor uses internal combustion engine to power pistons to compress the gas. |
163 | Turbine | A turbine compressor uses a series of rotating blades to compress the gas. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 10 | Compressor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Excess_Flow_Valve |
Description | The Asset Types for the PipelineDevice's Asset Group Excess Flow Valve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An excess flow valve of unknown asset type. |
1 | Automatic Reset | An excess flow valve with an automatic reset. |
2 | Manual Reset | An excess flow valve with a manual reset. |
3 | Breakaway Fitting |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 1 | Excess Flow Valve | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Actuator_Type |
Description | Valve Actuator Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Pneumatic - Single Acting | |
2 | Pneumatic - Double Acting | |
3 | Pneumatic - Vane | |
4 | Electrical | |
5 | Hydraulic |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | deviceactuatortype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Controllable_Tee |
Description | The Asset Types for the PipelineDevice's Asset Group Controllable Tee |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Controllable Tee of unknown type. |
241 | Controllable Tee | A generic Controllable Tee asset. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 12 | Controllable Tee | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Electro_Stop |
Description | The Asset Types for the PipelineJunction's Asset Group Electro Stop |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A electro stop fitting whose type is unknown. |
401 | Electro Stop | A generic electro stop fitting. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 11 | Electro Stop | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wall_Thickness-Riser |
Description | List of NPS valid wall thickness of Riser Steel Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.068 | 0.068" | |
0.083 | 0.083" | |
0.088 | 0.088" | |
0.091 | 0.091" | |
0.109 | 0.109" | |
0.113 | 0.113" | |
0.12 | 0.120" | |
0.133 | 0.133" | |
0.134 | 0.134" | |
0.14 | 0.140" | |
0.145 | 0.145" | |
0.148 | 0.148" | |
0.154 | 0.154" | |
0.165 | 0.165" | |
0.18 | 0.180" | |
0.203 | 0.203" | |
0.216 | 0.216" | |
0.226 | 0.226" | |
0.237 | 0.237" | |
0.247 | 0.247" | |
0.25 | 0.250" | |
0.258 | 0.258" | |
0.277 | 0.277" | |
0.28 | 0.280" | |
0.281 | 0.281" | |
0.301 | 0.301" | |
0.307 | 0.307" | |
0.312 | 0.312" | |
0.322 | 0.322" | |
0.33 | 0.330" | |
0.337 | 0.337" | |
0.342 | 0.342" | |
0.355 | 0.355" | |
0.365 | 0.365" | |
0.375 | 0.375" | |
0.406 | 0.406" | |
0.432 | 0.432" | |
0.437 | 0.437" | |
0.5 | 0.500" | |
0.562 | 0.562" | |
0.593 | 0.593" | |
0.625 | 0.625" | |
0.656 | 0.656" | |
0.75 | 0.750" | |
0.812 | 0.812" | |
0.968 | 0.968" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | wallthickness |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Decoupler |
Description | The Asset Types for the PipelineDevice's Asset Group Decoupler |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
921 | AC Decoupler | |
922 | DC Decoupler |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 53 | Decoupler | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Muffler_Material |
Description | List of valid materials of oil and gas mufflers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 1 | Pipe Muffler | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_HCA_Area_Type |
Description | List of valid types of High Consequence Areas |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
20 or More Persons | 20 or More Persons | |
DOT Class 3 | DOT Class 3 | |
DOT Class 4 | DOT Class 4 | |
Limited Mobility | Limited Mobility |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_HighConsequenceArea | hcatype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Flow_Valve |
Description | The Asset Types for the PipelineDevice's Asset Group Flow Valve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Flow Valve of unknown asset type. |
261 | Check | A check flow valve is a device which restricts the flow of the commodity to a single direction. These devices typically have a spring hinged flap which will automatically close if the commodity attempts to flow in the reverse direction. |
262 | Slam-shut | A slam-shut flow valve is a single use valve for manual operation to stop flow thru the pipeline. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 4 | Flow Valve | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Dehydration_Equipment |
Description | The Asset Types for the PipelineJunction's Asset Group Dehydration Equipment |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Dehydration equipment whose type is unknown. |
721 | Glycol Dehydration | Dehydration equipment which injects Glycol into the gas stream to remove water. |
722 | Methanol Dehydration | Dehydration equipment which inject Methanol into the gas stream to remove water. |
723 | Solid Absorption | Dehydration equipment which uses solid absorption to extract hydrates from the gas stream. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 19 | Dehydration Equipment | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anomaly_Type |
Description | List of identified anomaly |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
External Corrosion | External Corrosion | |
Internal Corrosion | Internal Corrosion | |
Dent | Dent | |
Gouge | Gouge | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_Anomaly | anomalytype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anomaly_Severity |
Description | List of valid rating of severity of identified anomaly |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
High | High | |
Medium | Medium | |
Low | Low |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_Anomaly | severity |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Coupon |
Description | The Asset Types for the PipelineJunction's Asset Group Coupon |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A coupon fitting whose type is unknown. |
681 | Coupon | A generic Coupon. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 18 | Coupon | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Material |
Description | List of ASTM F2897 Materials |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 37 |
# of Assignments | 28 |
Code | Description | Details |
---|---|---|
A | Plastic PE2406 | |
B | Plastic PE2708 | |
d | PE2708 Plus | |
C | Plastic PE3408 | |
D | Plastic PE3608 | |
E | Plastic PE3708 | |
F | Plastic PE3710 | |
G | Plastic PE4608 | |
H | Plastic PE4710 | |
e | PE4710 Plus | |
J | Plastic PVC | |
K | Plastic PA11 | |
L | Plastic PA12 | |
M | Steel | |
N | Stainless Steel | |
O | Cast Iron | |
P | Copper | |
Q | Brass | |
R | Malleable Iron | |
S | Ductile Iron | |
T | Reinforced Epoxy Resin | |
U | Nylon | |
V | Glass Filled Nylon | |
W | PE80 | |
X | Other | |
Y | PEX | |
Z | PE100 | |
0 | Steel Grade A | |
1 | Steel Grade B | |
2 | Steel Grade C | |
3 | Steel Grade X42 | |
4 | Steel Grade X46 | |
5 | Steel Grade X52 | |
6 | Steel Grade X56 | |
7 | Steel Grade X60 | |
8 | Steel Grade X65 | |
9 | Steel Grade X70 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Pipe_Access_Point |
Description | The Asset Types for the Structure Junction's Asset Group Pipe Access Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pipe Access Point of unknown type. |
231 | Manhole Cover | The identified location of the manhole cover to access the underground structure. |
232 | Door | The identified location of the door to access the structure. |
233 | Grate | The identified location of the grate to access the underground structure. |
234 | Hand Hole | The identified location of the hand hole to access the underground structure. |
235 | Lid | The identified location of the lid to an undergrounod structure. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 10 | Pipe Access Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Coupling |
Description | The Asset Types for the PipelineJunction's Asset Group Coupling |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A coupling of unknown type. |
1 | Metal Coupling | A coupling fitting whose primary material is metallic. |
2 | Plastic Coupling | A coupling fitting whose primary material is plastic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 1 | Coupling | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Connection_Type |
Description | Method used to connect a device to a pipe |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Thread | Thread | |
Flange | Flange | |
Fuse | Fuse | |
Weld | Weld |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | regulatorconnection |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Grounding_Point |
Description | The Asset Types for the PipelineDevice's Asset Group Grounding Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
961 | Grounding Point |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 54 | Grounding Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Junction_Material_Specification |
Description | List of material specification for steel pipe fittings |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 23 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
ASTM A105 | ASTM A105 | |
ASTM A234 | ASTM A234 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Sleeve |
Description | The Asset Types for the StructureJunction's Asset Group Sleeve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe sleeve of unknown type. |
131 | Damage Repair | A pipe sleeve installed to reinforce a pipe damaged but not leaking. |
132 | Leak Repair | A pipe sleeve installed to repair a leaking pipe. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 8 | Pipe Sleeve | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Lamp |
Description | The Asset Types for the PipelineDevice's Asset Group Lamp |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A lamp of unknown type. |
121 | Lamp | A lamp of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 9 | Lamp | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Close_Direction |
Description | The close direction of a valve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Counter Clockwise | |
1 | Clockwise |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | adddetails |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Union_Manufacture_Component |
Description | |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
U1 | Non-insulated | |
UX | Insulated | |
C0 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 23 | Union | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Pump |
Description | The Asset Types for the PipelineDevice's Asset Group Pump |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pump of unknown asset type. |
401 | Booster | A booster pump provides additional pressure to the flow of the hazardous liquid |
402 | Primary | A primary pump provides the majority of the pressure to the flow of the hazardous liquid. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 18 | Pump | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Survey_Type |
Description | List of the valid leak survey types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Aerial | Aerial | |
Mobile Truck | Mobile Truck | |
Walking | Walking | |
Bridge | Bridge | |
Pre Pave | Pre Pave | |
Public Building | Public Building | |
Special | Special | |
Non-Survey | Non-Survey | |
Business District | Business District | |
Cast Iron | Cast Iron | |
Transmission | Transmission | |
Feeder | Feeder |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakSurveyArea | surveytype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Line_Stopper |
Description | The Asset Types for the PipelineDevice's Asset Group Line Stopper |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A short stop of unknown asset type. |
461 | Line Stopper | A generic Short Stop asset. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 13 | Line Stopper | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Meter |
Description | The Asset Types for the PipelineDevice's Asset Group Meter |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A meter of unknown asset type. |
41 | Custody Transfer | A custody transfer meter is the measuring device of the volume received from another pipe organization. A custody transfer meter is typically located in a facility such as a compressor station or a regulator station. |
42 | Customer | A customer meter is the measuring device of the volume of the commodity consumed by an individual customer. A customer meter is typically located in a meter setting. |
43 | Utility | A utility meter is the measuring device of the volume of gas or hazardous liquid at a facility. A utility meter is typically located in a facility such as a regulator station or compressor station. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 2 | Meter | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Valve_Box |
Description | The Asset Types for the StructureJunction's Asset Group Valve Box |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe box of unknown type. |
61 | Curb Box | A buried container on a service line containing a shutoff valve. |
62 | Curb Box with Stationary Rod | A buried container on a service line containing a shutoff valve, and incudes a upward extending rod. |
63 | Roadway | A buried container, specifically designed for installation within a road right-of-way. |
64 | Valve Box | A buried container containing a pipe valve other than a curb box. |
65 | Meter Box | A buried container containing a meter. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 7 | Pipe Box | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Pressure_Monitoring_Device |
Description | The Asset Types for the PipelineDevice's Asset Group Pressure Monitoring Device |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pressure monitoring device of unknown asset type. |
81 | Pressure Monitoring Device | A generic pressure monitoring device asset. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 8 | Pressure Monitoring Device | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Rectifier |
Description | The Asset Types for the Device Asset Group Rectifier |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | a cathodic protection rectifier of unknown asset type. |
941 | Rectifier | A generic rectifier asset. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 51 | Rectifier | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Regulator |
Description | The Asset Types for the PipelineDevice's Asset Group Regulator |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Regulator of unknown asset type. |
521 | Regulator | A generic regulator device. |
522 | Customer Regulator | A regulator installed as part of a meter set for a customer meter |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 19 | Regulator | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Expansion_Joint |
Description | The Asset Types for the PipelineJunction's Asset Group Expansion Joint |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An expansion joint whose type is unknown. |
121 | Expansion Joint | A generic classification of expansion joints. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 4 | Expansion Joint | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Relief_Valve |
Description | The Asset Types for the PipelineDevice's Asset Group Relief Valve |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Relief Valve of unknown asset type. |
21 | Blow Off | A relief valve which releases natural gas to the atmosphere when a set pressure is exceeded. |
22 | Flare | |
23 | Over Pressure Protection | |
24 | Vacuum Pressure Protection | |
25 | Over Pressure and Vacuum Pressure Protection |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 5 | Relief Valve | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Scrubber |
Description | The Asset Types for the PipelineDevice's Asset Group Scrubber |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Scrubber of unknown type. |
561 | Scrubber | A scrubber is a device designed to remove harmful materials from gas. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 20 | Scrubber | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Test_Point |
Description | The Asset Types for the Device's Asset Group Test Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A cathodic protection test point of unknown asset type. |
981 | Above Ground | A rectifier located above the ground surface. |
982 | Buried | A rectifier located below the ground surface. |
983 | On Post | A rectifier located above the ground surface and installed on a post. |
984 | Pipeline Marker | A rectifier located above the ground surface and installed on a pipeline marker. |
985 | Service Line | A rectifier installed on a service line. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 52 | Test Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Outside_Diameter-Station |
Description | List of NPS outside diameter for Station Steel Pipe Material |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.54 | 0.540" | |
0.675 | 0.675" | |
0.84 | 0.840" | |
1.05 | 1.050" | |
1.315 | 1.315" | |
1.66 | 1.660" | |
1.9 | 1.900" | |
2.375 | 2 3/8" | |
2.875 | 2 7/8" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
5.563 | 5.563 | |
6.625 | 6 5/8" | |
7.625 | 7 5/8" | |
8.625 | 8 5/8" | |
9.625 | 9 5/8" | |
10.75 | 10 3/4" | |
12.75 | 12 3/4" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
46 | 46" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" | |
88 | 88" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 5 | Station Pipe | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Service_Stations |
Description | The Asset Types for the PipelineDevice's Asset Group Service Stations |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
31 | Metered | |
32 | Metered and Regulated |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 21 | Service Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Strainer |
Description | The Asset Types for the PipelineDevice's Asset Group Strainer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | a strainer of unknown asset type. |
442 | Strainer | A device designed to remove larger particles suspended in gas. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 6 | Strainer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Hanger_Manufacturer |
Description | List of valid manufacturers of oil and gas pipe hangers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 4 | Pipe Hanger | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Riser_Pipe_Type |
Description | List of ASTM F-2897 valid Riser Pipe Specification |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
10 | Other Pipe | |
13 | Casing Pipe | |
1A | Seamless Line Pipe, API 5L, PSL1, Single Coat Pipe | |
1B | Seamless Line Pipe, API 5L, PSL1, Dual Coat Pipe | |
1C | Seamless Line Pipe, API 5L, PSL2, Single Coat Pipe | |
1D | Seamless Line Pipe, API 5L, PSL2, Dual Coat Pipe | |
1E | Electric Resistance Weld, API 5L, PSL1, Single Coat Pipe | |
1F | Electric Resistance Weld, API 5L, PSL1, Dual Coat Pipe | |
1G | Electric Resistance Weld, API 5L, PSL2, Single Coat Pipe | |
1H | Electric Resistance Weld, API 5L, PSL2, Dual Coat Pipe | |
1J | Seamless and Welded ASTM A53/53M Pipe | |
1K | Seamless Carbon Steel ASTM A106 Pipe |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Device_Wellhead_Source_Flange |
Description | The Asset Types for the PipelineDevice's Asset Group Wellhead Source Flange |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Wellhead Source Flange of unknown asset type. |
201 | Flange | A Wellhead Source Flange of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 11 | Wellhead Source Flange | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Corrosion_Condition |
Description | List of valid current states of the condition of corrosion |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Non-Metallic | Non-Metallic | |
None | None | |
Light | Light | |
Moderate | Moderate | |
Heavy | Heavy |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExposedPipeInspect | corrosioncondition |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Connection_Point |
Description | The Asset Types for the PipelineJunction's Asset Group Connection Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A connection point fitting whose type is unknown. |
801 | Connection Point | A generic Connection Point component. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 21 | Connection Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Coating_Condition |
Description | List of valid current states of the gas asset coating |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
No Coating | No Coating | |
Completely Disbonded | Completely Disbonded | |
Completely Intact | Completely Intact | |
Extensive Disbonding | Extensive Disbonding | |
Isolated Disbonding | Isolated Disbonding |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExposedPipeInspect | coatingcondition |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_End_Cap |
Description | The Asset Types for the PipelineJunction's Asset Group End Cap |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An end cap fitting whose type is unknown. |
81 | Metal End Cap | An end cap fitting whose base material is metal. |
82 | Plastic End Cap | An end cap fitting whose base material is plastic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 3 | End Cap | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Drip_Model |
Description | List of valid models of gas drips |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 20 | Drip | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Insulation_Junction |
Description | The Asset Types for the Junction's Asset Group Insulation Junction |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A insulation junction fitting whose type is unknown. |
941 | Flange Insert | A insulation junction fitting whose primary material is flange. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 51 | Insulation Junction | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Odorizer |
Description | The Asset Types for the PipelineJunction's Asset Group Odorizer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | An odorizer whose type is unknown. |
641 | Absorption Bypass | An odorizer whose primary material is absorption. |
642 | Injection Pump | An odorizer whose primary material is injection. |
643 | Pulse | An odorizer whose primary material is pulse. |
644 | Rural Tap Odorizer | An odorizer whose primary material is rural. |
645 | Wick | An odorizer whose primary material is wick. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 17 | Odorizer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Olet |
Description | The Asset Types for the PipelineJunctions's Asset Group Olet |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
31 | Weldolet | |
32 | Threadolet | |
33 | Sockolet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 26 | Olet | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Pipe_Bend |
Description | The Asset Types for the PipelineJunction's Asset Group Pipe Bend |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe bend fitting whose type is unknown. |
51 | Hot Bend | A pipe bend fitting of generic type. |
52 | Cold Bend | |
53 | Miter Bend | |
54 | Field Bend | |
55 | Wrinkle Bend | |
56 | Factory Bend |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 30 | Pipe Bend | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Flow |
Description | List of valid units of measure of the volumetric flow |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
32 | Cubic Feet/sec | |
31 | Cubic Inches/sec | |
134 | Cubic Meters/sec | |
132 | Cubic Centimeters/sec |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 3 | Regulator Station | designcapacityunits |
main.PipelineAssembly | 5 | Town Border Station | designcapacityunits |
main.PipelineDevice | 19 | Regulator | usagerateunits |
main.PipelineJunction | 0 | Unknown | flowcapacityunits |
main.PipelineJunction | 14 | Tank | flowcapacityunits |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Plastic_Fusion |
Description | The Asset Types for the PipelineJunction's Asset Group Plastic Fusion |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A plastic fusion fitting whose type is unknown. |
441 | Plastic Fusion | A plastic fusion fitting of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 12 | Plastic Fusion | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_End_Connection_Manufacturer |
Description | List of valid manufacturers of oil and gas pipe casing end connections |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 5 | Pipe End Connection | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Plug |
Description | The Asset Types for the PipelineJunction's Asset Group Plug |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A plug fitting whose type is unknown. |
181 | Test Plug | A plug of type test plug. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 24 | Plug | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Reducer |
Description | The Asset Types for the PipelineJunction's Asset Group Reducer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A reducer fitting whose type is unknown. |
201 | Metal Reducer | A reducer fitting whose primary material is metallic. |
202 | Plastic Reducer | A reducer fitting whose primary material is plastic. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 6 | Reducer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Screw |
Description | The Asset Types for the PipelineJunction's Asset Group Screw |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A screw fitting whose type is unknown. |
361 | Screw | A generic screw fitting. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 10 | Screw | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Tap |
Description | The Asset Types for the PipelineJunction's Asset Group Tap |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
841 | Cold Tap | |
842 | Hot Tap | |
843 | Full Encirclement |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 25 | Tap | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Tee |
Description | The Asset Types for the PipelineJunction's Asset Group Tee |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A tee fitting whose primary material is unknown. |
241 | Metal 3-Way | A tee fitting whose primary material is metal and connects 3 pipe segments. |
242 | Metal 4-Way | A tee fitting whose primary material is metal and connects 4 pipe segments. |
243 | Plastic 3-Way | A tee fitting whose primary material is plastic and connects 3 pipe segments. |
244 | Plastic 4-Way | A tee fitting whose primary material is plastic and connects 4 pipe segments. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 7 | Tee | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Transition |
Description | The Asset Types for the PipelineJunction's Asset Group Transition |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A transition fitting whose primary material is unknown. |
281 | Transition | A generic transition fitting. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 8 | Transition | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Remote_Failure_Type |
Description | Valve Remote Failure Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Fail to Open | |
2 | Fail to Close | |
3 | Pneumatic – Vane | |
4 | Electrical | |
5 | Hydraulic |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | remotedevicefailtype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Union |
Description | The Asset Types for the PipelineJunction's Asset Group Union |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A union fitting whose type is unknown. |
341 | Metal Union | A union fitting whose primary material is metal. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 23 | Union | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Muffler_Manufacturer |
Description | List of valid manufacturers of gas compressor station mufflers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 1 | Pipe Muffler | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Weld |
Description | The Asset Types for the PipelineJunction's Asset Group Weld |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A weld fitting whose type is unknown. |
321 | Weld | A weld of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 9 | Weld | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Valve_Manufacture_Component |
Description | List of ASTM F-2897 manufacturer specified types of valves |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
V0 | Other Valve | |
V1 | Ball Valve | |
V2 | Butterfly Valve | |
V3 | Check Valve | |
V4 | Relief Valve | |
V5 | Gas Valve | |
V6 | Needle Valve | |
V7 | Plug Valve | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 4 | Rural Tap | shutoffvalvetype |
main.PipelineDevice | 3 | Controllable Valve | manufacturecomponent |
main.PipelineDevice | 4 | Flow Valve | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Reducer_Manufacture_Component |
Description | List of ASTM F-2897 Reducer Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
70 | Other Reducer | |
71 | Butt fusion Reducer | |
72 | Socket fusion Reducer | |
73 | Electrofusion Reducer | |
74 | Mechanical compression or nut follower Reducer | |
75 | Mechanical stab Reducer | |
76 | Mechanical Interference fit Reducer | |
77 | Welded Reducer | |
78 | Threaded Reducer | |
79 | Fabricated Reducer | |
7A | Butt Fusion with EFV | |
7B | Socket Fusion with EFV | |
7C | Electrofusion with EFV | |
7D | Mechanical compression or nut follower with EFV | |
7E | Mechanical Stab with EFV | |
7F | Mechanical interference fit with EFV | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 6 | Reducer | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Junction_Wire_Junction |
Description | The Asset Types for the Junction's Asset Group Wire Junction |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A wire junction fitting whose type is unknown. |
901 | Bond Junction | Bond junction connects a wire to a metallic asset |
902 | Test Lead | Test Lead is a wire junction at a test point |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 50 | Wire Junction | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Bonding_Line |
Description | The Asset Types for the PipelineLine's Asset Group Bonding Line |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A bonding line whose type is unknown. |
961 | Wire | A bonding line whose type is wire. |
962 | Strap | A bonding fitting whose type is strap. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 50 | Bonding Line | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_CP_Cable |
Description | The Asset Types for the PipelineLine's Asset Group CP Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A rectifier cable whose type is unknown. |
941 | Rectifier Cable | A rectifier cable of generic type. |
942 | Decoupler Cable |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 52 | CP Cable | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Riser |
Description | List of Valid Nominal Diameter Size for Riser Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Customer_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Customer Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
7 | Plastic ABS | Plastic pipe made from Acrylonitrile-Butadiene Styrene plastic. |
8 | Plastic Other | Plastic pipe that is not made from ABS, PE, or PVC. |
9 | Plastic PE | Plastic pipe made from polyethylene plastic. |
10 | Plastic PVC | Plastic pipe made from polyvinyl chloride plastic. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 6 | Customer Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Distribution_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Distribution Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
5 | Copper | Pipe made from the refined mineral Copper (Cu). |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
7 | Plastic ABS | Plastic pipe made from Acrylonitrile-Butadiene Styrene plastic. |
8 | Plastic Other | Plastic pipe that is not made from ABS, PE, or PVC. |
9 | Plastic PE | Plastic pipe made from polyethylene plastic. |
10 | Plastic PVC | Plastic pipe made from polyvinyl chloride plastic. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 2 | Distribution Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Gathering_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Gathering Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
7 | Plastic ABS | Plastic pipe made from Acrylonitrile-Butadiene Styrene plastic. |
8 | Plastic Other | Plastic pipe that is not made from ABS, PE, or PVC. |
9 | Plastic PE | Plastic pipe made from polyethylene plastic. |
10 | Plastic PVC | Plastic pipe made from polyvinyl chloride plastic. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 4 | Gathering Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Linear_Anode |
Description | The Asset Types for the PipelineLine's Asset Group Linear Anode |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
981 | Horizontal Anode | |
982 | Ribbon |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 53 | Linear Anode | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Pressure_Sensor_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Pressure Sensor Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 15 | Pressure Sensor Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Riser_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Riser Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Service_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Service Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
5 | Copper | Pipe made from the refined mineral Copper (Cu). |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
7 | Plastic ABS | Plastic pipe made from Acrylonitrile-Butadiene Styrene plastic. |
8 | Plastic Other | Plastic pipe that is not made from ABS, PE, or PVC. |
9 | Plastic PE | Plastic pipe made from polyethylene plastic. |
10 | Plastic PVC | Plastic pipe made from polyvinyl chloride plastic. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Services |
Description | List of Valid Nominal Diameter Size for Service Lines |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Station_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Station Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 5 | Station Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Storage_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Storage Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bare Steel | |
2 | Cast Iron | |
3 | Coated Steel | |
4 | Composite | |
5 | Copper | |
6 | Ductile Iron | |
7 | Plastic ABS | |
8 | Plastic Other | |
9 | Plastic PE | |
10 | Plastic PVC | |
11 | Reconditioned Cast Iron | |
12 | Wrought Iron |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 8 | Storage Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Test_Lead_Wire |
Description | The Asset Types for the PipelineLine's Asset Group Test Lead Wire |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A test lead wire whose coating is of unknown color. |
901 | Aqua | A test lead wire whose coating color is aqua. |
902 | Blue | A test lead wire whose coating color is blue. |
903 | Forest | A test lead wire whose coating color is forest. |
904 | Green | A test lead wire whose coating color is Green. |
905 | Lavender | A test lead wire whose coating color is Lavender. |
906 | Orange | A test lead wire whose coating color is Orange. |
907 | Pink | A test lead wire whose coating color is Pink. |
908 | Red | A test lead wire whose coating color is Red. |
909 | Yellow | A test lead wire whose coating color is Yellow. |
910 | Purple | A test lead wire whose coating color is Purple. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 51 | Test Lead Wire | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Line_Transmission_Pipe |
Description | The Asset Types for the PipelineLine's Asset Group Transmission Pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe segment whose material composition cannot be verified. |
1 | Bare Steel | Steel pipe that is not coated with a hot or cold applied wrapper. |
2 | Cast Iron | Pipe made from iron with a carbon content greater than 2%. |
3 | Coated Steel | Steel pipe that has been covered with a hot or cold applied wrapper. |
4 | Composite | Pipe that is constructed of two or more dissimilar materials. |
6 | Ductile Iron | Pipe made from iron with a less brittle type of graphite carbon. |
11 | Reconditioned Cast Iron | Cast iron pipe that has been rehabilitated. |
12 | Wrought Iron | Pipe made from iron with a carbon content less than 2%. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 3 | Transmission Pipe | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Boundary_Cathodic |
Description | The Asset Types for the StructureBoundary's Asset Group Cathodic |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
101 | Grounding Mat |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 4 | Cathodic | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | BooleanSymbolValue |
Description | Valid values are Yes and No. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Yes | |
0 | No |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Boundary_Station_Structure |
Description | The Asset Types for the StructureBoundary's Asset Group Station Structure |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe station of unknown type. |
1 | Station Structure | A generic pipe structure facility. |
2 | Town Border Station | A pipe station housing a town border pressure reducing facility. |
3 | District Regulator Station | A pipe station housing a pressure reducing facility managed by the utility organization |
4 | Commercial Regulator Station | A pipe station housing a pressure reducing facility managed by a non-utility organization |
5 | Compressor Station | A pipe station housing a pressure increasing facility. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 1 | Pipe Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Anchor |
Description | The Asset Types for the StructureJunction's Asset Group Anchor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe anchor of unknown type. |
41 | Anchor | A generic anchor component. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 2 | Pipe Anchor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_End_Connection |
Description | The Asset Types for the StructureJunction's Asset Group End Connection |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe casing end connection of unknown type. |
161 | End Seals | The seal at the end of a pipe casing to contain the pipe casing fill. |
162 | Skids & Straps | |
163 | Spacers | An insert in to a pipe casing to maintain spacing between the pipe casing and the inserted pipe. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 5 | Pipe End Connection | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Pipe_Hanger |
Description | The Asset Types for the StructureJunction's Asset Group Pipe Hanger |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe hanger of unknown type. |
121 | Constant Spring | A support structure used provide a constant tension. |
122 | Rigid | A support structure used to restrict the movement of the hung pipe segment. |
123 | Variable Spring | A support structure used to allow limited movement in specified directions. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 4 | Pipe Hanger | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Pipe_Support |
Description | The Asset Types for the StructureJunction's Asset Group Pipe Support |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A pipe support of unknown type. |
81 | Pipe Stand | A support structure used to secure a pipeline asset. |
82 | Roller | A support structure used to uphold a pipe segment but allow for lateral movement via thermal expansion/contraction. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 3 | Pipe Support | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_End_Connection_Material |
Description | List of valid materials of oil and gas end connections |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 5 | Pipe End Connection | material |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Junction_Vault |
Description | The Asset Types for the StructureJunction's Asset Group Vault |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pipe Vault of unknown type. |
201 | Vault | A Pipe vault of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 6 | Pipe Vault | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Coating_Type |
Description | List of valid types of coating applied to gas pipe |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 35 |
# of Assignments | 33 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3M Tape | 3M Tape | |
Asbestos Felt | Asbestos Felt | |
Asphalt | Asphalt | |
Blue Gard | Blue Gard | |
Coal Tar | Coal Tar | |
Coal Tar Enamel | Coal Tar Enamel | |
Cold Tape | Cold Tape | |
Composite | Composite | |
Concrete | Concrete | |
Enamel | Enamel | |
Epoxy | Epoxy | |
Extruded Asphalt | Extruded Asphalt | |
Extruded Polyethylene | Extruded Polyethylene | |
Felt Wrap | Felt Wrap | |
Flakeline | Flakeline | |
Flex Clad | Flex Clad | |
Fusion Bonded Epoxy | Fusion Bonded Epoxy | |
Galvanized | Galvanized | |
Glass Filled Polyester | Glass Filled Polyester | |
Grease | Grease | |
Hot Tape | Hot Tape | |
Hysol | Hysol | |
Mill Wrap | Mill Wrap | |
Neoprene | Neoprene | |
None | None | |
Other | Other | |
Paint | Paint | |
Paper | Paper | |
Primer | Primer | |
Rock Jacket | Rock Jacket | |
Scotch Wrap | Scotch Wrap | |
Tar | Tar | |
Wax | Wax | |
Yellow Jacket | Yellow Jacket |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Pipeline_Structure_Line_Casing |
Description | The Asset Types for the StructureLine's Asset Group Casing |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pipe Casing of unknown type. |
1 | Casing | A generic pipe casing. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 1 | Pipe Casing | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Boundary_Pipeline_Pipe_Vault |
Description | The Asset Types for the Structure Boundary's Asset Group Pipe Vault |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pipe Vault of unknown type. |
81 | Vault Boundary | A Pipe Vault of generic type. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 2 | Pipe Vault | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Bonded_Insulated |
Description | Values to indicate if a feature is bonded or insulated |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 66 |
Code | Description | Details |
---|---|---|
1 | Bonded | |
2 | Insulated |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Heat |
Description | List of valid units of measure for heat generation |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
201 | BTU/Hour | |
202 | Watt | |
203 | Kilowatt |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 0 | Unknown | heatingcapacityunits |
main.PipelineJunction | 15 | Line Heater | heatingcapacityunits |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Anode_Manufacturer |
Description | Manufacturer of anodes |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
CR | Corrpro | |
JN | Jennings | |
KD | Katradis | |
MC | Matcor |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 50 | Anode | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Anode_Material |
Description | List of materials used for Anodes |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
11 | Carbon-Graphite | |
12 | Cast Iron | |
13 | Galvanic | |
14 | Graphite | |
15 | Magnesium | |
16 | Magnesium (High Grade B) | |
17 | Magnesium (High Potential) | |
18 | Mixed Metal Oxide | |
19 | Scrap Steel | |
20 | Zinc |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 50 | Anode | material |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Anode_Weight |
Description | List of valid types of sizes by weight for anodes |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.75 | 3/4 lb | |
1 | 1 lb | |
3 | 3 lb | |
5 | 5 lb | |
9 | 9 lb | |
17 | 17 lb | |
20 | 20 lb | |
32 | 32 lb | |
48 | 48 lb | |
1.5 | 1 1/2 lb |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 50 | Anode | weight |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Customer |
Description | List of Valid Nominal Diameter Size for Customer Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 6 | Customer Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | CP_ASTM_Anode_Manufacture_Component |
Description | List of ASTM F-2897 Anode Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
A0 | Other Anode | |
A1 | Cast Iron Anode | |
A2 | Graphite Anode | |
A3 | Magnesium Anode | |
A4 | Zinc Anode | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 50 | Anode | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Rectifier_Manufacturer |
Description | List of manufacturers for rectifiers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
U | Unknown | |
GD | Goodall | |
KT | Kerotest | |
RW | Rockwell | |
RL | R.W. Lyall |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 51 | Rectifier | manufacturer |
main.PipelineJunction | 16 | Cooling System | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Test_Point_Wire_Count |
Description | Number of wires on a test point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | 1 | |
2 | 2 | |
3 | 3 | |
4 | 4 | |
5 | 5 | |
6 | 6 | |
7 | 7 | |
8 | 8 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 52 | Test Point | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Traceability |
Description | Valid cathodic protection status values |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 130 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Traceable | |
2 | Not Traceable |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ILI_Survey_Marker_Type |
Description | List of valid types of ground reference markers for inline inspections |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
AGR Timer Box | AGR Time Box | |
AGR Valve | AGR Valve | |
Monument | Monument | |
Crossing | Crossing | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ILIGroundRefMarkers | markertype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Pressure_Sensor_Pipe_Material |
Description | List of ASTM F-2897 Material for Pressure Sensor Pipe Grade |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 22 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
d | PE2708 Plus | |
e | PE4710 Plus | |
W | PE80 | |
Z | PE100 | |
Y | PEX | |
M | Steel | |
N | Stainless Steel | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 15 | Pressure Sensor Pipe | material |
Key | Value |
---|---|
Owner | |
Domain Name | CP_Wire_Gauge |
Description | List of valid sizes used for wire/cable gauges |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | 4 | |
8 | 8 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 50 | Bonding Line | outsidediameter |
main.PipelineLine | 51 | Test Lead Wire | outsidediameter |
main.PipelineLine | 52 | CP Cable | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Gas_Valve_Condition |
Description | Valid valve box conditions |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Good | |
2 | Fair | |
3 | Poor |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ValveInspection | valveboxcond |
Key | Value |
---|---|
Owner | |
Domain Name | HorizontalAlignment |
Description | Valid horizontal symbol alignment values. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Left | |
1 | Center | |
2 | Right | |
3 | Full |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Combined |
Description | Bitwise combination of lifecycle states for subnetwork management |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 6 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Proposed | |
2 | Approved | |
3 | Proposed and Approved | |
4 | Under Construction | |
6 | Approved and Under Construction | |
7 | Proposed, Approved and Under Construction | |
8 | In Service | |
12 | In Service and Under Construction | |
14 | In Service, Under Construction, and Approved | |
15 | In Service, Under Construction, Approved and Proposed | |
16 | To Be Retired | |
24 | In Service and To Be Retired | |
32 | Abandoned | |
64 | Retired | |
128 | Removed | |
256 | Out of Service |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | lifecyclestatus | ||
main.StructureLine | lifecyclestatus | ||
main.PipelineAssembly | lifecyclestatus | ||
main.StructureJunction | lifecyclestatus | ||
main.PipelineDevice | lifecyclestatus | ||
main.PipelineLine | lifecyclestatus |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Dam_Damage_Type |
Description | List of valid types of damages to the gas pipe system caused by excavation |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Dent | Dent | |
Gauge | Gauge | |
Line Cut | Line Cut | |
Puncture | Puncture | |
Pulled | Pulled | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | damagetype |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Status |
Description | Valid lifecycle states for the assets. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 93 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Proposed | |
2 | Approved | |
4 | Under Construction | |
8 | In Service | |
16 | To Be Retired | |
32 | Abandoned | |
64 | Retired | |
128 | Removed | |
256 | Out of Service |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Outside_Diameter-Pressure_Sensor |
Description | List of NPS outside diameter for Pressure Sensor Pipe Material |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.54 | 0.540" | |
0.675 | 0.675" | |
0.84 | 0.840" | |
1.05 | 1.050" | |
1.315 | 1.315" | |
1.66 | 1.660" | |
1.9 | 1.900" | |
2.375 | 2 3/8" | |
2.875 | 2 7/8" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
5.563 | 5.563 | |
6.625 | 6 5/8" | |
7.625 | 7 5/8" | |
8.625 | 8 5/8" | |
9.625 | 9 5/8" | |
10.75 | 10 3/4" | |
12.75 | 12 3/4" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
46 | 46" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" | |
88 | 88" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 15 | Pressure Sensor Pipe | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Alignment_Sheet_Type |
Description | Pipeline List of valid types of map sheets in the alignment sheet featureclass |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Class Location | Class Location | |
Construction | Construction | |
Detail Sheet | Detail Sheet | |
Engineering | Engineering | |
Integrity | Integrity | |
New Construction | New Construction |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_AlignmentSheet | sheettype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anchor_Manufacturer |
Description | List of valid manufacturers of oil and gas anchors or river weights |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 2 | Pipe Anchor | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wall_Thickness-Pressure_Sensor |
Description | List of NPS valid wall thickness of Pressure Sensor Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.068 | 0.068" | |
0.083 | 0.083" | |
0.088 | 0.088" | |
0.091 | 0.091" | |
0.109 | 0.109" | |
0.113 | 0.113" | |
0.12 | 0.120" | |
0.133 | 0.133" | |
0.134 | 0.134" | |
0.14 | 0.140" | |
0.145 | 0.145" | |
0.148 | 0.148" | |
0.154 | 0.154" | |
0.165 | 0.165" | |
0.18 | 0.180" | |
0.203 | 0.203" | |
0.216 | 0.216" | |
0.226 | 0.226" | |
0.237 | 0.237" | |
0.247 | 0.247" | |
0.25 | 0.250" | |
0.258 | 0.258" | |
0.277 | 0.277" | |
0.28 | 0.280" | |
0.281 | 0.281" | |
0.301 | 0.301" | |
0.307 | 0.307" | |
0.312 | 0.312" | |
0.322 | 0.322" | |
0.33 | 0.330" | |
0.337 | 0.337" | |
0.342 | 0.342" | |
0.355 | 0.355" | |
0.365 | 0.365" | |
0.375 | 0.375" | |
0.406 | 0.406" | |
0.432 | 0.432" | |
0.437 | 0.437" | |
0.5 | 0.500" | |
0.562 | 0.562" | |
0.593 | 0.593" | |
0.625 | 0.625" | |
0.656 | 0.656" | |
0.75 | 0.750" | |
0.812 | 0.812" | |
0.968 | 0.968" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 15 | Pressure Sensor Pipe | wallthickness |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Hanger_Material |
Description | List of valid materials of oil and gas pipe hangers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
M | Steel | |
N | Stainless Steel | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 4 | Pipe Hanger | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anchor_Material |
Description | List of valid materials of oil and gas anchors or river weights |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Concrete |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 2 | Pipe Anchor | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Strainer_Device_Type |
Description | List of valid type of manufacturer models of strainers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Filter | Filter | |
Strainer | Strainer |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StrainerInspect | devicetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Natural |
Description | List of the types of valid causes of gas leaks due to Natural Forces |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Lightning | Lightning | |
Soil Erosion | Soil Erosion | |
Flooding | Flooding | |
High Winds | High Winds | |
Tree Roots | Tree Roots | |
Animal | Animal | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 6 | Natural Forces | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anchor_Model |
Description | List of valid manufacturers models of oil and gas anchors or river weights |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 2 | Pipe Anchor | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Method_Detected |
Description | List of the types of methods used to detect leaking gas |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 12 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Customer Reported | Customer Reported | |
Leak Survey | Leak Survey | |
Odor | Odor | |
Sight | Sight | |
Sound | Sound | |
Vegetation | Vegetation |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anomaly_Priority |
Description | List of valid priority status for identified anomaly |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Immediate | Immediate | |
Scheduled | Scheduled | |
Monitored | Monitored |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_Anomaly | priority |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anomaly_Remediation |
Description | List of valid remediations for identified anomaly |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Composite Sleeve | Composite Sleeve | |
Coupling Reinforcement Sleeve | Coupling Reinforcement Sleeve | |
Full Encirclement Welded Split Sleeve | Full Encirclement Welded Split Sleeve | |
Pipe Cutout | Pipe Cutout | |
Saddle Reinforcement Sleeve | Saddle Reinforcement Sleeve | |
Weld Reinforcement Sleeve | Weld Reinforcement Sleeve |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_Anomaly | recommendedremediation |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Survey_Status |
Description | List of the valid leak survey status |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Assigned | Assigned | |
In Progress | In Progress | |
Completed | Completed | |
Reassign | Reassign | |
No Access | No Access | |
Not Assigned | Not Assigned |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakSurveyArea | surveystatus |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Anomaly_Status |
Description | List of states of identified anomaly |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Previously Excavated | Previously Excavated | |
Proposed | Proposed | |
Postponed | Postponed | |
Pending Review | Pending Review | |
In Progress | In Progress | |
Scheduled | Scheduled |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_Anomaly | anomalystatus |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Coupling_Manufacture_Component |
Description | List of ASTM F-2897 types of Coupling Manufacture Models |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 25 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
20 | Other Coupling | |
21 | Socket Fusion Coupling | |
22 | Socket Fusion with EFV Coupling | |
23 | Electrofusion Coupling | |
24 | Electrofusion with EFV Coupling | |
25 | Mechanical Compression or nut follower Coupling | |
26 | Mechanical Compression or nut follower Coupling with EFV | |
27 | Mechanical stab Coupling | |
28 | Mechanical stab with EFV Coupling | |
29 | Mechanical interference fit Coupling | |
2A | Mechanical interference fit with EFV Coupling | |
2B | Welded Coupling | |
2C | Threaded Coupling | |
2D | Flanged Coupling | |
30 | Other Adapter Coupling | |
31 | Compression by Male pipe thread Adapter Coupling | |
32 | Compression by femail pipe thread Adapter Coupling | |
33 | Compression by butt fusion Adapter Coupling | |
34 | Compression by butt welded Adapter Coupling | |
35 | Compression by solvent welded Adapter Coupling | |
36 | Stab by male pipe thread Adapter Coupling | |
37 | Stab by female pipe thread Adapter Coupling | |
38 | Stab by solvent welded Adapter Coupling | |
39 | Compression by stab Adapter Coupling | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 1 | Coupling | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Crossing_Wired_Utility |
Description | Type of wired utility crossing the pipeline |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Telecommunication | Telecommunication | |
Fiber | Fiber | |
Electric Overhead | Electric Overhead | |
Electric Buried | Electric Buried | |
Cable | Cable | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeCrossing | 2 | Wire Utility | crossingfeaturetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_EFV_Manufacture_Component |
Description | List of ASTM F-2897 types of EFV Manufacture Models |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 26 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
22 | Coupling Socket fusion with EFV | |
26 | Coupling Mechanical compression or nut follower with EFV | |
28 | Coupling Mechanical stab with EFV | |
2A | Coupling Mechanical interference fit with EFV | |
EF | Excess Flow Valve | |
7A | Reducer Butt Fusion with EFV | |
7B | Reducer Socket Fusion with EFV | |
7C | Reducer Electrofusion with EFV | |
7D | Reducer Mechanical interference fit with EFV | |
7E | Reducer Mechanical Stab with EFV | |
7F | Reducer Mechanical interference fit with EFV | |
82 | Tapping Tee Saddle heat fusion by butt fusion outlet with EFV | |
84 | Tapping Tee Saddle heat fusion by socket outlet with EFV | |
86 | Tapping Tee Saddle heat fusion by mechanical compression outlet with EFV | |
88 | Tapping Tee Saddle heat fusion by stab outlet with EFV | |
8A | Tapping Tee Electrofusion by butt fusion outlet with EFV | |
8C | Tapping Tee Electrofusion by socket outlet with EFV | |
8E | Tapping Tee Electrofusion by mechanical compression outlet with EFV | |
8G | Tapping Tee Electrofusion by stab outlet with EFV | |
8J | Tapping Tee Mechanical by butt fusion with EFV | |
8L | Tapping Tee Mechanical by socket fusion with EFV | |
8N | Tapping Tee Mechanical by mechanical compression outlet with EFV | |
8Q | Tapping Tee Mechanical by stab outlet with EFV | |
8S | Tapping Tee Mechanical by mechanical interference fit with EFV | |
V0 | Other Valve |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 1 | Excess Flow Valve | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_DesignType |
Description | List of types for pipeline valves |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
40 | Ball | |
41 | Butterfly | |
42 | Gate | |
43 | Globe | |
44 | Needle | |
45 | Pop | |
46 | Plug | |
47 | Stop | |
48 | Stop Cock | |
49 | V-Ball | |
50 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | designtype |
main.P_LineValveInspection | valvetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Meter_Diameter-Customer |
Description | List of valid diameter sizes for customer meters |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 27 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
0.75 | 3/4" | |
1 | 1" | |
1.125 | 1 1/8" | |
1.25 | 1 1/4" | |
1.375 | 1 3/8" | |
1.5 | 1 1/2" | |
1.875 | 1 7/8" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
5 | 5" | |
5.5 | 5 1/2" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 2 | Meter | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_HCA_Provenance |
Description | List of valid methods for defining consequence segments |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Class 3 or 4 Designation | Class 3 or 4 Designation | |
Identified Site | Identified Site | |
Sliding Circle and Class Designation | Sliding Circle and Class Designation | |
Sliding Circle and Identified Site | Sliding Circle and Identified Site | |
Engineering Assessment | Engineering Assessment |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ConsequenceSegment | 0 | Installed | type |
main.P_ConsequenceSegment | 1 | Calculated | type |
main.P_ConsequenceSegment | 2 | Approved | type |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_End_Cap_Manufacture_Component |
Description | List of ASTM F-2897 types of End Cap Manufacture Models |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
40 | Other End Cap | |
41 | Butt fusion End Cap | |
42 | Socket fusion End Cap | |
43 | Electrofusion End Cap | |
44 | Mechanical compression or nut follower End Cap | |
45 | Mechanical stab End Cap | |
46 | Mechanical interference fit End Cap | |
47 | Welded End Cap | |
48 | Threaded End Cap | |
49 | Fabricated End Cap | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 3 | End Cap | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Surface_Area |
Description | List of valid units of measure of surface area |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 10 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
12 | Square Feet | |
11 | Square Inches | |
114 | Square Meters | |
112 | Square Centimeters |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Manufacturer |
Description | List of ASTM F2897 Manufacturers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 51 |
# of Assignments | 29 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
35 | Industrial Pipe Fittings | |
73 | Plasson | |
78 | Torre Gas | |
AD | A-D Technologies | |
AG | Agru America Inc | |
AV | American AVK Co | |
AY | A.Y. McDonald Mfg Co. | |
BM | BROEN Inc | |
CE | Centennial Plastics | |
CF | Chicago Fittings Corp | |
CH | Charter Plastics Inc | |
CI | Continental Industries | |
CP | Georg Fischer Central Plastics LLC | |
DF | Improved Piping Products | |
DR | Dresser Pipeline Solutions | |
EL | Elster Perfection | |
EN | Endot Industries Inc | |
FR | IPEX Inc | |
FT | Aliaxis Deutschland GmbH | |
GB | Gas Breaker Inc | |
HE | Hawkeye Industries Inc | |
HF | Valencia Pipe Company | |
IN | Innoge | |
IP | Infra Pipe Solutions | |
IU | IPEX USA LLC | |
JM | J-M Manufacturing Co. | |
KT | Kerotest Manufacturing Corp | |
KU | Krah USA LLC | |
MT | M.T. Deason Co. inc | |
MU | Mueller Co. LLC | |
NG | Nupi Americas | |
PC | Poly-Cam Inc | |
PE | Performance Pipe | |
PL | Pipeline Plastics | |
PP | DuraLine | |
PT | Polytubes LP | |
PV | PolyValve LLC | |
QC | Oil Creek Plastics | |
RP | Rahn Plastics | |
RW | R.W. Lyall | |
SB | Smith-Blair Inc | |
SG | Shawcor Composite Production Systems | |
SL | Silver-Line Plastics | |
TD | T.D. Williamson | |
TP | Teel Pipe LLC | |
UI | Uponor Infra Limited | |
UP | United Poly Systems | |
US | US Steel Corp | |
VP | Versaprofiles Inc | |
WL | WL Plastics |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Strainer_Model |
Description | List of the types of manufacturer models of strainers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StrainerInspect | strainermodel |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Meter_Manufacture_Component |
Description | List of ASTM F-2897 Meter Set Manufacture Model |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
M0 | Other Meter | |
M1 | Diaphragm Meter | |
M2 | Rotary Meter | |
M3 | Meter Set Assembly | |
M4 | Meter bar | |
M5 | Meter Swival | |
M6 | Meter Nut | |
M7 | Ultrasonic Meter | |
M8 | Turbine Meter | |
M9 | Remote shut off Meter | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 2 | Meter | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Junction_Fitting_Specification |
Description | List of dimensional specifications for steel pipe fittings |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 23 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
ASTM A403 | ASTM A403 | |
ASME B16.9 | ASME B16.9 | |
ASME B16.11 | ASME B16.11 | |
ASME B16.5 | ASME B16.5 | |
ASME B16.47 | ASME B16.47 | |
MSS SP-75 | MSS SP-75 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Pipe_Manufacture_Component |
Description | List of ASTM F-2897 Pipe Specifications |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
10 | Other Pipe | |
11 | Straight Pipe | |
12 | Coiled Pipe | |
13 | Casing Pipe | |
1A | Seamless Line Pipe, API 5L, PSL1, Single Coat Pipe | |
1B | Seamless Line Pipe, API 5L, PSL1, Dual Coat Pipe | |
1C | Seamless Line Pipe, API 5L, PSL2, Single Coat Pipe | |
1D | Seamless Line Pipe, API 5L, PSL2, Dual Coat Pipe | |
1E | Electric Resistance Weld, API 5L, PSL1, Single Coat Pipe | |
1F | Electric Resistance Weld, API 5L, PSL1, Dual Coat Pipe | |
1G | Electric Resistance Weld, API 5L, PSL2, Single Coat Pipe | |
1H | Electric Resistance Weld, API 5L, PSL2, Dual Coat Pipe | |
1J | Seamless and Welded ASTM A53/A53M Pipe | |
1K | Seamless Carbon Steel ASTM A106 Pipe | |
1L | High Frequency Weld, API 5L, PSL2 Single Coat | |
1M | High Frequency Weld API 5L, PSL2 Dual Coat | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | manufacturecomponent |
main.PipelineLine | 2 | Distribution Pipe | manufacturecomponent |
main.PipelineLine | 4 | Gathering Pipe | manufacturecomponent |
main.PipelineLine | 6 | Customer Pipe | manufacturecomponent |
main.PipelineLine | 8 | Storage Pipe | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Class |
Description | List of the types of valid classes of leak |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 23 |
Code | Description | Details |
---|---|---|
0 | No Leak | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Pipe_Material |
Description | List of ASTM F-2897 Material for Pipe Grade |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 36 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
A | PE2406 | |
B | PE2708 | |
d | PE2708 Plus | |
C | PE3408 | |
D | PE3608 | |
E | PE3708 | |
F | PE3710 | |
G | PE4608 | |
H | PE4710 | |
e | PE4710 Plus | |
J | PVC | |
K | PA11 | |
L | PA12 | |
M | Steel | |
N | Stainless Steel | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
T | Reinforced Epoxy Resin | |
U | Nylon | |
V | Glass Filler Nylon | |
W | PE80 | |
X | Other | |
Y | PEX | |
Z | PE100 | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | material |
main.PipelineLine | 2 | Distribution Pipe | material |
main.PipelineLine | 4 | Gathering Pipe | material |
main.PipelineLine | 6 | Customer Pipe | material |
main.PipelineLine | 8 | Storage Pipe | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Regulator_Manufacture_Component |
Description | List of ASTM F-2897 Regulator Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
RX | Other Regulator | |
RP | Pilot Regulator | |
RS | Service Regulator | |
RR | Relief Regulator | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 19 | Regulator | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Riser_Pipe_Material |
Description | List of ASTM F-2897 Material for Riser Pipe Grade |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 30 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
A | PE2406 | |
B | PE2708 | |
d | PE2708 Plus | |
C | PE3408 | |
D | PE3608 | |
E | PE3708 | |
F | PE3710 | |
G | PE4608 | |
H | PE4710 | |
e | PE4710 Plus | |
M | Steel | |
N | Stainless Steel | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
W | PE80 | |
Y | PEX | |
Z | PE100 | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Wellhead_Diameter |
Description | List of valid nominal diameters for wellheads |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | 2 | |
2.5 | 2.5 | |
3 | 3 | |
4 | 4 | |
5 | 5 | |
6 | 6 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Saddle_Manufacture_Component |
Description | List of ASTM F-2897 Saddle Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 28 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
B0 | Other branch saddle | |
B1 | Electrofusion branch saddle | |
B2 | Saddle heat fusion branch saddle | |
B3 | Mechanical fusion branch saddle | |
D0 | Other mechanical saddle service tee | |
D1 | Welded by welded mechanical saddle service tee | |
D2 | Welded by butt fusion mechanical saddle service tee | |
D3 | Welded by thread mechanical saddle service tee | |
D4 | Welded by compression or nut follower saddle service tee | |
D5 | Welded by mechanical interference fit mechanical saddle service tee | |
DD | Welded by stab mechanical saddle service tee | |
D6 | Thread by Welded mechanical saddle service tee | |
D7 | Thread by compression or nut follower mechanical saddle service tee | |
DE | Thread by mechanical interference fit mechanical saddle service tee | |
DF | Thread by stab mechanical saddle service tee | |
DG | Thread by thread mechanical saddle service tee | |
DH | Thread by butt fusion mechanical saddle service tee | |
D8 | Mechanical saddle by welded mechanical saddle service tee | |
D9 | Mechanical saddle by butt fusion mechanical saddle service tee | |
DA | Mechanical saddle by thread mechanical saddle service tee | |
DB | Mechanical saddle by compression or nut follower mechanical saddle service tee | |
DC | Mechanical saddle by mechanical interference fit mechanical saddle service tee | |
DJ | Mechanical saddle by stab mechanical saddle service tee | |
E0 | Other service saddle | |
E1 | Single strap service saddle | |
E2 | Double strap service saddle | |
0 | Unknown | |
S1 | Mechanical Saddle No Outlet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 13 | Saddle | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Station_Pipe_Material |
Description | List of ASTM F-2897 Material for Station Pipe Grade |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 20 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
M | Steel | |
N | Stainless Steel | |
T | Reinforced Epoxy Resin | |
U | Nylon | |
V | Glass Filler Nylon | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 5 | Station Pipe | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Station_Pipe_Type |
Description | List of ASTM F-2897 valid Station Pipe Specification |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 15 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
10 | Other Pipe | |
13 | Casing Pipe | |
1A | Seamless Line Pipe, API 5L, PSL1, Single Coat Pipe | |
1B | Seamless Line Pipe, API 5L, PSL1, Dual Coat Pipe | |
1C | Seamless Line Pipe, API 5L, PSL2, Single Coat Pipe | |
1D | Seamless Line Pipe, API 5L, PSL2, Dual Coat Pipe | |
1E | Electric Resistance Weld, API 5L, PSL1, Single Coat Pipe | |
1F | Electric Resistance Weld, API 5L, PSL1, Dual Coat Pipe | |
1G | Electric Resistance Weld, API 5L, PSL2, Single Coat Pipe | |
1H | Electric Resistance Weld, API 5L, PSL2, Dual Coat Pipe | |
1J | Seamless and Welded ASTM A53/53M Pipe | |
1K | Seamless Carbon Steel ASTM A106 Pipe | |
1L | High Frequency Weld, API 5L, PSL2 Single Coat | |
1M | High Frequency Weld API 5L, PSL2 Dual Coat |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 5 | Station Pipe | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pressure_Test_Type |
Description | List of Valid types of pressure tests used on pipe system |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Strength | Strength | |
Spike | Spike | |
Yield | Yield | |
Uprating | Uprating | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_TestPressureRange | testtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Strainer_Manufacture_Component |
Description | List of ASTM F-2897 Strainer Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
F0 | Other Filter | |
F1 | Pilot Filter | |
F2 | Service and mains Filter | |
F3 | Strainer Filter | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 6 | Strainer | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Tee_Manufacture_Component |
Description | List of ASTM F-2897 Tee Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 46 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
60 | Other 3-Way Tee | |
61 | Butt fusion 3-Way Tee | |
62 | Socket fusion 3-Way Tee | |
63 | Electrofusion 3-Way Tee | |
64 | Mechanical compression or nut follower 3-Way Tee | |
65 | Mechanical stab 3-Way Tee | |
66 | Mechanical interference fit 3-Way Tee | |
67 | Welded 3-Way Tee | |
68 | Threaded 3-Way Tee | |
69 | Fabricated 3-Way Tee | |
80 | Other Tapping Tee | |
81 | Saddle heat fusion by butt fusion outlet tapping Tee | |
82 | Saddle heat fusion by butt fusion outlet with EFV tapping Tee | |
83 | Saddle heat fusion by socket outlet tapping Tee | |
84 | Saddle heat fusion by socket outlet with EFV tapping Tee | |
85 | Saddle heat fusion by mechanical compression outlet tapping Tee | |
86 | Saddle heat fusion by mechanical compression outlet with EFV tapping Tee | |
87 | Saddle heat fusion by stab outlet tapping Tee | |
88 | Saddle heat fusion by stab outlet with EFV tapping Tee | |
89 | Electrofusion by butt fusion outlet tapping Tee | |
8A | Electrofusion by butt fusion outlet with EFV tapping Tee | |
8B | Electrofusion by socket fusion tapping Tee | |
8C | Electrofusion by socket fusion with EFV tapping Tee | |
8D | Electrofusion by mechanical compression outlet tapping Tee | |
8E | Electrofusion by mechanical compression outlet with EFV tapping Tee | |
8F | Electrofusion by stab outlet tapping Tee | |
8G | Electrofusion by stab outlet with EFV tapping Tee | |
8H | Mechanical by butt fusion tapping Tee | |
8J | Mechanical by butt fusion with EFV tapping Tee | |
8K | Mechanical by Socket outlet tapping Tee | |
8L | Mechanical by socket outlet with EFV tapping Tee | |
8M | Mechanical by mechanical compression outlet tapping Tee | |
8N | Mechanical by mechanical compression outlet with EFV tapping Tee | |
8P | Mechanical by stab outlet tapping Tee | |
8Q | Mechanical by stab outlet with EFV tapping Tee | |
8R | Mechanical by mechanical interference fit tapping Tee | |
8S | Mechanical by mechanical interference fit with EFV tapping Tee | |
90 | Other high volume tapping Tee | |
91 | Electrofusion by butt fusion high volume tapping Tee | |
92 | Saddle heat fusion by butt fusion high volume tapping Tee | |
93 | Mechanical by compression outlet high volume tapping Tee | |
94 | Electrofusion by socket outlet high volume tapping Tee | |
95 | Saddle heat fusion by socket outlet high volume tapping Tee | |
96 | Mechanical by stab outlet high volume tapping Tee | |
97 | Mechanical by mechanical interference fit high volume tapping Tee | |
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 7 | Tee | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Transition_Manufacture_Component |
Description | List of ASTM F-2897 Transition Manufacture Model Types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
T0 | Other Transition | |
T1 | Welded end Transition | |
T2 | Thread end Transition | |
T3 | Flanged end Transition | |
0 | Unknown | |
FP | PE Flange Adapter Assembly |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 8 | Transition | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Transmission_Pipe_Material |
Description | List of ASTM F-2897 Material for Transmission Pipe Grade |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 20 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
M | Steel | |
N | Stainless Steel | |
T | Reinforced Epoxy Resin | |
U | Nylon | |
V | Glass Filler Nylon | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | material | ||
main.StructureLine | 0 | Unknown | material |
main.StructureLine | 1 | Pipe Casing | material |
main.PipelineAssembly | 7 | Pigging Structure | pipegrade |
main.PipelineLine | 3 | Transmission Pipe | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Cooling_Method |
Description | List of systems used to prevent the rectifier from overheating |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 51 | Rectifier | adddetails |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ASTM_Transmission_Pipe_Type |
Description | List of ASTM F-2897 valid Transmission Pipe Specification |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 15 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
10 | Other Pipe | |
13 | Casing Pipe | |
1A | Seamless Line Pipe, API 5L, PSL1, Single Coat Pipe | |
1B | Seamless Line Pipe, API 5L, PSL1, Dual Coat Pipe | |
1C | Seamless Line Pipe, API 5L, PSL2, Single Coat Pipe | |
1D | Seamless Line Pipe, API 5L, PSL2, Dual Coat Pipe | |
1E | Electric Resistance Weld, API 5L, PSL1, Single Coat Pipe | |
1F | Electric Resistance Weld, API 5L, PSL1, Dual Coat Pipe | |
1G | Electric Resistance Weld, API 5L, PSL2, Single Coat Pipe | |
1H | Electric Resistance Weld, API 5L, PSL2, Dual Coat Pipe | |
1J | Seamless and Welded ASTM A53/53M Pipe | |
1K | Seamless Carbon Steel ASTM A106 Pipe | |
1L | High Frequency Weld, API 5L, PSL2 Single Coat | |
1M | High Frequency Weld API 5L, PSL2 Dual Coat |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 3 | Transmission Pipe | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ILI_Survey_Int_Ext_Indicator |
Description | Indicator of whether the ILI Survey readings were internal or external |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
External | External | |
Internal | Internal | |
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ILISurveyReadings | intextindicator |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Casing_Diameter |
Description | List of valid casing diameters |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 23 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | 4 | |
6 | 6 | |
8 | 8 | |
10 | 10 | |
12 | 12 | |
14 | 14 | |
16 | 16 | |
18 | 18 | |
20 | 20 | |
22 | 22 | |
24 | 24 | |
26 | 26 | |
28 | 28 | |
30 | 30 | |
32 | 32 | |
34 | 34 | |
36 | 36 | |
40 | 40 | |
42 | 42 | |
44 | 44 | |
46 | 46 | |
48 | 48 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | casingdiameter | ||
main.StructureLine | 1 | Pipe Casing | casingdiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Casing_Fill_Type |
Description | List of valid casing fill types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Grout | |
2 | Pea Gravel | |
3 | Sand |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 0 | Unknown | filltype |
main.StructureLine | 1 | Pipe Casing | filltype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Commodity_Type |
Description | List of types of commodity which can be transported by the pipe system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Natural Gas | |
2 | Synthetic Gas | |
3 | Hydrogen Gas | |
4 | Propane Gas | |
6 | Petroleum | |
7 | Gasoline | |
8 | Diesel | |
9 | Water | |
10 | Wastewater | |
11 | Steam | |
12 | Crude | |
13 | Liquid Natural Gas | |
14 | Natural Gas Liquids | |
15 | Carbon Dioxide Gas | |
5 | Renewable Natural Gas |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Consequence_Area_Type |
Description | List of valid Consequence Area types |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
High | High | |
Medium | Medium |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ConsequenceSegment | 0 | Installed | consequenceareatype |
main.P_ConsequenceSegment | 1 | Calculated | consequenceareatype |
main.P_ConsequenceSegment | 2 | Approved | consequenceareatype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Control_Line_Manufacturer |
Description | List of valid type of manufacturers of control lines of strainers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StrainerInspect | controllinemanufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Control_Line_Model |
Description | List of the types of manufacturer models of control lines for strainers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StrainerInspect | controllinemodel |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Inspect_Gas_In |
Description | List of the valid types of locations where leaking gas is detected |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 12 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Air | Air | |
Building | Building | |
Soil | Soil | |
Manhole | Manhole | |
Test Box | Test Box | |
Catch Basin | Catch Basin | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 0 | Unknown | gasin |
main.P_GasLeak | 1 | Incorrect Operations | gasin |
main.P_GasLeak | 2 | Material or Welds | gasin |
main.P_GasLeak | 3 | Manufacturing | gasin |
main.P_GasLeak | 4 | Construction | gasin |
main.P_GasLeak | 5 | Equipment | gasin |
main.P_GasLeak | 6 | Natural Forces | gasin |
main.P_GasLeak | 7 | Corrosion | gasin |
main.P_GasLeak | 8 | Other Outside Force Damage | gasin |
main.P_GasLeak | 9 | Excavation Damage | gasin |
main.P_GasLeak | 10 | Other | gasin |
main.P_GasLeakInspect | gasin |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Corrosion_Extent |
Description | List of valid descriptions of the extent of corrosion |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
General | General | |
Localized | Localized | |
None | None |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExposedPipeInspect | corrosionextent |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsSubnetworkController |
Description | Indicates if a device feature is a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 25 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Could_Affect_Intersection |
Description | Type of impact the pipe spillage could have on a transportation intersection |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Direct | Direct | |
Indirect | Indirect | |
Potential | Potential |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_CouldAffectSegment | intersectiontype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Could_Affect_Type |
Description | List of valid areas impacted by spillage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
High Population | High Population | |
Other Population | Other Population | |
Ecological Area | Ecological Area | |
Drinking Water | Drinking Water | |
Navigable Waterway | Navigable Waterway |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_CouldAffectSegment | couldaffectsegmenttype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_DA_Survey_Type |
Description | List of valid types of direct assessment |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Close Interval Potential Survey | Close Interval Potential Survey | |
Direct Current Voltage Gradient | Direct Current Voltage Gradient | |
Pipeline Current Mapper | Pipeline Current Mapper | |
Pearson Survey | Pearson Survey | |
Alternate Current Voltage Gradient | Alternate Current Voltage Gradient |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_DASurveyReadings | datype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Dehydration_Manufacturer |
Description | List of valid manufacturers of oil and gas dehydration equipment |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 19 | Dehydration Equipment | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Dehydration_Model |
Description | List of valid models of oil and gas dehydration equipment |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 19 | Dehydration Equipment | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Document_Maturity_Index |
Description | List of valid ratings of the quality of the documentation |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
High | High | |
Medium | Medium | |
Low | Low |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_MAOPCalcRange | documentmaturityindex |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Document_Type |
Description | List of valid types of document format |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Adobe Acrobat | Adobe Acrobat (PDF) | |
Autocad Drawing | Autocad Drawing (DWG) | |
Bitmap | Bitmap (BMP) | |
GIF | GIF | |
HTML | HTML (HTM) | |
JPEG | JPEG (JPG) | |
Microsoft Excel | Microsoft Excel(XLS) | |
Microsoft Word | Microsoft Word (DOC) | |
Microstation Drawing | Microstation (DGN) | |
Text | Text | |
TIFF | TIFF |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_DocumentPoint | documenttype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_DOT_Class_Source |
Description | List of methods for determining DOT classification |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Unknown (Verified) | Unknown (Verified) | |
Calculated | Calculated | |
Manual | Manual |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_DOTClass | classsource |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_DOT_Class_Type |
Description | List of valid types of pipeline classification |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_HighConsequenceArea | consequenceclass | ||
main.P_DOTClass | classtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_EFV_Diameter |
Description | List of valid diameter sizes for excess flow valves |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
0.75 | 3/4" | |
1 | 1" | |
1.125 | 1 1/8" | |
1.25 | 1 1/4" | |
1.375 | 1 3/8" | |
1.5 | 1 1/2" | |
1.875 | 1 7/8" | |
2 | 2" | |
3 | 3" | |
4 | 4" | |
5 | 5" | |
6 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 1 | Excess Flow Valve | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Drip_Manufacturer |
Description | List of valid manufacturers of gas drips |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 20 | Drip | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_End_Connection_Model |
Description | List of valid manufacturers models of oil and gas pipe casing end connections |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 5 | Pipe End Connection | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Damage_Type |
Description | List of the types of valid types of excavation damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Dent | Dent | |
Gouge | Gouge | |
Line Cut | Line Cut | |
Puncture | Puncture | |
Pulled | Pulled | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakRepairs | damagetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Dam_Resp_Party_Type |
Description | List of valid types of entities who are responsible for excavation damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Company | Company | |
Homeowner | Homeowner | |
Other Utility | Other Utility | |
Local Government | Local Government | |
State Government | State Government | |
Federal Government | Federal Government | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | responsiblepartytype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Odorant_Type |
Description | List of Valid types of odorant used in the odorizer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 17 | Odorizer | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Dam_Root_Cause |
Description | List of underlying causes of the excavation damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 19 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Clearance Not Maintained | Clearance Not Maintained | |
Failure to Mark | Failure to Mark | |
Hand Digging | Hand Digging | |
Incorrect Records | Incorrect Records | |
Incorrect Ticket Info | Incorrect Ticket Info | |
Locate Not Requested | Locate Not Requested | |
Locate Time Exceeded | Locate Time Exceeded | |
Locate Markings Incorrect | Locate Markings Incorrect | |
Locating Wire Missing Broken | Locating Wire Missing Broken | |
Marks Destroyed | Marks Destroyed | |
Mech Equip Within 2ft | Mech Equip Within 2ft | |
No Probable Violation | No Probable Violation | |
Ticket Expired | Ticket Expired | |
Trenchless Excav Bore Stakes | Trenchless Excav Bore Stakes | |
Trenchless Excav Ground Rod | Trenchless Excav Ground Rod | |
Trenchless Excav Expose Util | Trenchless Excav Expose Util | |
Trenchless Excav Drill Head | Trenchless Excav Drill Head | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | rootcause |
Key | Value |
---|---|
Owner | |
Domain Name | Yes_No |
Description | Valid Yes, No values |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 267 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Yes | |
2 | No |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Dam_Work_Type |
Description | List of the types of work responsible for causing excavation damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Cut and Cap Gas Service | Cut and Cap Gas Service | |
Commercial Construction | Commercial Construction | |
Demolition | Demolition | |
Foundation Excavation | Foundation Excavation | |
Install Irrigation System | Install Irrigation System | |
Install Fence | Install Fence | |
Landscaping | Landscaping | |
Residential Construction | Residential Construction | |
Replace Curb | Replace Curb | |
Road Construction | Road Construction | |
Soil Boring | Soil Boring | |
Utility Install | Utility Install | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | worktype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Excav_Equip_Causing_Damage |
Description | List of valid types of equipment responsible for causing damage to the gas pipe system |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Auger | Auger | |
Backhoe | Backhoe | |
Bore | Bore | |
Shovel | Shovel | |
Trencher | Trencher | |
Vehicle | Vehicle | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | equipcausingdamage |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Fitting_Diameter |
Description | List of valid diameter sizes for Pipeline Junction Single Diameter Fittings |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 32 |
# of Assignments | 37 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
0.75 | 3/4" | |
1 | 1" | |
1.125 | 1 1/8" | |
1.25 | 1 1/4" | |
1.375 | 1 3/8" | |
1.5 | 1 1/2" | |
1.875 | 1 7/8" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
5 | 5" | |
5.5 | 5 1/2" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
26 | 26" | |
30 | 30" | |
36 | 36" | |
40 | 40" | |
48 | 48" |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Flange_DesignType |
Description | List of types for flanges |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
161 | Weld Neck | |
162 | Slip On | |
163 | Blind | |
164 | Threaded | |
165 | Socket Welded | |
166 | Lap Joint |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 5 | Flange | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Junction_Pressure_Rating |
Description | List of valid junction pressure ratings |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 19 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
150 | 150 | |
300 | 300 | |
600 | 600 | |
900 | 900 | |
1500 | 1500 | |
2500 | 2500 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Girth_Weld_Type |
Description | List of valid weld types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Welded | |
2 | Flange | |
3 | Automatic Electric Weld |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipeline_Operator_Number |
Description | The valid US DOT issued unique identifiers |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 13 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Hanger_Model |
Description | List of valid manufacturers models of oil and gas pipe hangers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 4 | Pipe Hanger | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Identified_Issue |
Description | List of the types of work responsible for causing excavation damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Corrosion | Corrosion | |
Damaged Meter | Damaged Meter | |
Dead Vegetation | Dead Vegetation | |
No Access | No Access | |
Odor | Odor | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_IdentifiedIssue | issue |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Identified_Site_Outside |
Description | List of valid types of outside Areas for High Consequence Areas |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 13 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Assembly Area | Assembly Area | |
Beach | Beach | |
Campground | Campground | |
Cemetary | Cemetary | |
Outside Theatre | Outside Theatre | |
Park | Park | |
Parking Lot | Parking Lot | |
Playground | Playground | |
Recreational Area | Recreational Area | |
Amusement Park | Amusement Park | |
Athletic Field | Athletic Field | |
Drive-In Theater | Drive-In Theater |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_OutsideArea | identifiedsitetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_ILI_Survey_Type |
Description | List of valid types of ILI Surveys |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Crack | Crack | |
Material Defect | Meterial Defect | |
Mechanical Damage | Mechanical Damage | |
Metal Loss | Metal Loss | |
Other | Other | |
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ILISurveyReadings | surveytype | ||
main.P_ILISurveyGroup | ilisurveygrouptype |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Depth |
Description | List of valid units of measure for pipe depth below ground surface |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 30 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Inch | |
2 | Feet | |
102 | Centimeter | |
104 | Meter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Inspection_Note_Type |
Description | Type of inspection note captured during an inspection |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Environmental | Environmental | |
Gas Facility | Gas Facility | |
Hydrology | Hydrology | |
Maintenance | Maintentance | |
Other | Other | |
Unknown | Unknown | |
Pipe Crossing | Pipe Crossing |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_InspectionNote | notetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Inspection_Range_Type |
Description | List of Valid types of inspection |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Aerial Survey | Aerial Survey | |
Cathodic Protection | Cathodic Protection | |
Close Interval Survey | Close Interval Survey | |
Exposed Pipe | Exposed Pipe | |
Gas Leak | Gas Leak | |
Inline | Inline | |
Other | Other | |
Unknown | Unknown | |
Visual Survey | Visual Survey |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_InspectionRange | inspectiontype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Corrosion |
Description | List of the types of valid causes of gas leaks due to Corrosion |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Internal | Internal | |
External | External | |
Stress Cracking | Stress Cracking |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 7 | Corrosion | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Equipment |
Description | List of the types of valid causes of gas leaks due to incorrect operations |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Malfunctioning Relief Valve | Malfunctioning Relief Valve | |
Malfunctioning Regulator | Malfunctioning Regulator | |
Mechanical Fitting | Mechanical Fitting | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 5 | Equipment | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Excavation |
Description | List of the types of valid causes of gas leaks due to Excavation Damage |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Dent | Dent | |
Gouge | Gouge | |
Puncture | Puncture | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 9 | Excavation Damage | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Material |
Description | List of the types of valid causes of gas leaks due to Material |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Faulty Field Weld | Faulty Field Weld | |
Faulty Manufacture Weld | Faulty Manufacture Weld | |
Faulty Assembly by Manufacturer | Faulty Assembly by Manufacturer | |
Faulty Assembly by Construction | Faulty Assembly by Construction | |
Manufacture Defect | Manufacture Defect | |
Excessive Stress | Excessive Stress | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 2 | Material or Welds | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Operations |
Description | List of the types of valid causes of gas leaks due to Incorrect Operations |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Failure to follow procedure | Failure to follow procedure | |
Inadequate safety procedures | Inadequate safety procedures | |
Operation error | Operation error | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 1 | Incorrect Operations | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Cause_Outside_Force |
Description | List of the types of valid causes of gas leaks due to outside forces |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Fire | Fire | |
Previous Damage | Previous Damage | |
Vandalism | Vandalism | |
Vehicle Damage | Vehicle Damage | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | 8 | Other Outside Force Damage | leakcausetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Closed_Status |
Description | List of the types of valid status for a gas leak |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Active | Active | |
Cleared | Cleared | |
Repaired | Repaired |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Facility_Type |
Description | List of the types of gas system componentsr damaged by excavation |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 13 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Distribution Line | Distribution Line | |
Service Line | Service Line | |
Onshore Transmission | Onshore Transmission | |
Offshore Transmission | Offshore Transmission | |
Onshore Gathering | Onshore Gathering | |
Offshore Gathering | Offshore Gathering | |
Valve | Valve | |
Fitting | Fitting | |
Meter | Meter | |
Regulator Station | Regulator Station | |
Compressor Station | Compressor Station | |
Wellhead | Wellhead | |
Other | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Transmission |
Description | List of Valid Nominal Diameter Size for Transmission Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 36 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | 2" | |
2.5 | 2.5" | |
3 | 3" | |
3.5 | 3.5" | |
4 | 4" | |
4.5 | 4.5" | |
5 | 5" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 3 | Transmission Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Inspect_Frequency |
Description | List of the gas leak inspection frequencies |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | 1 Month | |
3 | 3 Month | |
6 | 6 Month | |
12 | 12 Month |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_GasLeak | frequency |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Location |
Description | List of the locations where a leak has been determined |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Pipe | Pipe | |
Weld | Weld | |
Joint | Joint | |
Leak Clamp | Leak Clamp | |
Flange Connection | Flange Connection | |
Valve Body | Valve Body | |
Valve Stem | Valve Stem | |
Service Riser | Service Riser | |
Cap | Cap | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakRepairs | leaklocation |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Pressure_Sensor |
Description | List of Valid Nominal Diameter Size for Pressure Sensor Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 15 | Pressure Sensor Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Repair_Type |
Description | List of the valid type of leak repair |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Permanent | Permanent | |
Temporary | Temporary | |
Not Applicable | Not Applicable |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakRepairs | leakrepairtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Survey_Frequency |
Description | List of the valid leak survey methods |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3 | 3 Months | |
4 | 4 Months | |
6 | 6 Months | |
12 | 12 Months | |
36 | 36 Months | |
60 | 60 Months |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakSurveyArea | interval |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Leak_Survey_Method |
Description | List of the valid leak survey methods |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Flame Pack | Flame Pack | |
CGI | CGI | |
Odor | Odor | |
Vegation | Vegation | |
Visual | Visual |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakSurveyArea | surveymethod |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Length_Source |
Description | List of valid types of sources for measured length |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 14 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Field Measurement | |
2 | GPS Sub- 30 Meter | |
3 | GPS Sub- 10 Meter | |
4 | GPS Sub-Meter | |
5 | GPS Sub-Foot | |
6 | GPS Centimeter | |
7 | Mapping System | |
8 | User-Derived | |
9 | Begin-End Measures |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Line_Design_Class |
Description | List of U.S. DOT classifications for design criteria of gas pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 10 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Line_Heater_Manufacturer |
Description | List of valid manufacturers of oil and gas Line Heaters |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 15 | Line Heater | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Soil_Type |
Description | List of predominant type of soil located at the depth of the buried gas asset |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Cinders | Cinders | |
Clay | Clay | |
Gravel | Gravel | |
Loam | Loam | |
Rock | Rock | |
Sand | Sand | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LeakRepairs | soilatpipedepth | ||
main.P_ExposedPipeInspect | soiltype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Line_Pipe_Test_Type |
Description | List of valid types of substances for pressure testing gas lines |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Air | Air | |
Gas | Gas | |
Water | Water |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Line_Valve_Connection |
Description | List of the type of connections used for Line Valves |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LineValveInspection | lineconnection |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Lining_Type |
Description | List of Valid types of material used to cover the interior of the tank to prevent leakage |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 14 | Tank | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Odorizer_Model |
Description | List of valid models of gas odorizer system models |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 17 | Odorizer | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_MAOP_Pressure_Estab_By |
Description | List of Valid methods to establish a pipe system pressure |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Design | Design | |
Certificate | Certificate | |
Grandfather | Grandfather | |
Special Permit | Special Permit | |
Pressure Type | Pressure Type | |
Operator Assigned | Operator Assigned | |
Historical | Historical | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_OperatingPressureRange | pressuretype | ||
main.P_MAOPCalcRange | pressureestablishedby |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Marker_Markertype |
Description | List of valid types of pipe;ine markers |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Aerial Marker | |
2 | Pipeline Marker | |
3 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipelineMarker | markertype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Measurement_Units |
Description | List of the units of measurement of leaking gas |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 12 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Parts Per Million | |
2 | Percent Gas |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Meter_Type |
Description | List of valid types of meters |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Annubar | |
2 | Diaphragm | |
3 | Oriface | |
4 | Rotary | |
5 | Thermal Well | |
6 | Turbine | |
7 | Ultrasonic |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 2 | Meter | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Muffler_Model |
Description | List of valid manufacturer models of gas compressor station muffler |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 1 | Pipe Muffler | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Object_Status |
Description | List of valid lifecycle status for a non-asset object |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 21 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Conceptual | Conceptual | |
Proposed | Proposed | |
Active | Active | |
Inactive | Inactive |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Odorizer_Manufacturer |
Description | List of valid manufacturers of gas Odorizer systems |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
U | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 17 | Odorizer | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_On_Off_Status |
Description | Indicate whether a device is on or off |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
U | Unknown | |
On | On | |
Off | Off |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_CPRectifierInspection | statusasfound | ||
main.P_CPRectifierInspection | statusasleft |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Operator_Type |
Description | Valve and Regulator Operator Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Manual | |
2 | Remote |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | operatortype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Over_Pressure_Protection_Type |
Description | List of types of over pressure protection for pipeline facilities |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Full Capacity Relief Valve | |
2 | Monitor and Operator | |
3 | Monitor Only | |
4 | Operator and Monitor | |
5 | Operator Only |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 3 | Regulator Station | prottype |
main.PipelineAssembly | 5 | Town Border Station | prottype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pass_Fail_Status |
Description | Indicate whether the inspection characteristic passed or failed the inspection criteria |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 21 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Pass | |
2 | Fail | |
3 | Not Inspected |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pigging_Structure_Material |
Description | List of types of material for pigging structures |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Steel | Steel | |
Concrete | Concrete |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 7 | Pigging Structure | pipematerial |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_PipeBend_DesignType |
Description | List of valid pipe bends |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
51 | 30 Degree Bend | |
52 | 45 Degree Bend | |
53 | 60 Degree Bend | |
54 | 90 Degree Bend |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 30 | Pipe Bend | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Condition |
Description | List of valid observations of the gas asset |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Normal | Normal | |
Fair | Fair | |
Poor | Poor |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExposedPipeInspect | pipecondition |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wall_Thickness-Transmission |
Description | List of NPS valid wall thickness of Transmission Steel Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.068 | 0.068" | |
0.083 | 0.083" | |
0.088 | 0.088" | |
0.091 | 0.091" | |
0.109 | 0.109" | |
0.113 | 0.113" | |
0.12 | 0.120" | |
0.133 | 0.133" | |
0.134 | 0.134" | |
0.14 | 0.140" | |
0.145 | 0.145" | |
0.148 | 0.148" | |
0.154 | 0.154" | |
0.165 | 0.165" | |
0.18 | 0.180" | |
0.203 | 0.203" | |
0.216 | 0.216" | |
0.226 | 0.226" | |
0.237 | 0.237" | |
0.247 | 0.247" | |
0.25 | 0.250" | |
0.258 | 0.258" | |
0.277 | 0.277" | |
0.28 | 0.280" | |
0.281 | 0.281" | |
0.301 | 0.301" | |
0.307 | 0.307" | |
0.312 | 0.312" | |
0.322 | 0.322" | |
0.33 | 0.330" | |
0.337 | 0.337" | |
0.342 | 0.342" | |
0.355 | 0.355" | |
0.365 | 0.365" | |
0.375 | 0.375" | |
0.406 | 0.406" | |
0.432 | 0.432" | |
0.437 | 0.437" | |
0.5 | 0.500" | |
0.562 | 0.562" | |
0.593 | 0.593" | |
0.625 | 0.625" | |
0.656 | 0.656" | |
0.75 | 0.750" | |
0.812 | 0.812" | |
0.968 | 0.968" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | wallthickness | ||
main.StructureLine | 0 | Unknown | wallthickness |
main.StructureLine | 1 | Pipe Casing | wallthickness |
main.PipelineLine | 3 | Transmission Pipe | wallthickness |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Crossing_Location |
Description | Indicator of whether the foreign object crosses above or below the pipe |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Above | Above | |
Below | Below |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeCrossing | 0 | Unknown | crossinglocation |
main.P_PipeCrossing | 1 | Pipe Utility | crossinglocation |
main.P_PipeCrossing | 2 | Wire Utility | crossinglocation |
main.P_PipeCrossing | 3 | Transportation | crossinglocation |
main.P_PipeCrossing | 4 | Topographic | crossinglocation |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Weld_Joint_Coat_Type |
Description | Pipe Weld Joint Coating Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Tape | |
2 | Asphalt | |
3 | Coal Tar | |
4 | Coal Tar Enamel | |
5 | Enamel | |
6 | Epoxy | |
7 | None | |
8 | Other | |
9 | Paint | |
10 | Tar | |
11 | Wax |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 9 | Weld | jointcoatingtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Crossing_Pipe_Utility |
Description | Type of piped utility crossing the pipeline |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Petroleum Pipeline | Petroleum Pipeline | |
Natural Gas Pipeline | Natural Gas Pipeline | |
Sewer | Sewer | |
Storm Sewer | Storm Sewer | |
Water | Water | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeCrossing | 1 | Pipe Utility | crossingfeaturetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Crossing_Topographic |
Description | Type of topographic features crossing the pipeline |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Fault Line | Fault Line | |
Levee | Levee | |
Water | Water | |
Wetlands | Wetlands | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeCrossing | 4 | Topographic | crossingfeaturetype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Combined |
Description | List of Valid Nominal Diameter Size for All Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 46 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4 | |
0.375 | 3/8 | |
0.5 | 1/2 | |
0.75 | 3/4 | |
1 | 1 | |
1.25 | 1 1/4 | |
1.5 | 1 1/2 | |
2 | 2 | |
2.5 | 2 1/2 | |
3 | 3 | |
3.5 | 3 1/2 | |
4 | 4 | |
4.5 | 4 1/2 | |
5 | 5 | |
6 | 6 | |
7 | 7 | |
8 | 8 | |
9 | 9 | |
10 | 10 | |
12 | 12 | |
14 | 14 | |
16 | 16 | |
18 | 18 | |
20 | 20 | |
22 | 22 | |
24 | 24 | |
26 | 26 | |
28 | 28 | |
30 | 30 | |
32 | 32 | |
34 | 34 | |
36 | 36 | |
40 | 40 | |
42 | 42 | |
44 | 44 | |
48 | 48 | |
52 | 52 | |
56 | 56 | |
60 | 60 | |
64 | 64 | |
68 | 68 | |
72 | 72 | |
76 | 76 | |
80 | 80 | |
88 | 88 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 8 | Storage Pipe | nominaldiameter |
main.P_RegulatorInspect | regulatordiameter | ||
main.P_RegulatorInspect | innervalvediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Distribution |
Description | List of Valid Nominal Diameter Size for Distribution Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 23 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" | |
7 | 7" | |
8 | 8" | |
9 | 9" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 2 | Distribution Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Gathering |
Description | List of Valid Nominal Diameter Size for Gathering Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 23 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" | |
7 | 7" | |
8 | 8" | |
9 | 9" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 4 | Gathering Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Diameter-Station |
Description | List of Valid Nominal Diameter Size for Station Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 33 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | 4" | |
6 | 6" | |
7 | 7" | |
8 | 8" | |
9 | 9" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" | |
88 | 88" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 0 | Unknown | diameter |
main.PipelineAssembly | 3 | Regulator Station | diameter |
main.PipelineAssembly | 5 | Town Border Station | diameter |
main.PipelineAssembly | 7 | Pigging Structure | diameter |
main.PipelineLine | 5 | Station Pipe | nominaldiameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Outside_Diameter |
Description | List of outside diameter Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 1 | Service Pipe | outsidediameter |
main.PipelineLine | 2 | Distribution Pipe | outsidediameter |
main.PipelineLine | 4 | Gathering Pipe | outsidediameter |
main.PipelineLine | 6 | Customer Pipe | outsidediameter |
main.PipelineLine | 8 | Storage Pipe | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Outside_Diameter-Riser |
Description | List of NPS outside diameter for Riser Steel Pipe Material |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.54 | 0.540" | |
0.675 | 0.675" | |
0.84 | 0.840" | |
1.05 | 1.050" | |
1.315 | 1.315" | |
1.66 | 1.660" | |
1.9 | 1.900" | |
2.375 | 2 3/8" | |
2.875 | 2 7/8" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
5.563 | 5.563 | |
6.625 | 6 5/8" | |
7.625 | 7 5/8" | |
8.625 | 8 5/8" | |
9.625 | 9 5/8" | |
10.75 | 10 3/4" | |
12.75 | 12 3/4" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
46 | 46" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" | |
88 | 88" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 7 | Riser Pipe | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Outside_Diameter-Transmission |
Description | List of NPS outside diameter for Transmission Steel Pipe Material |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 47 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.54 | 0.540" | |
0.675 | 0.675" | |
0.84 | 0.840" | |
1.05 | 1.050" | |
1.315 | 1.315" | |
1.66 | 1.660" | |
1.9 | 1.900" | |
2.375 | 2 3/8" | |
2.875 | 2 7/8" | |
3.5 | 3 1/2" | |
4 | 4" | |
4.5 | 4 1/2" | |
5 | 5" | |
5.563 | 5.563 | |
6.625 | 6 5/8" | |
7.625 | 7 5/8" | |
8.625 | 8 5/8" | |
9.625 | 9 5/8" | |
10.75 | 10 3/4" | |
12.75 | 12 3/4" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
22 | 22" | |
24 | 24" | |
26 | 26" | |
28 | 28" | |
30 | 30" | |
32 | 32" | |
34 | 34" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
44 | 44" | |
46 | 46" | |
48 | 48" | |
52 | 52" | |
56 | 56" | |
60 | 60" | |
64 | 64" | |
68 | 68" | |
72 | 72" | |
76 | 76" | |
80 | 80" | |
88 | 88" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 3 | Transmission Pipe | outsidediameter |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Support_Manufacturer |
Description | List of valid manufacturers of oil and gas pipe supports |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 3 | Pipe Support | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Support_Material |
Description | List of valid materials of oil and gas pipe supports |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
UN | Unknown | |
O | Cast Iron | |
R | Malleable Iron | |
S | Ductile Iron | |
0 | Grade A | |
1 | Grade B | |
2 | Grade C | |
3 | Grade X42 | |
4 | Grade X46 | |
5 | Grade X52 | |
6 | Grade X56 | |
7 | Grade X60 | |
8 | Grade X65 | |
9 | Grade X70 | |
M | Steel | |
N | Stainless Steel | |
X | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 3 | Pipe Support | material |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Support_Model |
Description | List of valid manufacturers models of oil and gas pipe supports |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 3 | Pipe Support | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Test_Medium |
Description | List of valid pipe test medium |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
Water | Water | |
Hydrogen | Hydrogen | |
Air | Air |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_PipeSystemPressureTests | pipetestmedium |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wall_Thickness |
Description | List of valid wall thickness of Pipe |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | wallthickness |
main.PipelineAssembly | 7 | Pigging Structure | wallthickness |
main.PipelineLine | 1 | Service Pipe | wallthickness |
main.PipelineLine | 2 | Distribution Pipe | wallthickness |
main.PipelineLine | 4 | Gathering Pipe | wallthickness |
main.PipelineLine | 6 | Customer Pipe | wallthickness |
main.PipelineLine | 8 | Storage Pipe | wallthickness |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Pipe_Wellhead_Pressure_Rating |
Description | List of valid pressure ratings for wellheads |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2000 | 2000 psi | |
3000 | 3000 psi | |
5000 | 5000 psi | |
10000 | 10000 psi | |
15000 | 15000 psi |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | pressurerating |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Reducer_Fitting_Size |
Description | List of valid sizes for Pipeline Junction Reducer Fittings |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 72 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | 1" x 1/2" | |
2 | 1" x 5/8" | |
3 | 1" x 3/4" | |
4 | 1 1/4" x 1/2" | |
5 | 1 1/4" x 5/8" | |
6 | 1 1/4" x 3/4" | |
7 | 1 1/4" x 7/8" | |
8 | 1 1/4" x 1" | |
9 | 1 1/2" x 3/4" | |
10 | 1 1/2" x 1" | |
11 | 1 1/2" x 1 1/4" | |
12 | 2" x 1" | |
13 | 2" x 1 1/4" | |
14 | 2" x 1 1/2" | |
15 | 3" x 1 1/2" | |
16 | 3" x 2" | |
17 | 4" x 2" | |
18 | 4" x 3" | |
19 | 6" x 3" | |
20 | 6" x 4" | |
21 | 8" x 4" | |
22 | 8" x 6" | |
23 | 10" x 6" | |
24 | 10" x 8" | |
25 | 12" x 6" | |
26 | 12" x 8" | |
27 | 12" x 10" | |
28 | 14" x 8" | |
29 | 14" x 10" | |
30 | 14" x 12" | |
31 | 16" x 8" | |
32 | 16" x 10" | |
33 | 16" x 12" | |
34 | 16" x 14" | |
35 | 18" x 10" | |
36 | 18" x 12" | |
37 | 18" x 14" | |
38 | 18" x 16" | |
39 | 20" x 10" | |
40 | 20" x 12" | |
41 | 20" x 14" | |
42 | 20" x 16" | |
43 | 20" x 18" | |
44 | 24" x 12" | |
45 | 24" x 14" | |
46 | 24" x 16" | |
47 | 24" x 18" | |
48 | 24" x 20" | |
49 | 26" x 14" | |
50 | 26" x 16" | |
51 | 26" x 18" | |
52 | 26" x 20" | |
53 | 26" x 24" | |
54 | 30" x 16" | |
55 | 30" x 18" | |
56 | 30" x 20" | |
57 | 30" x 24" | |
58 | 30" x 26" | |
59 | 36" x 18" | |
60 | 36" x 20" | |
61 | 36" x 24" | |
62 | 36" x 26" | |
63 | 40" x 20" | |
64 | 40" x 24" | |
65 | 40" x 26" | |
66 | 40" x 30" | |
67 | 40" x 36" | |
68 | 48" x 24" | |
69 | 48" x 26" | |
70 | 48" x 30" | |
71 | 48" x 36" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 6 | Reducer | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Region |
Description | List of Regions/Providences/States |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 51 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
U | Unknown | |
AL | Alabama | |
AK | Alaska | |
AR | Arkansas | |
AZ | Arizona | |
CA | California | |
CO | Colorado | |
CT | Connecticut | |
DE | Delaware | |
FL | Florida | |
GA | Georgia | |
HI | Hawaii | |
ID | Idaho | |
IL | Illinois | |
IN | Indiana | |
IA | Iowa | |
KS | Kansas | |
KY | Kentucky | |
LA | Louisiana | |
MA | Massachusetts | |
ME | Maine | |
MD | Maryland | |
MI | Michigan | |
MN | Minnesota | |
MO | Missouri | |
MS | Mississippi | |
MT | Montana | |
NE | Nebraska | |
NV | Nevada | |
NH | New Hampshire | |
NJ | New Jersey | |
NM | New Mexico | |
NY | New York | |
NC | North Carolina | |
ND | North Dakota | |
OH | Ohio | |
OK | Oklahoma | |
OR | Oregon | |
PA | Pennsylvania | |
RI | Rhode Island | |
SC | South Carolina | |
SD | South Dakota | |
TN | Tennessee | |
TX | Texas | |
UT | Utah | |
VT | Vermont | |
VA | Virginia | |
WA | Washington | |
WV | West Virginia | |
WI | Wisconsin | |
WY | Wyoming |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_ExcavationDamage | responsiblepartystate | ||
main.P_ExcavationDamage | incidentlocationstate |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Regulatory_Type |
Description | List of Pipeline regulatory types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 84 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Distribution | |
2 | Gathering | |
3 | Transmission | |
4 | Offshore Gathering | |
5 | Offshore Transmission |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Regulator_Casing_Material |
Description | List of valid types of material which can be used for regulator casing material |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unkown | Unknown | |
Aluminum | Aluminum | |
Cast Iron | Cast Iron | |
Ductile Iron | Ductile Iron | |
Steel | Steel |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 19 | Regulator | casingmaterial |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Regulator_Manufacturer |
Description | List of valid manufacturers of regulators |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
American | American | |
Fisher | Fisher | |
Grove | Grove | |
Reliance | Reliance | |
Rockwell | Rockwell | |
Singer | Singer | |
Sprague | Sprague | |
Universal Lancaster | Universal Lancaster | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Regulator_Model |
Description | List of valid type of manufacturer models of regulators |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | manufacturemodel |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Regulator_Type |
Description | List of valid type functions of regulators |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Controller | Controller | |
Monitor | Monitor |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_RegulatorInspect | regulatortype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Seam_Orientation |
Description | The list of seam types as clock positions |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 25 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.5 | 00:30 | |
1 | 01:00 | |
1.5 | 01:30 | |
2 | 02:00 | |
2.5 | 02:30 | |
3 | 03:00 | |
3.5 | 03:30 | |
4 | 04:00 | |
4.5 | 04:30 | |
5 | 05:00 | |
5.5 | 05:30 | |
6 | 06:00 | |
6.5 | 06:30 | |
7 | 07:00 | |
7.5 | 07:30 | |
8 | 08:00 | |
8.5 | 08:30 | |
9 | 09:00 | |
9.5 | 09:30 | |
10 | 10:00 | |
10.5 | 10:30 | |
11 | 11:00 | |
11.5 | 11:30 | |
12 | 12:00 |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Seam_Type |
Description | List of seam types used during the manufacture of the pipe |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Seamless | |
2 | Electric Weld | |
3 | Lap Weld | |
4 | Butt Weld | |
5 | Single Submerged Arc Weld | |
6 | Single Submerged Arc Weld Spiraled | |
7 | Double Submerged Arc Weld | |
8 | Double Submerged Arc Weld Spiraled | |
9 | Not Applicable |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Service_Summary_Pipe_Material |
Description | List of valid pipe materials |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bare Steel | |
2 | Cast Iron | |
3 | Coated Steel | |
4 | Copper | |
5 | Plastic PE | |
6 | Wrought Iron | |
7 | Ductile Iron | |
8 | Plastic PVC | |
9 | Composite | |
10 | Plastic ABS | |
11 | Reconditioned Cast Iron |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Strainer_Manufacturer |
Description | List of valid type of manufacturer models of strainers |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Eaton | Eaton | |
IMAC Systems | IMAC Systems | |
JORC Industrial | JORC Industrial | |
KADANT | KADANT | |
KITZ Corp | KITZ Corp | |
Mueller | Mueller | |
Spirax-Sarco | Spirax-Sarco | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StrainerInspect | strainermanufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Structure_Limited_Mobility |
Description | List of reasons a structure is designated as Limited Mobility |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Registered | Registered | |
Agency Map | Agency Map | |
Visibly Marked | Visibly Marked | |
On Agency Map and Visibly Marked | On Agency Map and Visibly Marked | |
Visibly Marked and Registered | Visibly Marked and Registered | |
Registered and Agency Map and Visibly Marked | Registered and Agency Map and Visibly Marked | |
Registered and Agency Map | Registered and Agency Map |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StructureFootPrint | limitedmobilityreason | ||
main.P_StructurePoint | limitedmobilityreason |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Structure_Type |
Description | List of the types of human occupied structures |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 20 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Apartment | Apartment | |
Arena | Arena | |
Assisted Living | Assisted Living | |
Barracks | Barracks | |
Business | Business | |
Daycare Facility | Daycare Facility | |
Fire Station | Fire Station | |
Garage | Garage | |
Hospital | Hospital | |
Hotel | Hotel | |
Industrial | Industrial | |
Manufacturing | Manufacturing | |
Nursing Home | Nursing Home | |
Prison | Prison | |
Recreational Facility | Recreational Facility | |
Religious Facility | Religious Facility | |
Residence | Residence | |
School | School | |
Shopping Center | Shopping Center |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_StructureFootPrint | structuretype | ||
main.P_StructurePoint | structuretype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Supplier |
Description | The valid names of the organizations supplying the natural gas at the town border station |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 13 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Surface_Type |
Description | List of valid types of cover over the buried gas asset |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 22 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
Above Grade | Above Grade | |
Above Ground | Above Ground | |
Agriculture Crop | Agriculture Crop | |
Asphalt | Asphalt | |
Bare | Bare | |
Concrete | Concrete | |
Grass | Grass | |
Gravel | Gravel |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Tank_Manufacturer |
Description | List of valid manufacturers of oil and gas storage tanks |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 14 | Tank | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Volume |
Description | List of valid units of measure of pipe volume |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 17 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
22 | Cubic Feet | |
21 | Cubic Inches | |
123 | Cubic Meters | |
122 | Cubic Centimeters |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Tank_Model |
Description | List of valid models of oil and gas storage tanks |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 14 | Tank | manufacturecomponent |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Tee_DesignType |
Description | List of types for pipeline tees |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
121 | Barred |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineJunction | 7 | Tee | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Transmission_Manufacturer |
Description | List of the types of manufacturer for transmission pipes |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
US Steel | US Steel |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineLine | 3 | Transmission Pipe | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Diameter |
Description | List of valid diameter sizes for valves |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 32 |
# of Assignments | 14 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
0.75 | 3/4" | |
1 | 1" | |
1.125 | 1 1/8" | |
1.25 | 1 1/4" | |
1.375 | 1 3/8" | |
1.5 | 1 1/2" | |
1.875 | 1 7/8" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
5 | 5" | |
5.5 | 5 1/2" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
26 | 26" | |
30 | 30" | |
36 | 36" | |
40 | 40" | |
48 | 48" |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Key_Size |
Description | Finite list for an existing attribute to limit freeform data entry |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | 1 | |
2 | 2 | |
3 | 3 | |
4 | 4 | |
5 | 5 | |
6 | 6 | |
7 | 7 | |
8 | 8 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 3 | Controllable Valve | valvekeysize |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Manufacturer |
Description | List of the types of manufacturer of valves |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
Apollo | Apollo | |
Balon | Balon | |
Dresser-Rand | Dresser-Rand | |
Georg Fischer | Georg Fischer | |
Jomar | Jomar | |
Kerotest | Kerotest | |
Mueller | Mueller | |
Rockford | Rockford | |
Other | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LineValveInspection | manufacturer | ||
main.P_ReliefValveInspection | manufacturer |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Model |
Description | List of the types of manufacturer models of valves |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.P_LineValveInspection | manufacturemodel | ||
main.P_ReliefValveInspection | manufacturemodel |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Valve_Status |
Description | The status of a valve device |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Closed | |
1 | Open |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | devicestatus | ||
main.PipelineDevice | 1 | Excess Flow Valve | devicestatus |
main.PipelineDevice | 3 | Controllable Valve | devicestatus |
main.PipelineDevice | 4 | Flow Valve | devicestatus |
main.PipelineDevice | 5 | Relief Valve | devicestatus |
main.PipelineDevice | 12 | Controllable Tee | devicestatus |
main.PipelineDevice | 13 | Line Stopper | devicestatus |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Wellhead_Connection_Type |
Description | List of valid types of connections for wellheads |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | connectiontype |
Key | Value |
---|---|
Owner | |
Domain Name | Pipeline_Wellhead_Material_Class |
Description | List of valid classifications of the wellhead material |
Field Type | String |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
Unknown | Unknown | |
AA | AA | |
BB | BB | |
CC | CC | |
DD | DD | |
EE | EE | |
FF | FF | |
HH | HH |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineAssembly | 6 | Wellhead | materialclass |
Key | Value |
---|---|
Owner | |
Domain Name | Spatial_Accuracy |
Description | Assessment of the spatial accuracy of the XY coordinates |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 85 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Greater than 300 Meters | |
3 | 31-100 Meters | |
4 | 11-30 Meters | |
5 | 1-10 Meters | |
6 | 0.3-1 Meter | |
7 | 11-29 Centimeters | |
8 | 1-10 Centimeters | |
9 | 1-9 Millimeters | |
10 | Less than 1 Millimeter |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Diameter |
Description | List of valid units of measure for pipe diameter |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 75 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Inch | |
2 | Feet | |
101 | Millimeter | |
104 | Meter |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Height |
Description | List of valid units of measure for structure height above ground surface |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Inch | |
2 | Feet | |
102 | Centimeter | |
104 | Meter |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.PipelineDevice | 9 | Lamp | heightunits |
main.PipelineJunction | 0 | Unknown | heightunits |
main.PipelineJunction | 14 | Tank | heightunits |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Length |
Description | List of valid types of measures of length |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 65 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | Feet | |
5 | Mile | |
104 | Meter | |
107 | Kilometer |
Key | Value |
---|---|
Owner | |
Domain Name | Units_for_Pressure |
Description | List of valid units of measure of pressure |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 89 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
231 | Pounds/Square Inch | |
232 | Inch Water Column | |
233 | Bar | |
234 | Millibar | |
235 | Pascal | |
236 | Kilopascal |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Error Phase |
Description | Indicates error lifecycle phase of an error |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
2 | Review | |
4 | Correction | |
6 | Verification |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Error Status |
Description | Indicates error lifecycle status of an error |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Reviewed | |
2 | Resolved | |
3 | Mark As Exception | |
4 | Acceptable | |
6 | Unacceptable | |
9 | Exception |
Key | Value |
---|---|
Owner | |
Domain Name | VerticalAlignment |
Description | Valid symbol vertical alignment values. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Top | |
1 | Center | |
2 | Baseline | |
3 | Bottom |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsConnected |
Description | Indicates if the feature is connected to a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 73 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True | |
2 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierName |
Description | The tier names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 25 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Cathodic Protection | |
2 | System | |
3 | Pressure | |
4 | Isolation |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TerminalNames |
Description | The terminal names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 18 |
# of Assignments | 32 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Single Terminal | |
2 | High Pressure In | |
3 | Low Pressure Out | |
4 | Low Pressure In | |
5 | High Pressure Out | |
6 | Inlet Port | |
7 | Outlet Port | |
8 | Port One | |
9 | Port Two | |
10 | Terminal One | |
11 | Terminal Two | |
12 | Terminal Three | |
13 | Terminal Four | |
14 | Terminal Five | |
15 | Terminal Six | |
16 | Terminal Seven | |
17 | Terminal Eight |
Key | Value |
---|---|
Owner | |
Domain Name | AP_Configure_Categories |
Description | Valid values for D_Configuration table |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Not Evaluated | |
1 | Evaluated | |
2 | Exclusive | |
3 | Remove when applied | |
4 | Always remove when applied | |
5 | Keep when applied | |
6 | Always keep when applied |