Key | Value |
---|---|
Name | Electric_Essentials_UtilityNetwork.geodatabase |
Workspace Type | Local Database |
Workspace Factory | Sqlite |
Geodatabase Release | 3.0.0 |
Date Exported | 2024-08-01 |
Path |
Name | Dataset Type | Feature Dataset | Dataset ID |
---|---|---|---|
main.Essentials_UtilityNetwork | FeatureDataset | ||
main.StructureBoundary | FeatureClass | main.Essentials_UtilityNetwork | 38 |
main.ServiceTerritory | FeatureClass | main.Essentials_UtilityNetwork | 5 |
main.ElectricAssembly | FeatureClass | main.Essentials_UtilityNetwork | 267 |
main.StructureLine | FeatureClass | main.Essentials_UtilityNetwork | 37 |
main.Network | UtilityNetwork | main.Essentials_UtilityNetwork | 6 |
main.StructureJunction | FeatureClass | main.Essentials_UtilityNetwork | 34 |
main.ElectricSubnetLine | FeatureClass | main.Essentials_UtilityNetwork | 269 |
main.ElectricDevice | FeatureClass | main.Essentials_UtilityNetwork | 264 |
main.ElectricJunction | FeatureClass | main.Essentials_UtilityNetwork | 268 |
main.ElectricLine | FeatureClass | main.Essentials_UtilityNetwork | 266 |
main.StructureJunctionObject | Table | 39 | |
main.StructureEdgeObject | Table | 40 | |
main.ElectricJunctionObject | Table | 270 | |
main.ElectricEdgeObject | Table | 271 |
Key | Value |
---|---|
Name | main.Essentials_UtilityNetwork |
Dataset Type | FeatureDataset |
Feature Dataset | |
Dataset ID | |
# of Children | 10 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | |
Y-Min | |
X-Max | |
Y-Max |
Name | Dataset Type | Feature Dataset | Dataset ID |
---|---|---|---|
main.StructureBoundary | FeatureClass | main.Essentials_UtilityNetwork | 38 |
main.ServiceTerritory | FeatureClass | main.Essentials_UtilityNetwork | 5 |
main.ElectricAssembly | FeatureClass | main.Essentials_UtilityNetwork | 267 |
main.StructureLine | FeatureClass | main.Essentials_UtilityNetwork | 37 |
main.Network | UtilityNetwork | main.Essentials_UtilityNetwork | 6 |
main.StructureJunction | FeatureClass | main.Essentials_UtilityNetwork | 34 |
main.ElectricSubnetLine | FeatureClass | main.Essentials_UtilityNetwork | 269 |
main.ElectricDevice | FeatureClass | main.Essentials_UtilityNetwork | 264 |
main.ElectricJunction | FeatureClass | main.Essentials_UtilityNetwork | 268 |
main.ElectricLine | FeatureClass | main.Essentials_UtilityNetwork | 266 |
Key | Value |
---|---|
Name | main.StructureBoundary |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 38 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | StructureBoundary |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {09048202-E15A-4F53-A25E-1B761442A9E2} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Boundary feature class represents features whose outline should be display on a map view or container view. Structure boundaries can contain structure edges, structure junctions, devices, lines, assemblies, and junctions. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
name | Name | String | True | 0 | 0 | 64 | True | False | The name of the facility, like a station name | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
st_area(SHAPE) | SHAPE_Area | Double | Area | True | 0 | 0 | 0 | False | True | |||
st_perimeter(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_38_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_40 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureBoundary_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the Structure Boundary feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Electric Substation Boundary | 102 | Electric Substation Boundary features are polygon features that outline of a Substation. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
Electric Substation Boundary | 102 | ASSETTYPE | 0 | Asset_Type_Structure_Boundary_Electric_Substation_Boundary | |
Electric Substation Boundary | 102 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Electric Substation Boundary | 102 | SUBNETWORKNAME | Unknown | ||
Electric Substation Boundary | 102 | constructionstatus | 6 | Construction_Status | |
Electric Substation Boundary | 102 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.ServiceTerritory |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 5 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ServiceTerritory |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | |
Default Subtype | |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | Shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048939.1188046746 |
Y-Min | 1859263.4819603562 |
X-Max | 1060739.2369366772 |
Y-Max | 1874460.758980438 |
Catalog ID | {1BC1DA35-914D-4190-B88F-18951016FBF1} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The networks service territory that represents the operational area of the utility. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
COMPANYNAME | Company Name | String | True | 0 | 0 | 50 | True | False | The company name of this service area polygon | |||
GLOBALID | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
DISTRICTNAME | District Name | String | True | 0 | 0 | 50 | True | False | The name of the district | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | ||||
st_area(Shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(Shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_9 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ServiceTerritory_Shape | True | True | Shape |
Key | Value |
---|---|
Name | main.ElectricAssembly |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 267 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ElectricAssembly |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {31213044-BA29-455D-8DC3-30601CB01F0B} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Assembly feature class represents complex point features which contain other devices and lines. Like device features, assembly features are compact features but they differ in that assemblies contain other significant devices. Assemblies are useful to show a single symbol on the map yet model the internal features and their connections. Assemblies can contain devices, lines, and junctions. You can view the internal features of an assembly on the map or in the diagram view. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
retireddate | Retired Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was retired or taken out of service | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | The angle the symbol should be rotated by | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
model | Model | String | True | 0 | 0 | 255 | True | False | The manufacturers model number or identifier of the equipment | |||
manufacturer | Manufacturer | Short Integer | True | 0 | 0 | 2 | True | False | The name of the equipment manufacturer |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_267_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
UUID_45 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricAssembly_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Switch Gear | 18 | A collection of equipment used for medium Voltage switches. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
Unknown | 0 | symbolrotation | Symbol_Rotation | ||
Switch Gear | 18 | ASSETTYPE | 0 | Asset_Type_Electric_Assembly_Medium_Voltage_Switch_Bank | |
Switch Gear | 18 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Switch Gear | 18 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
Switch Gear | 18 | constructionstatus | 6 | Construction_Status | |
Switch Gear | 18 | lifecyclestatus | 2 | Lifecycle_Status | |
Switch Gear | 18 | symbolrotation | Symbol_Rotation |
Key | Value |
---|---|
Name | main.StructureLine |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 37 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | StructureLine |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {6DAA2EE5-DDC0-4528-9100-CFD6E5F10340} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Line contain lines which carry a resource. Structure lines participating as containers can contain other structure lines. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
diameter | diameter: Diameter, Width | Double | True | Wire_Duct_Diameter | 0 | 0 | 8 | True | False | The diameter of the duct or conduit | ||
materialcode | materialcode: Material, Soil Type | Short Integer | True | 0 | 0 | 2 | True | False | The code used for describing the material used in this structure | |||
distance | Depth | Double | True | 0 | 0 | 8 | True | False | A search distance field used in an attribute rule | |||
labeltext | Labeling String | String | True | 0 | 0 | 256 | True | False | A free form field that can be used in labeling | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
retireddate | Retired Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was retired or taken out of service | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
notes | General Notes | String | True | 0 | 0 | 2000 | True | False | A free form notes field | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_37_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_39 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Wire Aerial Support | 103 | Electric Aerial supports include Guy Wires and Bridge support type features. |
Wire Trench | 104 | An Electric Trench is an open ditch that electric wires will be buried in, typically direct bury cable. |
Electric Low Voltage Conduit | 106 | Conduit, typically plastic, that are used to protect underground low voltage electric lines, for example the low voltage line that services residential power to a home. |
Electric Medium Voltage Conduit | 107 | Conduit, typically plastic, that are used to protect underground medium voltage electric lines, for example medium voltage lines may run from overhead to underground inside of conduit. |
Key | Value |
---|---|
Name | main.Network |
Dataset Type | UtilityNetwork |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 6 |
Schema Generation | 7 |
Pro Version | ArcGIS Pro 3.3.1 |
User Identity | |
Creation Time | 2024-07-31 09:39:40 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Service Territory | main.ServiceTerritory |
Domain Network Name | Domain Network Alias | Domain Network ID | Tier Definition | Subnetwork Controller Type | Creation Time |
---|---|---|---|---|---|
Structure | Structure | 1 | None | 2024-07-31 09:39:40 | |
Electric | Electric | 2 | Partitioned | Source | 2024-07-31 09:42:18 |
Domain Network Name | Tier Group Name | Tier Name | Tier ID | Tier Rank | Tier Topology | Diagram Templates | Supports Disjoint | Subnetwork Field Name | Edit Mode in Default | Edit Mode in Version | Update Structures | Update Containers | Validate Locatability | Manage isDirty | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electric | Electric Distribution | 1 | 1 | Mesh | True | Without Eventing | Without Eventing | True | True | False | True | 2024-07-31 09:42:38 |
Tier Name | Source Name | Asset Group | Asset Type | Controller / Aggregated |
---|---|---|---|---|
Electric Distribution | Device | High Voltage Transformer | Power Transformer HV->MV | True |
Electric Distribution | Device | Capacitor | Overhead Bank | False |
Electric Distribution | Device | Capacitor | Underground Bank | False |
Electric Distribution | Device | Capacitor | Station Bank | False |
Electric Distribution | Device | Circuit Breaker | Three Phase Circuit Breaker | False |
Electric Distribution | Device | Circuit Breaker | Circuit Source | True |
Electric Distribution | Device | Elbow | Underground Bank | False |
Electric Distribution | Device | Fuse | Overhead Bank | False |
Electric Distribution | Device | Fuse | Underground Bank | False |
Electric Distribution | Device | Fuse | Station Bank | False |
Electric Distribution | Device | Generation | Interconnect | True |
Electric Distribution | Device | Line Monitor and Relay | Fault Indicator | False |
Electric Distribution | Device | Line Monitor and Relay | Instrument Transformer | False |
Electric Distribution | Device | Line Monitor and Relay | Relay | False |
Electric Distribution | Device | Motor and Pump | Single Phase Motor | False |
Electric Distribution | Device | Motor and Pump | Single Phase Pump | False |
Electric Distribution | Device | Motor and Pump | Three Phase Motor | False |
Electric Distribution | Device | Motor and Pump | Three Phase Pump | False |
Electric Distribution | Device | Voltage Regulator | Overhead Bank | False |
Electric Distribution | Device | Voltage Regulator | Underground Bank | False |
Electric Distribution | Device | Voltage Regulator | Station Bank | False |
Electric Distribution | Device | Primary Service | Primary Meter | False |
Electric Distribution | Device | Recloser | Overhead Bank | False |
Electric Distribution | Device | Recloser | Underground Bank | False |
Electric Distribution | Device | Recloser | Overhead Recloser - Controller | True |
Electric Distribution | Device | Recloser | Pad Mounted Recloser - Controller | True |
Electric Distribution | Device | Sectionalizer | Overhead Bank | False |
Electric Distribution | Device | Sectionalizer | Underground Bank | False |
Electric Distribution | Device | Switch | Overhead Bank | False |
Electric Distribution | Device | Switch | Underground Bank | False |
Electric Distribution | Device | Switch | Station Bank | False |
Electric Distribution | Device | Transformer | Overhead Single Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Overhead Three Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Pad Mounted Single Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Pad Mounted Three Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Submersible Single Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Submersible Three Phase - MV->LV | True |
Electric Distribution | Device | Transformer | Overhead Open Delta - MV->LV | True |
Electric Distribution | Device | Transformer | Overhead Open Wye - MV->LV | True |
Electric Distribution | Device | Transformer | Pad Mounted Open Delta - MV->LV | True |
Electric Distribution | Device | Transformer | Pad Mounted Open Wye - MV->LV | True |
Electric Distribution | Device | Transformer | Overhead Single Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Overhead Three Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Pad Mounted Single Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Pad Mounted Three Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Submersible Single Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Submersible Three Phase Step - MV->MV | True |
Electric Distribution | Device | Transformer | Overhead Three Phase Step Up - LV->MV | True |
Electric Distribution | Device | Transformer | Pad Mounted Three Phase Step Up - LV->MV | True |
Electric Distribution | Device | Transformer | Overhead Single Phase Step Up - LV->MV | False |
Electric Distribution | Device | Transformer | Pad Mounted Single Phase Step Up - LV->MV | False |
Electric Distribution | Device | Low Voltage Fuse | Overhead Bank | False |
Electric Distribution | Device | Low Voltage Fuse | Underground Bank | False |
Electric Distribution | Device | Low Voltage Fuse | Station Bank | False |
Electric Distribution | Device | Low Voltage Generation | Residential Photovoltaic Solar LV | False |
Electric Distribution | Device | Low Voltage Lighting | Floodlight LV | False |
Electric Distribution | Device | Low Voltage Lighting | Streetlight LV | False |
Electric Distribution | Device | Low Voltage Motor | Single Phase Motor LV | False |
Electric Distribution | Device | Low Voltage Motor | Three Phase Motor LV | False |
Electric Distribution | Device | Low Voltage Service | Low Voltage Premise LV | False |
Electric Distribution | Device | Low Voltage Switch | Overhead Bank | False |
Electric Distribution | Device | Low Voltage Switch | Underground Bank | False |
Electric Distribution | Device | Low Voltage Switch | Station Bank | False |
Electric Distribution | Line | Medium Voltage Overhead Conductor | Unknown | False |
Electric Distribution | Line | Medium Voltage Overhead Conductor | Overhead Single Phase | True |
Electric Distribution | Line | Medium Voltage Overhead Conductor | Overhead Three Phase | True |
Electric Distribution | Line | Medium Voltage Overhead Conductor | Overhead Two Phase | True |
Electric Distribution | Line | Medium Voltage Overhead Conductor | Overhead Neutral | False |
Electric Distribution | Line | Medium Voltage Connector | Unknown | False |
Electric Distribution | Line | Medium Voltage Connector | Single Phase | True |
Electric Distribution | Line | Medium Voltage Connector | Three Phase | True |
Electric Distribution | Line | Medium Voltage Connector | Two Phase | True |
Electric Distribution | Line | Medium Voltage Underground Conductor | Unknown | False |
Electric Distribution | Line | Medium Voltage Underground Conductor | Underground Single Phase | True |
Electric Distribution | Line | Medium Voltage Underground Conductor | Underground Three Phase | True |
Electric Distribution | Line | Medium Voltage Underground Conductor | Underground Two Phase | True |
Electric Distribution | Line | Medium Voltage Submersible Conductor | Unknown | False |
Electric Distribution | Line | Medium Voltage Submersible Conductor | Submersible Single Phase | True |
Electric Distribution | Line | Medium Voltage Submersible Conductor | Submersible Three Phase | True |
Electric Distribution | Line | Medium Voltage Busbar | Unknown | False |
Electric Distribution | Line | Medium Voltage Busbar | Cabinet Single Phase | False |
Electric Distribution | Line | Medium Voltage Busbar | Cabinet Three Phase | False |
Electric Distribution | Line | Medium Voltage Busbar | Station Three Phase | True |
Electric Distribution | Line | Low Voltage Underground Conductor | Unknown | False |
Electric Distribution | Line | Low Voltage Underground Conductor | Underground LV | False |
Electric Distribution | Line | Low Voltage Service | Unknown | False |
Electric Distribution | Line | Low Voltage Service | Overhead Service LV | False |
Electric Distribution | Line | Low Voltage Service | Underground Service LV | False |
Electric Distribution | Line | Low Voltage Overhead Conductor | Unknown | False |
Electric Distribution | Line | Low Voltage Overhead Conductor | Overhead LV | False |
Electric Distribution | Line | Low Voltage Submersible Conductor | Unknown | False |
Electric Distribution | Line | Low Voltage Submersible Conductor | Submersible LV | False |
Electric Distribution | Junction | Medium Voltage Attachment | Overhead | |
Electric Distribution | Junction | Medium Voltage Attachment | Underground | |
Electric Distribution | Junction | Medium Voltage Attachment | Submersible | |
Electric Distribution | Junction | Medium Voltage Connection Point | Busbar Tap | |
Electric Distribution | Junction | Medium Voltage Connection Point | Overhead Tap | |
Electric Distribution | Junction | Medium Voltage Connection Point | Neutral Connection | |
Electric Distribution | Junction | Medium Voltage Connection Point | Underground Tap | |
Electric Distribution | Junction | Medium Voltage Line End | Overhead Splice | |
Electric Distribution | Junction | Medium Voltage Line End | Underground Splice | |
Electric Distribution | Junction | Medium Voltage Line End | Overhead Line End | |
Electric Distribution | Junction | Medium Voltage Line End | Underground Terminator | |
Electric Distribution | Junction | Medium Voltage Line End | Overhead Wire Change | |
Electric Distribution | Junction | Medium Voltage Line End | Underground Wire Change | |
Electric Distribution | Junction | Medium Voltage Line End | Open Point | |
Electric Distribution | Junction | Low Voltage Attachment | Overhead LV | |
Electric Distribution | Junction | Low Voltage Attachment | Underground LV | |
Electric Distribution | Junction | Low Voltage Attachment | Submersible LV | |
Electric Distribution | Junction | Low Voltage Connection Point | Busbar Tap LV | |
Electric Distribution | Junction | Low Voltage Connection Point | Overhead Tap LV | |
Electric Distribution | Junction | Low Voltage Connection Point | Underground Tap LV | |
Electric Distribution | Junction | Low Voltage Line End | Overhead Splice LV | |
Electric Distribution | Junction | Low Voltage Line End | Underground Splice LV | |
Electric Distribution | Junction | Low Voltage Line End | Overhead Line End LV | |
Electric Distribution | Junction | Low Voltage Line End | Underground Terminator LV | |
Electric Distribution | Junction | Low Voltage Line End | Overhead Wire Change LV | |
Electric Distribution | JunctionObject | Voltage Regulator | Overhead | False |
Electric Distribution | JunctionObject | Voltage Regulator | Underground | False |
Electric Distribution | JunctionObject | Medium Voltage Control Unit | Capacitor | False |
Electric Distribution | JunctionObject | Medium Voltage Control Unit | Circuit Breaker | False |
Electric Distribution | JunctionObject | Medium Voltage Control Unit | Recloser | False |
Electric Distribution | JunctionObject | Medium Voltage Control Unit | Transfer Switch Controller | False |
Electric Distribution | JunctionObject | Medium Voltage Control Unit | Regulator | False |
Electric Distribution | JunctionObject | Primary Service | Primary Meter - Industrial Customer MV | False |
Electric Distribution | JunctionObject | Primary Service | Primary Meter - Utility Customer MV | False |
Electric Distribution | JunctionObject | Primary Service | Primary Meter | False |
Electric Distribution | JunctionObject | Elbow | AC Underground | False |
Electric Distribution | JunctionObject | Fuse | AC Overhead | False |
Electric Distribution | JunctionObject | Fuse | AC Underground | False |
Electric Distribution | JunctionObject | Line Monitor and Relay | Fault Indicator | False |
Electric Distribution | JunctionObject | Line Monitor and Relay | Instrument Transformer | False |
Electric Distribution | JunctionObject | Line Monitor and Relay | Relay | False |
Electric Distribution | JunctionObject | Motor and Pump | Single Phase Motor | False |
Electric Distribution | JunctionObject | Motor and Pump | Single Phase Pump | False |
Electric Distribution | JunctionObject | Motor and Pump | Three Phase Motor | False |
Electric Distribution | JunctionObject | Motor and Pump | Three Phase Pump | False |
Electric Distribution | JunctionObject | Capacitor | Overhead | False |
Electric Distribution | JunctionObject | Capacitor | Underground | False |
Electric Distribution | JunctionObject | Recloser | Overhead | False |
Electric Distribution | JunctionObject | Recloser | Underground | False |
Electric Distribution | JunctionObject | Recloser | Overhead - Controller | False |
Electric Distribution | JunctionObject | Recloser | Underground - Controller | False |
Electric Distribution | JunctionObject | Recloser | Overhead Three Phase Recloser - Controller | True |
Electric Distribution | JunctionObject | Recloser | Pad Mounted Recloser - Controller | True |
Electric Distribution | JunctionObject | Sectionalizer | Overhead | False |
Electric Distribution | JunctionObject | Sectionalizer | Underground | False |
Electric Distribution | JunctionObject | Switch | Overhead | False |
Electric Distribution | JunctionObject | Switch | Underground | False |
Electric Distribution | JunctionObject | Transformer | Overhead Single Phase - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Station - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Overhead Three Phase - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Pad Mounted Single Phase - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Pad Mounted Three Phase - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Submersible Three Phase - MV->LV | False |
Electric Distribution | JunctionObject | Transformer | Overhead Single Phase Step - MV->MV | False |
Electric Distribution | JunctionObject | Transformer | Overhead Three Phase Step - MV->MV | False |
Electric Distribution | JunctionObject | Transformer | Pad Mounted Three Phase Step - MV->MV | False |
Electric Distribution | JunctionObject | Transformer | Station Step - MV->MV | False |
Electric Distribution | JunctionObject | Transformer | Overhead Three Phase Step Up - LV->MV | False |
Electric Distribution | JunctionObject | Transformer | Overhead Single Phase Step Up - LV->MV | False |
Electric Distribution | JunctionObject | Transformer | Pad Mounted Single Phase Step Up - LV->MV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Single Phase Commercial LV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Single Phase Residential LV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Three Phase Commercial LV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Three Phase Residential LV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Unmetered Load LV | False |
Electric Distribution | JunctionObject | Low Voltage Service | Car Charger LV | False |
Electric Distribution | EdgeObject | Aerial Bare | Medium Voltage | |
Electric Distribution | EdgeObject | Aerial Bare | Low Voltage AC | |
Electric Distribution | EdgeObject | Connector | Medium Voltage | |
Electric Distribution | EdgeObject | Connector | Low Voltage AC | |
Electric Distribution | EdgeObject | Aerial Covered | Medium Voltage | |
Electric Distribution | EdgeObject | Aerial Covered | Low Voltage AC | |
Electric Distribution | EdgeObject | Busbar | Medium Voltage | |
Electric Distribution | EdgeObject | Busbar | Low Voltage AC | |
Electric Distribution | EdgeObject | Underground | Medium Voltage | |
Electric Distribution | EdgeObject | Underground | Low Voltage AC | |
Electric Distribution | EdgeObject | Neutral | Overhead Bare | |
Electric Distribution | EdgeObject | Neutral | Overhead Shielded | |
Electric Distribution | EdgeObject | Neutral | Underground Shielded | |
Electric Distribution | EdgeObject | Neutral | Concentric | |
Electric Distribution | EdgeObject | Submarine | Medium Voltage | |
Electric Distribution | EdgeObject | Submarine | Low Voltage AC |
Tier Name | Include Containers | Include Content | Include Structures | Include Barriers | Validate Locatability | Traversability Scope |
---|---|---|---|---|---|---|
Electric Distribution | True | True | True | True | False | junctionsAndEdges |
Tier Name | Network Attribute / Category | Operator | Value | Combine Using Or |
---|---|---|---|---|
Electric Distribution | E:Operating Status Normal | Equal | 1 | True |
Electric Distribution | Lifecycle Status | Does Not Include Any | 6 | True |
Electric Distribution | Category | Equal | E:Ground | True |
Electric Distribution | Category | Equal | E:Open Point | True |
Electric Distribution | E:Operating Status Normal | Equal | 2 | False |
Tier Name | Function | Network Attribute | Operator | Value | Substitution | Propagated Field |
---|---|---|---|---|---|---|
Electric Distribution | Bitwise And | E:Phases Propagated | Includes Any | 7 | phasesenergized |
Domain Network Name | Source Name | Table | Usage Type | Source ID | # of Asset Groups | # of Asset Types |
---|---|---|---|---|---|---|
Structure | StructureJunction | main.StructureJunction | Structure Junction | 4 | 12 | 35 |
Structure | StructureBoundary | main.StructureBoundary | Structure Boundary | 6 | 2 | 3 |
Structure | StructureJunctionObject | main.StructureJunctionObject | Structure Junction Object | 7 | 2 | 5 |
Structure | StructureLine | main.StructureLine | Structure Line | 5 | 5 | 11 |
Structure | StructureEdgeObject | main.StructureEdgeObject | Structure Edge Object | 8 | 1 | 1 |
Electric | ElectricDevice | main.ElectricDevice | Device | 9 | 21 | 84 |
Electric | ElectricAssembly | main.ElectricAssembly | Assembly | 11 | 2 | 3 |
Electric | ElectricJunction | main.ElectricJunction | Junction | 12 | 7 | 32 |
Electric | ElectricJunctionObject | main.ElectricJunctionObject | Junction Object | 14 | 14 | 65 |
Electric | ElectricLine | main.ElectricLine | Line | 10 | 10 | 30 |
Electric | ElectricSubnetLine | main.ElectricSubnetLine | Subnet Line | 13 | 2 | 0 |
Electric | ElectricEdgeObject | main.ElectricEdgeObject | Edge Object | 15 | 8 | 25 |
Source Name | Asset Group Name | Asset Group Code | # of Asset Types | Creation Time |
---|---|---|---|---|
StructureJunction | Unknown | 0 | 1 | 2024-07-31 09:39:41 |
StructureJunction | Wire Cabinet | 101 | 2 | 2024-07-31 09:42:42 |
StructureJunction | Wire Structure Guy | 102 | 2 | 2024-07-31 09:42:42 |
StructureJunction | Wire Handhole | 103 | 2 | 2024-07-31 09:42:42 |
StructureJunction | Wire Junction Box | 104 | 2 | 2024-07-31 09:42:42 |
StructureJunction | Wire Vault | 110 | 3 | 2024-07-31 09:42:42 |
StructureJunction | Wire Pedestal | 107 | 2 | 2024-07-31 09:42:42 |
StructureJunction | Electric High Voltage Pole | 120 | 3 | 2024-07-31 09:42:42 |
StructureJunction | Electric Medium Voltage Pole | 121 | 4 | 2024-07-31 09:42:42 |
StructureJunction | Electric Low Voltage Pole | 122 | 3 | 2024-07-31 09:42:42 |
StructureJunction | Wire Support Pole | 123 | 4 | 2024-07-31 09:42:42 |
StructureJunction | Marker | 124 | 7 | 2024-07-31 09:42:42 |
StructureBoundary | Unknown | 0 | 1 | 2024-07-31 09:39:41 |
StructureBoundary | Electric Substation Boundary | 102 | 2 | 2024-07-31 09:42:48 |
StructureJunctionObject | Unknown | 0 | 1 | 2024-07-31 09:39:41 |
StructureJunctionObject | Pole | 120 | 4 | 2024-07-31 09:42:51 |
StructureLine | Unknown | 0 | 1 | 2024-07-31 09:39:41 |
StructureLine | Wire Aerial Support | 103 | 4 | 2024-07-31 09:42:54 |
StructureLine | Wire Trench | 104 | 2 | 2024-07-31 09:42:54 |
StructureLine | Electric Low Voltage Conduit | 106 | 2 | 2024-07-31 09:42:54 |
StructureLine | Electric Medium Voltage Conduit | 107 | 2 | 2024-07-31 09:42:54 |
StructureEdgeObject | Unknown | 0 | 1 | 2024-07-31 09:39:41 |
ElectricDevice | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricDevice | High Voltage Transformer | 11 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Circuit Breaker | 26 | 3 | 2024-07-31 09:43:05 |
ElectricDevice | Elbow | 28 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Fuse | 29 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Generation | 30 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Line Monitor and Relay | 31 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Motor and Pump | 32 | 5 | 2024-07-31 09:43:05 |
ElectricDevice | Capacitor | 34 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Voltage Regulator | 35 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Primary Service | 36 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Recloser | 41 | 5 | 2024-07-31 09:43:05 |
ElectricDevice | Sectionalizer | 42 | 3 | 2024-07-31 09:43:05 |
ElectricDevice | Switch | 37 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Transformer | 38 | 21 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Fuse | 14 | 4 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Generation | 15 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Lighting | 16 | 3 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Motor | 18 | 3 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Service | 22 | 2 | 2024-07-31 09:43:05 |
ElectricDevice | Low Voltage Switch | 23 | 4 | 2024-07-31 09:43:05 |
ElectricAssembly | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricAssembly | Switch Gear | 18 | 2 | 2024-07-31 09:43:25 |
ElectricJunction | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricJunction | Medium Voltage Attachment | 7 | 4 | 2024-07-31 09:43:29 |
ElectricJunction | Medium Voltage Connection Point | 8 | 5 | 2024-07-31 09:43:29 |
ElectricJunction | Medium Voltage Line End | 9 | 8 | 2024-07-31 09:43:29 |
ElectricJunction | Low Voltage Attachment | 4 | 4 | 2024-07-31 09:43:29 |
ElectricJunction | Low Voltage Connection Point | 5 | 4 | 2024-07-31 09:43:29 |
ElectricJunction | Low Voltage Line End | 6 | 6 | 2024-07-31 09:43:29 |
ElectricJunctionObject | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricJunctionObject | Medium Voltage Control Unit | 27 | 6 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Elbow | 28 | 2 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Fuse | 29 | 3 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Line Monitor and Relay | 31 | 4 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Motor and Pump | 32 | 5 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Capacitor | 34 | 3 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Voltage Regulator | 35 | 3 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Primary Service | 36 | 4 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Recloser | 41 | 7 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Sectionalizer | 42 | 3 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Switch | 37 | 3 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Transformer | 38 | 14 | 2024-07-31 09:43:38 |
ElectricJunctionObject | Low Voltage Service | 22 | 7 | 2024-07-31 09:43:38 |
ElectricLine | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricLine | Medium Voltage Overhead Conductor | 9 | 5 | 2024-07-31 09:43:53 |
ElectricLine | Medium Voltage Underground Conductor | 34 | 4 | 2024-07-31 09:43:53 |
ElectricLine | Medium Voltage Submersible Conductor | 35 | 3 | 2024-07-31 09:43:53 |
ElectricLine | Medium Voltage Busbar | 8 | 4 | 2024-07-31 09:43:53 |
ElectricLine | Medium Voltage Connector | 10 | 4 | 2024-07-31 09:43:53 |
ElectricLine | Low Voltage Service | 13 | 3 | 2024-07-31 09:43:53 |
ElectricLine | Low Voltage Overhead Conductor | 6 | 2 | 2024-07-31 09:43:53 |
ElectricLine | Low Voltage Underground Conductor | 37 | 2 | 2024-07-31 09:43:53 |
ElectricLine | Low Voltage Submersible Conductor | 38 | 2 | 2024-07-31 09:43:53 |
ElectricSubnetLine | Unknown | 0 | 0 | 2024-07-31 09:42:19 |
ElectricSubnetLine | Electric Distribution | 1 | 0 | 2024-07-31 09:42:42 |
ElectricEdgeObject | Unknown | 0 | 1 | 2024-07-31 09:42:19 |
ElectricEdgeObject | Aerial Bare | 101 | 4 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Aerial Covered | 102 | 3 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Busbar | 104 | 3 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Underground | 105 | 3 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Neutral | 106 | 5 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Submarine | 108 | 3 | 2024-07-31 09:44:05 |
ElectricEdgeObject | Connector | 109 | 3 | 2024-07-31 09:44:05 |
Source Name | Asset Group Name | Asset Type Name | Asset Group Code | Asset Type Code | Terminal Configuration | Association Role | Delete Type | Containment Scale | Split Content | Connectivity Policy | Network Categories | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|
StructureJunction | Unknown | Unknown | 0 | 0 | 2024-07-31 09:39:41 | |||||||
StructureJunction | Wire Cabinet | Unknown | 101 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Cabinet | Electric Cabinet | 101 | 101 | Container | Restricted | 10 | STR:Cable Support | 2024-07-31 09:42:42 | |||
StructureJunction | Wire Structure Guy | Unknown | 102 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Structure Guy | Anchor Guy | 102 | 41 | Container | Restricted | 10 | 2024-07-31 09:42:42 | ||||
StructureJunction | Wire Handhole | Unknown | 103 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Handhole | Handhole | 103 | 81 | Structure | Cascade | STR:Cable Support;STR:Duct Trace | 2024-07-31 09:42:42 | ||||
StructureJunction | Wire Junction Box | Unknown | 104 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Junction Box | Junction Box | 104 | 121 | Structure | Restricted | STR:Cable Support | 2024-07-31 09:42:42 | ||||
StructureJunction | Wire Vault | Unknown | 110 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Vault | Vault | 110 | 361 | Container | Restricted | 50 | STR:Cable Support;STR:Duct Trace | 2024-07-31 09:42:42 | |||
StructureJunction | Wire Vault | Manhole | 110 | 362 | Container | Restricted | 50 | STR:Cable Support;STR:Duct Trace | 2024-07-31 09:42:42 | |||
StructureJunction | Wire Pedestal | Unknown | 107 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Pedestal | Pedestal | 107 | 241 | Structure | Restricted | STR:Cable Support | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric High Voltage Pole | Unknown | 120 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Electric High Voltage Pole | H-Frame HV | 120 | 335 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric High Voltage Pole | Pole HV | 120 | 337 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric Medium Voltage Pole | Unknown | 121 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Electric Medium Voltage Pole | H-Frame MV | 121 | 321 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric Medium Voltage Pole | Primary Pole | 121 | 324 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric Medium Voltage Pole | Lattice | 121 | 329 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric Low Voltage Pole | Unknown | 122 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Electric Low Voltage Pole | Pole LV | 122 | 314 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Electric Low Voltage Pole | Ornamental LV | 122 | 315 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:42 | ||||
StructureJunction | Wire Support Pole | Unknown | 123 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Wire Support Pole | Stub | 123 | 326 | Structure | Restricted | 2024-07-31 09:42:42 | |||||
StructureJunction | Wire Support Pole | Push Brace | 123 | 327 | Structure | Restricted | 2024-07-31 09:42:42 | |||||
StructureJunction | Wire Support Pole | Support Column | 123 | 328 | Structure | Restricted | 2024-07-31 09:42:42 | |||||
StructureJunction | Marker | Unknown | 124 | 0 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Marker | Aerial Marker | 124 | 461 | Structure | Set To None | 2024-07-31 09:42:42 | |||||
StructureJunction | Marker | Buried Cable Marker | 124 | 462 | Structure | Set To None | 2024-07-31 09:42:42 | |||||
StructureJunction | Marker | Overhead Water Crossing | 124 | 463 | Structure | Set To None | E:Cable - Overhead | 2024-07-31 09:42:42 | ||||
StructureJunction | Marker | Submerged Cable Marker | 124 | 464 | Structure | Set To None | 2024-07-31 09:42:42 | |||||
StructureJunction | Marker | Covered Marker | 124 | 465 | 2024-07-31 09:42:42 | |||||||
StructureJunction | Marker | Terrain Marker | 124 | 466 | Structure | Restricted | 2024-07-31 09:42:42 | |||||
StructureBoundary | Unknown | Unknown | 0 | 0 | 2024-07-31 09:39:41 | |||||||
StructureBoundary | Electric Substation Boundary | Unknown | 102 | 0 | 2024-07-31 09:42:48 | |||||||
StructureBoundary | Electric Substation Boundary | Distribution Substation | 102 | 82 | Container | Restricted | 2500 | E:Station | 2024-07-31 09:42:48 | |||
StructureJunctionObject | Unknown | Unknown | 0 | 0 | 2024-07-31 09:39:41 | |||||||
StructureJunctionObject | Pole | Unknown | 120 | 0 | 2024-07-31 09:42:51 | |||||||
StructureJunctionObject | Pole | Pole | 120 | 101 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:51 | ||||
StructureJunctionObject | Pole | Ornamental Pole | 120 | 102 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:51 | ||||
StructureJunctionObject | Pole | Tower Leg | 120 | 107 | Structure | Restricted | STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:51 | ||||
StructureLine | Unknown | Unknown | 0 | 0 | 2024-07-31 09:39:41 | |||||||
StructureLine | Wire Aerial Support | Unknown | 103 | 0 | 2024-07-31 09:42:54 | |||||||
StructureLine | Wire Aerial Support | Spanguy | 103 | 123 | Container | Restricted | 10 | False | STR:Cable Support | 2024-07-31 09:42:54 | ||
StructureLine | Wire Aerial Support | Aerial Span | 103 | 125 | Container | Restricted | 150 | False | STR:Cable Pathway;STR:Cable Support;STR:Wire Aerial Support Structure | 2024-07-31 09:42:54 | ||
StructureLine | Wire Aerial Support | Guy Wire | 103 | 128 | Container | Restricted | 10 | False | 2024-07-31 09:42:54 | |||
StructureLine | Wire Trench | Unknown | 104 | 0 | 2024-07-31 09:42:55 | |||||||
StructureLine | Wire Trench | Trench | 104 | 101 | Container | Restricted | 10 | False | STR:Cable Pathway;STR:Cable Support | 2024-07-31 09:42:55 | ||
StructureLine | Electric Low Voltage Conduit | Unknown | 106 | 0 | 2024-07-31 09:42:55 | |||||||
StructureLine | Electric Low Voltage Conduit | Conduit LV | 106 | 118 | Container | Restricted | 15 | False | Any Vertex | STR:Cable Pathway | 2024-07-31 09:42:55 | |
StructureLine | Electric Medium Voltage Conduit | Unknown | 107 | 0 | 2024-07-31 09:42:55 | |||||||
StructureLine | Electric Medium Voltage Conduit | Conduit | 107 | 112 | Container | Restricted | 15 | False | Any Vertex | STR:Cable Pathway | 2024-07-31 09:42:55 | |
StructureEdgeObject | Unknown | Unknown | 0 | 0 | 2024-07-31 09:39:41 | |||||||
ElectricDevice | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricDevice | High Voltage Transformer | Unknown | 11 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | High Voltage Transformer | Power Transformer HV->MV | 11 | 205 | Two Winding | Container | Restricted | 15 | E:Bank;E:Station;E:Transformer - Power;E:Transformer - Power - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:05 | ||
ElectricDevice | Circuit Breaker | Unknown | 26 | 0 | Circuit Breaker Directional | Container | Restricted | 15 | E:Bank;Subnetwork Controller | 2024-07-31 09:43:05 | ||
ElectricDevice | Circuit Breaker | Three Phase Circuit Breaker | 26 | 503 | Circuit Breaker | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Station;E:Switch;E:Switch - Circuit Breaker;E:Switch - Device Features;E:Switch - Load Break;E:Switch - Load Break - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:05 | ||
ElectricDevice | Circuit Breaker | Circuit Source | 26 | 513 | Circuit Breaker Directional | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Circuit Breaker;E:Switch - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;Subnetwork Controller | 2024-07-31 09:43:05 | ||
ElectricDevice | Elbow | Unknown | 28 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features | 2024-07-31 09:43:05 | |||
ElectricDevice | Elbow | Underground Bank | 28 | 5 | Circuit Breaker | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features | 2024-07-31 09:43:05 | ||
ElectricDevice | Fuse | Unknown | 29 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:05 | |||
ElectricDevice | Fuse | Overhead Bank | 29 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:05 | ||
ElectricDevice | Fuse | Underground Bank | 29 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:05 | ||
ElectricDevice | Fuse | Station Bank | 29 | 6 | Circuit Breaker | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Station;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:05 | ||
ElectricDevice | Generation | Unknown | 30 | 0 | Container | Restricted | 15 | E:Bank;E:Generation | 2024-07-31 09:43:05 | |||
ElectricDevice | Generation | Interconnect | 30 | 120 | Circuit Breaker Directional | Container | Restricted | 150 | E:Bank;E:Generation;Subnetwork Controller | 2024-07-31 09:43:05 | ||
ElectricDevice | Line Monitor and Relay | Unknown | 31 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Line Monitor and Relay | Fault Indicator | 31 | 601 | Container | Restricted | 15 | E:Bank;Subnetwork Tap | 2024-07-31 09:43:05 | |||
ElectricDevice | Line Monitor and Relay | Instrument Transformer | 31 | 602 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Line Monitor and Relay | Relay | 31 | 607 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Motor and Pump | Unknown | 32 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Motor and Pump | Single Phase Motor | 32 | 621 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Motor and Pump | Single Phase Pump | 32 | 622 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Motor and Pump | Three Phase Motor | 32 | 623 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Motor and Pump | Three Phase Pump | 32 | 624 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Capacitor | Unknown | 34 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:05 | |||
ElectricDevice | Capacitor | Overhead Bank | 34 | 4 | Container | Restricted | 15 | E:Bank;E:Reactive Power;E:Reactive Power - Device Features | 2024-07-31 09:43:05 | |||
ElectricDevice | Capacitor | Underground Bank | 34 | 5 | Container | Restricted | 15 | E:Bank;E:Reactive Power;E:Reactive Power - Device Features | 2024-07-31 09:43:05 | |||
ElectricDevice | Capacitor | Station Bank | 34 | 6 | Container | Restricted | 15 | E:Bank;E:Reactive Power;E:Reactive Power - Device Features;E:Station | 2024-07-31 09:43:05 | |||
ElectricDevice | Voltage Regulator | Unknown | 35 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Voltage Regulator | Overhead Bank | 35 | 4 | Voltage Regulator | Container | Restricted | 15 | E:Bank;E:Voltage Regulation;E:Voltage Regulation - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Voltage Regulator | Underground Bank | 35 | 5 | Voltage Regulator | Container | Restricted | 15 | E:Bank;E:Voltage Regulation;E:Voltage Regulation - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Voltage Regulator | Station Bank | 35 | 6 | Voltage Regulator | Container | Restricted | 100 | E:Bank;E:Station;E:Voltage Regulation;E:Voltage Regulation - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Primary Service | Unknown | 36 | 0 | Container | Restricted | 15 | E:Bank;E:Load;E:Load - Commercial;E:Load - Customer | 2024-07-31 09:43:06 | |||
ElectricDevice | Primary Service | Primary Meter | 36 | 704 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Recloser | Unknown | 41 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features | 2024-07-31 09:43:06 | |||
ElectricDevice | Recloser | Overhead Bank | 41 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Device Features;E:Switch - Load Break;E:Switch - Load Break - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Recloser | Underground Bank | 41 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Device Features;E:Switch - Load Break;E:Switch - Load Break - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Recloser | Overhead Recloser - Controller | 41 | 734 | Circuit Breaker Directional | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Circuit Breaker;E:Switch - Device Features;E:Switch - Load Break;E:Switch - Load Break - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Recloser | Pad Mounted Recloser - Controller | 41 | 738 | Circuit Breaker Directional | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Protective;E:Protective - Device Features;E:Switch;E:Switch - Circuit Breaker;E:Switch - Device Features;E:Switch - Load Break;E:Switch - Load Break - Device Features;E:Switch - Reclosing;E:Switch - Reclosing - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Sectionalizer | Unknown | 42 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Device Features | 2024-07-31 09:43:06 | |||
ElectricDevice | Sectionalizer | Overhead Bank | 42 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Sectionalizer | Underground Bank | 42 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Switch | Unknown | 37 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | |||
ElectricDevice | Switch | Overhead Bank | 37 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Switch | Underground Bank | 37 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Switch | Station Bank | 37 | 6 | Circuit Breaker | Container | Restricted | 15 | E:Bank;E:Station;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Unknown | 38 | 0 | Two Winding | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Single Phase - MV->LV | 38 | 785 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Three Phase - MV->LV | 38 | 788 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Single Phase - MV->LV | 38 | 789 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Three Phase - MV->LV | 38 | 792 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Submersible Single Phase - MV->LV | 38 | 793 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Submersible;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Submersible Three Phase - MV->LV | 38 | 794 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Submersible;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Open Delta - MV->LV | 38 | 795 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Open Wye - MV->LV | 38 | 796 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Open Delta - MV->LV | 38 | 797 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Open Wye - MV->LV | 38 | 798 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Single Phase Step - MV->MV | 38 | 803 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Three Phase Step - MV->MV | 38 | 804 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Single Phase Step - MV->MV | 38 | 807 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Three Phase Step - MV->MV | 38 | 808 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Submersible Single Phase Step - MV->MV | 38 | 811 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Submersible;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Submersible Three Phase Step - MV->MV | 38 | 812 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Submersible;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Three Phase Step Up - LV->MV | 38 | 816 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Pad Mounted Three Phase Step Up - LV->MV | 38 | 820 | Two Winding | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Transformer - Step;E:Transformer - Step - Device Features;E:Transformer - Voltage;E:Transformer - Voltage - Device Features;Subnetwork Controller | 2024-07-31 09:43:06 | ||
ElectricDevice | Transformer | Overhead Single Phase Step Up - LV->MV | 38 | 822 | Two Winding | E:Bank | 2024-07-31 09:43:06 | |||||
ElectricDevice | Transformer | Pad Mounted Single Phase Step Up - LV->MV | 38 | 824 | Two Winding | E:Bank | 2024-07-31 09:43:06 | |||||
ElectricDevice | Low Voltage Fuse | Unknown | 14 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Fuse | Overhead Bank | 14 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Low Voltage Fuse | Underground Bank | 14 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Low Voltage Fuse | Station Bank | 14 | 6 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Station;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:06 | ||
ElectricDevice | Low Voltage Generation | Unknown | 15 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Generation | Residential Photovoltaic Solar LV | 15 | 284 | Container | Restricted | 15 | E:Bank;E:Generation;E:Generation - Distributed | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Lighting | Unknown | 16 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Lighting | Floodlight LV | 16 | 301 | Container | Restricted | 15 | E:Bank;E:Lighting;E:Lighting - Device Features;E:Load | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Lighting | Streetlight LV | 16 | 302 | Container | Restricted | 15 | E:Bank;E:Lighting;E:Lighting - Device Features;E:Load | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Motor | Unknown | 18 | 0 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Motor | Single Phase Motor LV | 18 | 341 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Motor | Three Phase Motor LV | 18 | 342 | Container | Restricted | 15 | E:Bank | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Service | Unknown | 22 | 0 | Container | Restricted | 15 | E:Bank;E:Load | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Service | Low Voltage Premise LV | 22 | 427 | Container | Restricted | 15 | E:Bank;E:Load - Customer | 2024-07-31 09:43:06 | |||
ElectricDevice | Low Voltage Switch | Unknown | 23 | 0 | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:07 | |||
ElectricDevice | Low Voltage Switch | Overhead Bank | 23 | 4 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:07 | ||
ElectricDevice | Low Voltage Switch | Underground Bank | 23 | 5 | Simple Switch | Container | Restricted | 15 | E:Bank;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:07 | ||
ElectricDevice | Low Voltage Switch | Station Bank | 23 | 6 | Circuit Breaker | Container | Restricted | 15 | E:Bank;E:Station;E:Switch;E:Switch - Device Features;E:Switch - Section Devices;E:Switch - Section Devices - Device Features | 2024-07-31 09:43:07 | ||
ElectricAssembly | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricAssembly | Switch Gear | Unknown | 18 | 0 | E:Bank | 2024-07-31 09:43:25 | ||||||
ElectricAssembly | Switch Gear | Pad Mounted Switch Gear | 18 | 309 | Container | Restricted | 15 | E:Bank;E:Cable - Underground;E:Switch;E:Switch - Assembly Features;E:Switch - Disconnect;E:Switch - Disconnect - Assembly Features | 2024-07-31 09:43:25 | |||
ElectricJunction | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricJunction | Medium Voltage Attachment | Unknown | 7 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Medium Voltage Attachment | Overhead | 7 | 60 | Container | Restricted | 75 | E:Cable - Overhead | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Attachment | Underground | 7 | 61 | Container | Restricted | 10 | E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Attachment | Submersible | 7 | 63 | Container | Restricted | 10 | E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Connection Point | Unknown | 8 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Medium Voltage Connection Point | Busbar Tap | 8 | 80 | Container | Restricted | 15 | 2024-07-31 09:43:29 | ||||
ElectricJunction | Medium Voltage Connection Point | Overhead Tap | 8 | 82 | Container | Restricted | 75 | Attribute Substitution;E:Cable - Overhead;Subnetwork Tap | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Connection Point | Neutral Connection | 8 | 85 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Medium Voltage Connection Point | Underground Tap | 8 | 87 | E:Cable - Underground;Subnetwork Tap | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Medium Voltage Line End | Unknown | 9 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Medium Voltage Line End | Overhead Splice | 9 | 81 | E:Cable - Overhead | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Medium Voltage Line End | Underground Splice | 9 | 84 | E:Cable - Underground | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Medium Voltage Line End | Overhead Line End | 9 | 161 | Container | Restricted | 75 | E:Cable - Overhead;E:Cable - Underground;E:Overhead - Dead End | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Line End | Underground Terminator | 9 | 162 | Container | Restricted | 10 | Attribute Substitution;E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Line End | Overhead Wire Change | 9 | 163 | Container | Restricted | 75 | Attribute Substitution;E:Cable - Overhead | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Line End | Underground Wire Change | 9 | 164 | Container | Restricted | 10 | Attribute Substitution;E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Medium Voltage Line End | Open Point | 9 | 173 | Container | Restricted | 75 | E:Cable - Overhead;E:Cable - Underground;E:Open Point;E:Overhead - Dead End | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Attachment | Unknown | 4 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Low Voltage Attachment | Overhead LV | 4 | 101 | Container | Restricted | 75 | E:Cable - Overhead | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Attachment | Underground LV | 4 | 102 | Container | Restricted | 15 | E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Attachment | Submersible LV | 4 | 107 | E:Cable - Underground | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Low Voltage Connection Point | Unknown | 5 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Low Voltage Connection Point | Busbar Tap LV | 5 | 124 | Container | Restricted | 15 | 2024-07-31 09:43:29 | ||||
ElectricJunction | Low Voltage Connection Point | Overhead Tap LV | 5 | 128 | Container | Restricted | 75 | Attribute Substitution;E:Cable - Overhead;Subnetwork Tap | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Connection Point | Underground Tap LV | 5 | 134 | E:Cable - Underground;Subnetwork Tap | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Low Voltage Line End | Unknown | 6 | 0 | 2024-07-31 09:43:29 | |||||||
ElectricJunction | Low Voltage Line End | Overhead Splice LV | 6 | 120 | E:Cable - Overhead | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Low Voltage Line End | Underground Splice LV | 6 | 126 | E:Cable - Underground | 2024-07-31 09:43:29 | ||||||
ElectricJunction | Low Voltage Line End | Overhead Line End LV | 6 | 141 | Container | Restricted | 15 | E:Cable - Overhead;E:Overhead - Dead End | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Line End | Underground Terminator LV | 6 | 143 | Container | Restricted | 15 | E:Cable - Underground | 2024-07-31 09:43:29 | |||
ElectricJunction | Low Voltage Line End | Overhead Wire Change LV | 6 | 149 | Container | Restricted | 75 | E:Cable - Overhead | 2024-07-31 09:43:29 | |||
ElectricJunctionObject | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Control Unit | 27 | 0 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Capacitor | 27 | 521 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Circuit Breaker | 27 | 522 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Recloser | 27 | 523 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Transfer Switch Controller | 27 | 524 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Medium Voltage Control Unit | Regulator | 27 | 525 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Elbow | Elbow | 28 | 0 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Elbow | AC Underground | 28 | 2 | 2024-07-31 09:43:38 | |||||||
ElectricJunctionObject | Fuse | Fuse | 29 | 0 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:38 | ||||||
ElectricJunctionObject | Fuse | AC Overhead | 29 | 1 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:38 | ||||||
ElectricJunctionObject | Fuse | AC Underground | 29 | 2 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:38 | ||||||
ElectricJunctionObject | Line Monitor and Relay | Line Monitor and Relay | 31 | 0 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Line Monitor and Relay | Fault Indicator | 31 | 601 | Subnetwork Tap | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Line Monitor and Relay | Instrument Transformer | 31 | 602 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Line Monitor and Relay | Relay | 31 | 607 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Motor and Pump | Motor | 32 | 0 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Motor and Pump | Single Phase Motor | 32 | 621 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Motor and Pump | Single Phase Pump | 32 | 622 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Motor and Pump | Three Phase Motor | 32 | 623 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Motor and Pump | Three Phase Pump | 32 | 624 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Capacitor | Capacitor | 34 | 0 | E:Reactive Power;E:Reactive Power - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Capacitor | Overhead | 34 | 1 | E:Reactive Power;E:Reactive Power - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Capacitor | Underground | 34 | 2 | E:Reactive Power;E:Reactive Power - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Voltage Regulator | Regulator | 35 | 0 | E:Voltage Regulation;E:Voltage Regulation - Assembly Features | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Voltage Regulator | Overhead | 35 | 1 | E:Cable - Overhead;E:Voltage Regulation;E:Voltage Regulation - Assembly Features | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Voltage Regulator | Underground | 35 | 2 | E:Voltage Regulation;E:Voltage Regulation - Assembly Features | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Primary Service | Service | 36 | 0 | E:Load;E:Load - Commercial;E:Load - Customer;E:Load - Industrial | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Primary Service | Primary Meter - Industrial Customer MV | 36 | 701 | E:Load;E:Load - Commercial;E:Load - Customer;E:Load - Industrial | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Primary Service | Primary Meter - Utility Customer MV | 36 | 702 | E:Load;E:Load - Commercial;E:Load - Customer;E:Load - Utility | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Primary Service | Primary Meter | 36 | 704 | 2024-07-31 09:43:39 | |||||||
ElectricJunctionObject | Recloser | Recloser | 41 | 0 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Recloser | Overhead | 41 | 1 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Recloser | Underground | 41 | 2 | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Recloser | Overhead - Controller | 41 | 4 | Circuit Breaker Directional | E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects;Subnetwork Controller | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Recloser | Underground - Controller | 41 | 5 | Circuit Breaker Directional | E:Protective;E:Protective - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects;Subnetwork Controller | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Recloser | Overhead Three Phase Recloser - Controller | 41 | 734 | Circuit Breaker Directional | E:Cable - Overhead;E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Circuit Breaker;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects;Subnetwork Controller | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Recloser | Pad Mounted Recloser - Controller | 41 | 738 | Circuit Breaker Directional | E:Cable - Underground;E:Protective;E:Protective - Junction Objects;E:Switch;E:Switch - Circuit Breaker;E:Switch - Junction Objects;E:Switch - Load Break;E:Switch - Load Break - Junction Objects;E:Switch - Reclosing;E:Switch - Reclosing - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects;Subnetwork Controller | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Sectionalizer | Sectionalizer | 42 | 0 | E:Switch - Sectionalizing;E:Switch - Sectionalizing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Sectionalizer | Overhead | 42 | 1 | E:Cable - Overhead;E:Switch - Sectionalizing;E:Switch - Sectionalizing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Sectionalizer | Underground | 42 | 2 | E:Switch - Sectionalizing;E:Switch - Sectionalizing - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Switch | Switch | 37 | 0 | E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Switch | Overhead | 37 | 1 | E:Cable - Overhead;E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Switch | Underground | 37 | 2 | E:Switch;E:Switch - Junction Objects;E:Switch - Section Devices;E:Switch - Section Devices - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Transformer | Transformer | 38 | 0 | Two Winding | E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Single Phase - MV->LV | 38 | 785 | Two Winding | E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Station - MV->LV | 38 | 786 | Two Winding | E:Station;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Three Phase - MV->LV | 38 | 788 | Two Winding | E:Cable - Overhead;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Pad Mounted Single Phase - MV->LV | 38 | 789 | Two Winding | E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Pad Mounted Three Phase - MV->LV | 38 | 792 | Two Winding | E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Submersible Three Phase - MV->LV | 38 | 794 | Two Winding | E:Cable - Submersible;E:Cable - Underground;E:Transformer - Distribution;E:Transformer - Distribution - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Single Phase Step - MV->MV | 38 | 803 | Two Winding | E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Three Phase Step - MV->MV | 38 | 804 | Two Winding | E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Pad Mounted Three Phase Step - MV->MV | 38 | 808 | Two Winding | E:Cable - Underground;E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Station Step - MV->MV | 38 | 813 | Two Winding | E:Station;E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Three Phase Step Up - LV->MV | 38 | 816 | Two Winding | E:Cable - Overhead;E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | |||||
ElectricJunctionObject | Transformer | Overhead Single Phase Step Up - LV->MV | 38 | 822 | E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Transformer | Pad Mounted Single Phase Step Up - LV->MV | 38 | 824 | E:Transformer - Step;E:Transformer - Step - Junction Objects;E:Transformer - Voltage;E:Transformer - Voltage - Junction Objects | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Unknown | 22 | 0 | E:Load;E:Load - Customer | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Single Phase Commercial LV | 22 | 421 | E:Load;E:Load - Commercial;E:Load - Customer | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Single Phase Residential LV | 22 | 422 | E:Load;E:Load - Customer;E:Load - Residential | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Three Phase Commercial LV | 22 | 423 | E:Load;E:Load - Commercial;E:Load - Customer | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Three Phase Residential LV | 22 | 424 | E:Load;E:Load - Customer;E:Load - Residential | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Unmetered Load LV | 22 | 425 | E:Load;E:Load - Customer | 2024-07-31 09:43:39 | ||||||
ElectricJunctionObject | Low Voltage Service | Car Charger LV | 22 | 428 | E:Load;E:Load - Customer;E:Load - EV Charger | 2024-07-31 09:43:39 | ||||||
ElectricLine | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricLine | Medium Voltage Overhead Conductor | Unknown | 9 | 0 | 2024-07-31 09:43:53 | |||||||
ElectricLine | Medium Voltage Overhead Conductor | Overhead Single Phase | 9 | 160 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Overhead Conductor | Overhead Three Phase | 9 | 161 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Overhead Conductor | Overhead Two Phase | 9 | 162 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Overhead Conductor | Overhead Neutral | 9 | 168 | 2024-07-31 09:43:53 | |||||||
ElectricLine | Medium Voltage Underground Conductor | Unknown | 34 | 0 | 2024-07-31 09:43:53 | |||||||
ElectricLine | Medium Voltage Underground Conductor | Underground Single Phase | 34 | 165 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Underground Conductor | Underground Three Phase | 34 | 166 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Underground Conductor | Underground Two Phase | 34 | 167 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Submersible Conductor | Unknown | 35 | 0 | 2024-07-31 09:43:53 | |||||||
ElectricLine | Medium Voltage Submersible Conductor | Submersible Single Phase | 35 | 163 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Submersible;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Submersible Conductor | Submersible Three Phase | 35 | 164 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Submersible;E:Conductor | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Busbar | Unknown | 8 | 0 | 2024-07-31 09:43:53 | |||||||
ElectricLine | Medium Voltage Busbar | Cabinet Single Phase | 8 | 140 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Busbar | Cabinet Three Phase | 8 | 141 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Busbar | Station Three Phase | 8 | 143 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Station | 2024-07-31 09:43:53 | |
ElectricLine | Medium Voltage Connector | Unknown | 10 | 0 | 2024-07-31 09:43:54 | |||||||
ElectricLine | Medium Voltage Connector | Single Phase | 10 | 180 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2024-07-31 09:43:54 | |
ElectricLine | Medium Voltage Connector | Three Phase | 10 | 181 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2024-07-31 09:43:54 | |
ElectricLine | Medium Voltage Connector | Two Phase | 10 | 182 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2024-07-31 09:43:54 | |
ElectricLine | Low Voltage Service | Unknown | 13 | 0 | 2024-07-31 09:43:54 | |||||||
ElectricLine | Low Voltage Service | Overhead Service LV | 13 | 110 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead | 2024-07-31 09:43:54 | |
ElectricLine | Low Voltage Service | Underground Service LV | 13 | 112 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground | 2024-07-31 09:43:54 | |
ElectricLine | Low Voltage Overhead Conductor | Unknown | 6 | 0 | 2024-07-31 09:43:54 | |||||||
ElectricLine | Low Voltage Overhead Conductor | Overhead LV | 6 | 100 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead;E:Conductor | 2024-07-31 09:43:54 | |
ElectricLine | Low Voltage Underground Conductor | Unknown | 37 | 0 | 2024-07-31 09:43:54 | |||||||
ElectricLine | Low Voltage Underground Conductor | Underground LV | 37 | 102 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground;E:Conductor | 2024-07-31 09:43:54 | |
ElectricLine | Low Voltage Submersible Conductor | Unknown | 38 | 0 | 2024-07-31 09:43:54 | |||||||
ElectricLine | Low Voltage Submersible Conductor | Submersible LV | 38 | 101 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Submersible;E:Conductor | 2024-07-31 09:43:54 | |
ElectricEdgeObject | Unknown | Unknown | 0 | 0 | 2024-07-31 09:42:19 | |||||||
ElectricEdgeObject | Aerial Bare | Unknown | 101 | 0 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Aerial Bare | Medium Voltage | 101 | 903 | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Aerial Bare | Low Voltage AC | 101 | 904 | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Aerial Bare | Static Wire | 101 | 906 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Aerial Covered | Unknown | 102 | 0 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Aerial Covered | Medium Voltage | 102 | 903 | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Aerial Covered | Low Voltage AC | 102 | 904 | E:Cable;E:Cable - Low Voltage;E:Cable - Medium and Low Voltage;E:Cable - Overhead | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Busbar | Unknown | 104 | 0 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Busbar | Medium Voltage | 104 | 903 | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Busbar | Low Voltage AC | 104 | 904 | E:Cable;E:Cable - Low Voltage | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Underground | Unknown | 105 | 0 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Underground | Medium Voltage | 105 | 903 | Any Vertex | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage;E:Cable - Underground | 2024-07-31 09:44:05 | |||||
ElectricEdgeObject | Underground | Low Voltage AC | 105 | 904 | Any Vertex | E:Cable;E:Cable - Low Voltage;E:Cable - Underground | 2024-07-31 09:44:05 | |||||
ElectricEdgeObject | Neutral | Unknown | 106 | 0 | 2024-07-31 09:44:05 | |||||||
ElectricEdgeObject | Neutral | Overhead Bare | 106 | 910 | E:Cable;E:Cable - Overhead;E:Ground | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Neutral | Overhead Shielded | 106 | 911 | E:Cable;E:Cable - Overhead;E:Ground | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Neutral | Underground Shielded | 106 | 912 | E:Cable;E:Cable - Underground;E:Ground | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Neutral | Concentric | 106 | 913 | E:Cable;E:Ground | 2024-07-31 09:44:05 | ||||||
ElectricEdgeObject | Submarine | Unknown | 108 | 0 | 2024-07-31 09:44:06 | |||||||
ElectricEdgeObject | Submarine | Medium Voltage | 108 | 903 | E:Cable;E:Cable - High and Medium Voltage;E:Cable - Medium Voltage;E:Cable - Medium and Low Voltage | 2024-07-31 09:44:06 | ||||||
ElectricEdgeObject | Submarine | Low Voltage AC | 108 | 904 | E:Cable;E:Cable - Low Voltage | 2024-07-31 09:44:06 | ||||||
ElectricEdgeObject | Connector | Unknown | 109 | 0 | 2024-07-31 09:44:06 | |||||||
ElectricEdgeObject | Connector | Medium Voltage | 109 | 903 | 2024-07-31 09:44:06 | |||||||
ElectricEdgeObject | Connector | Low Voltage AC | 109 | 904 | 2024-07-31 09:44:06 |
Category Name | Creation Time |
---|---|
Subnetwork Controller | 2024-07-31 09:39:40 |
Subnetwork Tap | 2024-07-31 09:39:40 |
Attribute Substitution | 2024-07-31 09:39:40 |
E:Bank | 2024-07-31 09:44:17 |
E:Cable | 2024-07-31 09:44:17 |
E:Cable - High and Medium Voltage | 2024-07-31 09:44:17 |
E:Cable - Low Voltage | 2024-07-31 09:44:17 |
E:Cable - Medium Voltage | 2024-07-31 09:44:17 |
E:Cable - Medium and Low Voltage | 2024-07-31 09:44:17 |
E:Cable - Overhead | 2024-07-31 09:44:17 |
E:Cable - Submersible | 2024-07-31 09:44:17 |
E:Cable - Underground | 2024-07-31 09:44:17 |
E:Conductor | 2024-07-31 09:44:17 |
E:Generation | 2024-07-31 09:44:17 |
E:Generation - Distributed | 2024-07-31 09:44:17 |
E:Ground | 2024-07-31 09:44:17 |
E:Lighting | 2024-07-31 09:44:17 |
E:Lighting - Device Features | 2024-07-31 09:44:17 |
E:Load | 2024-07-31 09:44:17 |
E:Load - Commercial | 2024-07-31 09:44:17 |
E:Load - Customer | 2024-07-31 09:44:17 |
E:Load - EV Charger | 2024-07-31 09:44:17 |
E:Load - Industrial | 2024-07-31 09:44:17 |
E:Load - Residential | 2024-07-31 09:44:17 |
E:Load - Utility | 2024-07-31 09:44:17 |
E:Open Point | 2024-07-31 09:44:17 |
E:Overhead - Dead End | 2024-07-31 09:44:17 |
E:Protective | 2024-07-31 09:44:17 |
E:Protective - Device Features | 2024-07-31 09:44:17 |
E:Protective - Junction Objects | 2024-07-31 09:44:17 |
E:Reactive Power | 2024-07-31 09:44:17 |
E:Reactive Power - Device Features | 2024-07-31 09:44:17 |
E:Reactive Power - Junction Objects | 2024-07-31 09:44:17 |
E:Station | 2024-07-31 09:44:17 |
E:Switch | 2024-07-31 09:44:17 |
E:Switch - Assembly Features | 2024-07-31 09:44:17 |
E:Switch - Circuit Breaker | 2024-07-31 09:44:17 |
E:Switch - Device Features | 2024-07-31 09:44:17 |
E:Switch - Disconnect | 2024-07-31 09:44:17 |
E:Switch - Disconnect - Assembly Features | 2024-07-31 09:44:17 |
E:Switch - Junction Objects | 2024-07-31 09:44:17 |
E:Switch - Load Break | 2024-07-31 09:44:17 |
E:Switch - Load Break - Device Features | 2024-07-31 09:44:17 |
E:Switch - Load Break - Junction Objects | 2024-07-31 09:44:17 |
E:Switch - Reclosing | 2024-07-31 09:44:17 |
E:Switch - Reclosing - Device Features | 2024-07-31 09:44:17 |
E:Switch - Reclosing - Junction Objects | 2024-07-31 09:44:17 |
E:Switch - Section Devices | 2024-07-31 09:44:17 |
E:Switch - Section Devices - Device Features | 2024-07-31 09:44:17 |
E:Switch - Section Devices - Junction Objects | 2024-07-31 09:44:17 |
E:Switch - Sectionalizing | 2024-07-31 09:44:17 |
E:Switch - Sectionalizing - Device Features | 2024-07-31 09:44:17 |
E:Switch - Sectionalizing - Junction Objects | 2024-07-31 09:44:17 |
E:Transformer - Distribution | 2024-07-31 09:44:17 |
E:Transformer - Distribution - Device Features | 2024-07-31 09:44:17 |
E:Transformer - Distribution - Junction Objects | 2024-07-31 09:44:17 |
E:Transformer - Power | 2024-07-31 09:44:17 |
E:Transformer - Power - Device Features | 2024-07-31 09:44:17 |
E:Transformer - Step | 2024-07-31 09:44:17 |
E:Transformer - Step - Device Features | 2024-07-31 09:44:17 |
E:Transformer - Step - Junction Objects | 2024-07-31 09:44:17 |
E:Transformer - Voltage | 2024-07-31 09:44:17 |
E:Transformer - Voltage - Device Features | 2024-07-31 09:44:17 |
E:Transformer - Voltage - Junction Objects | 2024-07-31 09:44:17 |
E:Voltage Regulation | 2024-07-31 09:44:17 |
E:Voltage Regulation - Assembly Features | 2024-07-31 09:44:17 |
E:Voltage Regulation - Device Features | 2024-07-31 09:44:17 |
STR:Cable Pathway | 2024-07-31 09:44:17 |
STR:Cable Support | 2024-07-31 09:44:17 |
STR:Duct Bank | 2024-07-31 09:44:17 |
STR:Duct Trace | 2024-07-31 09:44:17 |
STR:Overhead Spans | 2024-07-31 09:44:17 |
STR:Wire Aerial Support Structure | 2024-07-31 09:44:17 |
Configuration Name | Configuration ID | Traversability Model | Default | Creation Time |
---|---|---|---|---|
Single terminal | 0 | Bidirectional | All | 2024-07-31 09:39:40 |
Dual Terminal | 2 | Bidirectional | All | 2024-07-31 09:44:17 |
T-Blade Switch | 3 | Bidirectional | All | 2024-07-31 09:44:17 |
Two Winding | 4 | Directional | All | 2024-07-31 09:44:17 |
V-Blade Switch | 5 | Bidirectional | All | 2024-07-31 09:44:17 |
Inverter | 6 | Bidirectional | All | 2024-07-31 09:44:17 |
Rectifier | 7 | Bidirectional | All | 2024-07-31 09:44:17 |
Circuit Breaker | 8 | Bidirectional | All | 2024-07-31 09:44:17 |
Four Terminal Bypass Switch | 9 | Bidirectional | Closed | 2024-07-31 09:44:17 |
Voltage Regulator | 10 | Bidirectional | All | 2024-07-31 09:44:17 |
High Voltage Disconnect Switch | 11 | Bidirectional | All | 2024-07-31 09:44:17 |
High Voltage Inline Switch | 12 | Bidirectional | All | 2024-07-31 09:44:17 |
Relay | 13 | Bidirectional | All | 2024-07-31 09:44:17 |
Simple Switch | 14 | Bidirectional | All | 2024-07-31 09:44:17 |
SCADA Devices | 15 | Bidirectional | None | 2024-07-31 09:44:17 |
Three Winding | 16 | Directional | Primary to Both | 2024-07-31 09:44:17 |
E:SourceToLoad | 17 | Bidirectional | All | 2024-07-31 09:44:17 |
Circuit Breaker Directional | 18 | Directional | All | 2024-07-31 09:44:17 |
Two Winding Bidirectional | 19 | Bidirectional | All | 2024-07-31 09:44:17 |
Ground Switch | 20 | Bidirectional | All | 2024-07-31 09:44:17 |
Transformer Winding | 21 | Directional | All | 2024-07-31 09:44:17 |
Configuration Name | Terminal Name | Terminal ID | Upstream |
---|---|---|---|
Single terminal | Single Terminal | 1 | |
Dual Terminal | DT:Source | 2 | |
Dual Terminal | DT:Load | 3 | |
T-Blade Switch | T:Terminal A | 4 | |
T-Blade Switch | T:Terminal B | 5 | |
T-Blade Switch | T:Terminal C | 6 | |
Two Winding | 2wXFR:Primary | 7 | True |
Two Winding | 2wXFR:Secondary | 8 | False |
V-Blade Switch | V:Terminal A | 9 | |
V-Blade Switch | V:Terminal B | 10 | |
V-Blade Switch | V:Terminal C | 11 | |
Inverter | INV:DC Input | 12 | |
Inverter | INV:AC Output | 13 | |
Rectifier | RT:AC Input | 14 | |
Rectifier | RT:DC Output | 15 | |
Circuit Breaker | CB:Line Side | 16 | |
Circuit Breaker | CB:Bus Side | 17 | |
Four Terminal Bypass Switch | Bypass:Regulator Source | 18 | |
Four Terminal Bypass Switch | Bypass:Regulator Load | 19 | |
Four Terminal Bypass Switch | Bypass:Regulator In Bushing | 20 | |
Four Terminal Bypass Switch | Bypass:Regulator Out Bushing | 21 | |
Voltage Regulator | VR:In Bushing | 22 | |
Voltage Regulator | VR:Out Bushing | 23 | |
High Voltage Disconnect Switch | HVDS:Bus Side | 24 | |
High Voltage Disconnect Switch | HVDS:Line Side | 25 | |
High Voltage Inline Switch | HVIS:Terminal A | 26 | |
High Voltage Inline Switch | HVIS:Terminal B | 27 | |
Relay | RT:Measured Power | 28 | |
Relay | RT:Communications | 29 | |
Relay | RT:Aux Power | 30 | |
Simple Switch | SS:S1 | 31 | |
Simple Switch | SS:S2 | 32 | |
SCADA Devices | Power | 33 | |
SCADA Devices | Monitor | 34 | |
SCADA Devices | Communications | 35 | |
Three Winding | 3wXFR:Primary | 36 | True |
Three Winding | 3wXFR:Secondary | 37 | False |
Three Winding | 3wXFR:Tertiary | 38 | False |
E:SourceToLoad | Line Side | 39 | |
E:SourceToLoad | Load Side | 40 | |
Circuit Breaker Directional | CBD:Line Side | 41 | False |
Circuit Breaker Directional | CBD:Bus Side | 42 | True |
Two Winding Bidirectional | 2wXFRBD:Primary | 43 | |
Two Winding Bidirectional | 2wXFRBD:Secondary | 44 | |
Ground Switch | GS:Line Side | 45 | |
Ground Switch | GS:Ground Side | 46 | |
Transformer Winding | TW:Core | 47 | True |
Transformer Winding | TW:Bushing | 48 | False |
Configuration Name | Path Name | Path ID | Path Description |
---|---|---|---|
T-Blade Switch | All | 1 | All |
T-Blade Switch | B-C | 2 | T:Terminal B-T:Terminal C |
T-Blade Switch | A-B | 3 | T:Terminal A-T:Terminal B |
T-Blade Switch | A-C | 4 | T:Terminal A-T:Terminal C |
T-Blade Switch | None | 0 | None |
V-Blade Switch | All | 1 | All |
V-Blade Switch | B-C | 5 | V:Terminal B-V:Terminal C |
V-Blade Switch | A-C | 6 | V:Terminal A-V:Terminal C |
V-Blade Switch | Open | 0 | None |
V-Blade Switch | None | 0 | None |
Four Terminal Bypass Switch | Open | 7 | Bypass:Regulator Source-Bypass:Regulator Load |
Four Terminal Bypass Switch | None | 0 | None |
Four Terminal Bypass Switch | Closed | 8 | Bypass:Regulator Source-Bypass:Regulator In Bushing,Bypass:Regulator Out Bushing-Bypass:Regulator Load |
Relay | All | 1 | All |
Relay | None | 0 | None |
SCADA Devices | None | 0 | None |
SCADA Devices | All | 1 | All |
Three Winding | Primary to Both | 9 | 3wXFR:Primary-3wXFR:Secondary,3wXFR:Primary-3wXFR:Tertiary |
Three Winding | Primary to Secondary | 10 | 3wXFR:Primary-3wXFR:Secondary |
Three Winding | Primary to Tertiary | 11 | 3wXFR:Primary-3wXFR:Tertiary |
Three Winding | None | 0 | None |
Name | ID | Usage Type | Data Type | Field Type | Inline | Domain Name | Nullable | Apportionable | Substitution Attribute | Bit Position | Bit Size | Junction ID | Edge ID | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Source ID | 1 | Source ID | Integer | Short Integer | True | False | False | 0 | 7 | 1 | 2 | 2024-07-31 09:39:40 | ||
Terminal ID | 2 | Terminal ID | Integer | Short Integer | False | False | False | 7 | 0 | 3 | 4 | 2024-07-31 09:39:40 | ||
Asset group | 3 | Asset Group | Integer | Short Integer | True | False | False | 7 | 10 | 5 | 6 | 2024-07-31 09:39:40 | ||
Asset type | 4 | Asset Type | Integer | Short Integer | True | False | False | 17 | 10 | 7 | 8 | 2024-07-31 09:39:40 | ||
Is subnetwork controller | 5 | Is Subnetwork Controller | Integer | Short Integer | True | False | False | 27 | 1 | 9 | 10 | 2024-07-31 09:39:40 | ||
Tier name | 6 | Tier Name | Integer | Short Integer | True | False | False | 28 | 6 | 11 | 12 | 2024-07-31 09:39:40 | ||
Shape length | 7 | Shape Length | Double | Double | False | False | True | 34 | 0 | 13 | 14 | 2024-07-31 09:39:40 | ||
Position from | 8 | Position From | Double | Double | False | False | False | 34 | 0 | 15 | 16 | 2024-07-31 09:39:40 | ||
Position to | 9 | Position To | Double | Double | False | False | False | 34 | 0 | 17 | 18 | 2024-07-31 09:39:40 | ||
Flow direction | 10 | Flow Direction | Integer | Short Integer | True | False | False | 34 | 2 | 19 | 20 | 2024-07-31 09:39:40 | ||
Construction Status | 11 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 21 | 22 | 2024-07-31 09:44:17 | ||
Date In Service | 12 | Unknown | Double | Date | False | True | False | 0 | 0 | 23 | 24 | 2024-07-31 09:44:17 | ||
Date Installed | 13 | Unknown | Double | Date | False | True | False | 0 | 0 | 25 | 26 | 2024-07-31 09:44:17 | ||
Date Retired | 14 | Unknown | Double | Date | False | True | False | 0 | 0 | 27 | 28 | 2024-07-31 09:44:17 | ||
E:Field Operation | 15 | Unknown | Integer | Short Integer | True | Electric_Device_Operation | True | False | 36 | 2 | 29 | 30 | 2024-07-31 09:44:17 | |
E:Nominal Operating Voltage | 16 | Unknown | Integer | Long Integer | False | True | False | 0 | 0 | 31 | 32 | 2024-07-31 09:44:17 | ||
E:Nominal Voltage LG | 17 | Unknown | Integer | Long Integer | False | True | False | 0 | 0 | 33 | 34 | 2024-07-31 09:44:17 | ||
E:Operating Mechanism | 18 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 35 | 36 | 2024-07-31 09:44:17 | ||
E:Operating Status Normal | 19 | Unknown | Integer | Short Integer | True | Electric_Operating_Status | True | False | 39 | 2 | 37 | 38 | 2024-07-31 09:44:17 | |
E:Phases Constructed | 20 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 39 | 40 | 2024-07-31 09:44:17 | ||
E:Phases Normal | 21 | Unknown | Integer | Short Integer | False | False | False | 0 | 0 | 41 | 42 | 2024-07-31 09:44:17 | ||
E:Phases Propagated | 22 | Unknown | Integer | Short Integer | True | Electric_Phase_Attribution_All | True | False | 42 | 3 | 43 | 44 | 2024-07-31 09:44:17 | |
E:Power | 23 | Unknown | Integer | Long Integer | False | True | False | 0 | 0 | 45 | 46 | 2024-07-31 09:44:17 | ||
E:Riser | 24 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 47 | 48 | 2024-07-31 09:44:17 | ||
E:Section Head | 25 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 49 | 50 | 2024-07-31 09:44:17 | ||
Is Critical | 26 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 51 | 52 | 2024-07-31 09:44:17 | ||
Is Valid Loop | 27 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 53 | 54 | 2024-07-31 09:44:17 | ||
Lifecycle Status | 28 | Unknown | Integer | Short Integer | True | Lifecycle_Status | False | False | 46 | 3 | 55 | 56 | 2024-07-31 09:44:17 | |
Measured Length | 29 | Unknown | Double | Double | False | True | True | 0 | 0 | 57 | 58 | 2024-07-31 09:44:17 | ||
Minimum Bend Radius Metric | 30 | Unknown | Double | Double | False | True | False | 0 | 0 | 59 | 60 | 2024-07-31 09:44:17 |
Key | Value |
---|---|
Name | main.StructureJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 34 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | StructureJunction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {9FF2808D-7EAB-4222-9CDA-DDAC10C76E16} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Structure Junction feature class represents features which are tracked in a utility's asset inventory system. A structure junction can be either a structural feature that a device is attached to or a container of devices. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
materialcode | Material Code and Description | Short Integer | True | Wire_Structure_Junction_Combined_Material | 0 | 0 | 2 | True | False | The code used for describing the material used in this structure | ||
height | height: Height, Platform Height, Pole Height | Short Integer | True | Wire_Pole_Height_Combined | 0 | 0 | 2 | True | False | The heighth of this structure | ||
treatment | treatment: Pole Treatment Type, Treatment Type | Short Integer | True | 0 | 0 | 2 | True | False | The method or material used to treat the structure | |||
depth | Depth | Double | True | 0 | 0 | 8 | True | False | The burried depth of the structure | |||
equipmenttypeorclass | equipmenttypeorclass: Cabinet Type, Class, Manhole Type, Pole Class, Type, Vault Type | Short Integer | True | Wire_Structure_Junction_Pole_Class_Combined | 0 | 0 | 2 | True | False | An extra attribute to futher define equipment type without adding an additional asset type | ||
indicatortypefield | Type of Marker | Short Integer | True | 0 | 0 | 2 | True | False | Describes the type of marker indicator, such as lighted | |||
grounded | Structure Grounded | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | Indicator that this structure is properly grounded | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
retireddate | Retired Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was retired or taken out of service | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
labeltext | Labeling String | String | True | 0 | 0 | 256 | True | False | A free form field that can be used in labeling | |||
notes | General Notes | String | True | 0 | 0 | 2000 | True | False | A free form notes field | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | The angle the symbol should be rotated by | ||
diameter | Diameter | Double | True | 0 | 0 | 8 | True | False | The diameter of the structure | |||
designtype | designtype: Design Type, Ground Type | Short Integer | True | 0 | 0 | 2 | True | False | Used to provide engineering information specific to the asset group | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_34_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_38 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Wire Cabinet | 101 | The Wire Cabinet is intended for use for containing non-switch and non-transformer pad mounted equipment such as capacitor controllers. |
Wire Structure Guy | 102 | An Wire Guy is a tensioned cable with anchor designed to add stability to a pole. |
Wire Handhole | 103 | The Wire Handhole represents an access box frequently used to access low voltage or service conductors. |
Wire Junction Box | 104 | The Wire Junction box is typically a water tight surface structure used for low voltage connections. |
Wire Vault | 110 | Wire Vaults are typically concrete rooms that will contain surface mounted equipment, like transformers. |
Wire Pedestal | 107 | Wire Pedestal are typically short vertical structures typically used to mount a customer meter devices on. |
Electric High Voltage Pole | 120 | Electric High Voltage Poles are vertical support structures used to support High Voltage or Transmission lines. Medium Voltage and Low Voltage equipment can be associated this feature type. |
Electric Medium Voltage Pole | 121 | Electric Medium Voltage Poles are vertical support structures used to support Medium Voltage or Distribution lines. Medium Voltage and Low Voltage equipment can be associated this feature type, but High Voltage equipment cannot be associated with this structure type. |
Electric Low Voltage Pole | 122 | Electric Low Voltage Poles are vertical support structures used to support Low lines. Low Voltage equipment can be associated this feature type, but High Voltage and Medium Voltage equipment cannot be associated with this structure type. |
Wire Support Pole | 123 | Wire Support Poles are Vertical support structures typically used to "Brace" an other pole when a Anchor Guy cannot be used to support it. |
Marker | 124 | Markers are types of structures used to warn of the location of power lines. These are frequently used for high voltage power lines or where medium voltage or higher voltage lines cross water bodies where boat booms could potentially come in contact with power lines. |
Key | Value |
---|---|
Name | main.ElectricSubnetLine |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 269 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ElectricSubnetLine |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | TIERNAME |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {A172DE1B-D3B5-47AF-A773-0A28F9F3F141} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The system maintained set of subnetworks. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
SUBNETWORKNAME | Subnetwork Name | String | False | Unknown | 0 | 0 | 64 | False | True | |||
ISDIRTY | Is Dirty | Short Integer | False | Network_6_IsDirty | 1 | 0 | 0 | 2 | False | True | ||
TIERNAME | Tier Name | Short Integer | Subtype | False | 0 | 0 | 0 | 2 | False | True | ||
SUBNETWORKCONTROLLERNAMES | Subnetwork Controller Names | String | False | Unknown | 0 | 0 | 1073741822 | False | True | |||
LASTUPDATESUBNETWORK | Last Update Subnetwork | Date | True | 0 | 0 | 8 | False | True | ||||
LASTACKEXPORTSUBNETWORK | Last Ack Export Subnetwork | Date | True | 0 | 0 | 8 | False | True | ||||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
UUID_47 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricSubnetLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricSubnetLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Electric Distribution | 1 | Subnetwork aggregated lines for the Generation Tier |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | ISDIRTY | 1 | Network_6_IsDirty | |
Unknown | 0 | SUBNETWORKCONTROLLERNAMES | Unknown | ||
Electric Distribution | 1 | SUBNETWORKNAME | Unknown | ||
Electric Distribution | 1 | ISDIRTY | 1 | Network_6_IsDirty | |
Electric Distribution | 1 | SUBNETWORKCONTROLLERNAMES | Unknown |
Key | Value |
---|---|
Name | main.ElectricDevice |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 264 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ElectricDevice |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {CF2B1A2A-7589-4C82-9BE2-201C032F4E03} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Device feature class represents features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISSUBNETWORKCONTROLLER | Is Subnetwork Controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | An indicator that an object is a subnetwork controller in the utility network | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | An indicator that an object is connected to a subnetwork in the utility network and can be used to identify isolated objects | |
SUBNETWORKCONTROLLERNAME | Subnetwork Controller Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name of the subnetwork controller in the tier | |
TIERNAME | Tier Name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | The name of the tier to which the subnetwork belongs | |
TIERRANK | Tier Rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | The rank number assigned to the tier to which the subnetwork belongs | ||
TERMINALCONFIGURATION | Terminal Path | String | False | Default | 0 | 0 | 128 | True | True | terminal configuration used which defines the terminals and the paths between them | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | Globally unique Identifier across geodatabases | ||
SUBNETWORKNAME | Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature participates in | |
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature either has an attachment to or contains elements from | |
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature is contained in | |
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
normaloperatingstatus | Normal Status | Short Integer | True | Electric_Operating_Status | 0 | 0 | 2 | True | False | The normal state for a swtichable device | ||
phasesnormal | Phases Normal | Short Integer | False | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | |
phasechange | Phase Change | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The new phases to be used in propagation | ||
phasesenergized | Phases Energized | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from propagation | |
numphasesconstructed | Num Phases Built | Short Integer | True | Electric_Medium_Low_Voltage_Number_Of_Phases | 3 | 0 | 0 | 2 | True | False | Number of phases built which can be used to compare to the phasesengergized field to detect connectivity issues | |
designtype | designtype: Closing Type, Design Type, Fuel Type, Fuse Type, Ground Type, Light Type, Motor Type, Series or Shunt | Short Integer | True | Electric_Combined_Designtypes | 0 | 0 | 2 | True | False | Used to provide engineering information specific to the asset group | ||
grounding | Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye | ||
nominalvoltagelinetoline | nominalvoltage: Nominal Voltage (L-L), Primary Nominal Voltage (L-L), Rated AC Voltage | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
nominalvoltagelinetoground | nominalvoltagelg: Nominal Voltage (L-G), Primary Nominal Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named line to neutral or ground measured in Voltage | ||
secondaryvoltagelinetoline | secondaryvoltagelinetoline: Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L), Voltage (L-L) | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named Secondary line to line voltage measured in Volts | ||
secondaryvoltagelinetoground | secondaryvoltagelinetoground: Secondary Voltage (L-G), Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named Secondary line to neutral or ground measured in Voltage | ||
secondarygrounding | secondarygrounding: Grounding, Secondary Winding Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye on the Secondary Winding | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | The angle the symbol should be rotated by | ||
ratedpower | ratedpower: AC Output Power, Light Watts, Max Interrupting Current, Rated Current, Rated Load (Watts), Rated Power, Rated Power (Watts), Rated Power kVA, Rated kVA, Rated kVAR | Long Integer | True | 0 | 0 | 4 | True | False | The Rated Power for the equipment | |||
powerfactor | Power Factor | Double | True | 0 | 0 | 8 | True | False | The ratio of working power, measured in kilowatts (kW), to apparent power, measured in kilovolt amperes (kVA) | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
fieldoperation | Equipment Field Operation | Short Integer | True | Electric_Device_Operation | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | ||
operatingmechanism | Equipment Field Operating Mechanism | Short Integer | True | Electric_Device_OperatingMechanism | 0 | 0 | 2 | True | False | Used to indicate how the equipment can be operated, example hook stick | ||
iscritical | Is Critical | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment or customer is of a critical nature | ||
isriser | Is Riser | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment also acts as a riser or dip |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_264_SUBNETWO | False | True | SUBNETWORKCONTROLLERNAME |
GDB_264_SUBNETWO_1 | False | True | SUBNETWORKNAME |
GDB_264_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_264_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_43 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricDevice_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
High Voltage Transformer | 11 | Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase. |
Circuit Breaker | 26 | A type of switch used as a network controller or start of a circuit or feeder. |
Elbow | 28 | A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch. |
Fuse | 29 | A device used to protect the system from over current conditions, such as faults. |
Generation | 30 | A generation facility, such as a group or a single turbine, used in the generation of medium volumes of watts, such as solar farms . |
Line Monitor and Relay | 31 | Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions. |
Motor and Pump | 32 | Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events. |
Capacitor | 34 | A device used in the correction of the power factor of AC energy. |
Voltage Regulator | 35 | Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device. |
Primary Service | 36 | A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter. |
Recloser | 41 | A self reclosing switch |
Sectionalizer | 42 | A sectionlizing switch |
Switch | 37 | A switch used to control the flow of energy. |
Transformer | 38 | Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase. |
Low Voltage Fuse | 14 | A device used to protect the system from over current conditions, such as faults. |
Low Voltage Generation | 15 | Generation devices typically located at a customer residence, like rooftop solar. |
Low Voltage Lighting | 16 | A device used for lighting such as a streetlight or flood light. |
Low Voltage Motor | 18 | A motor, typically used in industrial operations. |
Low Voltage Service | 22 | A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location. |
Low Voltage Switch | 23 | A switch used to control the flow of energy. |
Key | Value |
---|---|
Name | main.ElectricJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 268 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ElectricJunction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {D66C7399-033C-4782-A74A-5A5BABCA9125} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Junction class represents locations where lines connect to lines or lines connect to devices. A key use for junction features is to allow devices or lines to connect to another line at an intermediate vertex. You can think of a junction as 'glue point' at key places to connect all the features of a utility network. Junctions can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
phasesnormal | Phases Normal | Short Integer | False | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | |
phasechange | Phase Change | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The new phases to be used in propagation | ||
phasesenergized | Phases Energized | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from propagation | |
numphasesconstructed | Num Phases Built | Short Integer | True | Electric_Medium_Low_Voltage_Number_Of_Phases | 0 | 0 | 2 | True | False | Number of phases built which can be used to compare to the phasesengergized field to detect connectivity issues | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
symbolrotation | Symbol Rotation | Short Integer | True | Symbol_Rotation | 0 | 0 | 2 | True | False | The angle the symbol should be rotated by | ||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
isriser | Is Riser | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment also acts as a riser or dip |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_268_SUBNETWO | False | True | SUBNETWORKNAME |
GDB_268_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_268_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_46 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Medium Voltage Attachment | 7 | Points on Medium voltage lines where structures would attach. |
Medium Voltage Connection Point | 8 | Points where electric cables connect, but no device exists, like a Tap. |
Medium Voltage Line End | 9 | Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End". |
Low Voltage Attachment | 4 | Points on Low voltage lines where structures would attach. |
Low Voltage Connection Point | 5 | Points where electric cables connect, but no device exists, like a Tap. |
Low Voltage Line End | 6 | Ends of cables, both overhead and underground. In overhead, these will often the location of a "Dead End". |
Key | Value |
---|---|
Name | main.ElectricLine |
Dataset Type | FeatureClass |
Feature Dataset | main.Essentials_UtilityNetwork |
Dataset ID | 266 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ElectricLine |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 1048349.1128980744 |
Y-Min | 1858503.6181093522 |
X-Max | 1061329.2428432773 |
Y-Max | 1875220.6228314422 |
Catalog ID | {D96BCF2C-6988-4F81-AB0C-DAACED3CEC5E} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Extension Class ID | |
Details | The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
FROMDEVICETERMINAL | From Device Terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | ||
TODEVICETERMINAL | To Device Terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
phasesnormal | Phases Normal | Short Integer | False | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | |
phasechange | Phase Change | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The new phases to be used in propagation | ||
phasesenergized | Phases Energized | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from propagation | |
numphasesconstructed | Num Phases Built | Short Integer | True | 0 | 0 | 2 | True | False | Number of phases built which can be used to compare to the phasesengergized field to detect connectivity issues | |||
nominalvoltagelinetoline | Nominal Voltage (L-L) | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
nominalvoltagelinetoground | Nominal Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named line to neutral or ground measured in Voltage | ||
grounding | Grounding | Short Integer | True | Electric_Ground_Configuration | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye | ||
commonconductortype | Material Label | Short Integer | True | 0 | 0 | 2 | True | False | The conductor material type used in this section by most conductors in the section | |||
neutraltype | Neutral Material | Short Integer | True | Electric_Neutral_Material | 0 | 0 | 2 | True | False | The type of neutral material used | ||
sharedneutral | Shared Neutral | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | An indicator that the neutral is shared with multiple subnetworks | ||
tiername | Tier Name | Short Integer | True | 0 | 0 | 2 | True | False | ||||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
ohm | Ohm Per Length | Double | True | 0 | 0 | 8 | True | False | The electrical resistance measured in ohms of the cable | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
normaloperatingstatus | Current Operating Status | Short Integer | True | Electric_Operating_Status | 0 | 0 | 2 | True | False | The normal state for a swtichable device | ||
conductorsperphase | Conductors Per Phase | Short Integer | True | 0 | 0 | 2 | True | False | The number of conductors per phase, configured in parallel | |||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
conductormaterial | Conductor Material | Short Integer | True | Electric_Connector_Material | 0 | 0 | 2 | True | False | The material description of the conductor | ||
conductorsize | Conductor Diamter | Double | True | Electric_Wire_Diameter_in | 0 | 0 | 8 | True | False | The wire size of the conductor | ||
st_length(SHAPE) | SHAPE_Length | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_266_SUBNETWO | False | True | SUBNETWORKNAME |
GDB_266_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_266_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_44 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Medium Voltage Overhead Conductor | 9 | Overhead Medium Voltage lines represent Distribution or Overhead Sub transmission cables, can be polyphase lines that represent multiple lines per phase. |
Medium Voltage Underground Conductor | 34 | Underground Medium Voltage lines represent Distribution or Overhead Sub transmission cables, can be polyphase lines that represent multiple lines per phase. |
Medium Voltage Submersible Conductor | 35 | Submarine Medium Voltage lines represent Distribution or Overhead Sub transmission cables, can be polyphase lines that represent multiple lines per phase. |
Medium Voltage Busbar | 8 | Busbar is solid conductor used in cabinets or substations on the medium voltage side of equipment. |
Medium Voltage Connector | 10 | A line used to connect equipment, but would not be considered trackable cable. |
Low Voltage Service | 13 | A Low Voltage line to provide electric service |
Low Voltage Overhead Conductor | 6 | Overhead Low Voltage lines represent secondary or low voltage cables, can be polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
Low Voltage Underground Conductor | 37 | Underground Low Voltage lines represent secondary or low voltage cables, can be polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
Low Voltage Submersible Conductor | 38 | Submersible Low Voltage lines represent secondary or low voltage cables, can be polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
Key | Value |
---|---|
Name | main.StructureJunctionObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 39 |
Minimum Client Version | 13.2 |
Alias | Structure Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {3A29666E-6D72-465C-9844-48FEEE0D5DCB} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The Structure Junction object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial point feature for locatability. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
retireddate | Retired Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was retired or taken out of service | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
materialcode | materialcode: Material, Material Code and Description | Short Integer | True | 0 | 0 | 2 | True | False | The code used for describing the material used in this structure | |||
height | Height | Double | True | 0 | 0 | 8 | True | False | The heighth of this structure | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
equipmenttypeorclass | equipmenttypeorclass | Short Integer | True | Wire_Structure_Junction_Pole_Class_Combined | 0 | 0 | 2 | True | False | An extra attribute to futher define equipment type without adding an additional asset type |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_39_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_41 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureJunction class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Pole | 120 | A vertical support structure used to support overhead cables |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
Pole | 120 | ASSETTYPE | 0 | Asset_Type_Structure_JunctionObject_Pole | |
Pole | 120 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Pole | 120 | SUBNETWORKNAME | Unknown | ||
Pole | 120 | constructionstatus | 6 | Construction_Status | |
Pole | 120 | equipmenttypeorclass | Wire_Structure_Junction_Pole_Class_Combined | ||
Pole | 120 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.StructureEdgeObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 40 |
Minimum Client Version | 13.2 |
Alias | Structure Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {8EA28CD6-6207-4196-B705-7E303776A611} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The Structure Edge object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial linear feature for locatability. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_40_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_42 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the Structure Edge Object class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection | |
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.ElectricJunctionObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 270 |
Minimum Client Version | 13.2 |
Alias | Electric Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {17EEF6C7-C829-485B-BEC9-88A10370EE8D} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The Junction Object class represents non-spatial equipment and objects. The wire data is also modeled as junction objects to reduce the system junctions when these objects are only contained. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISSUBNETWORKCONTROLLER | Is Subnetwork Controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | An indicator that an object is a subnetwork controller in the utility network | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | An indicator that an object is connected to a subnetwork in the utility network and can be used to identify isolated objects | |
SUBNETWORKCONTROLLERNAME | Subnetwork Controller Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name of the subnetwork controller in the tier | |
TIERNAME | Tier Name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | The name of the tier to which the subnetwork belongs | |
TIERRANK | Tier Rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | The rank number assigned to the tier to which the subnetwork belongs | ||
TERMINALCONFIGURATION | Terminal Path | String | False | Default | 0 | 0 | 128 | True | True | terminal configuration used which defines the terminals and the paths between them | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | Globally unique Identifier across geodatabases | ||
SUBNETWORKNAME | Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature participates in | |
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature either has an attachment to or contains elements from | |
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature is contained in | |
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
normaloperatingstatus | Normal Status | Short Integer | True | Electric_Operating_Status | 0 | 0 | 2 | True | False | The normal state for a swtichable device | ||
phasesnormal | Phases Normal | Short Integer | False | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | ||
phasechange | Phase Change | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The new phases to be used in propagation | ||
phasesenergized | Phases Energized | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The phases resulting from propagation | ||
numphasesconstructed | Num Phases Built | Short Integer | True | Electric_Medium_Low_Voltage_Number_Of_Phases | 0 | 0 | 2 | True | False | Number of phases built which can be used to compare to the phasesengergized field to detect connectivity issues | ||
designtype | designtype: Closing Type, Design Type, Fuel Type, Fuse Type, Ground Type, Light Type, Motor Type, Series or Shunt | Short Integer | True | Electric_Combined_Designtypes | 0 | 0 | 2 | True | False | Used to provide engineering information specific to the asset group | ||
grounding | Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye | ||
nominalvoltagelinetoline | nominalvoltage: Nominal Voltage (L-L), Primary Nominal Voltage (L-L), Rated AC Voltage | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
nominalvoltagelinetoground | nominalvoltagelg: Nominal Voltage (L-G), Primary Nominal Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named line to neutral or ground measured in Voltage | ||
secondaryvoltagelinetoline | secondaryvoltagelinetoline: Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L), Voltage (L-L) | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named Secondary line to line voltage measured in Volts | ||
secondaryvoltagelinetoground | secondaryvoltagelinetoground: Secondary Voltage (L-G), Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named Secondary line to neutral or ground measured in Voltage | ||
secondarygrounding | secondarygrounding: Grounding, Secondary Winding Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye on the Secondary Winding | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
ratedpower | ratedpower: AC Output Power, Light Watts, Max Interrupting Current, Rated Current, Rated Load (Watts), Rated Power, Rated Power (Watts), Rated Power kVA, Rated kVA, Rated kVAR | Long Integer | True | 0 | 0 | 4 | True | False | The Rated Power for the equipment | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
fieldoperation | Equipment Field Operation | Short Integer | True | Electric_Device_Operation | 0 | 0 | 2 | True | False | Used to indicate how the equipment can be operated, example hook stick | ||
operatingmechanism | Equipment Field Operating Mechanism | Short Integer | True | Electric_Device_OperatingMechanism | 0 | 0 | 2 | True | False | Used to indicate how the equipment can be operated, example hook stick | ||
iscritical | Is Critical | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment or customer is of a critical nature | ||
material | Material | Short Integer | True | Electric_Wire_Metal_Material | 0 | 0 | 2 | True | False | The material used for the cable | ||
diameter | Diameter | Double | True | Electric_Wire_Diameter_in | 0 | 0 | 8 | True | False | The outside diameter of the cable | ||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
yearmanufactured | Year Manufactured | Date | True | 0 | 0 | 8 | True | False | The year the equipment was manufactured | |||
cablegroupid | Cable Group Number | Short Integer | True | 0 | 0 | 2 | True | False | When conductors are configured in parallel within the same phase, this is the ID of the subcable | |||
conductormaterial | Conductor Material | Short Integer | True | Electric_Connector_Material | 0 | 0 | 2 | True | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_270_SUBNETWO | False | True | SUBNETWORKCONTROLLERNAME |
GDB_270_SUBNETWO_1 | False | True | SUBNETWORKNAME |
GDB_270_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_270_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_48 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricJunctionObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Medium Voltage Control Unit | 27 | A electronic controller used to control the state of equipment used in medium voltage systems, such as switches. |
Elbow | 28 | A device that can be opened, like a switch, but is used to connect underground cables to bushings on pad mounted or underground equipment, such as transformers. Since they can be opened, they can have similar operational behavior as to a switch. |
Fuse | 29 | A device used to protect the system from over current conditions, such as faults. |
Line Monitor and Relay | 31 | Line monitors are frequently used in conjunction with SCADA systems to monitor system conditions. |
Motor and Pump | 32 | Pumps and motors, typically used for waste water or storm water management, considered a critical asset during major outage events. |
Capacitor | 34 | A device used in the correction of the power factor of AC energy. |
Voltage Regulator | 35 | Voltage Regulator devices represent a device that is used in the regulation of voltage on the electric line. It can be a single or polyphase device. |
Primary Service | 36 | A service location or load point used in the delivery of medium voltage power, frequently thought of as a primary meter. |
Recloser | 41 | A self reclosing switch |
Sectionalizer | 42 | A sectionlizing switch |
Switch | 37 | A switch used to control the flow of energy. |
Transformer | 38 | Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase. |
Low Voltage Service | 22 | A service location or load point used in the delivery of low voltage power, frequently thought of as a meter location. |
Key | Value |
---|---|
Name | main.ElectricEdgeObject |
Dataset Type | Table |
Feature Dataset | |
Dataset ID | 271 |
Minimum Client Version | 13.2 |
Alias | Electric Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {1A37672D-6F6D-4956-BB90-99EAD7B40076} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Extension Class ID | |
Details | The Edge Object class represents non-spatial linear features. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
phasesenergized | Phases Energized | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from propagation | |
phasesnormal | Phases Normal | Short Integer | False | Electric_Phase_Attribution_All | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | |
phasechange | Phase Change | Short Integer | True | Electric_Phase_Attribution_All | 0 | 0 | 2 | True | False | The new phases to be used in propagation | ||
material | Material | Short Integer | True | Electric_Wire_Metal_Material | 0 | 0 | 2 | True | False | The material used for the cable | ||
diameter | Diameter | Double | True | Electric_Wire_Diameter_in | 0 | 0 | 8 | True | False | The outside diameter of the cable | ||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
lifecyclestatus | Lifecycle Status | Short Integer | True | Lifecycle_Status_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
installdate | Install Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was installed at this location | |||
inservicedate | In-Service Date | Date | True | 0 | 0 | 8 | True | False | The date the equipment was placed in to service at this location | |||
kcmil | kcmil | Double | True | Electric_Wire_kcmil | 0 | 0 | 8 | True | False | A method of measuring conductor size that stands for thousand circular mils | ||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
normaloperatingstatus | Normal Operating Status | Short Integer | True | Electric_Operating_Status | 0 | 0 | 2 | True | False | The normal state for a swtichable device | ||
nominalvoltagelinetoline | Nominal Voltage (L-L) | Long Integer | True | Electric_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
nominalvoltagelinetoground | Nominal Voltage (L-G) | Long Integer | True | Electric_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named line to neutral or ground measured in Voltage | ||
maxvoltage | Maximum Voltage | Long Integer | True | Electric_Combined_Maximum_Voltage | 0 | 0 | 4 | True | False | The maximum voltage the equipment can sustain | ||
maxoperatingvoltage | Maximum Operating Voltage | Long Integer | True | ELectric_High_Voltage_Maximumm_Operating_Voltage_LL | 0 | 0 | 4 | True | False | The maximum voltage the equipment can be reliable operated at | ||
constructionstatus | Construction Status | Short Integer | True | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
assetid | Asset ID | String | True | 0 | 0 | 2000 | True | False | The Asset ID or Facilit ID of the equipment | |||
designtype | designtype: Design Type, Ground Type | Short Integer | True | Electric_Wire_Insulation_Type | 0 | 0 | 2 | True | False | Used to provide engineering information specific to the asset group | ||
conductormaterial | Condutor Material | Short Integer | True | Electric_Connector_Material | 0 | 0 | 2 | True | False | The material description of the conductor | ||
conductorsize | Conductor Diamter | Double | True | Electric_Wire_Diameter_in | 0 | 0 | 8 | True | False | The wire size of the conductor |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_271_SUBNETWO | False | True | SUBNETWORKNAME |
GDB_271_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_271_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_49 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricEdgeObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Aerial Bare | 101 | Overhead Electric cables that are not shielded |
Aerial Covered | 102 | Overhead Electric cables that are shielded to prevent arcing |
Busbar | 104 | Solid non-flexible conductors, typically found in stations |
Underground | 105 | Underground Conductor Cables |
Neutral | 106 | Electric conductors used as Neutral |
Submarine | 108 | Electric conductors used in under water situations |
Connector | 109 | A Edge feature used to connect non-spatial junction features |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Pole_Depth |
Description | Depth of Pole in ground |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 20 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Generator_Control_Type |
Description | Generator Control Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
401 | Fixed | |
402 | Voltage | |
403 | Swing |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 30 | Generation | designtype |
main.ElectricDevice | 15 | Low Voltage Generation | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Buck_Bandwidth |
Description | Maximum Buck Bandwith |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
-150 | 150 |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Riser_Height |
Description | |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 10000 |
Key | Value |
---|---|
Owner | |
Domain Name | Structure_Pole_Depth_m |
Description | Burried depth of pole |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 10 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Structure_Pole_Class_Medium_Voltage |
Description | List of valid pole classes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 | |
5 | Class 5 | |
6 | Class 6 | |
7 | Class 7 | |
8 | Class 8 | |
9 | Class 9 | |
10 | Class 10 | |
101 | Class H1 | |
102 | Class H2 | |
103 | Class H3 | |
104 | Class H4 | |
105 | Class H5 | |
106 | Class H6 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 121 | Electric Medium Voltage Pole | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_kcmil |
Description | Wire kcmil sizes |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 8 |
Minimum | Maximum |
---|---|
250 | 4000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | kcmil | ||
main.ElectricEdgeObject | 101 | Aerial Bare | kcmil |
main.ElectricEdgeObject | 102 | Aerial Covered | kcmil |
main.ElectricEdgeObject | 104 | Busbar | kcmil |
main.ElectricEdgeObject | 105 | Underground | kcmil |
main.ElectricEdgeObject | 106 | Neutral | kcmil |
main.ElectricEdgeObject | 108 | Submarine | kcmil |
main.ElectricEdgeObject | 109 | Connector | kcmil |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Conductors_Per_Phase |
Description | Valid values for parallel conductors in phase |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 8 |
Minimum | Maximum |
---|---|
1 | 6 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Impedance_Range |
Description | Valid Impendance Range |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 5000 |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Attachment_Height |
Description | Height of attachment |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 100 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | height |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Casing_Material |
Description | Casing Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
9 | Concrete | |
10 | Plastic | |
11 | Steel | |
20 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | ELectric_Combined_Maximumm_Operating_Voltage_LL |
Description | Combined list of maximum operating voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 19 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
600 | 600 V | |
1200 | 1.2 kV | |
7200 | 7.2 kV | |
12000 | 12 kV | |
24000 | 24 kV | |
28000 | 28 kV | |
36000 | 36 kV | |
44000 | 44 kV | |
64000 | 64 kV | |
72500 | 72.5 kV | |
96000 | 96 kV | |
100000 | 100 kV | |
121000 | 121 kV | |
124000 | 124 kV | |
145000 | 145 kV | |
172000 | 172 kV | |
245000 | 245 kV | |
420000 | 420 kV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 101 | Aerial Bare | maxoperatingvoltage |
main.ElectricEdgeObject | 102 | Aerial Covered | maxoperatingvoltage |
main.ElectricEdgeObject | 104 | Busbar | maxoperatingvoltage |
main.ElectricEdgeObject | 105 | Underground | maxoperatingvoltage |
main.ElectricEdgeObject | 106 | Neutral | maxoperatingvoltage |
main.ElectricEdgeObject | 108 | Submarine | maxoperatingvoltage |
main.ElectricEdgeObject | 109 | Connector | maxoperatingvoltage |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Light_Power_Range |
Description | Valid range of watts for lights |
Field Type | Long Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 2500 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 16 | Low Voltage Lighting | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Geometric_Mean_Distance |
Description | Geometric Difference Range |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 100 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Load_Watts |
Description | |
Field Type | Long Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 2 |
Minimum | Maximum |
---|---|
0 | 20000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 22 | Low Voltage Service | ratedpower |
main.ElectricJunctionObject | 22 | Low Voltage Service | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Power_Factor_Range |
Description | Power Factor valid value range |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 9 |
Minimum | Maximum |
---|---|
0 | 1 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Load_Watts |
Description | |
Field Type | Long Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 4 |
Minimum | Maximum |
---|---|
0 | 100000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 32 | Motor and Pump | ratedpower |
main.ElectricDevice | 36 | Primary Service | ratedpower |
main.ElectricJunctionObject | 32 | Motor and Pump | ratedpower |
main.ElectricJunctionObject | 36 | Primary Service | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Junction_Box_Size |
Description | List of valid junction box sizes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Trench_Depth |
Description | Range domain for trench depth |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
1 | 100 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 104 | Wire Trench | distance |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Pole_Depth |
Description | Medium Voltage in ground depth |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 2 |
Minimum | Maximum |
---|---|
0 | 6 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 121 | Electric Medium Voltage Pole | depth |
main.StructureJunction | 122 | Electric Low Voltage Pole | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Circuit_Breaker_Continuous_Amps |
Description | Medium Voltage Circuit Breaker Continuous Amps Ratings |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
200 | 200 A | |
600 | 600 A | |
1250 | 1250 A | |
1600 | 1600 A | |
2000 | 2000 A | |
2500 | 2500 A | |
3000 | 3000 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 26 | Circuit Breaker | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Lighting |
Description | Low Voltage Lighting |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A light of unknown type connected to the low voltage system |
301 | Floodlight LV | A flood light connected to the low voltage system |
302 | Streetlight LV | A street light connected to the low voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 16 | Low Voltage Lighting | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Support_Pole_Depth |
Description | Support pole buried depth |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 30 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 123 | Wire Support Pole | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ohms_per_KM |
Description | Range domain of valid values for Electric Cable resistance per KM |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 8 |
Minimum | Maximum |
---|---|
0 | 999999 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Tap_Change_Percent_Double |
Description | Valid Tap Change Percent Rage |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
-15 | 15 |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Junction_Box_Material |
Description | List of valid junction box materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Stainless Steel | |
4 | Fiberglass | |
6 | Steel | |
9 | Precast Concrete | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 104 | Wire Junction Box | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Voltage_Offset |
Description | Voltage Offset Range |
Field Type | Long Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 2 |
Minimum | Maximum |
---|---|
0 | 1000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 31 | Line Monitor and Relay | secondaryvoltagelinetoline |
main.ElectricJunctionObject | 27 | Medium Voltage Control Unit | secondaryvoltagelinetoline |
Key | Value |
---|---|
Owner | |
Domain Name | Yes_No |
Description | Valid Yes, No values |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 21 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Yes | |
2 | No |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Line_Duct_Material |
Description | List of duct materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3 | Composite | |
4 | Fiberglass | |
8 | Poured Concrete | |
9 | Precast Concrete | |
10 | Plastic | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 106 | Electric Low Voltage Conduit | materialcode |
main.StructureLine | 107 | Electric Medium Voltage Conduit | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_FullDiameter |
Description | |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 5 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Generation |
Description | Medium Voltage Generation |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Medium Voltage Generation. |
120 | Interconnect |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 30 | Generation | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Medium_Voltage_Connection_Point |
Description | Medium Voltage Connection Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Connection Point of unknown type |
80 | Busbar Tap | A medium voltage busbar tap used for connecting lines at mid line. |
82 | Overhead Tap | A medium voltage overhead tap used for connecting lines at mid line. |
85 | Neutral Connection | A medium voltage connection point that allows connectivity between a phased conductor and the neutral line. |
87 | Underground Tap | A medium voltage point used to connect a single phase. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 8 | Medium Voltage Connection Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Symbol_Rotation |
Description | Valid range of degrees for rotation |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 46 |
Minimum | Maximum |
---|---|
0 | 359 |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Anchor_Guy_Depth |
Description | Minimum and maximum anchor guy depth |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 20 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 102 | Wire Structure Guy | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Pedestal_Material |
Description | List of valid pedestal materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6 | Steel | |
7 | Wood | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 107 | Wire Pedestal | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Phase_Attribution |
Description | Low Voltage Phase labels |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 42 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | c | |
2 | b | |
3 | bc | |
4 | a | |
5 | ac | |
6 | ab | |
7 | abc |
Key | Value |
---|---|
Owner | |
Domain Name | AP_Configure_Categories_2 |
Description | Valid values for D_Configuration table |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Not Evaluated | |
1 | Evaluated | |
2 | Exclusive | |
3 | Remove when applied | |
4 | Always remove when applied | |
5 | Keep when applied | |
6 | Always keep when applied |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Crossarm_Height_m |
Description | |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
0 | 20 |
Key | Value |
---|---|
Owner | |
Domain Name | Construction_Status |
Description | Valid Construction statues for the assets |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 95 |
Code | Description | Details |
---|---|---|
0 | Warehouse | |
1 | Abandoned | |
2 | Removed | |
3 | Design | |
4 | Approved | |
5 | Under construction | |
6 | Construction complete | |
7 | Maintenance |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDeleted |
Description | Indicates if a subnetwork has been marked for deletion. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Switch_Continuous_Amps |
Description | Medium Voltage Switch Continuous Amps |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
600 | 600 A | |
900 | 900 A | |
1200 | 1200 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 37 | Switch | ratedpower |
main.ElectricJunctionObject | 37 | Switch | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Minimum_Bend_Radius_in |
Description | Minimum Bend Radius for Ducts and Conduits |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
1.5 | 24 |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Minimum_Bend_Radius_m |
Description | Minimum Bend Radius for Ducts and Conduits |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 0 |
Minimum | Maximum |
---|---|
38.1 | 610 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ground_Configuration |
Description | List of valid ground types for the distribution system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 45 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Grounded Wye | |
2 | Wye | |
3 | Delta | |
4 | Grounded Delta | |
5 | Direct Current |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Power_Factor_Correcting |
Description | Medium Voltage Power Factor Correcting |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A power factor correcting device of unknown type in the medium voltage system |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 34 | Capacitor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Line_Monitor_and_Relay |
Description | Medium Voltage Line Monitor and Relay |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Line Monitor and Relay | Unknown type of Medium Voltage Line Monitor and Relay. |
601 | Fault Indicator | A Fault indicator used in medium voltage systems. |
602 | Instrument Transformer | An Instrument Transformer used in medium voltage systems. |
607 | Relay | A relay used in medium voltage systems. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 31 | Line Monitor and Relay | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Pedestal_Depth |
Description | Minimum and maximum pedestal depth |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 5 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 107 | Wire Pedestal | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Trench_Width |
Description | Depth of trench |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 30 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 104 | Wire Trench | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Fuse_Link_Type |
Description | Types of fuse links |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
10 | K | |
11 | T | |
12 | MS | |
13 | QH | |
14 | Standard | |
15 | SloFast |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Vault_Depth |
Description | Dept of vault |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 100 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 110 | Wire Vault | depth |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FeatureSourceID |
Description | The source feature class name in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Association | |
2 | System Junction | |
3 | System Junction Object | |
4 | StructureJunction | |
5 | StructureLine | |
6 | StructureBoundary | |
7 | Structure Junction Object | |
8 | Structure Edge Object | |
9 | ElectricDevice | |
10 | ElectricLine | |
11 | ElectricAssembly | |
12 | ElectricJunction | |
13 | ElectricSubnetLine | |
14 | Electric Junction Object | |
15 | Electric Edge Object |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Combined_Material |
Description | Combined list of structure materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Stainless Steel | |
3 | Composite | |
4 | Fiberglass | |
6 | Steel | |
7 | Wood | |
8 | Poured Concrete | |
9 | Precast Concrete | |
10 | Plastic | |
11 | Cast Iron | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | AP_Configure_Categories_3 |
Description | Valid values for D_Configuration table |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Not Evaluated | |
1 | Evaluated | |
2 | Exclusive | |
3 | Remove when applied | |
4 | Always remove when applied | |
5 | Keep when applied | |
6 | Always keep when applied |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsContentVisible |
Description | Indicates if the content or attachment association is visible for containment associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FlowDirection |
Description | Indicates how the feature flows in network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 28 |
Code | Description | Details |
---|---|---|
1 | With digitized | |
2 | Against digitized | |
3 | Indeterminate |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierTopologyType |
Description | The type of topology for each tier. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Radial | |
2 | Mesh |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_AssociationStatus |
Description | Indicates how the feature participates in associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 36 |
# of Assignments | 95 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Container | |
2 | Structure | |
4 | Content | |
5 | Content and Container | |
6 | Content and Structure | |
8 | Attachment | |
9 | Attachment and Container | |
10 | Attachment and Structure | |
12 | Attachment and Content | |
13 | Attachment and Content and Container | |
14 | Attachment and Content and Structure | |
16 | Visible Content | |
17 | Visible Content and Container | |
18 | Visible Content and Structure | |
24 | Visible Content and Attachment | |
25 | Visible Content and Attachment and Container | |
26 | Visible Content and Attachment and Structure | |
32 | Connectivity | |
33 | Connectivity and Container | |
34 | Connectivity and Structure | |
36 | Connectivity and Content | |
37 | Connectivity and Content and Container | |
38 | Connectivity and Content and Structure | |
40 | Connectivity and Attachment | |
41 | Connectivity and Attachment and Container | |
42 | Connectivity and Attachment and Structure | |
44 | Connectivity and Attachment and Content | |
45 | Connectivity and Attachment and Content and Container | |
46 | Connectivity and Attachment and Content and Structure | |
48 | Connectivity and Visible Content | |
49 | Connectivity and Visible Content and Container | |
50 | Connectivity and Visible Content and Structure | |
56 | Connectivity and Visible Content and Attachment | |
57 | Connectivity and Visible Content and Attachment and Container | |
58 | Connectivity and Visible Content and Attachment and Structure |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDirty |
Description | Indicates if a subnetwork is clean, dirty, or invalid. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Clean | |
1 | Dirty | |
2 | Invalid |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricSubnetLine | ISDIRTY | ||
main.ElectricSubnetLine | 0 | Unknown | ISDIRTY |
main.ElectricSubnetLine | 1 | Electric Distribution | ISDIRTY |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_UnknownAssetType |
Description | The AssetType domain for the Unknown AssetGroup. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Fuse |
Description | Low Voltage Fuse |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Low Voltage Fuse |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 14 | Low Voltage Fuse | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | AP_Configure_Categories_1 |
Description | Valid values for D_Configuration table |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Not Evaluated | |
1 | Evaluated | |
2 | Exclusive | |
3 | Remove when applied | |
4 | Always remove when applied | |
5 | Keep when applied | |
6 | Always keep when applied |
Key | Value |
---|---|
Owner | |
Domain Name | Domain |
Description | |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 0 |
# of Assignments | 0 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Service |
Description | Low Voltage Service |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown type of service metering point in the low voltage system |
427 | Low Voltage Premise LV | A service location of a customer connected to the low voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 22 | Low Voltage Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Line_Electric_Medium_Voltage_Conduit |
Description | The Asset Types for the Electric Medium Voltage Conduit |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Medium Voltage Conduit. |
112 | Conduit |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 107 | Electric Medium Voltage Conduit | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Manager |
Description | The manager of the asset |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Owner |
Description | The owner of the asset |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Assembly_Medium_Voltage_Switch_Bank |
Description | Medium Voltage Switch Bank |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A container of equipment associated with a switch in the medium voltage system |
309 | Pad Mounted Switch Gear | A container of pad mounted equipment associated with a switch in the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricAssembly | 18 | Switch Gear | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_Metal_Material |
Description | The base metal material type of the wire |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6 | Steel | |
15 | Aluminum | |
25 | Copper |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | material | ||
main.ElectricEdgeObject | material | ||
main.ElectricEdgeObject | 101 | Aerial Bare | material |
main.ElectricEdgeObject | 102 | Aerial Covered | material |
main.ElectricEdgeObject | 104 | Busbar | material |
main.ElectricEdgeObject | 105 | Underground | material |
main.ElectricEdgeObject | 106 | Neutral | material |
main.ElectricEdgeObject | 108 | Submarine | material |
main.ElectricEdgeObject | 109 | Connector | material |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_High_Voltage_Transformer |
Description | High Voltage Transformer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A transformer of unknown type used in the high voltage system |
205 | Power Transformer HV->MV | A station located transformer used to convert power from high voltage to medium voltage |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 11 | High Voltage Transformer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Generation |
Description | Low Voltage Generation |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Low Voltage Generation. |
284 | Residential Photovoltaic Solar LV | A low Wattage Photovoltaic solar. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 15 | Low Voltage Generation | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Line_Monitor_and_Relay |
Description | Medium Voltage Line Monitor and Relay |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Medium Voltage Line Monitor and Relay. |
601 | Fault Indicator | A Fault indicator used in medium voltage systems. |
602 | Instrument Transformer | An Instrument Transformer used in medium voltage systems. |
607 | Relay | A relay used in medium voltage systems. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 31 | Line Monitor and Relay | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Motor |
Description | Low Voltage Motor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Low Voltage Motor |
341 | Single Phase Motor LV | A low Voltage single phase motor. |
342 | Three Phase Motor LV | A low Voltage three phase motor. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 18 | Low Voltage Motor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Motor_and_Pump |
Description | Medium Voltage Motor and Pump |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Motor and Pump |
621 | Single Phase Motor | A medium voltage single phase motor. |
622 | Single Phase Pump | A medium voltage single phase pump and motor. |
623 | Three Phase Motor | A medium voltage three phase motor. |
624 | Three Phase Pump | A medium voltage three phase pump and motor. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 32 | Motor and Pump | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Low_Voltage_Switch |
Description | Low Voltage Switch |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown switch type used in the low voltage system |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 23 | Low Voltage Switch | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Monitor_Equipment_Type |
Description | Monitoring Equipment type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3 | CT | |
4 | CT-PT | |
5 | PT | |
1 | Analog RTU | |
2 | Digital RTU |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Switch |
Description | Medium Voltage Switch |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown switch type used in the medium voltage system |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 37 | Switch | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Support_Pole_Height |
Description | Support Pole Heights |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
35 | 35 Feet | |
40 | 40 Feet | |
45 | 45 Feet | |
50 | 50 Feet | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 123 | Wire Support Pole | height |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Circuit_Breaker |
Description | Medium Voltage Circuit Breaker |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | a mechanical switching device of unknown type in the medium voltage system |
503 | Three Phase Circuit Breaker | A mechanical switching device used on a three phases in the medium voltage system |
513 | Circuit Source | A mechanical switching device used on a three phases in the medium voltage system that can also be a subnetwork controller |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 26 | Circuit Breaker | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Aerial_Bare |
Description | Aerial Bare Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Aerial Bare. |
903 | Medium Voltage | A object representing a single Aerial Bare Cable used in the medium voltage system |
904 | Low Voltage AC | A object representing a single Aerial Bare Cable used in the low voltage AC system |
906 | Static Wire |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 101 | Aerial Bare | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Elbow |
Description | Medium Voltage Elbow |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Elbow |
5 | Underground Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 28 | Elbow | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Fuse |
Description | Medium Voltage Fuse |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Fuse |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 29 | Fuse | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Recloser |
Description | Medium Voltage Recloser Asset Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Recloser |
4 | Overhead Bank | |
5 | Underground Bank | |
734 | Overhead Recloser - Controller | A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller |
738 | Pad Mounted Recloser - Controller | A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 41 | Recloser | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Regulator |
Description | Medium Voltage Regulator |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A voltage regulating device used in the medium voltage system |
4 | Overhead Bank | |
5 | Underground Bank | |
6 | Station Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 35 | Voltage Regulator | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Sectionalizer |
Description | Medium Voltage Secitionalizer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Sectionalizer |
4 | Overhead Bank | |
5 | Underground Bank |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 42 | Sectionalizer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Transformer |
Description | Medium Voltage Transformer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 21 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A transformer of unknown type used in the medium voltage system |
785 | Overhead Single Phase - MV->LV | A pole mounted single phase transformer used to convert power from medium voltage to low voltage |
788 | Overhead Three Phase - MV->LV | A pole mounted three phase transformer used to convert power from medium voltage to low voltage |
789 | Pad Mounted Single Phase - MV->LV | A pad mounted single phase transformer used to convert power from medium voltage to low voltage |
792 | Pad Mounted Three Phase - MV->LV | A pad mounted three phase transformer used to convert power from medium voltage to low voltage |
793 | Submersible Single Phase - MV->LV | A medium voltage submersible single phase transformer. |
794 | Submersible Three Phase - MV->LV | A medium voltage to low voltage three phase transformer that can be used in locations prone to flooding |
795 | Overhead Open Delta - MV->LV | A single feature representing pole mounted three phase open delta transformer that converts power from medium voltage to low voltage |
796 | Overhead Open Wye - MV->LV | A single feature representing pole mounted three phase open wye transformer that converts power from medium voltage to low voltage |
797 | Pad Mounted Open Delta - MV->LV | A pad mounted three phase transformer using two single phase delta transformers to convert power from medium voltage to low voltage |
798 | Pad Mounted Open Wye - MV->LV | A pad mounted three phase transformer using two single phase wye transformers to convert power from medium voltage to low voltage |
803 | Overhead Single Phase Step - MV->MV | A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
804 | Overhead Three Phase Step - MV->MV | A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
807 | Pad Mounted Single Phase Step - MV->MV | A pad mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
808 | Pad Mounted Three Phase Step - MV->MV | A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
811 | Submersible Single Phase Step - MV->MV | A medium voltage single phase transformer used to increase or decrease voltage within the medium voltage range that uses a directional terminal configuration that can be used in locations prone to flooding |
812 | Submersible Three Phase Step - MV->MV | A medium voltage three phase transformer used to step up or down the voltage to a different medium voltage level that can be used in locations prone to flooding using a utility network directional terminal configuration |
816 | Overhead Three Phase Step Up - LV->MV | A pole mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller |
820 | Pad Mounted Three Phase Step Up - LV->MV | A pad mounted single phase transformer used to convert power from low voltage to medium voltage |
822 | Overhead Single Phase Step Up - LV->MV | |
824 | Pad Mounted Single Phase Step Up - LV->MV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 38 | Transformer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Device_Medium_Voltage_Service |
Description | Medium Voltage Service |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown type of service metering point in the medium voltage system |
704 | Primary Meter | A service location of a customer connected to the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 36 | Primary Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Aerial_Covered |
Description | Aerial Covered Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Aerial Covered. |
903 | Medium Voltage | A object representing a single Aerial Covered or Shielded Cable used in the medium voltage system |
904 | Low Voltage AC | A object representing a single Aerial Covered or Shielded Cable used in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 102 | Aerial Covered | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Busbar |
Description | Busbar |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Busbar. |
903 | Medium Voltage | A object representing a single busbar in the medium voltage system |
904 | Low Voltage AC | A object representing a single busbar in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 104 | Busbar | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Connector |
Description | Valid Connector Asset Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Connector. |
903 | Medium Voltage | A object used to connect objects in the medium voltage system |
904 | Low Voltage AC | A object used to connect objects in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 109 | Connector | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Neutral |
Description | Neutral |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Neutral. |
910 | Overhead Bare | A bare overhead neutral. |
911 | Overhead Shielded | An overhead shielded overhead neutral. |
912 | Underground Shielded | An underground shielded overhead neutral. |
913 | Concentric | A object that represents the electrical neutral wire of an underground cable |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 106 | Neutral | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Electric_High_Voltage_Pole |
Description | The Asset Types for the Electric Distribution Asset Group High Voltage Pole |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pole of Unknown type primarily used to support high voltage cables |
335 | H-Frame HV | |
337 | Pole HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Submarine |
Description | Submarine Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Submarine. |
903 | Medium Voltage | A object representing a single submarine cable used in the medium voltage system |
904 | Low Voltage AC | A object representing a single submarine cable used in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 108 | Submarine | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_EdgeObject_Underground |
Description | Underground |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Underground. |
903 | Medium Voltage | A object representing a single underground cable, used in the medium voltage system |
904 | Low Voltage AC | A object representing a single underground cable, used in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | 105 | Underground | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Low_Voltage_Service |
Description | Low Voltage Service |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown type of service metering point in the low voltage system |
421 | Single Phase Commercial LV | A single phase metering device used for a commercial customer in the low voltage system |
422 | Single Phase Residential LV | A single phase metering device used for a residential customer in the low voltage system |
423 | Three Phase Commercial LV | A three phase metering device used for a commercial customer in the low voltage system |
424 | Three Phase Residential LV | A three phase metering device used for a residential customer in the low voltage system |
425 | Unmetered Load LV | A point representing load not associated with a customer in the low voltage system |
428 | Car Charger LV | A Car Charge connected to the Low Voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 22 | Low Voltage Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Control_Unit |
Description | Medium Voltage Controller |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Control Unit | A device used to control unknown equipment types in the medium voltage system |
521 | Capacitor | A device used to control a capacitor in the medium voltage system |
522 | Circuit Breaker | A device used to control a circuit breaker in the medium voltage system |
523 | Recloser | A device used to control a recloser in the medium voltage system |
524 | Transfer Switch Controller | A device used to control a transfer switch in the medium voltage system |
525 | Regulator | A device used to control a regulator in the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 27 | Medium Voltage Control Unit | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Fuse_Continuous_Amps |
Description | List of valid continuous amps for a fuse |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 27 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3 | 3 A | |
7 | 7 A | |
10 | 10 A | |
15 | 15 A | |
20 | 20 A | |
25 | 25 A | |
30 | 30 A | |
40 | 40 A | |
50 | 50 A | |
65 | 65 A | |
80 | 80 A | |
100 | 100 A | |
125 | 125 A | |
150 | 150 A | |
175 | 175 A | |
180 | 180 A | |
200 | 200 A | |
225 | 225 A | |
250 | 250 A | |
300 | 300 A | |
350 | 350 A | |
400 | 400 A | |
450 | 450 A | |
500 | 500 A | |
550 | 550 A | |
600 | 600 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 28 | Elbow | ratedpower |
main.ElectricDevice | 29 | Fuse | ratedpower |
main.ElectricJunctionObject | 28 | Elbow | ratedpower |
main.ElectricJunctionObject | 29 | Fuse | ratedpower |
main.ElectricJunctionObject | 41 | Recloser | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Elbow |
Description | Medium Voltage Elbow |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Elbow | Unknown type of Medium Voltage Elbow. |
2 | AC Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 28 | Elbow | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Fuse |
Description | Medium Voltage Fuse |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Fuse | Unknown type of Medium Voltage Fuse. |
1 | AC Overhead | |
2 | AC Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 29 | Fuse | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Motor_and_Pump |
Description | Medium Voltage Motor & Pump |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Motor | Unknown type of Medium Voltage Motor and Pump. |
621 | Single Phase Motor | A medium voltage single phase motor. |
622 | Single Phase Pump | A medium voltage single phase pump and motor. |
623 | Three Phase Motor | A medium voltage three phase motor. |
624 | Three Phase Pump | A medium voltage three phase pump and motor. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 32 | Motor and Pump | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Low_Voltage_Submersible_Conductor |
Description | Low VoltageSubmersibleConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
101 | Submersible LV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 38 | Low Voltage Submersible Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Power_Factor_Correcting |
Description | Medium Voltage Power Factor Correcting |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Capacitor | A power factor correcting device of unknown type in the medium voltage system |
1 | Overhead | |
2 | Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 34 | Capacitor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Recloser |
Description | Medium Voltage Recloser |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Recloser | Unknown type of Medium Voltage Recloser. |
1 | Overhead | |
2 | Underground | |
4 | Overhead - Controller | |
5 | Underground - Controller | |
734 | Overhead Three Phase Recloser - Controller | A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller |
738 | Pad Mounted Recloser - Controller | A medium voltage three phase reclosing switch where all three phases are operated the same way at all times, also used as a subnetwork controller |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 41 | Recloser | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Regulator |
Description | Medium Voltage Regulator |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Regulator | A voltage regulating device used in the medium voltage system |
1 | Overhead | |
2 | Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 35 | Voltage Regulator | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Sectionalizer |
Description | Medium Voltage Secitionalizer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Sectionalizer | Unknown type of Medium Voltage Sectionalizer. |
1 | Overhead | |
2 | Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 42 | Sectionalizer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Service |
Description | Medium Voltage Service |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Service | A unknown type of service metering point in the medium voltage system |
701 | Primary Meter - Industrial Customer MV | A metering device used for a industrial customer in the medium voltage system |
702 | Primary Meter - Utility Customer MV | A metering device used for a utility customer in the medium voltage system |
704 | Primary Meter | A service location of a customer connected to the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 36 | Primary Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Winding_Ratio_Double |
Description | Transformer and Regulator winding ratios |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 30 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
50 | 50:5 | |
60 | 60:5 | |
75 | 75:5 | |
80 | 80:5 | |
100 | 100:5 | |
125 | 125:5 | |
150 | 150:5 | |
200 | 200:5 | |
250 | 250:5 | |
300 | 300:5 | |
400 | 400:5 | |
500 | 500:5 | |
600 | 600:5 | |
800 | 800:5 | |
1000 | 1000:5 | |
1200 | 1200:5 | |
1500 | 1500:5 | |
1600 | 1600:5 | |
2000 | 2000:5 | |
3000 | 3000:5 | |
4000 | 4000:5 | |
5000 | 5000:5 | |
6000 | 6000:5 | |
8000 | 8000:5 | |
5 | 5:5 | |
10 | 10:5 | |
15 | 15:5 | |
20 | 20:5 | |
25 | 25:5 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Switch |
Description | Medium Voltage Switch |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Switch | A unknown switch type used in the medium voltage system |
1 | Overhead | |
2 | Underground |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 37 | Switch | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_JunctionObject_Medium_Voltage_Transformer |
Description | Medium Voltage Transformer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Transformer | A transformer of unknown type used in the medium voltage system |
785 | Overhead Single Phase - MV->LV | A pole mounted single phase transformer used to convert power from medium voltage to low voltage |
786 | Station - MV->LV | A station located transformer used to convert power from medium voltage to low voltage |
788 | Overhead Three Phase - MV->LV | A pole mounted three phase transformer used to convert power from medium voltage to low voltage |
789 | Pad Mounted Single Phase - MV->LV | A pad mounted single phase transformer used to convert power from medium voltage to low voltage |
792 | Pad Mounted Three Phase - MV->LV | A pad mounted three phase transformer used to convert power from medium voltage to low voltage |
794 | Submersible Three Phase - MV->LV | A medium voltage to low voltage three phase transformer that can be used in locations prone to flooding |
803 | Overhead Single Phase Step - MV->MV | A pole mounted single phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
804 | Overhead Three Phase Step - MV->MV | A pole mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
808 | Pad Mounted Three Phase Step - MV->MV | A pad mounted three phase transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
813 | Station Step - MV->MV | A station located transformer used to convert power from medium voltage to a different medium voltage that can also be used as a subnetwork controller |
816 | Overhead Three Phase Step Up - LV->MV | A pole mounted three phase transformer used to convert power from low voltage to medium voltage that can also be used as a subnetwork controller |
822 | Overhead Single Phase Step Up - LV->MV | |
824 | Pad Mounted Single Phase Step Up - LV->MV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunctionObject | 38 | Transformer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Low_Voltage_Attachment |
Description | Low Voltage Attachment |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A connection point used for associations from unknown low voltage lines to supporting structures |
101 | Overhead LV | A connection point used for associations from aerial high voltage ac lines to poles and towers. |
102 | Underground LV | A connection point used for associations from underground low voltage ac lines to supporting structures |
107 | Submersible LV | A connection point used for associations from submersible low voltage ac lines to supporting structures |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 4 | Low Voltage Attachment | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Low_Voltage_Connection_Point |
Description | Low Voltage Connection Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Low Voltage Connection Point of unknown type |
124 | Busbar Tap LV | Low Voltage Connection Point for AC Busbar |
128 | Overhead Tap LV | A low voltage overhead tap used for connecting AC lines at mid line. |
134 | Underground Tap LV | A medium voltage point used to connect AC Cable. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 5 | Low Voltage Connection Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Line_Aerial_Support_Material |
Description | List of materials used for aerial supports |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | Fiberglass | |
6 | Steel | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 103 | Wire Aerial Support | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Low_Voltage_Line_End |
Description | Low Voltage Line End |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A location where line ends can allow connectivity to another cable or equipment in the low voltage AC system |
120 | Overhead Splice LV | |
126 | Underground Splice LV | |
141 | Overhead Line End LV | A location where a cable is cut or split and can allow connectivity to another cable or equipment in the low voltage AC system |
143 | Underground Terminator LV | A low voltage point found at the end of an AC Underground Cable |
149 | Overhead Wire Change LV | A location where a change in phases in a overhead line occur |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 6 | Low Voltage Line End | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsConnected |
Description | Indicates if the feature is connected to a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 65 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True | |
2 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Spatial_Confidence |
Description | Confidence in the accuracy of the spatial data |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | High | |
2 | Medium | |
3 | Low |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Medium_Voltage_Attachment |
Description | Medium Voltage Attachment |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A connection point used for associations from unknown medium voltage lines to supporting structures |
60 | Overhead | A connection point used for associations from aerial medium voltage lines to poles and towers. |
61 | Underground | A connection point used for associations from underground medium voltage lines to supporting structures |
63 | Submersible | A connection point used for associations from submersible medium voltage lines to supporting structures |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 7 | Medium Voltage Attachment | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Junction_Medium_Voltage_Line_End |
Description | Medium Voltage Line End |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A location where line ends can allow connectivity to another cable or equipment in the medium voltage system |
81 | Overhead Splice | |
84 | Underground Splice | |
161 | Overhead Line End | A medium voltage line end point used on overhead lines, like a dead-end. |
162 | Underground Terminator | A medium voltage underground cable terminator like a strain. |
163 | Overhead Wire Change | A medium voltage location where the number of phases change and not all wires are cut at this point. |
164 | Underground Wire Change | A medium voltage location where the number of phases change and not all wires are cut at this point used in underground for data migration. |
173 | Open Point |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricJunction | 9 | Medium Voltage Line End | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Low_Voltage_Overhead_Conductor |
Description | Low Voltage Conductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A group of unknown conductor types in the low Voltage system |
100 | Overhead LV | A group of aerial conductors in the low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 6 | Low Voltage Overhead Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Low_Voltage_Service |
Description | List of asset types for Low Voltage Services |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A unknown type of service cable in the low voltage system |
110 | Overhead Service LV | A aerial cable(s) used to provide service to customers in a low voltage AC system |
112 | Underground Service LV | A underground cable(s) used to provide service to customers in a low voltage AC system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 13 | Low Voltage Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Low_Voltage_Underground_Conductor |
Description | Low VoltageUndergroundConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
102 | Underground LV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 37 | Low Voltage Underground Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Medium_Voltage_Busbar |
Description | Medium Voltage Busbar |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A group of solid conductors used in the medium voltage system |
140 | Cabinet Single Phase | A single solid conductor used in a cabinet in the medium voltage system |
141 | Cabinet Three Phase | A group of three solid conductors used in a cabinet in the medium voltage system |
143 | Station Three Phase | A group of three solid conductors used in a station in the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 8 | Medium Voltage Busbar | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Medium_Voltage_Connector |
Description | Medium Voltage Connector |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Medium Voltage Connector on unknown type |
180 | Single Phase | A medium voltage single phase connector used in lieu of explicit connectivity associations |
181 | Three Phase | A medium voltage three phase connector used in lieu of explicit connectivity associations |
182 | Two Phase | A medium voltage two phase connector used in lieu of explicit connectivity associations |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 10 | Medium Voltage Connector | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Medium_Voltage_Overhead_Conductor |
Description | Medium Voltage Conductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A group of unknown conductor types in the medium Voltage system |
160 | Overhead Single Phase | A group of aerial conductors in the medium voltage system of the same phase |
161 | Overhead Three Phase | A group of aerial conductors in the medium voltage system representing all three phases |
162 | Overhead Two Phase | A group of aerial conductors in the medium voltage system representing two phases |
168 | Overhead Neutral |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 9 | Medium Voltage Overhead Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Medium_Voltage_Submersible_Conductor |
Description | Medium VoltageSubmersibleConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
163 | Submersible Single Phase | |
164 | Submersible Three Phase |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 35 | Medium Voltage Submersible Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Connector_Material |
Description | List of valid Connector Common Conductor Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 17 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1001 | ACSR | |
1002 | ACSR/AW | |
1003 | ACSR/TW | |
1004 | ACSS/AW | |
1005 | ACSS/TW | |
1006 | AAC | |
1007 | AAC/TW | |
1008 | AAAC | |
1009 | ACAR | |
1010 | Welded Aluminum Sheath | |
1011 | Copper Wires with Aluminum Sheath | |
1012 | Copper Wires with Copper Sheath | |
1013 | Copper Wires with Lead Sheath |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Electric_Line_Medium_Voltage_Underground_Conductor |
Description | Medium VoltageUndergroundConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
165 | Underground Single Phase | |
166 | Underground Three Phase | |
167 | Underground Two Phase |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 34 | Medium Voltage Underground Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_JunctionObject_Pole |
Description | Junctions used to represent support poles in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Pole. |
101 | Pole | A object used to represent a Pole of any kind |
102 | Ornamental Pole | A decorative type pole, typically used for street lights |
107 | Tower Leg | A structure used for supporting the lower part of transmission tower |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunctionObject | 120 | Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Boundary_Electric_Substation_Boundary |
Description | The Asset Types for the Electric Distribution Asset Group Substation Boundary |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A polygon used to define the outline of a station of unknown type |
82 | Distribution Substation | A polygon used to represent the location of a Distribution Substation |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 102 | Electric Substation Boundary | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Switch_Continuous_Amps |
Description | Low Voltage Switch Continuous Amps |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
15 | 15 A | |
20 | 20 A | |
30 | 30 A | |
45 | 45 A | |
50 | 50 A | |
60 | 60 A | |
100 | 100 A | |
125 | 125 A | |
200 | 200 A | |
225 | 225 A | |
300 | 300 A | |
320 | 320 A | |
800 | 800 A | |
1200 | 1200 A | |
2500 | 2500 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 23 | Low Voltage Switch | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Electric_Low_Voltage_Pole |
Description | The Asset Types for the Electric Distribution Asset Group Low Voltage Pole |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pole of unknown type that is used to support cables in the low voltage system |
314 | Pole LV | |
315 | Ornamental LV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 122 | Electric Low Voltage Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Electric_Medium_Voltage_Pole |
Description | The Asset Types for the Electric Distribution Asset Group Medium Voltage Pole |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pole of unknown type used to support aerial cables in the medium voltage system |
321 | H-Frame MV | A two pole structure used to support aerial cables in the medium voltage system |
324 | Primary Pole | A Pole used to support aerial cables in the medium voltage system |
329 | Lattice | A reinforced structure, typically steel, used to support aerial cables in the medium voltage system |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 121 | Electric Medium Voltage Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_Insulation_Type |
Description | Electric Wire Insulation Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 6 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bare Wire | |
2 | Cross linked polyethylene | |
3 | Ethylene propylene rubber | |
4 | Paper insulated lead covered | |
5 | Polyethylene | |
6 | PVC | |
7 | Tree retardant cross linked polyethylene |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | designtype | ||
main.ElectricEdgeObject | 102 | Aerial Covered | designtype |
main.ElectricEdgeObject | 104 | Busbar | designtype |
main.ElectricEdgeObject | 105 | Underground | designtype |
main.ElectricEdgeObject | 106 | Neutral | designtype |
main.ElectricEdgeObject | 108 | Submarine | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Marker |
Description | Junctions used to represent markers in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Marker. |
461 | Aerial Marker | An aerial marker for overhead wires. |
462 | Buried Cable Marker | A location marker and warning for buried cables. |
463 | Overhead Water Crossing | A water crossing marker and warning for overhead cables over bodies of water. |
464 | Submerged Cable Marker | A marker used to indicate submerged cables at this location, typically found in large bodies of water. |
465 | Covered Marker | A location marker and warning for buried cables. |
466 | Terrain Marker | A surface marker used to make cables |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Cabinet |
Description | The Asset Types for the Structure Junction Asset Group Wire Cabinet |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Cabinet. |
101 | Electric Cabinet | A cabinet used for containing wire devices, junctions, and busbars. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 101 | Wire Cabinet | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Motor_Assistance_Type |
Description | Motor Starting Assistance Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Auto Transformer | |
2 | Capacitor | |
3 | Inductor | |
4 | Inductor & Resistor | |
5 | Resistor | |
6 | Star-Delta |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Guy |
Description | Junctions used to represent guy wires in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Guy. |
41 | Anchor Guy | An wire Anchor Guy structure used to help provide support for the upper portion of a pole. Sometimes referred to as a down guy. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 102 | Wire Structure Guy | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Handhole |
Description | Junctions used to represent handholds in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Manhole. |
81 | Handhole | An wire Handhole represents an access box frequently used to access low voltage or service conductors. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 103 | Wire Handhole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Junction_Box |
Description | Junctions used to represent junction boxes in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Junction Box. |
121 | Junction Box | An wire Junction box is typically a water tight surface structure used for low voltage connections. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 104 | Wire Junction Box | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Pedestal |
Description | Junctions used to represent pedestals in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Pedestal |
241 | Pedestal | An Wire Pedestal is typically a short vertical structures typically used to mount a customer meter devices on. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 107 | Wire Pedestal | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Support_Pole |
Description | Junctions used to represent support poles in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Support Pole. |
326 | Stub | An Wire Support Stub structure used to pull an aerial support cable attached to a larger medium voltage pole or to reinforce the base of a larger medium voltage pole. |
327 | Push Brace | An Wire Support Push Brace structure used to push against a medium voltage pole when an anchor guy cannot be used. |
328 | Support Column | Wire Support Poles are Vertical support structures typically used to "Brace" an other pole when a Anchor Guy cannot be used to support it. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 123 | Wire Support Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Wire_Vault |
Description | Junctions used to represent vaults in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Vault. |
361 | Vault | An Wire Vaults is typically a concrete room that will contain surface mounted equipment, like transformers. |
362 | Manhole | Access point for underground assets |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 110 | Wire Vault | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Line_Electric_Low_Voltage_Conduit |
Description | The Asset Types for the Electric Low Voltage Conduit |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Electric Low Voltage Conduit. |
118 | Conduit LV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 106 | Electric Low Voltage Conduit | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Line_Wire_Aerial_Support |
Description | Lines used to represent aerial supports in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Aerial Support. |
123 | Spanguy | An Wire Aerial Span guy is a linear structure used to "Pull a vertical structure". Typically used when a down guy cannot directly be used. |
125 | Aerial Span | A feature used to represent Span between two poles that can be used in finding paths for cables. |
128 | Guy Wire |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 103 | Wire Aerial Support | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Line_Wire_Trench |
Description | Lines used to represent trenches in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Wire Trench. |
101 | Trench | An Wire Trench structure represents an open linear pit that will have direct buried conductor place in it. Typically used during construction phase of facilities. |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 104 | Wire Trench | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | BooleanSymbolValue |
Description | Valid values are Yes and No. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Yes | |
0 | No |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Cabinet_Material |
Description | List of valid cabinet materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Stainless Steel | |
4 | Fiberglass | |
6 | Steel | |
10 | Plastic | |
15 | Nickel | |
16 | Brushed Nickel | |
17 | Brushed Stainless Steel | |
18 | Coated Steel | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 101 | Wire Cabinet | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Communications_Tower_Height_Metric |
Description | Height of Tower |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
10 | 5000 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Busbar_Material |
Description | List of valid Busbar Common Conductor Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
401 | Solid Aluminium | |
402 | Solid Copper | |
403 | Solid Steel |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricLine | 8 | Medium Voltage Busbar | commonconductortype |
main.ElectricLine | 8 | Medium Voltage Busbar | conductormaterial |
main.ElectricEdgeObject | 104 | Busbar | conductormaterial |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Combined_Designtypes |
Description | All coded values for the designtype field |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 41 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bridged | |
2 | Burndy | |
3 | Bussman | |
4 | Cooper Elf | |
5 | D & W | |
6 | EJO-1 | |
7 | Fault Tamer | |
8 | Kearney | |
9 | Kearney 200 | |
10 | Kearney QA | |
11 | RTE B | |
12 | S & C | |
13 | S & C SM-4 | |
14 | X-Limiter | |
15 | NX | |
16 | CL | |
17 | Kearney A | |
18 | Kearney V | |
101 | Series Capacitor | |
102 | Series Reactor | |
103 | Shunt or Parallel Capacitor | |
104 | Shunt or Parallel Reactor | |
105 | Static VAR Compensator | |
201 | Bound | |
202 | Mesh | |
203 | Rod | |
301 | Normal Recloser | |
302 | Remove Block | |
401 | Fixed | |
402 | Voltage | |
403 | Swing | |
501 | Brace | |
502 | Suspension | |
503 | Line Post | |
601 | Induction | |
602 | Synchronous | |
701 | Cobra Head | |
702 | Security | |
703 | Roadway | |
704 | Flood |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | designtype | ||
main.ElectricJunctionObject | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Combined_Maximum_Voltage |
Description | Combined Maximum Voltage Values |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 28 |
# of Assignments | 8 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
229 | 229 V | |
240 | 240 V | |
253 | 253 V | |
264 | 264 V | |
440 | 440 V | |
480 | 480 V | |
528 | 528 V | |
660 | 660 V | |
759 | 759 V | |
1100 | 1.1 kV | |
8000 | 8 kV | |
15000 | 15 kV | |
25000 | 25 kV | |
35000 | 35 kV | |
52000 | 52 kV | |
72500 | 72.5 kV | |
120000 | 120 kV | |
145000 | 145 kV | |
170000 | 170 kV | |
240000 | 240 kV | |
300000 | 300 kV | |
362000 | 362 kV | |
420000 | 420 kV | |
550000 | 550 kV | |
800000 | 800 kV | |
1100000 | 1.1 MV | |
1200000 | 1.2 MV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | maxvoltage | ||
main.ElectricEdgeObject | 101 | Aerial Bare | maxvoltage |
main.ElectricEdgeObject | 102 | Aerial Covered | maxvoltage |
main.ElectricEdgeObject | 104 | Busbar | maxvoltage |
main.ElectricEdgeObject | 105 | Underground | maxvoltage |
main.ElectricEdgeObject | 106 | Neutral | maxvoltage |
main.ElectricEdgeObject | 108 | Submarine | maxvoltage |
main.ElectricEdgeObject | 109 | Connector | maxvoltage |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Neutral_Material |
Description | List of valid neutral materials for the distribution system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 10 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
506 | Steel | |
515 | Aluminum | |
516 | All Aluminum Conductor | |
517 | All Aluminum Steel Reinforced | |
525 | Copper | |
526 | Hard Drawn Copper | |
527 | Soft Drawn Copper | |
528 | Stranded Copper | |
529 | Copper Weld |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Combined_Nominal_Voltage_LG |
Description | Combined Line to Ground Nominal Voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 15 |
# of Assignments | 19 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
120 | 120 V | |
230 | 230 V | |
277 | 277 V | |
400 | 400 V | |
2400 | 2.4 kV | |
4800 | 4.8 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
12000 | 12 kV | |
13200 | 13.2 kV | |
14400 | 14.4 kV | |
19920 | 19.92 kV |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Combined_Nominal_Voltage_LL |
Description | Combined Line to Line Nominal Voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 83 |
# of Assignments | 19 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
208 | 208 V | |
240 | 240 V | |
253 | 253 V | |
400 | 400 V | |
480 | 480 V | |
528 | 528 V | |
600 | 600 V | |
690 | 690 V | |
1000 | 1000 V | |
2400 | 2.4 kV | |
4160 | 4.16 kV | |
4800 | 4.8 kV | |
6900 | 6.9 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
8320 | 8.32 kV | |
11000 | 11 kV | |
12000 | 12 kV | |
12470 | 12.47 kV | |
13200 | 13.2 kV | |
13800 | 13.8 kV | |
14400 | 14.4 kV | |
15000 | 15 kV | |
18000 | 18 kV | |
19920 | 19.92 kV | |
20780 | 20.78 kV | |
22860 | 22.86 kV | |
23000 | 23 kV | |
24940 | 24.94 kV | |
34500 | 34.5 kV | |
46000 | 46 kV | |
50000 | 50 kV | |
60000 | 60 kV | |
69000 | 69 kV | |
70000 | 70 kV | |
75000 | 75 kV | |
80000 | 80 kV | |
100000 | 100 kV | |
115000 | 115 kV | |
120000 | 120 kV | |
138000 | 138 kV | |
145000 | 145 kV | |
150000 | 150 kV | |
161000 | 161 kV | |
180000 | 180 kV | |
200000 | 200 kV | |
230000 | 230 kV | |
250000 | 250 kV | |
266000 | 266 kV | |
270000 | 270 kV | |
285000 | 285 kV | |
320000 | 320 kV | |
345000 | 345 kV | |
350000 | 350 kV | |
362000 | 362 kV | |
400000 | 400 kV | |
440000 | 440 kV | |
500000 | 500 kV | |
515000 | 515 kV | |
525000 | 525 kV | |
533000 | 533 kV | |
600000 | 600 kV | |
765000 | 765 kV | |
800000 | 800 kV | |
1000000 | 1 MV | |
1100000 | 1.1 MV | |
1200000 | 1.2 MV | |
1400000 | 1.4 MV | |
1500000 | 1.5 MV | |
1800000 | 1.8 MV | |
2500000 | 2.5 MV | |
3000000 | 3 MV | |
4000000 | 4 MV | |
5000000 | 5 MV | |
6000000 | 6 MV | |
6400000 | 6.4 MV | |
7200000 | 7.2 MV | |
8000000 | 8 MV | |
10000000 | 10 MV | |
12000000 | 12 MV |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Configuration_Type |
Description | How equiment is configuration, in Series or Shunt |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Shunt | |
2 | Series |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Device_OperatingMechanism |
Description | Valid combinationsfor Operating Mechanism |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 13 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bell Crank | |
2 | Control Rod | |
4 | Hook stick | |
5 | Bell Crank and Hook Stick | |
6 | Control Rod and Hook Stick | |
8 | Remote | |
9 | Bell Crank and Remote | |
10 | Control Rod and Remote | |
12 | Hook Stick and Remote | |
13 | Bell Crank, Hook Stick and Remote | |
14 | Control Rod, Hook Stick and Remote |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Device_Operation |
Description | Valid values for Operation Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 14 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Gang Operated | |
2 | Phase Operable | |
3 | Gang and Phase Operable |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Fuel_Type |
Description | Generator Fuel Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Ethenaol | |
2 | Gasoline | |
3 | Hydrogen | |
4 | Natural Gas | |
5 | Hydro |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ground_Configuration_Transformer_Regulator |
Description | Grounding type for transformers and regulators |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 6 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Grounded Wye | |
2 | Wye | |
3 | Delta | |
4 | Direct Current |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | grounding | ||
main.ElectricDevice | secondarygrounding | ||
main.ElectricDevice | 11 | High Voltage Transformer | secondarygrounding |
main.ElectricDevice | 38 | Transformer | secondarygrounding |
main.ElectricJunctionObject | grounding | ||
main.ElectricJunctionObject | secondarygrounding |
Key | Value |
---|---|
Owner | |
Domain Name | ELectric_High_Voltage_Maximumm_Operating_Voltage_LL |
Description | List of High Voltage maximum voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
100000 | 100 kV | |
121000 | 121 kV | |
124000 | 124 kV | |
145000 | 145 kV | |
172000 | 172 kV | |
245000 | 245 kV | |
420000 | 420 kV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricEdgeObject | maxoperatingvoltage |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Number_of_Phases |
Description | List of valid phase identifiers for the transmission system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | Two Phase | |
3 | Three Phase | |
6 | Six Phase |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 11 | High Voltage Transformer | numphasesconstructed |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Phase_Attribution |
Description | List of valid phase identifiers for the transmission system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | III | |
2 | II | |
3 | II,III | |
4 | I | |
5 | I,III | |
6 | I,II | |
7 | I,II,III |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 11 | High Voltage Transformer | phasechange |
main.ElectricDevice | 11 | High Voltage Transformer | phasesenergized |
main.ElectricDevice | 11 | High Voltage Transformer | phasesnormal |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Pole_Height |
Description | Height of Pole |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet | |
100 | 100 Feet | |
105 | 105 Feet | |
110 | 110 Feet | |
115 | 115 Feet | |
120 | 120 Feet | |
125 | 125 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | height |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_High_Voltage_Transformer_VA |
Description | List of valid High Voltage Transformer Power Rating |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 25 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
5500000 | 5.5 MVA | |
10000000 | 10 MVA | |
20000000 | 20 MVA | |
30000000 | 30 MVA | |
35000000 | 35 MVA | |
40000000 | 40 MVA | |
50000000 | 50 MVA | |
55000000 | 55 MVA | |
60000000 | 60 MVA | |
74000000 | 74 MVA | |
75000000 | 75 MVA | |
100000000 | 100 MVA | |
150000000 | 150 MVA | |
200000000 | 200 MVA | |
300000000 | 300 MVA | |
350000000 | 350 MVA | |
400000000 | 400 MVA | |
500000000 | 500 MVA | |
550000000 | 550 MVA | |
650000000 | 650 MVA | |
750000000 | 750 MVA | |
1000000000 | 1000 MVA | |
1200000000 | 1200 MVA | |
1500000000 | 1500 MVA |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 11 | High Voltage Transformer | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Light_Housing_Type |
Description | Light Housing Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Cobra Head | |
2 | Security | |
3 | Roadway | |
4 | Flood |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 16 | Low Voltage Lighting | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Nominal_Voltage_LG |
Description | Low Voltage Line to Ground Nominal Operating Voltage |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
120 | 120 V | |
125 | 125 V | |
230 | 230 V | |
277 | 277 V | |
400 | 400 V |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Fuse_Continuous_Amps |
Description | List of valid continuous amps for a fuse |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 21 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
3 | 3 A | |
7 | 7 A | |
10 | 10 A | |
15 | 15 A | |
20 | 20 A | |
25 | 25 A | |
30 | 30 A | |
40 | 40 A | |
50 | 50 A | |
100 | 100 A | |
200 | 200 A | |
45 | 45 A | |
60 | 60 A | |
125 | 125 A | |
225 | 225 A | |
300 | 300 A | |
320 | 320 A | |
800 | 800 A | |
1200 | 1200 A | |
2500 | 2500 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 14 | Low Voltage Fuse | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Fuse_Link_Type |
Description | Types of fuse links |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
10 | K | |
11 | T | |
12 | MS | |
13 | QH | |
14 | Standard | |
15 | SloFast |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Fuse_Type |
Description | List of valid fuse types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
17 | Kearney A | |
18 | Kearney B |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 14 | Low Voltage Fuse | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | ELectric_Low_Voltage_Maximumm_Operating_Voltage_LL |
Description | List of Low Voltage maximum voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
600 | 600 V |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Maximum_Voltage |
Description | Low Voltage maximum voltage |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
229 | 229 V | |
253 | 253 V | |
264 | 264 V | |
440 | 440 V | |
528 | 528 V | |
660 | 660 V | |
759 | 759 V | |
1100 | 1.1 kV | |
480 | 480 V | |
240 | 240 V |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Nominal_Voltage |
Description | Low Voltage Line to Line Nominal Operating Voltage |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
208 | 208 V | |
240 | 240 V | |
480 | 480 V | |
600 | 600 V | |
400 | 400 V | |
216 | 216 V | |
12 | 12 V | |
24 | 24 V | |
48 | 48 V | |
96 | 96 V |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Manufacturer |
Description | All Electric Structure Manufacturer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 50 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Appalachee | |
2 | Atlantic Wood Treatment | |
3 | Baldwin | |
4 | Baxco | |
5 | Bell Co | |
6 | Bell Timber | |
7 | Brown | |
8 | Cahaba | |
9 | Carsonite | |
10 | CDR | |
11 | Chance Foundations | |
12 | Crown Zellerbach | |
13 | CTC | |
14 | ECB Abbert Inc | |
15 | ECP Utility | |
16 | Escambia | |
17 | Fiber Tech | |
18 | Flight Light | |
19 | Georgia Pacific | |
20 | Gulf Creosote | |
21 | Gulf States | |
22 | Hot Box | |
23 | Howard Industries | |
24 | Huxford | |
25 | International Paper | |
26 | Jensen Precast | |
27 | Josyln | |
28 | Koppers | |
29 | Lakeshore Electric | |
30 | MacLean | |
31 | Midwestern Electric | |
32 | Milbank Electric | |
33 | Miller | |
34 | Osmose | |
35 | P&R Tech | |
36 | PenCell | |
37 | Quazite | |
38 | Republic | |
39 | Schweitzer | |
40 | Seaman Timber | |
41 | Shea Concrete | |
42 | Sherman Concrete | |
43 | Stallworth | |
44 | Swift | |
45 | Thomas Net | |
46 | Utility Concrete | |
47 | Weyerhaeuser | |
48 | William Frick & Company | |
9999 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Pole_Height |
Description | Low Voltage Pole Heights |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
20 | 20 Feet | |
25 | 25 Feet | |
30 | 30 Feet | |
35 | 35 Feet | |
40 | 40 Feet | |
45 | 45 Feet | |
50 | 50 Feet | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 122 | Electric Low Voltage Pole | height |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Street_Bulb_Type |
Description | List of valid bulb types for streetlights |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
30 | High Pressure Sodium (HPS) | |
31 | Low Pressure Sodium (LPS) | |
32 | Metal Halide (MH) | |
33 | Mercury Vapor (MV) | |
34 | Halogen (HG) | |
35 | Light Emitting Diode (LED) | |
36 | Phosphor-Converted Amber LED (PCA) | |
37 | Narrow-Band Amber LED (NBA) |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_Diameter_in |
Description | Wire diameter AWG size, stored as inches |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 22 |
# of Assignments | 27 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.0641 | 14 | |
0.072 | 13 | |
0.0808 | 12 | |
0.0907 | 11 | |
0.1019 | 10 | |
0.1144 | 9 | |
0.1285 | 8 | |
0.1443 | 7 | |
0.162 | 6 | |
0.1819 | 5 | |
0.2043 | 4 | |
0.2294 | 3 | |
0.2576 | 2 | |
0.2893 | 1 | |
0.3249 | 0 | |
0.3648 | 00 | |
0.4096 | 000 | |
0.46 | 0000 | |
0.666 | 366 | |
0.792 | 477 | |
0.811 | 500 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Low_Voltage_Transformer_VA |
Description | Low Voltage Transformer kVA |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
500 | 0.5 kVA | |
750 | 0.75 kVA | |
1000 | 1 kVA | |
1500 | 1.5 kVA | |
2000 | 2 kVA | |
3000 | 3 kVA | |
5000 | 5 kVA | |
7500 | 7.5 kVA | |
10000 | 10 kVA | |
15000 | 15 kVA | |
25000 | 25 kVA |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 15 | Low Voltage Generation | ratedpower |
main.ElectricDevice | 18 | Low Voltage Motor | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Marker_Type |
Description | Valid Marker Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Buried | |
2 | Overhead Ball | |
3 | Lighted Overhead Ball | |
4 | Low Line | |
5 | Water Crossing |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | indicatortypefield |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Low_Voltage_Number_Of_Phases |
Description | Low Voltage number of phases constructed |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 50 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Single Phase | |
2 | Two Phase | |
3 | Three Phase |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Nominal_Voltage_LG |
Description | Medium Voltage Line to Ground Nominal Operating Voltage |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 28 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2400 | 2.4 kV | |
4800 | 4.8 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
12000 | 12 kV | |
13200 | 13.2 kV | |
14400 | 14.4 kV | |
19920 | 19.92 kV |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Fuse_Link_Type |
Description | Types of fuse links |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
10 | K | |
11 | T | |
12 | MS | |
13 | QH | |
14 | Standard | |
15 | SloFast |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Fuse_Rating |
Description | List of valid Electric Medium Voltage Fuse Ratingsl |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | C | |
2 | E | |
3 | R | |
4 | PT |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 29 | Fuse | designtype |
main.ElectricJunctionObject | 29 | Fuse | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_KVAR |
Description | Domain of valid kVAR ratings for Medium Voltage Capacitors |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 20 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
5000 | 5 kvar | |
10000 | 10 kvar | |
20000 | 20 kvar | |
30000 | 30 kvar | |
50000 | 50 kvar | |
100000 | 100 kvar | |
150000 | 150 kvar | |
200000 | 200 kvar | |
300000 | 300 kvar | |
400000 | 400 kvar | |
500000 | 500 kvar | |
600000 | 600 kvar | |
800000 | 800 kvar | |
1200000 | 1200 kvar | |
1500000 | 1500 kvar | |
1800000 | 1800 kvar | |
2400000 | 2400 kvar | |
3600000 | 3600 kvar | |
900000 | 900 kvar |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 34 | Capacitor | ratedpower |
main.ElectricJunctionObject | 34 | Capacitor | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | ELectric_Medium_Voltage_Maximumm_Operating_Voltage_LL |
Description | List of Medium Voltage maximum voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1200 | 1.2 kV | |
7200 | 7.2 kV | |
12000 | 12 kV | |
24000 | 24 kV | |
28000 | 28 kV | |
36000 | 36 kV | |
44000 | 44 kV | |
64000 | 64 kV | |
72500 | 72.5 kV | |
96000 | 96 kV |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Maximum_Continuous_Current |
Description | Medium Voltage maximum continuous current |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
250 | 250 A | |
300 | 300 A | |
350 | 350 A | |
400 | 400 A | |
450 | 450 A | |
900 | 900 A | |
1350 | 1350 A |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Nominal_Voltage |
Description | List of valid nominal voltages for the distribution system |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 23 |
# of Assignments | 28 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2400 | 2.4 kV | |
4160 | 4.16 kV | |
4800 | 4.8 kV | |
6900 | 6.9 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
8320 | 8.32 kV | |
12000 | 12 kV | |
12470 | 12.47 kV | |
13200 | 13.2 kV | |
13800 | 13.8 kV | |
14400 | 14.4 kV | |
19920 | 19.92 kV | |
20780 | 20.78 kV | |
22860 | 22.86 kV | |
23000 | 23 kV | |
24940 | 24.94 kV | |
34500 | 34.5 kV | |
46000 | 46 kV | |
69000 | 69 kV |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Phase_Attribution |
Description | List of valid phase identifiers for the distribution system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 99 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | C | |
2 | B | |
3 | BC | |
4 | A | |
5 | AC | |
6 | AB | |
7 | ABC |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Pole_Height |
Description | Medium Voltage Pole height |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
35 | 35 Feet | |
40 | 40 Feet | |
45 | 45 Feet | |
50 | 50 Feet | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 121 | Electric Medium Voltage Pole | height |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Recloser_Continuous_Amps |
Description | Medium Voltage Recloser Continuous Amps Ratings |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
100 | 100 A | |
200 | 200 A | |
280 | 280 A | |
400 | 400 A | |
560 | 560 A | |
600 | 600 A | |
630 | 630 A |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 41 | Recloser | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_XFR_Type |
Description | Transformer Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Dry | |
2 | Oil Filled | |
3 | Pumped Oil | |
4 | Air Cooled |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Regulator_VA |
Description | Medium Voltage Regulator VA |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 81 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
25000 | 25 kVA | |
38000 | 38 kVA | |
38100 | 38.1 kVA | |
50000 | 50 kVA | |
57000 | 57 kVA | |
57200 | 57.2 kVA | |
69000 | 69 kVA | |
72000 | 72 kVA | |
75000 | 75 kVA | |
76000 | 76 kVA | |
76200 | 76.2 kVA | |
100000 | 100 kVA | |
114000 | 114 kVA | |
114300 | 114.3 kVA | |
124800 | 124.8 kVA | |
138000 | 138 kVA | |
144000 | 144 kVA | |
150000 | 150 kVA | |
152000 | 152 kVA | |
167000 | 167 kVA | |
171600 | 171.6 kVA | |
172500 | 172.5 kVA | |
200000 | 200 kVA | |
207000 | 207 kVA | |
216000 | 216 kVA | |
219000 | 219 kVA | |
228600 | 228.6 kVA | |
250000 | 250 kVA | |
276000 | 276 kVA | |
288000 | 288 kVA | |
300000 | 300 kVA | |
332000 | 332 kVA | |
333000 | 333 kVA | |
342900 | 342.9 kVA | |
345000 | 345 kVA | |
400000 | 400 kVA | |
414000 | 414 kVA | |
416000 | 416 kVA | |
432000 | 432 kVA | |
456000 | 456 kVA | |
500000 | 500 kVA | |
517500 | 517.5 kVA | |
518000 | 518 kVA | |
552000 | 552 kVA | |
576000 | 576 kVA | |
600000 | 600 kVA | |
621000 | 621 kVA | |
657000 | 657 kVA | |
667000 | 667 kVA | |
690000 | 690 kVA | |
700000 | 700 kVA | |
720000 | 720 kVA | |
750000 | 750 kVA | |
828000 | 828 kVA | |
833000 | 833 kVA | |
863000 | 863 kVA | |
864000 | 864 kVA | |
996000 | 996 kVA | |
999000 | 999 kVA | |
1000000 | 1000 kVA | |
1035000 | 1035 kVA | |
1145000 | 1145 kVA | |
1200000 | 1200 kVA | |
1242000 | 1242 kVA | |
1248000 | 1248 kVA | |
1296000 | 1296 kVA | |
1500000 | 1500 kVA | |
1554000 | 1554 kVA | |
1656000 | 1656 kVA | |
1728000 | 1728 kVA | |
2000000 | 2000 kVA | |
2001000 | 2001 kVA | |
2070000 | 2070 kVA | |
2100000 | 2100 kVA | |
2160000 | 2160 kVA | |
2499000 | 2499 kVA | |
2500000 | 2500 kVA | |
2589000 | 2589 kVA | |
3000000 | 3000 kVA | |
3462000 | 3462 kVA |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 35 | Voltage Regulator | ratedpower |
main.ElectricJunctionObject | 35 | Voltage Regulator | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Medium_Voltage_Transformer_VA |
Description | List of volt amps for devices, displayed in kilovolt |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 53 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
500 | 0.5 kVA | |
1000 | 1.0 kVA | |
1500 | 1.5 kVA | |
3000 | 3 kVA | |
5000 | 5 kVA | |
7000 | 7 kVA | |
7500 | 7.5 kVA | |
10000 | 10 kVA | |
15000 | 15 kVA | |
20000 | 20 kVA | |
25000 | 25 kVA | |
30000 | 30 kVA | |
37500 | 37.5 kVA | |
45000 | 45 kVA | |
50000 | 50 kVA | |
75000 | 75 kVA | |
100000 | 100 kVA | |
112500 | 112.5 kVA | |
150000 | 150 kVA | |
167000 | 167 kVA | |
200000 | 200 kVA | |
225000 | 225 kVA | |
250000 | 250 kVA | |
300000 | 300 kVA | |
333000 | 333 kVA | |
342000 | 342 kVA | |
375000 | 375 kVA | |
416000 | 416 kVA | |
450000 | 450 kVA | |
500000 | 500 kVA | |
666000 | 666 kVA | |
750000 | 750 kVA | |
833000 | 833 kVA | |
966000 | 966 kVA | |
1000000 | 1000 kVA | |
1250000 | 1250 kVA | |
1500000 | 1500 kVA | |
1750000 | 1750 kVA | |
2000000 | 2000 kVA | |
2500000 | 2500 kVA | |
3000000 | 3000 kVA | |
3500000 | 3500 kVA | |
3750000 | 3750 kVA | |
5000000 | 5000 kVA | |
7000000 | 7000 kVA | |
7500000 | 7500 kVA | |
10000000 | 10000 kVA | |
12000000 | 12000 kVA | |
4000000 | 4000 kVA | |
4250000 | 4250 kVA | |
4500000 | 4500 kVA | |
4750000 | 4750 kVA |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 38 | Transformer | ratedpower |
main.ElectricJunctionObject | 38 | Transformer | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Motor_Type |
Description | Motor Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Induction | |
2 | Synchronous |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 32 | Motor and Pump | designtype |
main.ElectricDevice | 18 | Low Voltage Motor | designtype |
main.ElectricJunctionObject | 32 | Motor and Pump | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Operating_Status |
Description | Switchable Device Position |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 25 |
Code | Description | Details |
---|---|---|
0 | Closed | |
1 | Open | |
2 | Open, Traceable |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_PF_Control_Type |
Description | Power Factor Control Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Current | |
2 | Manual | |
3 | Power Factor | |
4 | VAR | |
5 | Tempature | |
6 | Time | |
7 | Reactive Current |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Phase_Attribution_All |
Description | All Valid Phase Descriptions |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 51 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | C or c | |
2 | B or b | |
3 | BC or bc | |
4 | A or a | |
5 | AC or ac | |
6 | AB or ab | |
7 | ABC or abc |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Pole_Top_Configuration |
Description | Pole Top Configuratoin |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Alley Arm | |
2 | Horizonal | |
3 | Vertical | |
4 | Trident | |
5 | Inverted Trident | |
6 | Iverted Alley Arm | |
7 | Staggered |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Power_Factor_Correcting_Type |
Description | Type of Power Factor Correcting Equipment |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
101 | Series Capacitor | |
102 | Series Reactor | |
103 | Shunt or Parallel Capacitor | |
104 | Shunt or Parallel Reactor | |
105 | Static VAR Compensator |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricDevice | 34 | Capacitor | designtype |
main.ElectricJunctionObject | 34 | Capacitor | designtype |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Regulator_Operation_Type |
Description | Regulator Operation Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Fixed Tap | |
2 | Regulator Terminal | |
3 | R-X settings | |
4 | Load center |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Section_Indicator |
Description | Valid domain for Section Indicator |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Start or End of Section |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Structure_Junction_Low_Voltage_Pole_Material |
Description | List of valid Electric Low Voltage Pole Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | Carbon Fiber | |
3 | Composite | |
4 | Fiberglass | |
5 | Monofilament | |
6 | Steel | |
7 | Wood | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 122 | Electric Low Voltage Pole | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Structure_Junction_Medium_Voltage_Pole_Material |
Description | List of valid Electric Medium Voltage Pole Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2 | Carbon Fiber | |
3 | Composite | |
6 | Steel | |
7 | Wood | |
9 | Precast Concrete | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 121 | Electric Medium Voltage Pole | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Structure_Pole_Class_High_Voltage |
Description | List of valid pole classes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
101 | Class H1 | |
102 | Class H2 | |
103 | Class H3 | |
104 | Class H4 | |
105 | Class H5 | |
3 | Class 3 | |
4 | Class 4 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Structure_Pole_Class_Low_Voltage |
Description | List of valid pole classes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6 | Class 6 | |
7 | Class 7 | |
8 | Class 8 | |
9 | Class 9 | |
10 | Class 10 | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 | |
5 | Class 5 | |
101 | Class H1 | |
102 | Class H2 | |
103 | Class H3 | |
104 | Class H4 | |
105 | Class H5 | |
106 | Class H6 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 122 | Electric Low Voltage Pole | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Switch_Breaking_Medium |
Description | Switch Arc Breaking Medium |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Air | |
2 | CO2 | |
3 | Gas | |
4 | Hybrid | |
5 | Oil | |
6 | Vaccum |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Status |
Description | Valid lifecycle states for the assets. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 84 |
Code | Description | Details |
---|---|---|
0 | Out of Service | |
1 | Proposed | |
2 | In Service | |
4 | Planned Removal |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Status_Combined |
Description | Bitwise combination of lifecycle states for subnetwork management |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Out of Service | |
1 | Proposed | |
2 | In Service | |
3 | Proposed and In Service | |
4 | Planned Removal | |
6 | In Service and Planned Removal |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Foundation |
Description | Type of foundation |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Other | |
2 | Set Extra Deep In Earth | |
3 | Set Normal With Concrete Backfill | |
4 | Set Normally In Earth | |
5 | Set On Concrete Foundation |
Key | Value |
---|---|
Owner | |
Domain Name | Spatial_Source |
Description | Source of the spatial location |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | As-Built | |
2 | CAD | |
3 | Digitized | |
4 | GPS/GNSS | |
5 | Field Sketch |
Key | Value |
---|---|
Owner | |
Domain Name | VerticalAlignment |
Description | Valid symbol vertical alignment values. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Top | |
1 | Center | |
2 | Baseline | |
3 | Bottom |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Crossarm_Material |
Description | Crossarm material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | Fiberglass | |
6 | Steel | |
7 | Wood | |
20 | Other |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Duct_Diameter |
Description | Diameter of duct |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.91 | 3/4" | |
1.175 | 1" | |
1.52 | 1 1/4" | |
1.76 | 1 1/2" | |
2.235 | 2" | |
2.735 | 2 1/2" | |
3.36 | 3" | |
3.86 | 3 1/2" | |
4.32 | 4" | |
5.38 | 5" | |
6.435 | 6" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | diameter | ||
main.StructureLine | 106 | Electric Low Voltage Conduit | diameter |
main.StructureLine | 107 | Electric Medium Voltage Conduit | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Pole_Eight_metric |
Description | Metric Pole Hieght |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Pole_Height_Combined |
Description | List of valid heights for all poles |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 22 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
25 | 25 Feet | |
30 | 30 Feet | |
35 | 35 Feet | |
40 | 40 Feet | |
45 | 45 Feet | |
50 | 50 Feet | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet | |
100 | 100 Feet | |
105 | 105 Feet | |
110 | 110 Feet | |
115 | 115 Feet | |
120 | 120 Feet | |
125 | 125 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | height |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Cabinet_Equipment_Type |
Description | |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
201 | Fuse Cabinet | |
202 | Junction Cabinet | |
203 | Pad Mounted Switchgear | |
204 | Station Cabinet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 101 | Wire Cabinet | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Guy_Diameter_in |
Description | List of diameters of guys in inches |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6.35 | 1/4" | |
7.9629 | 5/16" | |
9.525 | 3/8" | |
11.1125 | 7/16" | |
12.7 | 1/2" | |
14.2875 | 9/16" | |
25.4 | 1" |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 103 | Wire Aerial Support | diameter |
main.StructureJunction | 102 | Wire Structure Guy | diameter |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Anchor_Guy_Size |
Description | List of anchor guy sizes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Anchor_Guy_Type |
Description | List of anchor guy types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
41 | Single Helix | |
42 | Double Helix | |
43 | Triple Helix | |
44 | Manta Ray | |
45 | Square | |
46 | Disk | |
47 | Rock |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 102 | Wire Structure Guy | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Guy_Material |
Description | List of valid guy materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6 | Steel |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 102 | Wire Structure Guy | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Handhole_Material |
Description | List of valid electric handhole materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Stainless Steel | |
4 | Fiberglass | |
6 | Steel | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 103 | Wire Handhole | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Handhole_Size |
Description | List of handhole sizes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Maker_Material |
Description | List of types of marker materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 9 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Stainless Steel | |
3 | Composite | |
4 | Fiberglass | |
6 | Steel | |
7 | Wood | |
8 | Poured Concrete | |
9 | Precast Concrete | |
10 | Plastic |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Manhole_Type |
Description | List of types of manholes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
61 | Deep | |
62 | Normal | |
63 | Shallow |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 110 | Wire Vault | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Pole_Class_Combined |
Description | Combined list of pole classes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 | |
5 | Class 5 | |
6 | Class 6 | |
7 | Class 7 | |
8 | Class 8 | |
9 | Class 9 | |
10 | Class 10 | |
101 | Class H1 | |
102 | Class H2 | |
103 | Class H3 | |
104 | Class H4 | |
105 | Class H5 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | equipmenttypeorclass | ||
main.StructureJunctionObject | equipmenttypeorclass | ||
main.StructureJunctionObject | 120 | Pole | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Pole_Treatment_Type |
Description | List of pole or tower treatment types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Butt | |
2 | Natural | |
3 | Penta | |
4 | Creosote | |
5 | Chromated Copper Arsenates | |
6 | Chemonite | |
7 | Napthena | |
8 | Cellon | |
9 | Paint | |
10 | Copper Naphthenate | |
11 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | treatment |
main.StructureJunction | 121 | Electric Medium Voltage Pole | treatment |
main.StructureJunction | 122 | Electric Low Voltage Pole | treatment |
main.StructureJunction | 123 | Wire Support Pole | treatment |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Support_Pole_Class |
Description | List of valid pole classes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Class 1 | |
2 | Class 2 | |
3 | Class 3 | |
4 | Class 4 | |
5 | Class 5 | |
6 | Class 6 | |
7 | Class 7 | |
8 | Class 8 | |
9 | Class 9 | |
10 | Class 10 | |
101 | Class H1 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 123 | Wire Support Pole | equipmenttypeorclass |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Support_Pole_Material |
Description | List of support pole materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
4 | Fiberglass | |
6 | Steel | |
7 | Wood | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 123 | Wire Support Pole | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Vault_Material |
Description | List of vault materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
6 | Steel | |
7 | Wood | |
8 | Poured Concrete | |
9 | Precast Concrete | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 110 | Wire Vault | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Vault_Size |
Description | List of vault sizes |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Line_Trench_Material |
Description | List of valid trench materials |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
11 | Open | |
12 | Earth Covered | |
20 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureLine | 104 | Wire Trench | materialcode |
Key | Value |
---|---|
Owner | |
Domain Name | Yes_No_Simple |
Description | Valid Yes, No values without unknown |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 25 |
Code | Description | Details |
---|---|---|
0 | No | |
1 | Yes |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsSubnetworkController |
Description | Indicates if a device feature is a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 37 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierName |
Description | The tier names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 37 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Electric Distribution |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TerminalNames |
Description | The terminal names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 49 |
# of Assignments | 22 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Single Terminal | |
2 | DT:Source | |
3 | DT:Load | |
4 | T:Terminal A | |
5 | T:Terminal B | |
6 | T:Terminal C | |
7 | 2wXFR:Primary | |
8 | 2wXFR:Secondary | |
9 | V:Terminal A | |
10 | V:Terminal B | |
11 | V:Terminal C | |
12 | INV:DC Input | |
13 | INV:AC Output | |
14 | RT:AC Input | |
15 | RT:DC Output | |
16 | CB:Line Side | |
17 | CB:Bus Side | |
18 | Bypass:Regulator Source | |
19 | Bypass:Regulator Load | |
20 | Bypass:Regulator In Bushing | |
21 | Bypass:Regulator Out Bushing | |
22 | VR:In Bushing | |
23 | VR:Out Bushing | |
24 | HVDS:Bus Side | |
25 | HVDS:Line Side | |
26 | HVIS:Terminal A | |
27 | HVIS:Terminal B | |
28 | RT:Measured Power | |
29 | RT:Communications | |
30 | RT:Aux Power | |
31 | SS:S1 | |
32 | SS:S2 | |
33 | Power | |
34 | Monitor | |
35 | Communications | |
36 | 3wXFR:Primary | |
37 | 3wXFR:Secondary | |
38 | 3wXFR:Tertiary | |
39 | Line Side | |
40 | Load Side | |
41 | CBD:Line Side | |
42 | CBD:Bus Side | |
43 | 2wXFRBD:Primary | |
44 | 2wXFRBD:Secondary | |
45 | GS:Line Side | |
46 | GS:Ground Side | |
47 | TW:Core | |
48 | TW:Bushing |