Key | Value |
---|---|
Name | ElectricTransmissionEssentials_UtilityNetwork.geodatabase |
Workspace Type | Local Database |
Workspace Factory | Sqlite |
Geodatabase Release | 3.0.0 |
Date Exported | 2025-06-09 13:10:42 |
Path |
Owner | Domain Name | Description | Field Type | Domain Type | Split Policy | Merge Policy | # of Codes | # of Assignments |
---|---|---|---|---|---|---|---|---|
Asset_Type_Conductor_Details_Busbar | Asset Types for Busbar | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Asset_Type_ElectricTransmission_Assembly_High_Voltage_Bay | Bay container | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Asset_Type_ElectricTransmission_Device_High_Voltage_Generation | High Voltage Generation | Short Integer | Coded Value | Duplicate | Default Value | 11 | 1 | |
Asset_Type_ElectricTransmission_Device_High_Voltage_Section_Heads | Asset Types for High Voltage Section Heads | Short Integer | Coded Value | Duplicate | Default Value | 5 | 1 | |
Asset_Type_ElectricTransmission_Device_High_Voltage_Service | High Voltage Service | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_ElectricTransmission_Device_High_Voltage_Switch | High Voltage Switch | Short Integer | Coded Value | Duplicate | Default Value | 5 | 1 | |
Asset_Type_ElectricTransmission_Device_High_Voltage_Transformer | High Voltage Transformer | Short Integer | Coded Value | Duplicate | Default Value | 10 | 1 | |
Asset_Type_ElectricTransmission_Junction_High_Voltage_Attachment | High Voltage Attachment | Short Integer | Coded Value | Duplicate | Default Value | 7 | 1 | |
Asset_Type_ElectricTransmission_Junction_High_Voltage_Connection_Point | High Voltage Connection Point | Short Integer | Coded Value | Duplicate | Default Value | 10 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Busbar | High Voltage Busbar | Short Integer | Coded Value | Duplicate | Default Value | 4 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Connector | High Voltage Connector | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Overhead_Conductor | High Voltage Conductor | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Service | High Voltage Service Lines | Short Integer | Coded Value | Duplicate | Default Value | 7 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Submersible_Conductor | High VoltageSubmersibleConductor | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_ElectricTransmission_Line_High_Voltage_Underground_Conductor | High VoltageUndergroundConductor | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_Structure_Boundary_Electric_Substation_Boundary | The Asset Types for the Electric Distribution Asset Group Substation Boundary | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Asset_Type_Structure_Boundary_Electric_Zone | Asset Types for Electric Zones | Short Integer | Coded Value | Duplicate | Default Value | 3 | 1 | |
Asset_Type_Structure_Junction_Electric_High_Voltage_Pole | The Asset Types for the Electric Distribution Asset Group High Voltage Pole | Short Integer | Coded Value | Duplicate | Default Value | 8 | 1 | |
Asset_Type_Structure_Junction_Electric_Station | Asset Types for Electric Stations | Short Integer | Coded Value | Duplicate | Default Value | 4 | 1 | |
Asset_Type_Structure_Junction_Marker | Junctions used to represent markers in the Structure Network | Short Integer | Coded Value | Duplicate | Default Value | 7 | 1 | |
Asset_Type_Transmission_Conductor_Details_Aerial_Bare | Aerial Bare Cable | Short Integer | Coded Value | Duplicate | Default Value | 5 | 1 | |
Asset_Type_Transmission_Conductor_Details_Aerial_Covered | Asset Types for Aerial Covered Cable | Short Integer | Coded Value | Duplicate | Default Value | 4 | 1 | |
Asset_Type_Transmission_Conductor_Details_Submarine | Asset Types for Submarine | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Asset_Type_Transmission_Conductor_Details_Underground | Asset Types for Underground | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Attribute Rule Type | The attribute rule type that created the error record. | Short Integer | Coded Value | Default Value | Default Value | 3 | 4 | |
Construction_Status | Valid Construction statues for the assets | Short Integer | Coded Value | Duplicate | Default Value | 8 | 48 | |
Electric_Combined_Bank_Power_Units | Combined domain for power units | Long Integer | Coded Value | Duplicate | Default Value | 161 | 1 | |
Electric_Ground_Configuration | List of valid ground types for the distribution system | Short Integer | Coded Value | Duplicate | Default Value | 6 | 9 | |
Electric_Ground_Configuration_Transformer_Regulator | Grounding type for transformers and regulators | Short Integer | Coded Value | Duplicate | Default Value | 5 | 4 | |
Electric_Marker_Type | Valid Marker Types | Short Integer | Coded Value | Duplicate | Default Value | 6 | 1 | |
Electric_Ohms_per_KM | Range domain of valid values for Electric Cable resistance per KM | Double | Range | Duplicate | Default Value | 4 | ||
Electric_Operating_Status | Switchable Device Position | Short Integer | Coded Value | Duplicate | Default Value | 3 | 3 | |
Electric_Transmission_Phase_Attribution_All | All Valid Phase Descriptions | Short Integer | Coded Value | Duplicate | Default Value | 8 | 2 | |
Electric_Wire_Diameter_in | Wire diameter AWG size, stored as inches | Double | Coded Value | Duplicate | Default Value | 22 | 7 | |
Electric_Wire_Insulation_Type | Electric Wire Insulation Type | Short Integer | Coded Value | Duplicate | Default Value | 8 | 7 | |
Electric_Wire_kcmil | Wire kcmil sizes | Double | Range | Duplicate | Default Value | 7 | ||
ElectricTransmission_Combined_Maximum_Voltage | Combined Maximum Voltage Values | Long Integer | Coded Value | Duplicate | Default Value | 18 | 9 | |
ElectricTransmission_Combined_Maximumm_Operating_Voltage_LL | Combined list of maximum operating voltages | Long Integer | Coded Value | Duplicate | Default Value | 17 | 1 | |
ElectricTransmission_Combined_Nominal_Voltage_LG | Combined Line to Ground Nominal Voltages | Long Integer | Coded Value | Duplicate | Default Value | 11 | 4 | |
ElectricTransmission_Combined_Nominal_Voltage_LL | Combined Line to Line Nominal Voltages | Long Integer | Coded Value | Duplicate | Default Value | 75 | 15 | |
ElectricTransmission_Connector_Material | List of valid Connector Common Conductor Material | Short Integer | Coded Value | Duplicate | Default Value | 14 | 7 | |
ElectricTransmission_High_Voltage_Generation_Range | Long Integer | Range | Duplicate | Default Value | 1 | |||
ElectricTransmission_High_Voltage_Maximum_Voltage | The maximum voltage, in kV | Long Integer | Coded Value | Duplicate | Default Value | 12 | 10 | |
ELectricTransmission_High_Voltage_Maximumm_Operating_Voltage_LL | List of High Voltage maximum voltages | Long Integer | Coded Value | Duplicate | Default Value | 8 | 18 | |
ElectricTransmission_High_Voltage_Nominal_Voltage | List of valid nominal voltages for high voltage | Long Integer | Coded Value | Duplicate | Default Value | 46 | 8 | |
ElectricTransmission_High_Voltage_Phase_Attribution | List of valid phase identifiers for the transmission system | Short Integer | Coded Value | Duplicate | Default Value | 8 | 14 | |
ElectricTransmission_High_Voltage_Transformer_VA | List of valid High Voltage Transformer Power Rating | Long Integer | Coded Value | Duplicate | Default Value | 31 | 1 | |
ElectricTransmission_Section_Indicator | Valid domain for Section Indicator | Short Integer | Coded Value | Duplicate | Default Value | 1 | 5 | |
Lifecycle_Combined | Bitwise combination of lifecycle states for subnetwork management | Short Integer | Coded Value | Duplicate | Default Value | 6 | 9 | |
Lifecycle_Status | Valid lifecycle states for the assets. | Short Integer | Coded Value | Duplicate | Default Value | 4 | 39 | |
Network_6_AssociationStatus | Indicates how the feature participates in associations. | Short Integer | Coded Value | Duplicate | Default Value | 36 | 41 | |
Network_6_FeatureSourceID | The source feature class name in the utility network. | Short Integer | Coded Value | Default Value | Default Value | 16 | 0 | |
Network_6_FlowDirection | Indicates how the feature flows in network. | Short Integer | Coded Value | Duplicate | Default Value | 3 | 14 | |
Network_6_IsConnected | Indicates if the feature is connected to a subnetwork controller. | Short Integer | Coded Value | Duplicate | Default Value | 3 | 23 | |
Network_6_IsContentVisible | Indicates if the content or attachment association is visible for containment associations. | Short Integer | Coded Value | Default Value | Default Value | 2 | 0 | |
Network_6_IsDeleted | Indicates if a subnetwork has been marked for deletion. | Short Integer | Coded Value | Default Value | Default Value | 2 | 0 | |
Network_6_IsDirty | Indicates if a subnetwork is clean, dirty, or invalid. | Short Integer | Coded Value | Default Value | Default Value | 3 | 4 | |
Network_6_IsSubnetworkController | Indicates if a device feature is a subnetwork controller. | Short Integer | Coded Value | Default Value | Default Value | 2 | 9 | |
Network_6_TerminalNames | The terminal names in the utility network. | Short Integer | Coded Value | Duplicate | Default Value | 49 | 16 | |
Network_6_TierName | The tier names in the utility network. | Short Integer | Coded Value | Default Value | Default Value | 3 | 9 | |
Network_6_TierTopologyType | The type of topology for each tier. | Short Integer | Coded Value | Default Value | Default Value | 2 | 0 | |
Network_6_UnknownAssetType | The AssetType domain for the Unknown AssetGroup. | Short Integer | Coded Value | Default Value | Default Value | 1 | 11 | |
Validation Error Exception | Indicates if the error record has been marked as an exception. | Short Integer | Coded Value | Default Value | Default Value | 2 | 4 | |
Validation Error Phase | Indicates error lifecycle phase of an error | Long Integer | Coded Value | Default Value | Default Value | 3 | 4 | |
Validation Error Status | Indicates error lifecycle status of an error | Long Integer | Coded Value | Default Value | Default Value | 6 | 4 | |
Validation Status | The current record's validation status. | Short Integer | Coded Value | Default Value | Default Value | 8 | 32 | |
Wire_Attachment_Height | Height of attachment | Short Integer | Range | Duplicate | Default Value | 1 | ||
Wire_Pole_Height_Combined | List of valid heights for all poles | Short Integer | Coded Value | Duplicate | Default Value | 22 | 1 | |
Wire_Structure_Junction_Pole_Treatment_Type | List of pole or tower treatment types | Short Integer | Coded Value | Duplicate | Default Value | 12 | 1 | |
Yes_No | Valid Yes, No values | Short Integer | Coded Value | Duplicate | Default Value | 3 | 3 | |
Yes_No_Simple | Valid Yes, No values without unknown | Short Integer | Coded Value | Duplicate | Default Value | 2 | 9 |
Key | Value |
---|---|
Name | main.ElectricTransmissionAssembly |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 101 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Assembly |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {AC7C9792-0193-48F2-8A4F-034E8D5F8655} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Assembly feature class represents complex point features which contain other devices and lines. Like device features, assembly features are compact features but they differ in that assemblies contain other significant devices. Assemblies are useful to show a single symbol on the map yet model the internal features and their connections. Assemblies can contain devices, lines, and junctions. You can view the internal features of an assembly on the map or in the diagram view. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
symbolrotation | Symbol Rotation | Double | True | 0 | 0 | 8 | True | False | The angle the symbol should be rotated by |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_101_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
UUID_45 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricTransmissionAssembly_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
High Voltage Bay | 31 | A collection of equipment used in High Voltage Bay |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
High Voltage Bay | 31 | ASSETTYPE | 0 | Asset_Type_ElectricTransmission_Assembly_High_Voltage_Bay | |
High Voltage Bay | 31 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
High Voltage Bay | 31 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
High Voltage Bay | 31 | constructionstatus | 6 | Construction_Status | |
High Voltage Bay | 31 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.ElectricTransmissionDevice |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 98 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Device |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | -65 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {49BADCBE-0D3D-4A69-AB30-3D0A17323B9F} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Device feature class represents features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISSUBNETWORKCONTROLLER | Is Subnetwork Controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | An indicator that an object is a subnetwork controller in the utility network | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | An indicator that an object is connected to a subnetwork in the utility network and can be used to identify isolated objects | |
SUBNETWORKCONTROLLERNAME | Subnetwork Controller Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name of the subnetwork controller in the tier | |
TIERNAME | Tier Name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | The name of the tier to which the subnetwork belongs | |
TIERRANK | Tier Rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | The rank number assigned to the tier to which the subnetwork belongs | ||
TERMINALCONFIGURATION | Terminal Path | String | False | Default | 0 | 0 | 128 | True | True | terminal configuration used which defines the terminals and the paths between them | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | Geometry of the feature | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | Globally unique Identifier across geodatabases | ||
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature participates in | |
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature either has an attachment to or contains elements from | |
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature is contained in | |
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
normaloperatingstatus | Normal Status | Short Integer | True | Electric_Operating_Status | 0 | 0 | 2 | True | False | The normal state for a swtichable device | ||
phasesnormal | Phases Normal | Short Integer | False | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | ||
nominalvoltagelinetoline | nominalvoltagelinetoline: Nominal Voltage (L-L), Primary Nominal Voltage (L-L) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
secondaryvoltagelinetoline | secondaryvoltagelinetoline: Closing Phase Offset (Volts), Rated Current, Rated DC Voltage, Secondary Voltage (L-L), Voltage (L-L) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named Secondary line to line voltage measured in Volts | ||
secondaryvoltagelinetoground | secondaryvoltagelinetoground: Secondary Voltage (L-G), Voltage (L-G) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named Secondary line to neutral or ground measured in Voltage | ||
secondarygrounding | secondarygrounding: Grounding, Secondary Winding Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye on the Secondary Winding | ||
tertiaryvoltagelinetoline | Tertiary Voltage (L-L) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named Tertiary line to line voltage measured in Volts | ||
tertiaryvoltagelinetoground | Tertiary Voltage (L-G) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LG | 0 | 0 | 4 | True | False | The named Tertiary line to neutral or ground measured in Voltage | ||
tertiarygrounding | Tertiary Winding Grounding | Short Integer | True | Electric_Ground_Configuration_Transformer_Regulator | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye on the Tertiary winding | ||
maxvoltage | Maximum Voltage | Long Integer | True | ElectricTransmission_Combined_Maximum_Voltage | 0 | 0 | 0 | 4 | True | False | The maximum voltage the equipment can sustain | |
maxoperatingvoltage | Maximum Operating Voltage | Long Integer | True | ElectricTransmission_Combined_Maximumm_Operating_Voltage_LL | 0 | 0 | 0 | 4 | True | False | The maximum voltage the equipment can be reliable operated at | |
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
peakload | peakload: Max Active Power, Max Reactive Power, Peak Load | Long Integer | True | 0 | 0 | 4 | True | False | The maximum sustained load experienced by a power consumer | |||
ratedpower | ratedpower: AC Output Power, Light Watts, Max Interrupting Current, Rated Current, Rated Load (Watts), Rated Power, Rated Power (Watts), Rated Power kVA, Unit Rated kVA, Unit Rated kVAR | Long Integer | True | Electric_Combined_Bank_Power_Units | 0 | 0 | 4 | True | False | The Rated Power for the equipment | ||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
primarytosecondaryvectorgroup | Primary to Secondary Winding Vector Group | Short Integer | True | 0 | 0 | 2 | True | False | The IEC category used to describe the winding configurations and phase angle differences between the Primary and Secondary windings of a three phase transformer | |||
primarytotertiaryvectorygroup | Primary to Tertiary Winding Vector Group | Short Integer | True | 0 | 0 | 2 | True | False | The IEC category used to describe the winding configurations and phase angle differences between the Primary and Tertiary windings of a three phase transformer | |||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
sectionid | Section ID | String | True | 0 | 0 | 2000 | True | False | The Electrical Section this equipment is associated with | |||
TERMINALID | Section Terminal | Short Integer | True | 0 | 0 | 2 | True | False | The UN terminal used for this section | |||
isriser | Is Riser | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment also acts as a riser or dip | ||
sectionindicator | Section Start or End Indicator | Short Integer | True | ElectricTransmission_Section_Indicator | 0 | 0 | 2 | True | False | Indicates that this equipment is the start of a section | ||
istap | istap | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | |||
symbolrotation | Symbol Rotation | Double | True | 0 | 0 | 8 | True | False | The angle the symbol should be rotated by | |||
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_98_VALIDATIO | False | True | VALIDATIONSTATUS |
GDB_98_SUBNETWOR | False | True | SUBNETWORKCONTROLLERNAME |
GDB_98_SUBNETWOR_1 | False | True | SUBNETWORKNAME |
GDB_98_SUPPORTED | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_98_SUPPORTIN | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_43 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricTransmissionDevice_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
High Voltage Generation | 4 | A generation facility, such as a group or a single turbine, used in the generation of high volume watts. |
High Voltage Service | 9 | A service location or load point used in the delivery of high voltage power, frequently thought of as a meter location. |
High Voltage Switch | 10 | A switch used to control the flow of energy. |
Power Transformer | 11 | Transformer devices represent a single electrical transformer. These devices can be by phase or polyphase. |
High Voltage Section Head | 12 |
Key | Value |
---|---|
ID | 20 |
Minimum Client Version | 12.7 |
Evaluation Order | 1 |
Name | Stacked Points |
Description | Stacked points are not allowed in a Utility Network and need to be corrected. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 363 |
Error Message | Point intersects another point |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:41 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "featurestocompare", "main.ElectricTransmissionJunction", "comparefilters", "", "attributecomparison", "", "spatialrelation", "intersects", "customrelation", "", "tolerance", "0", "unit", "kilometer", "invertRelation", false, "ReviewerRuleType", "3", "primaryissecondary", false ] } |
Script |
|
Key | Value |
---|---|
ID | 21 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:42 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 22 |
Minimum Client Version | 13.0 |
Evaluation Order | 3 |
Name | Invalid Geometry |
Description | All features need to have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = ), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:42 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 23 |
Minimum Client Version | 12.7 |
Evaluation Order | 4 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:42 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 24 |
Minimum Client Version | 12.5 |
Evaluation Order | 5 |
Name | Unknown Subtype |
Description | A device exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:42 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
ID | 25 |
Minimum Client Version | 12.7 |
Evaluation Order | 6 |
Name | Stacked Devices and Junctions |
Description | Features in the device layer are stacked on features from the junction layer. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 363 |
Error Message | Point intersects another point |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:42 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "featurestocompare", "main.ElectricTransmissionDevice", "comparefilters", "", "attributecomparison", "", "spatialrelation", "intersects", "customrelation", "", "tolerance", "0", "unit", "", "invertRelation", false, "ReviewerRuleType", "3", "primaryissecondary", true ] } |
Script |
|
Key | Value |
---|---|
Name | main.ElectricTransmissionEdgeObject |
Dataset Type | Table |
Dataset ID | 105 |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {E09FBE46-E98C-41B2-ACC5-4CC288FEC833} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Details | The Edge Object class represents non-spatial linear features. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
lifecyclestatus | Lifecycle Status | Short Integer | True | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | True | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
assetid | Asset ID | String | True | 0 | 0 | 2000 | True | False | The Asset ID or Facilit ID of the equipment |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_105_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_105_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_105_SUBNETWO | False | True | SUBNETWORKNAME |
UUID_49 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionEdgeObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | ISCONNECTED | 2 | Network_6_IsConnected | |
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
Unknown | 0 | SUPPORTINGSUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.ElectricTransmissionJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 102 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Junction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {BA8378F9-B5B0-4927-B6D2-822740E023AA} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Junction class represents locations where lines connect to lines or lines connect to devices. A key use for junction features is to allow devices or lines to connect to another line at an intermediate vertex. You can think of a junction as 'glue point' at key places to connect all the features of a utility network. Junctions can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
phasesnormal | Phases Normal | Short Integer | False | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
isriser | Is Riser | Short Integer | True | Yes_No_Simple | 0 | 0 | 2 | True | False | Indicates that this equipment also acts as a riser or dip | ||
sectionid | Section ID | String | True | 0 | 0 | 2000 | True | False | The Electrical Section this equipment is associated with | |||
symbolrotation | Symbol Rotation | Double | True | 0 | 0 | 8 | True | False | The angle the symbol should be rotated by | |||
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_102_VALIDATI | False | True | VALIDATIONSTATUS |
GDB_102_SUBNETWO | False | True | SUBNETWORKNAME |
GDB_102_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_102_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_46 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricTransmissionJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
High Voltage Attachment | 1 | Points on High voltage lines where structures would attach. |
High Voltage Connection Point | 2 | Points where electric cables connect, but no device exists, like a Tap. |
Key | Value |
---|---|
ID | 26 |
Minimum Client Version | 13.0 |
Evaluation Order | 1 |
Name | Invalid Geometry |
Description | All features need to have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = ), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:45 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 27 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Stacked Points |
Description | Stacked points are not allowed in a Utility Network and need to be corrected. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 363 |
Error Message | Point intersects another point |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:46 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "featurestocompare", "main.ElectricTransmissionDevice", "comparefilters", "", "attributecomparison", "", "spatialrelation", "intersects", "customrelation", "", "tolerance", "0", "unit", "kilometer", "invertRelation", false, "ReviewerRuleType", "3", "primaryissecondary", false ] } |
Script |
|
Key | Value |
---|---|
ID | 28 |
Minimum Client Version | 12.7 |
Evaluation Order | 3 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:46 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 29 |
Minimum Client Version | 12.7 |
Evaluation Order | 4 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:46 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 30 |
Minimum Client Version | 12.5 |
Evaluation Order | 5 |
Name | Unknown Subtype |
Description | A junction exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:46 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
Name | main.ElectricTransmissionJunctionObject |
Dataset Type | Table |
Dataset ID | 104 |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {CC1240A4-2F24-4FF7-8A7D-335C16C0F2F8} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Details | The Junction Object class represents non-spatial equipment and objects. The wire data is also modeled as junction objects to reduce the system junctions when these objects are only contained. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISSUBNETWORKCONTROLLER | Is Subnetwork Controller | Short Integer | False | Network_6_IsSubnetworkController | 0 | 0 | 0 | 2 | False | True | An indicator that an object is a subnetwork controller in the utility network | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | An indicator that an object is connected to a subnetwork in the utility network and can be used to identify isolated objects | |
SUBNETWORKCONTROLLERNAME | Subnetwork Controller Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | The unique name of the subnetwork controller in the tier | |
TIERNAME | Tier Name | Short Integer | False | Network_6_TierName | 0 | 0 | 0 | 2 | False | True | The name of the tier to which the subnetwork belongs | |
TIERRANK | Tier Rank | Long Integer | False | 0 | 0 | 0 | 4 | False | True | The rank number assigned to the tier to which the subnetwork belongs | ||
TERMINALCONFIGURATION | Terminal Path | String | False | Default | 0 | 0 | 128 | True | True | terminal configuration used which defines the terminals and the paths between them | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | Globally unique Identifier across geodatabases | ||
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature participates in | |
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature either has an attachment to or contains elements from | |
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | a list of subnetwork names that the feature is contained in | |
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Status | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_104_VALIDATI | False | True | VALIDATIONSTATUS |
GDB_104_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
GDB_104_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_104_SUBNETWO_1 | False | True | SUBNETWORKNAME |
GDB_104_SUBNETWO | False | True | SUBNETWORKCONTROLLERNAME |
UUID_48 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionJunctionObject class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | ISSUBNETWORKCONTROLLER | 0 | Network_6_IsSubnetworkController | |
Unknown | 0 | ISCONNECTED | 2 | Network_6_IsConnected | |
Unknown | 0 | SUBNETWORKCONTROLLERNAME | Unknown | ||
Unknown | 0 | TIERNAME | 0 | Network_6_TierName | |
Unknown | 0 | TIERRANK | 0 | ||
Unknown | 0 | TERMINALCONFIGURATION | Default | ||
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | SUPPORTEDSUBNETWORKNAME | Unknown | ||
Unknown | 0 | SUPPORTINGSUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
Unknown | 0 | VALIDATIONSTATUS | 6 | Validation Status |
Key | Value |
---|---|
ID | 31 |
Minimum Client Version | 12.7 |
Evaluation Order | 1 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:47 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 32 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:48 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 33 |
Minimum Client Version | 12.5 |
Evaluation Order | 3 |
Name | Unknown Subtype |
Description | A junction object exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:48 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
Name | main.ElectricTransmissionLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 100 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | -65.00010000000475 |
Z-Max | 0.0004000000044470653 |
M-Min | 0 |
M-Max | 371 |
Catalog ID | {AE7DA5E8-C129-4ACF-9C11-17038D55D022} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within assemblies. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
ISCONNECTED | Is Connected | Short Integer | False | Network_6_IsConnected | 2 | 0 | 0 | 2 | False | True | ||
FROMDEVICETERMINAL | From Device Terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | ||
TODEVICETERMINAL | To Device Terminal | Short Integer | False | Network_6_TerminalNames | 0 | 0 | 0 | 2 | True | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
phasesnormal | Phases Normal | Short Integer | False | 0 | 0 | 0 | 2 | True | False | The phases resulting from Normal switching states | ||
maxvoltage | Maximum Voltage | Long Integer | True | ElectricTransmission_Combined_Maximum_Voltage | 0 | 0 | 0 | 4 | True | False | The maximum voltage the equipment can sustain | |
maxoperatingvoltage | Maximum Operating Voltage | Long Integer | True | ELectricTransmission_High_Voltage_Maximumm_Operating_Voltage_LL | 0 | 0 | 0 | 4 | True | False | The maximum voltage the equipment can be reliable operated at | |
nominalvoltagelinetoline | Nominal Voltage (L-L) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | The named line to line voltage measured in Volts | ||
grounding | Grounding | Short Integer | True | Electric_Ground_Configuration | 0 | 0 | 2 | True | False | Attribute to define the AC system grounding type of Delta or Wye | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | The actual length of the cable, duct, conduit, trench | |||
ohm | Ohm Per Length | Double | True | 0 | 0 | 8 | True | False | The electrical resistance measured in ohms of the cable | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
sectionid | Section ID | String | True | 0 | 0 | 2000 | True | False | The Electrical Section this equipment is associated with | |||
transmissionlinename | transmissionlinename | String | True | 0 | 0 | 2000 | True | False | ||||
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True | |
st_length(SHAPE) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_100_VALIDATI | False | True | VALIDATIONSTATUS |
GDB_100_SUBNETWO | False | True | SUBNETWORKNAME |
GDB_100_SUPPORTE | False | True | SUPPORTEDSUBNETWORKNAME |
GDB_100_SUPPORTI | False | True | SUPPORTINGSUBNETWORKNAME |
UUID_44 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__ElectricTransmissionLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the ElectricTransmissionLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
High Voltage Overhead Conductor | 2 | Overhead High Voltage lines represent Transmission and Sub transmission voltage cables and are typically polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
High Voltage Underground Conductor | 31 | Underground High Voltage lines represent Transmission and Sub transmission voltage cables and are typically polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
High Voltage Submersible Conductor | 32 | Submarine High Voltage lines represent Transmission and Sub transmission voltage cables and are typically polyphase lines that represent multiple lines per phase. Lines can be Alternating (AC) or Direct Current (DC). |
High Voltage Busbar | 1 | Busbar is solid conductor used in substations on the high voltage side of equipment. |
High Voltage Connector | 3 | A line used to connect equipment, but would not be considered trackable cable. |
High Voltage Service | 15 | A High Voltage line to provide electric service |
Key | Value |
---|---|
ID | 34 |
Minimum Client Version | 13.0 |
Evaluation Order | 1 |
Name | Invalid Geometry |
Description | Check to ensure that features have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = ), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:49 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 35 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Domain |
Description | Invalid domain values can affect feature selection |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 36 |
Minimum Client Version | 12.7 |
Evaluation Order | 3 |
Name | Invalid Subtype |
Description | Invalid subtype values can affect feature selection and display |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 37 |
Minimum Client Version | 12.5 |
Evaluation Order | 4 |
Name | Multipart |
Description | Multipart lines cannot be traced through |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 223 |
Error Message | Part Count over maximum |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "12", "evaluationgoal", "is greater than", "partcountvaluelimit", "1", "partcountupperlimit", "-1", "partcountlowerlimit", "-1" ] } |
Script |
|
Key | Value |
---|---|
ID | 38 |
Minimum Client Version | 12.5 |
Evaluation Order | 5 |
Name | Unknown Subtype |
Description | A line exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
ID | 39 |
Minimum Client Version | 12.5 |
Evaluation Order | 6 |
Name | Self Closing Polyline |
Description | Polyline closes on itself. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 2 |
Error Number | 185 |
Error Message | Line/Polyline closes itself |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "16", "searchgoal", "closed" ] } |
Script |
|
Key | Value |
---|---|
ID | 40 |
Minimum Client Version | 12.5 |
Evaluation Order | 7 |
Name | Duplicate Vertex |
Description | A duplicate vertex is within the allowable tolerance |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 181 |
Error Message | Duplicate Vertex Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:50 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "unit", "foot_us", "tolerance", "0.00328083333333333", "ReviewerRuleType", "8" ] } |
Script |
|
Key | Value |
---|---|
Name | main.ElectricTransmissionLine_TransmissionConductorDetails |
Dataset Type | RelationshipClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 107 |
Type | Simple |
Cardinality | One To Many |
Notification | None |
Is Attachment | False |
Is Attributed | False |
Origin Name | main.ElectricTransmissionLine |
Origin Primary Key | GLOBALID |
Origin Foreign Key | ElectricLineGLOBALID |
Destination Name | main.TransmissionConductorDetails |
Forward Path Label | ConductorDetails |
Backward Path Label | ElectricLine |
Minimum Client Version | 10.0 |
Editor Tracking Enabled | False |
Catalog ID | {77F80AF3-A0AF-48C3-AB60-36537405E781} |
Rule ID | Origin Subtype | Origin Min Cardinality | Origin Max Cardinality | Destination Subtype | Destination Min Cardinality | Destination Max Cardinality |
---|---|---|---|---|---|---|
1 | High Voltage Busbar | 0 | 10 | Busbar | 0 | 10 |
2 | High Voltage Overhead Conductor | 0 | 10 | Aerial Bare | 0 | 10 |
3 | High Voltage Overhead Conductor | 0 | 10 | Aerial Covered | 0 | 10 |
4 | High Voltage Service | 0 | 10 | Aerial Bare | 0 | 10 |
5 | High Voltage Service | 0 | 10 | Aerial Covered | 0 | 10 |
6 | High Voltage Service | 0 | 10 | Submarine | 0 | 10 |
7 | High Voltage Service | 0 | 10 | Underground | 0 | 10 |
8 | High Voltage Submersible Conductor | 0 | 10 | Submarine | 0 | 10 |
9 | High Voltage Underground Conductor | 0 | 10 | Underground | 0 | 10 |
Key | Value |
---|---|
Name | main.ElectricTransmissionSubnetLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 103 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Electric Transmission Subnet Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | TIERNAME |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | -65.00010000000475 |
Z-Max | 0.0004000000044470653 |
M-Min | 0 |
M-Max | 371 |
Catalog ID | {1EEC3BD9-7FC0-4881-A196-CB4A43820EC0} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | |||
SUBNETWORKNAME | Subnetwork Name | String | False | Unknown | 0 | 0 | 64 | False | True | |||
ISDIRTY | Is Dirty | Short Integer | False | Network_6_IsDirty | 1 | 0 | 0 | 2 | False | True | ||
TIERNAME | Tier Name | Short Integer | Subtype | False | 0 | 0 | 0 | 2 | False | True | ||
SUBNETWORKCONTROLLERNAMES | Subnetwork Controller Names | String | False | Unknown | 0 | 0 | 1073741822 | False | True | |||
LASTUPDATESUBNETWORK | Last Update Subnetwork | Date | True | 0 | 0 | 8 | False | True | ||||
LASTACKEXPORTSUBNETWORK | Last Ack Export Subnetwork | Date | True | 0 | 0 | 8 | False | True | ||||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
st_length(SHAPE) | Double | Length | True | 0 | 0 | 0 | False | True |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | ISDIRTY | 1 | Network_6_IsDirty | |
Unknown | 0 | SUBNETWORKCONTROLLERNAMES | Unknown | ||
Generation | 1 | SUBNETWORKNAME | Unknown | ||
Generation | 1 | ISDIRTY | 1 | Network_6_IsDirty | |
Generation | 1 | SUBNETWORKCONTROLLERNAMES | Unknown | ||
Transmission | 2 | SUBNETWORKNAME | Unknown | ||
Transmission | 2 | ISDIRTY | 1 | Network_6_IsDirty | |
Transmission | 2 | SUBNETWORKCONTROLLERNAMES | Unknown |
Key | Value |
---|---|
Name | main.GDB_ValidationLineErrors |
Dataset Type | FeatureClass |
Dataset ID | 114 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Validation Line Errors |
OID Field | ObjectID |
GlobalID Field | GlobalID |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | CREATOR |
Create Date Field | CREATIONDATE |
Editor Field | UPDATEDBY |
Edit Date Field | LASTUPDATE |
Shape Field | Shape |
Spatial Reference | GCS_WGS_1984 |
Catalog ID | {A91CA52F-976C-4B23-AF56-28C64484149F} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ObjectID | Object ID | OID | Index | False | 0 | 0 | 4 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
FeatureClassID | Feature class ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureObjectID | Feature object ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureGlobalID | Feature global ID | GUID | False | 0 | 0 | 38 | True | True | ||||
ErrorNumber | Error number | Long Integer | False | 0 | 0 | 4 | True | True | ||||
ErrorMessage | Error message | String | False | 0 | 0 | 2000 | True | True | ||||
RuleType | Rule type | Short Integer | False | Attribute Rule Type | 0 | 0 | 2 | True | True | |||
RuleName | Rule name | String | False | 0 | 0 | 64 | True | True | ||||
RuleID | Rule ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
RuleDescription | Rule description | String | True | 0 | 0 | 256 | True | True | ||||
Severity | Severity | Long Integer | True | 0 | 0 | 4 | True | True | ||||
IsException | Is exception | Short Integer | True | Validation Error Exception | 0 | 0 | 2 | True | True | |||
ErrorStatus | Error status | Long Integer | True | Validation Error Status | 1 | 0 | 0 | 4 | True | True | ||
ErrorPhase | Error phase | Long Integer | True | Validation Error Phase | 2 | 0 | 0 | 4 | True | True | ||
CorrectionNotes | Correction notes | String | True | 0 | 0 | 256 | True | True | ||||
CorrectionTechnician | Correction technician | String | True | 0 | 0 | 256 | True | True | ||||
VerificationNotes | Verification notes | String | True | 0 | 0 | 256 | True | True | ||||
VerificationTechnician | Verification technician | String | True | 0 | 0 | 256 | True | True | ||||
CREATIONDATE | Creation date | Date | Created | False | 0 | 0 | 8 | False | True | |||
CREATOR | Creator | String | Creator | False | 0 | 0 | 255 | False | True | |||
LASTUPDATE | Last update | Date | Edited | False | 0 | 0 | 8 | False | True | |||
UPDATEDBY | Updated by | String | Editor | False | 0 | 0 | 255 | False | True | The portal or dbms user that last updated the feature or object, per editor tracking | ||
Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | ||||
GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | ||||
st_length(Shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Key | Value |
---|---|
Name | main.GDB_ValidationObjectErrors |
Dataset Type | Table |
Dataset ID | 112 |
Minimum Client Version | 10.1 |
Alias | Validation Object Errors |
OID Field | ObjectID |
GlobalID Field | GlobalID |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | CREATOR |
Create Date Field | CREATIONDATE |
Editor Field | UPDATEDBY |
Edit Date Field | LASTUPDATE |
Catalog ID | {AAA3D9BE-8170-46AD-A3FE-B08E3250115A} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ObjectID | Object ID | OID | Index | False | 0 | 0 | 4 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
FeatureClassID | Feature class ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureObjectID | Feature object ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureGlobalID | Feature global ID | GUID | False | 0 | 0 | 38 | True | True | ||||
ErrorNumber | Error number | Long Integer | False | 0 | 0 | 4 | True | True | ||||
ErrorMessage | Error message | String | False | 0 | 0 | 2000 | True | True | ||||
RuleType | Rule type | Short Integer | False | Attribute Rule Type | 0 | 0 | 2 | True | True | |||
RuleName | Rule name | String | False | 0 | 0 | 64 | True | True | ||||
RuleID | Rule ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
RuleDescription | Rule description | String | True | 0 | 0 | 256 | True | True | ||||
Severity | Severity | Long Integer | True | 0 | 0 | 4 | True | True | ||||
IsException | Is exception | Short Integer | True | Validation Error Exception | 0 | 0 | 2 | True | True | |||
ErrorStatus | Error status | Long Integer | True | Validation Error Status | 1 | 0 | 0 | 4 | True | True | ||
ErrorPhase | Error phase | Long Integer | True | Validation Error Phase | 2 | 0 | 0 | 4 | True | True | ||
CorrectionNotes | Correction notes | String | True | 0 | 0 | 256 | True | True | ||||
CorrectionTechnician | Correction technician | String | True | 0 | 0 | 256 | True | True | ||||
VerificationNotes | Verification notes | String | True | 0 | 0 | 256 | True | True | ||||
VerificationTechnician | Verification technician | String | True | 0 | 0 | 256 | True | True | ||||
CREATIONDATE | Creation date | Date | Created | False | 0 | 0 | 8 | False | True | |||
CREATOR | Creator | String | Creator | False | 0 | 0 | 255 | False | True | |||
LASTUPDATE | Last update | Date | Edited | False | 0 | 0 | 8 | False | True | |||
UPDATEDBY | Updated by | String | Editor | False | 0 | 0 | 255 | False | True | The portal or dbms user that last updated the feature or object, per editor tracking | ||
GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True |
Key | Value |
---|---|
Name | main.GDB_ValidationPointErrors |
Dataset Type | FeatureClass |
Dataset ID | 113 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Validation Point Errors |
OID Field | ObjectID |
GlobalID Field | GlobalID |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | CREATOR |
Create Date Field | CREATIONDATE |
Editor Field | UPDATEDBY |
Edit Date Field | LASTUPDATE |
Shape Field | Shape |
Spatial Reference | GCS_WGS_1984 |
Catalog ID | {601F687F-18E9-4E43-BCE8-7129AD88347E} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ObjectID | Object ID | OID | Index | False | 0 | 0 | 4 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
FeatureClassID | Feature class ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureObjectID | Feature object ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureGlobalID | Feature global ID | GUID | False | 0 | 0 | 38 | True | True | ||||
ErrorNumber | Error number | Long Integer | False | 0 | 0 | 4 | True | True | ||||
ErrorMessage | Error message | String | False | 0 | 0 | 2000 | True | True | ||||
RuleType | Rule type | Short Integer | False | Attribute Rule Type | 0 | 0 | 2 | True | True | |||
RuleName | Rule name | String | False | 0 | 0 | 64 | True | True | ||||
RuleID | Rule ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
RuleDescription | Rule description | String | True | 0 | 0 | 256 | True | True | ||||
Severity | Severity | Long Integer | True | 0 | 0 | 4 | True | True | ||||
IsException | Is exception | Short Integer | True | Validation Error Exception | 0 | 0 | 2 | True | True | |||
ErrorStatus | Error status | Long Integer | True | Validation Error Status | 1 | 0 | 0 | 4 | True | True | ||
ErrorPhase | Error phase | Long Integer | True | Validation Error Phase | 2 | 0 | 0 | 4 | True | True | ||
CorrectionNotes | Correction notes | String | True | 0 | 0 | 256 | True | True | ||||
CorrectionTechnician | Correction technician | String | True | 0 | 0 | 256 | True | True | ||||
VerificationNotes | Verification notes | String | True | 0 | 0 | 256 | True | True | ||||
VerificationTechnician | Verification technician | String | True | 0 | 0 | 256 | True | True | ||||
CREATIONDATE | Creation date | Date | Created | False | 0 | 0 | 8 | False | True | |||
CREATOR | Creator | String | Creator | False | 0 | 0 | 255 | False | True | |||
LASTUPDATE | Last update | Date | Edited | False | 0 | 0 | 8 | False | True | |||
UPDATEDBY | Updated by | String | Editor | False | 0 | 0 | 255 | False | True | The portal or dbms user that last updated the feature or object, per editor tracking | ||
Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | ||||
GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True |
Key | Value |
---|---|
Name | main.GDB_ValidationPolygonErrors |
Dataset Type | FeatureClass |
Dataset ID | 115 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 10.1 |
Alias | Validation Polygon Errors |
OID Field | ObjectID |
GlobalID Field | GlobalID |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | CREATOR |
Create Date Field | CREATIONDATE |
Editor Field | UPDATEDBY |
Edit Date Field | LASTUPDATE |
Shape Field | Shape |
Spatial Reference | GCS_WGS_1984 |
Catalog ID | {BCA7906F-F3F9-4FED-85E4-3F38181D0EBF} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
ObjectID | Object ID | OID | Index | False | 0 | 0 | 4 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
FeatureClassID | Feature class ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureObjectID | Feature object ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
FeatureGlobalID | Feature global ID | GUID | False | 0 | 0 | 38 | True | True | ||||
ErrorNumber | Error number | Long Integer | False | 0 | 0 | 4 | True | True | ||||
ErrorMessage | Error message | String | False | 0 | 0 | 2000 | True | True | ||||
RuleType | Rule type | Short Integer | False | Attribute Rule Type | 0 | 0 | 2 | True | True | |||
RuleName | Rule name | String | False | 0 | 0 | 64 | True | True | ||||
RuleID | Rule ID | Long Integer | False | 0 | 0 | 4 | True | True | ||||
RuleDescription | Rule description | String | True | 0 | 0 | 256 | True | True | ||||
Severity | Severity | Long Integer | True | 0 | 0 | 4 | True | True | ||||
IsException | Is exception | Short Integer | True | Validation Error Exception | 0 | 0 | 2 | True | True | |||
ErrorStatus | Error status | Long Integer | True | Validation Error Status | 1 | 0 | 0 | 4 | True | True | ||
ErrorPhase | Error phase | Long Integer | True | Validation Error Phase | 2 | 0 | 0 | 4 | True | True | ||
CorrectionNotes | Correction notes | String | True | 0 | 0 | 256 | True | True | ||||
CorrectionTechnician | Correction technician | String | True | 0 | 0 | 256 | True | True | ||||
VerificationNotes | Verification notes | String | True | 0 | 0 | 256 | True | True | ||||
VerificationTechnician | Verification technician | String | True | 0 | 0 | 256 | True | True | ||||
CREATIONDATE | Creation date | Date | Created | False | 0 | 0 | 8 | False | True | |||
CREATOR | Creator | String | Creator | False | 0 | 0 | 255 | False | True | |||
LASTUPDATE | Last update | Date | Edited | False | 0 | 0 | 8 | False | True | |||
UPDATEDBY | Updated by | String | Editor | False | 0 | 0 | 255 | False | True | The portal or dbms user that last updated the feature or object, per editor tracking | ||
Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | ||||
GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | ||||
st_area(Shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(Shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Key | Value |
---|---|
Name | main.Network |
Dataset Type | UtilityNetwork |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 6 |
Schema Generation | 7 |
Pro Version | ArcGIS Pro 3.5.1 |
Creation Time | 2025-06-09 10:47:38 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0.0004000000044470653 |
Z-Max | 0.0004000000044470653 |
Service Territory | main.ServiceTerritory |
Domain Network Name | Domain Network Alias | Domain Network ID | Tier Definition | Subnetwork Controller Type | Creation Time |
---|---|---|---|---|---|
Structure | Structure | 1 | None | 2025-06-09 10:47:38 | |
ElectricTransmission | Electric Transmission | 2 | Partitioned | Source | 2025-06-09 10:48:06 |
Domain Network Name | Tier Group Name | Tier Name | Tier ID | Tier Rank | Tier Topology | Diagram Templates | Supports Disjoint | Subnetwork Field Name | Edit Mode in Default | Edit Mode in Version | Update Structures | Update Containers | Validate Locatability | Manage isDirty | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ElectricTransmission | Generation | 1 | 1 | Mesh | False | Without Eventing | Without Eventing | True | True | False | True | 2025-06-09 10:48:15 | |||
ElectricTransmission | Transmission | 2 | 2 | Mesh | False | Without Eventing | Without Eventing | True | True | False | True | 2025-06-09 10:48:15 |
Tier Name | Include Containers | Include Content | Include Structures | Include Barriers | Validate Locatability | Traversability Scope |
---|---|---|---|---|---|---|
Generation | True | True | True | True | False | junctionsAndEdges |
Transmission | True | True | True | True | False | junctionsAndEdges |
Tier Name | Network Attribute / Category | Operator | Value | Combine Using Or |
---|---|---|---|---|
Generation | E:Operating Status Normal | Equal | 1 | True |
Generation | E:Operating Status Normal | Equal | 2 | True |
Generation | Category | Equal | E:Transformer - Distribution Power | True |
Transmission | E:Operating Status Normal | Equal | 1 | True |
Transmission | E:Operating Status Normal | Equal | 2 | True |
Transmission | Category | Equal | E:Transformer - Distribution Power | True |
Domain Network Name | Source Name | Table | Usage Type | Source ID | # of Asset Groups | # of Asset Types |
---|---|---|---|---|---|---|
Structure | StructureJunction | main.StructureJunction | Structure Junction | 4 | 4 | 20 |
Structure | StructureBoundary | main.StructureBoundary | Structure Boundary | 6 | 3 | 10 |
Structure | StructureJunctionObject | main.StructureJunctionObject | Structure Junction Object | 7 | 1 | 1 |
Structure | StructureLine | main.StructureLine | Structure Line | 5 | 1 | 1 |
Structure | StructureEdgeObject | main.StructureEdgeObject | Structure Edge Object | 8 | 1 | 1 |
ElectricTransmission | ElectricTransmissionDevice | main.ElectricTransmissionDevice | Device | 9 | 6 | 35 |
ElectricTransmission | ElectricTransmissionAssembly | main.ElectricTransmissionAssembly | Assembly | 11 | 2 | 7 |
ElectricTransmission | ElectricTransmissionJunction | main.ElectricTransmissionJunction | Junction | 12 | 3 | 18 |
ElectricTransmission | ElectricTransmissionJunctionObject | main.ElectricTransmissionJunctionObject | Junction Object | 14 | 1 | 1 |
ElectricTransmission | ElectricTransmissionLine | main.ElectricTransmissionLine | Line | 10 | 7 | 24 |
ElectricTransmission | ElectricTransmissionSubnetLine | main.ElectricTransmissionSubnetLine | Subnet Line | 13 | 3 | 0 |
ElectricTransmission | ElectricTransmissionEdgeObject | main.ElectricTransmissionEdgeObject | Edge Object | 15 | 1 | 1 |
Source Name | Asset Group Name | Asset Group Code | # of Asset Types | Creation Time |
---|---|---|---|---|
StructureJunction | Unknown | 0 | 1 | 2025-06-09 10:47:40 |
StructureJunction | Electric Station | 135 | 4 | 2025-06-09 10:48:18 |
StructureJunction | Electric High Voltage Pole | 120 | 8 | 2025-06-09 10:48:18 |
StructureJunction | Marker | 124 | 7 | 2025-06-09 10:48:18 |
StructureBoundary | Unknown | 0 | 1 | 2025-06-09 10:47:40 |
StructureBoundary | Electric Substation Boundary | 102 | 6 | 2025-06-09 10:48:23 |
StructureBoundary | Electric Zone | 110 | 3 | 2025-06-09 10:48:23 |
StructureJunctionObject | Unknown | 0 | 1 | 2025-06-09 10:47:40 |
StructureLine | Unknown | 0 | 1 | 2025-06-09 10:47:40 |
StructureEdgeObject | Unknown | 0 | 1 | 2025-06-09 10:47:40 |
ElectricTransmissionDevice | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
ElectricTransmissionDevice | High Voltage Generation | 4 | 11 | 2025-06-09 10:48:28 |
ElectricTransmissionDevice | High Voltage Service | 9 | 3 | 2025-06-09 10:48:28 |
ElectricTransmissionDevice | High Voltage Switch | 10 | 5 | 2025-06-09 10:48:28 |
ElectricTransmissionDevice | Power Transformer | 11 | 10 | 2025-06-09 10:48:28 |
ElectricTransmissionDevice | High Voltage Section Head | 12 | 5 | 2025-06-09 10:48:28 |
ElectricTransmissionAssembly | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
ElectricTransmissionAssembly | High Voltage Bay | 31 | 6 | 2025-06-09 10:48:34 |
ElectricTransmissionJunction | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
ElectricTransmissionJunction | High Voltage Attachment | 1 | 7 | 2025-06-09 10:48:38 |
ElectricTransmissionJunction | High Voltage Connection Point | 2 | 10 | 2025-06-09 10:48:38 |
ElectricTransmissionJunctionObject | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
ElectricTransmissionLine | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
ElectricTransmissionLine | High Voltage Overhead Conductor | 2 | 3 | 2025-06-09 10:48:44 |
ElectricTransmissionLine | High Voltage Underground Conductor | 31 | 3 | 2025-06-09 10:48:44 |
ElectricTransmissionLine | High Voltage Submersible Conductor | 32 | 3 | 2025-06-09 10:48:44 |
ElectricTransmissionLine | High Voltage Busbar | 1 | 4 | 2025-06-09 10:48:44 |
ElectricTransmissionLine | High Voltage Connector | 3 | 3 | 2025-06-09 10:48:44 |
ElectricTransmissionLine | High Voltage Service | 15 | 7 | 2025-06-09 10:48:44 |
ElectricTransmissionSubnetLine | Unknown | 0 | 0 | 2025-06-09 10:48:10 |
ElectricTransmissionSubnetLine | Generation | 1 | 0 | 2025-06-09 10:48:18 |
ElectricTransmissionSubnetLine | Transmission | 2 | 0 | 2025-06-09 10:48:18 |
ElectricTransmissionEdgeObject | Unknown | 0 | 1 | 2025-06-09 10:48:10 |
Source Name | Asset Group Name | Asset Type Name | Asset Group Code | Asset Type Code | Terminal Configuration | Association Role | Delete Type | Containment Scale | Split Content | Connectivity Policy | Network Categories | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|
StructureJunction | Unknown | Unknown | 0 | 0 | 2025-06-09 10:47:40 | |||||||
StructureJunction | Electric Station | Unknown | 135 | 0 | 2025-06-09 10:48:18 | |||||||
StructureJunction | Electric Station | Distribution Substation | 135 | 82 | Container | Set To None | 10 | E:Station | 2025-06-09 10:48:18 | |||
StructureJunction | Electric Station | Transmission Substation | 135 | 83 | Container | Set To None | 10 | E:Station | 2025-06-09 10:48:18 | |||
StructureJunction | Electric Station | Subtransmission Substation | 135 | 87 | Container | Set To None | 10 | E:Station | 2025-06-09 10:48:18 | |||
StructureJunction | Electric High Voltage Pole | Unknown | 120 | 0 | 2025-06-09 10:48:18 | |||||||
StructureJunction | Electric High Voltage Pole | Single Circuit Lattice HV | 120 | 330 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | Dual Circuit Lattice HV | 120 | 331 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | Triple Circuit Lattice HV | 120 | 332 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | Quadruple Circuit Lattice HV | 120 | 333 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | Gantry HV | 120 | 334 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | H-Frame HV | 120 | 335 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Electric High Voltage Pole | Pole HV | 120 | 337 | Structure | Restricted | 2025-06-09 10:48:18 | |||||
StructureJunction | Marker | Unknown | 124 | 0 | 2025-06-09 10:48:19 | |||||||
StructureJunction | Marker | Aerial Marker | 124 | 461 | Structure | Set To None | 2025-06-09 10:48:19 | |||||
StructureJunction | Marker | Buried Cable Marker | 124 | 462 | Structure | Set To None | 2025-06-09 10:48:19 | |||||
StructureJunction | Marker | Overhead Water Crossing | 124 | 463 | Structure | Set To None | E:Cable - Overhead | 2025-06-09 10:48:19 | ||||
StructureJunction | Marker | Submerged Cable Marker | 124 | 464 | Structure | Set To None | 2025-06-09 10:48:19 | |||||
StructureJunction | Marker | Covered Marker | 124 | 465 | 2025-06-09 10:48:19 | |||||||
StructureJunction | Marker | Terrain Marker | 124 | 466 | Structure | Restricted | 2025-06-09 10:48:19 | |||||
StructureBoundary | Unknown | Unknown | 0 | 0 | 2025-06-09 10:47:40 | |||||||
StructureBoundary | Electric Substation Boundary | Unknown | 102 | 0 | 2025-06-09 10:48:23 | |||||||
StructureBoundary | Electric Substation Boundary | Distribution Substation | 102 | 82 | Container | Restricted | 2500 | E:Station | 2025-06-09 10:48:23 | |||
StructureBoundary | Electric Substation Boundary | Transmission Substation | 102 | 83 | Container | Restricted | 2500 | E:Station | 2025-06-09 10:48:23 | |||
StructureBoundary | Electric Substation Boundary | Transmission Switching Station | 102 | 84 | Container | Restricted | 2500 | E:Station | 2025-06-09 10:48:23 | |||
StructureBoundary | Electric Substation Boundary | Transmission Metering Station | 102 | 88 | Container | Restricted | 1 | E:Station | 2025-06-09 10:48:23 | |||
StructureBoundary | Electric Substation Boundary | Transmission Terminal Station | 102 | 89 | Container | Restricted | 1 | E:Station | 2025-06-09 10:48:23 | |||
StructureBoundary | Electric Zone | Unknown | 110 | 0 | 2025-06-09 10:48:23 | |||||||
StructureBoundary | Electric Zone | Protection Zone | 110 | 561 | Container | Restricted | 1 | 2025-06-09 10:48:23 | ||||
StructureBoundary | Electric Zone | Switching Zone | 110 | 562 | Container | Restricted | 1 | 2025-06-09 10:48:23 | ||||
StructureJunctionObject | Unknown | Unknown | 0 | 0 | 2025-06-09 10:47:40 | |||||||
StructureLine | Unknown | Unknown | 0 | 0 | 2025-06-09 10:47:40 | |||||||
StructureEdgeObject | Unknown | Unknown | 0 | 0 | 2025-06-09 10:47:40 | |||||||
ElectricTransmissionDevice | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 | |||||||
ElectricTransmissionDevice | High Voltage Generation | Unknown | 4 | 0 | Container | Restricted | 15 | E:Generation | 2025-06-09 10:48:28 | |||
ElectricTransmissionDevice | High Voltage Generation | Battery HV | 4 | 61 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Coal HV | 4 | 63 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Gas Turbine HV | 4 | 64 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Hydro HV | 4 | 66 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Nuclear HV | 4 | 67 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Photovoltaic Solar HV | 4 | 68 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Thermal Solar HV | 4 | 69 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Wind HV | 4 | 70 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Generator HV | 4 | 72 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Generation | Interconnect HV | 4 | 73 | Circuit Breaker Directional | Container | Restricted | 15 | E:Generation;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Service | Unknown | 9 | 0 | Container | Restricted | 15 | E:Load;E:Load - Commercial | 2025-06-09 10:48:28 | |||
ElectricTransmissionDevice | High Voltage Service | AC Metering HV | 9 | 161 | Container | Restricted | 15 | E:Load;E:Load - Commercial;E:Load - Industrial | 2025-06-09 10:48:28 | |||
ElectricTransmissionDevice | High Voltage Service | DC Metering HV | 9 | 162 | Container | Restricted | 15 | E:Load;E:Load - Commercial;E:Load - Industrial | 2025-06-09 10:48:28 | |||
ElectricTransmissionDevice | High Voltage Switch | Unknown | 10 | 0 | Container | Restricted | 15 | E:Switch | 2025-06-09 10:48:28 | |||
ElectricTransmissionDevice | High Voltage Switch | AC Circuit Breaker HV | 10 | 181 | Circuit Breaker | Container | Restricted | 15 | E:Switch;E:Switch - Circuit Breaker | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Switch | AC Disconnect HV | 10 | 182 | Simple Switch | Container | Restricted | 15 | E:Switch | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Switch | DC Circuit Breaker HV | 10 | 184 | Circuit Breaker | Container | Restricted | 15 | E:Switch;E:Switch - Circuit Breaker | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Switch | AC Bus Tie Breaker HV | 10 | 187 | Simple Switch | Container | Restricted | 15 | E:Switch | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Unknown | 11 | 0 | Container | Restricted | 15 | 2025-06-09 10:48:28 | ||||
ElectricTransmissionDevice | Power Transformer | DC Power - HV->HV | 11 | 203 | Two Winding | Container | Restricted | 15 | E:Transformer - Distribution Power;E:Transformer - Power;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station - HV->MV | 11 | 205 | Two Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Three Winding - HV->HV-HV | 11 | 206 | Three Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;E:Transformer - Step;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Three Winding - HV->HV-MV | 11 | 207 | Three Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;E:Transformer - Step;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Three Winding - HV->HV-LV | 11 | 209 | Three Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;E:Transformer - Step;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Step Up - MV->HV | 11 | 210 | Two Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;E:Transformer - Step;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Step - HV->HV | 11 | 211 | Two Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;E:Transformer - Step;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Three Winding - HV->MV-MV | 11 | 212 | Three Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | Power Transformer | Station Three Winding - HV->MV-LV | 11 | 213 | Three Winding | Container | Restricted | 15 | E:Station;E:Transformer - Distribution Power;E:Transformer - Power;Subnetwork Controller | 2025-06-09 10:48:28 | ||
ElectricTransmissionDevice | High Voltage Section Head | Unknown | 12 | 0 | 2025-06-09 10:48:28 | |||||||
ElectricTransmissionDevice | High Voltage Section Head | AC Section Head HV | 12 | 221 | Container | Restricted | 100 | 2025-06-09 10:48:28 | ||||
ElectricTransmissionDevice | High Voltage Section Head | DC Section Head HV | 12 | 222 | Container | Restricted | 10 | 2025-06-09 10:48:28 | ||||
ElectricTransmissionDevice | High Voltage Section Head | AC Tap HV | 12 | 223 | Container | Restricted | 10 | 2025-06-09 10:48:28 | ||||
ElectricTransmissionDevice | High Voltage Section Head | DC Tap HV | 12 | 224 | Container | Restricted | 10 | 2025-06-09 10:48:28 | ||||
ElectricTransmissionAssembly | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 | |||||||
ElectricTransmissionAssembly | High Voltage Bay | Unknown | 31 | 0 | 2025-06-09 10:48:34 | |||||||
ElectricTransmissionAssembly | High Voltage Bay | Capacitor | 31 | 91 | Container | Restricted | 15 | 2025-06-09 10:48:34 | ||||
ElectricTransmissionAssembly | High Voltage Bay | Regulator | 31 | 92 | Container | Restricted | 15 | 2025-06-09 10:48:34 | ||||
ElectricTransmissionAssembly | High Voltage Bay | Switch | 31 | 93 | Container | Restricted | 15 | 2025-06-09 10:48:34 | ||||
ElectricTransmissionAssembly | High Voltage Bay | Transformer | 31 | 94 | Container | Restricted | 15 | 2025-06-09 10:48:34 | ||||
ElectricTransmissionAssembly | High Voltage Bay | Metering | 31 | 95 | Container | Restricted | 15 | 2025-06-09 10:48:34 | ||||
ElectricTransmissionJunction | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 | |||||||
ElectricTransmissionJunction | High Voltage Attachment | Unknown | 1 | 0 | 2025-06-09 10:48:38 | |||||||
ElectricTransmissionJunction | High Voltage Attachment | AC Overhead HV | 1 | 1 | Container | Restricted | 75 | E:Cable - Overhead | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Attachment | AC Underground HV | 1 | 2 | Container | Restricted | 15 | E:Cable - Underground | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Attachment | DC Overhead HV | 1 | 3 | Container | Restricted | 75 | E:Cable - Overhead | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Attachment | DC Underground HV | 1 | 4 | Container | Restricted | 15 | E:Cable - Underground | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Attachment | AC Submersible HV | 1 | 7 | E:Cable - Underground | 2025-06-09 10:48:38 | ||||||
ElectricTransmissionJunction | High Voltage Attachment | DC Submersible HV | 1 | 8 | E:Cable - Underground | 2025-06-09 10:48:38 | ||||||
ElectricTransmissionJunction | High Voltage Connection Point | Unknown | 2 | 0 | 2025-06-09 10:48:38 | |||||||
ElectricTransmissionJunction | High Voltage Connection Point | AC Tap HV | 2 | 21 | Container | Restricted | 75 | E:Overhead Tap | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Connection Point | DC Tap HV | 2 | 23 | Container | Restricted | 75 | E:Overhead Tap | 2025-06-09 10:48:38 | |||
ElectricTransmissionJunction | High Voltage Connection Point | AC Busbar Tap HV | 2 | 24 | Container | Restricted | 15 | 2025-06-09 10:48:38 | ||||
ElectricTransmissionJunction | High Voltage Connection Point | DC Busbar Tap HV | 2 | 25 | Container | Restricted | 15 | 2025-06-09 10:48:38 | ||||
ElectricTransmissionJunction | High Voltage Connection Point | AC Bond Connection HV | 2 | 36 | 2025-06-09 10:48:38 | |||||||
ElectricTransmissionJunction | High Voltage Connection Point | DC Bond Connection HV | 2 | 37 | Container | Restricted | 15 | 2025-06-09 10:48:38 | ||||
ElectricTransmissionJunction | High Voltage Connection Point | AC Busbar Connection HV | 2 | 45 | Container | Restricted | 15 | 2025-06-09 10:48:38 | ||||
ElectricTransmissionJunction | High Voltage Connection Point | DC Busbar Connection HV | 2 | 46 | Container | Restricted | 15 | 2025-06-09 10:48:38 | ||||
ElectricTransmissionJunction | High Voltage Connection Point | Transmission Station HV | 2 | 47 | 2025-06-09 10:48:38 | |||||||
ElectricTransmissionJunctionObject | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 | |||||||
ElectricTransmissionLine | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 | |||||||
ElectricTransmissionLine | High Voltage Overhead Conductor | Unknown | 2 | 0 | 2025-06-09 10:48:44 | |||||||
ElectricTransmissionLine | High Voltage Overhead Conductor | AC Overhead HV | 2 | 20 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Overhead;E:Conductor | 2025-06-09 10:48:44 | |
ElectricTransmissionLine | High Voltage Overhead Conductor | DC Overhead HV | 2 | 23 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Overhead;E:Conductor | 2025-06-09 10:48:44 | |
ElectricTransmissionLine | High Voltage Underground Conductor | Unknown | 31 | 0 | 2025-06-09 10:48:44 | |||||||
ElectricTransmissionLine | High Voltage Underground Conductor | AC Underground HV | 31 | 22 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Underground;E:Conductor | 2025-06-09 10:48:44 | |
ElectricTransmissionLine | High Voltage Underground Conductor | DC Underground HV | 31 | 25 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Underground;E:Conductor | 2025-06-09 10:48:44 | |
ElectricTransmissionLine | High Voltage Submersible Conductor | Unknown | 32 | 0 | 2025-06-09 10:48:45 | |||||||
ElectricTransmissionLine | High Voltage Submersible Conductor | AC Submersible HV | 32 | 21 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Submersible;E:Conductor | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Submersible Conductor | DC Submersible HV | 32 | 24 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Cable - Submersible;E:Conductor | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Busbar | Unknown | 1 | 0 | 2025-06-09 10:48:45 | |||||||
ElectricTransmissionLine | High Voltage Busbar | AC Station Single Phase HV | 1 | 1 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Station | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Busbar | AC Station Three Phase HV | 1 | 2 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Station | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Busbar | DC Station HV | 1 | 3 | Container | Restricted | 100 | False | Any Vertex | E:Cable;E:Station | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Connector | Unknown | 3 | 0 | 2025-06-09 10:48:45 | |||||||
ElectricTransmissionLine | High Voltage Connector | AC Connector HV | 3 | 40 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Connector | DC Connector HV | 3 | 41 | Container | Restricted | 100 | False | Any Vertex | E:Cable | 2025-06-09 10:48:45 | |
ElectricTransmissionLine | High Voltage Service | Unknown | 15 | 0 | 2025-06-09 10:48:45 | |||||||
ElectricTransmissionLine | High Voltage Service | AC Overhead Service HV | 15 | 260 | Container | Restricted | 100 | False | E:Cable;E:Cable - Overhead | 2025-06-09 10:48:45 | ||
ElectricTransmissionLine | High Voltage Service | AC Underground Service HV | 15 | 261 | Container | Restricted | 100 | False | E:Cable;E:Cable - Underground | 2025-06-09 10:48:45 | ||
ElectricTransmissionLine | High Voltage Service | DC Overhead Service HV | 15 | 262 | Container | Restricted | 100 | False | E:Cable;E:Cable - Overhead | 2025-06-09 10:48:45 | ||
ElectricTransmissionLine | High Voltage Service | DC Underground Service HV | 15 | 263 | Container | Restricted | 100 | False | E:Cable;E:Cable - Underground | 2025-06-09 10:48:45 | ||
ElectricTransmissionLine | High Voltage Service | AC Submersible Service HV | 15 | 264 | Container | Restricted | 100 | False | E:Cable;E:Cable - Submersible | 2025-06-09 10:48:45 | ||
ElectricTransmissionLine | High Voltage Service | DC Submersible Service HV | 15 | 265 | Container | Restricted | 100 | False | E:Cable;E:Cable - Submersible | 2025-06-09 10:48:45 | ||
ElectricTransmissionEdgeObject | Unknown | Unknown | 0 | 0 | 2025-06-09 10:48:10 |
Category Name | Creation Time |
---|---|
Subnetwork Controller | 2025-06-09 10:47:38 |
Subnetwork Tap | 2025-06-09 10:47:38 |
Attribute Substitution | 2025-06-09 10:47:38 |
E:Cable | 2025-06-09 10:49:01 |
E:Cable - Overhead | 2025-06-09 10:49:01 |
E:Cable - Submersible | 2025-06-09 10:49:01 |
E:Cable - Underground | 2025-06-09 10:49:01 |
E:Conductor | 2025-06-09 10:49:01 |
E:Generation | 2025-06-09 10:49:01 |
E:Ground | 2025-06-09 10:49:01 |
E:Load | 2025-06-09 10:49:01 |
E:Load - Commercial | 2025-06-09 10:49:01 |
E:Load - Industrial | 2025-06-09 10:49:01 |
E:Overhead Tap | 2025-06-09 10:49:01 |
E:Station | 2025-06-09 10:49:01 |
E:Switch | 2025-06-09 10:49:01 |
E:Switch - Circuit Breaker | 2025-06-09 10:49:01 |
E:Transformer - Distribution Power | 2025-06-09 10:49:01 |
E:Transformer - Power | 2025-06-09 10:49:01 |
E:Transformer - Step | 2025-06-09 10:49:01 |
Configuration Name | Configuration ID | Traversability Model | Default | Creation Time |
---|---|---|---|---|
Single terminal | 0 | Bidirectional | All | 2025-06-09 10:47:38 |
Dual Terminal | 2 | Bidirectional | All | 2025-06-09 10:49:01 |
T-Blade Switch | 3 | Bidirectional | All | 2025-06-09 10:49:01 |
Two Winding | 4 | Directional | All | 2025-06-09 10:49:01 |
V-Blade Switch | 5 | Bidirectional | All | 2025-06-09 10:49:01 |
Inverter | 6 | Bidirectional | All | 2025-06-09 10:49:01 |
Rectifier | 7 | Bidirectional | All | 2025-06-09 10:49:01 |
Circuit Breaker | 8 | Bidirectional | All | 2025-06-09 10:49:01 |
Four Terminal Bypass Switch | 9 | Bidirectional | Closed | 2025-06-09 10:49:01 |
Voltage Regulator | 10 | Bidirectional | All | 2025-06-09 10:49:01 |
High Voltage Disconnect Switch | 11 | Bidirectional | All | 2025-06-09 10:49:01 |
High Voltage Inline Switch | 12 | Bidirectional | All | 2025-06-09 10:49:01 |
Relay | 13 | Bidirectional | All | 2025-06-09 10:49:01 |
Simple Switch | 14 | Bidirectional | All | 2025-06-09 10:49:01 |
SCADA Devices | 15 | Bidirectional | None | 2025-06-09 10:49:01 |
Three Winding | 16 | Directional | Primary to Both | 2025-06-09 10:49:01 |
E:SourceToLoad | 17 | Bidirectional | All | 2025-06-09 10:49:01 |
Circuit Breaker Directional | 18 | Directional | All | 2025-06-09 10:49:01 |
Two Winding Bidirectional | 19 | Bidirectional | All | 2025-06-09 10:49:01 |
Ground Switch | 20 | Bidirectional | All | 2025-06-09 10:49:01 |
Transformer Winding | 21 | Directional | All | 2025-06-09 10:49:01 |
Configuration Name | Terminal Name | Terminal ID | Upstream |
---|---|---|---|
Single terminal | Single Terminal | 1 | |
Dual Terminal | DT:Source | 2 | |
Dual Terminal | DT:Load | 3 | |
T-Blade Switch | T:Terminal A | 4 | |
T-Blade Switch | T:Terminal B | 5 | |
T-Blade Switch | T:Terminal C | 6 | |
Two Winding | 2wXFR:Primary | 7 | True |
Two Winding | 2wXFR:Secondary | 8 | False |
V-Blade Switch | V:Terminal A | 9 | |
V-Blade Switch | V:Terminal B | 10 | |
V-Blade Switch | V:Terminal C | 11 | |
Inverter | INV:DC Input | 12 | |
Inverter | INV:AC Output | 13 | |
Rectifier | RT:AC Input | 14 | |
Rectifier | RT:DC Output | 15 | |
Circuit Breaker | CB:Line Side | 16 | |
Circuit Breaker | CB:Bus Side | 17 | |
Four Terminal Bypass Switch | Bypass:Regulator Source | 18 | |
Four Terminal Bypass Switch | Bypass:Regulator Load | 19 | |
Four Terminal Bypass Switch | Bypass:Regulator In Bushing | 20 | |
Four Terminal Bypass Switch | Bypass:Regulator Out Bushing | 21 | |
Voltage Regulator | VR:In Bushing | 22 | |
Voltage Regulator | VR:Out Bushing | 23 | |
High Voltage Disconnect Switch | HVDS:Bus Side | 24 | |
High Voltage Disconnect Switch | HVDS:Line Side | 25 | |
High Voltage Inline Switch | HVIS:Terminal A | 26 | |
High Voltage Inline Switch | HVIS:Terminal B | 27 | |
Relay | RT:Measured Power | 28 | |
Relay | RT:Communications | 29 | |
Relay | RT:Aux Power | 30 | |
Simple Switch | SS:S1 | 31 | |
Simple Switch | SS:S2 | 32 | |
SCADA Devices | Power | 33 | |
SCADA Devices | Monitor | 34 | |
SCADA Devices | Communications | 35 | |
Three Winding | 3wXFR:Primary | 36 | True |
Three Winding | 3wXFR:Secondary | 37 | False |
Three Winding | 3wXFR:Tertiary | 38 | False |
E:SourceToLoad | Line Side | 39 | |
E:SourceToLoad | Load Side | 40 | |
Circuit Breaker Directional | CBD:Line Side | 41 | False |
Circuit Breaker Directional | CBD:Bus Side | 42 | True |
Two Winding Bidirectional | 2wXFRBD:Primary | 43 | |
Two Winding Bidirectional | 2wXFRBD:Secondary | 44 | |
Ground Switch | GS:Line Side | 45 | |
Ground Switch | GS:Ground Side | 46 | |
Transformer Winding | TW:Core | 47 | True |
Transformer Winding | TW:Bushing | 48 | False |
Configuration Name | Path Name | Path ID | Path Description |
---|---|---|---|
T-Blade Switch | All | 1 | All |
T-Blade Switch | B-C | 2 | T:Terminal B-T:Terminal C |
T-Blade Switch | A-B | 3 | T:Terminal A-T:Terminal B |
T-Blade Switch | A-C | 4 | T:Terminal A-T:Terminal C |
T-Blade Switch | None | 0 | None |
V-Blade Switch | All | 1 | All |
V-Blade Switch | B-C | 5 | V:Terminal B-V:Terminal C |
V-Blade Switch | A-C | 6 | V:Terminal A-V:Terminal C |
V-Blade Switch | Open | 0 | None |
V-Blade Switch | None | 0 | None |
Four Terminal Bypass Switch | Open | 7 | Bypass:Regulator Source-Bypass:Regulator Load |
Four Terminal Bypass Switch | None | 0 | None |
Four Terminal Bypass Switch | Closed | 8 | Bypass:Regulator Source-Bypass:Regulator In Bushing,Bypass:Regulator Out Bushing-Bypass:Regulator Load |
Relay | All | 1 | All |
Relay | None | 0 | None |
SCADA Devices | None | 0 | None |
SCADA Devices | All | 1 | All |
Three Winding | Primary to Both | 9 | 3wXFR:Primary-3wXFR:Secondary,3wXFR:Primary-3wXFR:Tertiary |
Three Winding | Primary to Secondary | 10 | 3wXFR:Primary-3wXFR:Secondary |
Three Winding | Primary to Tertiary | 11 | 3wXFR:Primary-3wXFR:Tertiary |
Three Winding | None | 0 | None |
Name | ID | Usage Type | Data Type | Field Type | Inline | Domain Name | Nullable | Apportionable | Substitution Attribute | Bit Position | Bit Size | Junction ID | Edge ID | Creation Time |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Source ID | 1 | Source ID | Integer | Short Integer | True | False | False | 0 | 7 | 1 | 2 | 2025-06-09 10:47:38 | ||
Terminal ID | 2 | Terminal ID | Integer | Short Integer | False | False | False | 7 | 0 | 3 | 4 | 2025-06-09 10:47:38 | ||
Asset group | 3 | Asset Group | Integer | Short Integer | True | False | False | 7 | 10 | 5 | 6 | 2025-06-09 10:47:38 | ||
Asset type | 4 | Asset Type | Integer | Short Integer | True | False | False | 17 | 10 | 7 | 8 | 2025-06-09 10:47:38 | ||
Is subnetwork controller | 5 | Is Subnetwork Controller | Integer | Short Integer | True | False | False | 27 | 1 | 9 | 10 | 2025-06-09 10:47:38 | ||
Tier name | 6 | Tier Name | Integer | Short Integer | True | False | False | 28 | 6 | 11 | 12 | 2025-06-09 10:47:38 | ||
Shape length | 7 | Shape Length | Double | Double | False | False | True | 34 | 0 | 13 | 14 | 2025-06-09 10:47:38 | ||
Position from | 8 | Position From | Double | Double | False | False | False | 34 | 0 | 15 | 16 | 2025-06-09 10:47:38 | ||
Position to | 9 | Position To | Double | Double | False | False | False | 34 | 0 | 17 | 18 | 2025-06-09 10:47:38 | ||
Flow direction | 10 | Flow Direction | Integer | Short Integer | True | False | False | 34 | 2 | 19 | 20 | 2025-06-09 10:47:38 | ||
Construction Status | 11 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 21 | 22 | 2025-06-09 10:49:01 | ||
E:Operating Status Normal | 12 | Unknown | Integer | Short Integer | True | Electric_Operating_Status | True | False | 36 | 2 | 23 | 24 | 2025-06-09 10:49:01 | |
E:Overhead Tap | 13 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 25 | 26 | 2025-06-09 10:49:01 | ||
E:Phases Normal | 14 | Unknown | Integer | Short Integer | False | False | False | 0 | 0 | 27 | 28 | 2025-06-09 10:49:01 | ||
E:Power | 15 | Unknown | Integer | Long Integer | False | True | False | 0 | 0 | 29 | 30 | 2025-06-09 10:49:01 | ||
E:Riser | 16 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 31 | 32 | 2025-06-09 10:49:01 | ||
E:Section Head | 17 | Unknown | Integer | Short Integer | False | True | False | 0 | 0 | 33 | 34 | 2025-06-09 10:49:01 | ||
Lifecycle Status | 18 | Unknown | Integer | Short Integer | True | Lifecycle_Status | False | False | 39 | 3 | 35 | 36 | 2025-06-09 10:49:01 | |
Measured Length | 19 | Unknown | Double | Double | False | True | True | 0 | 0 | 37 | 38 | 2025-06-09 10:49:01 |
Key | Value |
---|---|
Name | main.ServiceTerritory |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 5 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | ServiceTerritory |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | Shape |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 513599.84335675836 |
X-Max | 1245258.2409294248 |
Y-Min | 1569377.577809438 |
Y-Max | 2176057.330326773 |
Z-Min | 0.0004000000044470653 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {AD819E26-EF9A-421F-A021-3490EDFC5977} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The networks service territory that represents the operational area of the utility. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
COMPANYNAME | Company Name | String | True | 0 | 0 | 50 | True | False | The company name of this service area polygon | |||
GLOBALID | GlobalID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
DISTRICTNAME | District Name | String | True | 0 | 0 | 50 | True | False | The name of the district | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
Shape | Shape | Geometry | Index | True | 0 | 0 | 8 | True | True | |||
st_area(Shape) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(Shape) | Double | Length | True | 0 | 0 | 0 | False | True |
Key | Value |
---|---|
Name | main.StructureBoundary |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 38 |
Geometry Type | Polygon |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Boundary |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {2782ADEE-F75B-47E0-A5F4-79F5CD556C67} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Structure Boundary feature class represents features whose outline should be display on a map view or container view. Structure boundaries can contain structure edges, structure junctions, devices, lines, assemblies, and junctions. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
name | Name | String | True | 0 | 0 | 64 | True | False | The name of the facility, like a station name | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
powerunits | Maximum kW | Long Integer | True | 0 | 0 | 4 | True | False | The electrical units of measure used with this equipment, watts, volt amps,volt amps ractive | |||
devicecount | Contained Count | Short Integer | True | 0 | 0 | 2 | True | False | The number of features/objects contained in this feature | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True | |
st_area(SHAPE) | Double | Area | True | 0 | 0 | 0 | False | True | ||||
st_perimeter(SHAPE) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_38_VALIDATIO | False | True | VALIDATIONSTATUS |
GDB_38_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_40 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureBoundary_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the Structure Boundary feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Electric Substation Boundary | 102 | Electric Substation Boundary features are polygon features that outline of a Substation. |
Electric Zone | 110 | An electrical area that can be used for managing switching or saftey |
Key | Value |
---|---|
ID | 6 |
Minimum Client Version | 13.0 |
Evaluation Order | 1 |
Name | Invalid Geometry |
Description | All features need to have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = <Null>), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 7 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 8 |
Minimum Client Version | 12.7 |
Evaluation Order | 3 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 9 |
Minimum Client Version | 12.5 |
Evaluation Order | 4 |
Name | Unknown Subtype |
Description | A structure junction exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
ID | 10 |
Minimum Client Version | 12.5 |
Evaluation Order | 5 |
Name | Multipart |
Description | Multipart polygons are not allowed |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 223 |
Error Message | Part Count over maximum |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "12", "evaluationgoal", "is greater than", "partcountvaluelimit", "1", "partcountupperlimit", "-1", "partcountlowerlimit", "-1" ] } |
Script |
|
Key | Value |
---|---|
ID | 11 |
Minimum Client Version | 12.5 |
Evaluation Order | 6 |
Name | Duplicate Vertex |
Description | A duplicate vertex is within the allowable tolerance |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 181 |
Error Message | Duplicate Vertex Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:34 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "unit", "foot_us", "tolerance", "0.00328083333333333", "ReviewerRuleType", "8" ] } |
Script |
|
Key | Value |
---|---|
Name | main.StructureEdgeObject |
Dataset Type | Table |
Dataset ID | 40 |
Minimum Client Version | 13.2 |
Alias | Structure Edge Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {579B5106-ACA4-40AF-B597-5AEA1BB7815D} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Details | The Structure Edge object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial linear feature for locatability. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_40_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_42 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the Structure Edge Object class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection | |
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.StructureJunction |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 34 |
Geometry Type | Point |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Junction |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {6AE4D93F-D46A-48C9-AE61-F274F7500248} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Structure Junction feature class represents features which are tracked in a utility's asset inventory system. A structure junction can be either a structural feature that a device is attached to or a container of devices. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
height | height: Height, Platform Height, Pole Height | Short Integer | True | Wire_Pole_Height_Combined | 0 | 0 | 2 | True | False | The heighth of this structure | ||
treatment | treatment: Pole Treatment Type, Treatment Type | Short Integer | True | 0 | 0 | 2 | True | False | The method or material used to treat the structure | |||
equipmenttypeorclass | equipmenttypeorclass: Cabinet Type, Class, Manhole Type, Pole Class, Type, Vault Type | Short Integer | True | 0 | 0 | 2 | True | False | An extra attribute to futher define equipment type without adding an additional asset type | |||
indicatortypefield | Type of Marker | Short Integer | True | 0 | 0 | 2 | True | False | Describes the type of marker indicator, such as lighted | |||
grounded | Structure Grounded | Short Integer | True | Yes_No | 0 | 0 | 2 | True | False | Indicator that this structure is properly grounded | ||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
symbolrotation | Symbol Rotation | Double | True | 0 | 0 | 8 | True | False | The angle the symbol should be rotated by | |||
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_34_VALIDATIO | False | True | VALIDATIONSTATUS |
GDB_34_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_38 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureJunction_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Electric Station | 135 | A fence or gate surrounding critical facilities to maintain safety and security. |
Electric High Voltage Pole | 120 | Electric High Voltage Poles are vertical support structures used to support High Voltage or Transmission lines. Medium Voltage and Low Voltage equipment can be associated this feature type. |
Marker | 124 | Markers are types of structures used to warn of the location of power lines. These are frequently used for high voltage power lines or where medium voltage or higher voltage lines cross water bodies where boat booms could potentially come in contact with power lines. |
Key | Value |
---|---|
ID | 1 |
Minimum Client Version | 13.0 |
Evaluation Order | 1 |
Name | Invalid Geometry |
Description | All features need to have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = <Null>), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:32 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 2 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:32 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 3 |
Minimum Client Version | 12.7 |
Evaluation Order | 3 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:32 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 4 |
Minimum Client Version | 12.5 |
Evaluation Order | 4 |
Name | Unknown Subtype |
Description | A structure junction exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:32 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
ID | 5 |
Minimum Client Version | 12.7 |
Evaluation Order | 5 |
Name | Stacked Points |
Description | Stacked points in the structure junction are allowed in the Utility Network, but best practice is to avoid them. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 5 |
Error Number | 363 |
Error Message | Point intersects another point |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:33 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "featurestocompare", "main.StructureJunction", "comparefilters", "", "attributecomparison", "", "spatialrelation", "intersects", "customrelation", "", "tolerance", "0", "unit", "", "invertRelation", false, "ReviewerRuleType", "3", "primaryissecondary", true ] } |
Script |
|
Key | Value |
---|---|
Name | main.StructureJunctionObject |
Dataset Type | Table |
Dataset ID | 39 |
Minimum Client Version | 13.2 |
Alias | Structure Junction Object |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {D8F60E59-2C2B-45BF-8D2E-D463157174A2} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Details | The Structure Junction object class represents objects that participate in the structure model, but you do not desire to represent spatialy. They should be associated with a spatial point feature for locatability. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_39_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_41 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureJunction class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status |
Key | Value |
---|---|
Name | main.StructureLine |
Dataset Type | FeatureClass |
Feature Dataset | main.UtilityNetwork |
Dataset ID | 37 |
Geometry Type | Polyline |
Feature Type | Simple |
Z-Aware | True |
M-Aware | True |
Split Model | Update Insert |
Minimum Client Version | 13.2 |
Alias | Structure Line |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Shape Field | SHAPE |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
X-Min | 477016.923478125 |
X-Max | 1281841.160808058 |
Y-Min | 1539043.5901835714 |
Y-Max | 2206391.31795264 |
Z-Min | 0.0004000000044470653 |
Z-Max | 0.0004000000044470653 |
Catalog ID | {33B3EDFB-E924-43CA-836F-A5B7E0B97A6C} |
Class ID | {52353152-891A-11D0-BEC6-00805F7C4268} |
Details | The Structure Line contain lines which carry a resource. Structure lines participating as containers can contain other structure lines. |
Key | Value |
---|---|
utilityNetworkName | main.Network |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 8 | False | True | a unique, not null integer field used to uniquely identify rows in tables in a geodatabase | ||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | True | the main classification of a utility element | |
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | True | a class that refines a utility element's classification within an asset group | ||
ASSOCIATIONSTATUS | Association Status | Short Integer | False | Network_6_AssociationStatus | 0 | 0 | 0 | 2 | False | True | indicates the type of association a feature or object participates in | |
SUBNETWORKNAME | Supported subnetwork name | String | Index | False | Unknown | 0 | 0 | 2000 | False | True | ||
FLOWDIRECTION | Flow direction | Short Integer | True | Network_6_FlowDirection | 1 | 0 | 0 | 2 | True | True | ||
SHAPE | Shape | Geometry | Index | False | 0 | 0 | 8 | True | True | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
assetid | Asset ID | String | True | 0 | 0 | 64 | True | False | The Asset ID or Facilit ID of the equipment | |||
lifecyclestatus | Lifecycle Status | Short Integer | False | Lifecycle_Combined | 2 | 0 | 0 | 2 | True | False | The status of the feature in relation to tracing | |
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | The portal or dbms user that created the feature or object, per editor tracking | ||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | The date the object or feature was created per editor tracking | ||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | The last user to edit this feature according to editor tracking | ||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | The date this object or feature was last edited according to editor tracking | ||
constructionstatus | Construction Status | Short Integer | False | Construction_Status | 6 | 0 | 0 | 2 | True | False | Used to indicate if the eqiupment is Gang Operable and/or Phase Operable | |
VALIDATIONSTATUS | Validation status | Short Integer | Index | True | Validation Status | 6 | 0 | 0 | 2 | False | True | |
st_length(SHAPE) | Double | Length | True | 0 | 0 | 0 | False | True |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_37_VALIDATIO | False | True | VALIDATIONSTATUS |
GDB_37_SUBNETWOR | False | True | SUBNETWORKNAME |
UUID_39 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
st_spindex__StructureLine_SHAPE | True | True | SHAPE |
Name | Code | Details |
---|---|---|
Unknown | 0 | The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules and network properties applied to it. |
Subtype Name | Subtype Code | Field Name | Default Value | Domain Name | Details |
---|---|---|---|---|---|
Unknown | 0 | ASSETTYPE | 0 | Network_6_UnknownAssetType | |
Unknown | 0 | ASSOCIATIONSTATUS | 0 | Network_6_AssociationStatus | |
Unknown | 0 | SUBNETWORKNAME | Unknown | ||
Unknown | 0 | FLOWDIRECTION | 1 | Network_6_FlowDirection | |
Unknown | 0 | constructionstatus | 6 | Construction_Status | |
Unknown | 0 | lifecyclestatus | 2 | Lifecycle_Status | |
Unknown | 0 | VALIDATIONSTATUS | 6 | Validation Status |
Key | Value |
---|---|
ID | 12 |
Minimum Client Version | 13.0 |
Evaluation Order | 1 |
Name | Invalid Geometry |
Description | All features need to have a valid geometry. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 165 |
Error Message | Feature geometry has zero or no points, has nothing in the SHAPE field (SHAPE = <Null>), has empty envelope or is not simple |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "6" ] } |
Script |
|
Key | Value |
---|---|
ID | 13 |
Minimum Client Version | 12.7 |
Evaluation Order | 2 |
Name | Invalid Domain Value |
Description | Invalid domain values can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 3 |
Error Number | 202 |
Error Message | Domain Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ignoreattributes", "", "searchnullvalues", false, "ReviewerRuleType", "20" ] } |
Script |
|
Key | Value |
---|---|
ID | 14 |
Minimum Client Version | 12.7 |
Evaluation Order | 3 |
Name | Invalid Subtype |
Description | Invalid subtypes can affect feature selection and asset management |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 210 |
Error Message | Subtype Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "searchnullvalues", true, "ReviewerRuleType", "21" ] } |
Script |
|
Key | Value |
---|---|
ID | 15 |
Minimum Client Version | 12.5 |
Evaluation Order | 4 |
Name | Unknown Subtype |
Description | A structure line exists within the unknown subtype. For rules to function properly, everything must be assigned a known subtype. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 4 |
Error Number | 228 |
Error Message | Feature/Row matches |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "2", "QueryExpression", "ASSETGROUP = 0" ] } |
Script |
|
Key | Value |
---|---|
ID | 16 |
Minimum Client Version | 12.5 |
Evaluation Order | 5 |
Name | Multipart |
Description | Multipart lines cannot be traced through |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 223 |
Error Message | Part Count over maximum |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "12", "evaluationgoal", "is greater than", "partcountvaluelimit", "1", "partcountupperlimit", "-1", "partcountlowerlimit", "-1" ] } |
Script |
|
Key | Value |
---|---|
ID | 17 |
Minimum Client Version | 12.5 |
Evaluation Order | 6 |
Name | Self Closing Polyline |
Description | Polyline closes on itself. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 2 |
Error Number | 185 |
Error Message | Line/Polyline closes itself |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "ReviewerRuleType", "16", "searchgoal", "closed" ] } |
Script |
|
Key | Value |
---|---|
ID | 18 |
Minimum Client Version | 12.5 |
Evaluation Order | 7 |
Name | Cutback Greater Than 15 Degrees |
Description | Cutbacks are greater than 15 degrees indicating an digitizing error. |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 2 |
Error Number | 207 |
Error Message | Cutbacks Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "minimumangle", "15", "ReviewerRuleType", "0" ] } |
Script |
|
Key | Value |
---|---|
ID | 19 |
Minimum Client Version | 12.5 |
Evaluation Order | 8 |
Name | Duplicate Vertex |
Description | A duplicate vertex is within the allowable tolerance |
Type | Validation |
Batch | True |
Insert Trigger | False |
Update Trigger | False |
Delete Trigger | False |
Severity | 1 |
Error Number | 181 |
Error Message | Duplicate Vertex Error |
Enabled | True |
Exclude From Client | True |
Creation Time | 2025-06-09 10:49:38 |
Category | 9 |
Check Parameters | { "type": "PropertySet", "propertySetItems": [ "InputFilters", "", "unit", "foot_us", "tolerance", "0.00328083333333333", "ReviewerRuleType", "8" ] } |
Script |
|
Key | Value |
---|---|
Name | main.TransmissionConductorDetails |
Dataset Type | Table |
Dataset ID | 106 |
Minimum Client Version | 10.1 |
Alias | Transmission Conductor Details |
OID Field | OBJECTID |
GlobalID Field | GLOBALID |
Subtype Field | ASSETGROUP |
Default Subtype | Unknown |
Editor Tracking Enabled | True |
Editor Tracking UTC | True |
Creator Field | created_user |
Create Date Field | created_date |
Editor Field | last_edited_user |
Edit Date Field | last_edited_date |
Catalog ID | {12D6F5D6-E2AA-4524-97D9-E53D2B85049D} |
Class ID | {7A566981-C114-11D2-8A28-006097AFF44E} |
Name | Alias | Type | Usage | Nullable | Domain | Default Value | Precision | Scale | Length | Editable | Required | Details |
---|---|---|---|---|---|---|---|---|---|---|---|---|
OBJECTID | OBJECTID | OID | Index | False | 0 | 0 | 4 | False | True | |||
ASSETGROUP | Asset Group | Long Integer | Subtype | False | 0 | 0 | 0 | 4 | True | False | ||
ASSETTYPE | Asset Type | Short Integer | False | 0 | 0 | 0 | 2 | True | False | |||
GLOBALID | Global ID | Global ID | Index | False | 0 | 0 | 38 | False | True | |||
SUBNETWORKNAME | Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | |||
SUPPORTEDSUBNETWORKNAME | Supported Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | |||
SUPPORTINGSUBNETWORKNAME | Supporting Subnetwork Name | String | False | Unknown | 0 | 0 | 2000 | True | False | |||
phasesnormal | Phases Normal | Short Integer | False | 0 | 0 | 0 | 2 | True | False | |||
measuredlength | Measured Length | Double | True | 0 | 0 | 8 | True | False | ||||
insulationtype | Insulation Type | Short Integer | True | Electric_Wire_Insulation_Type | 0 | 0 | 2 | True | False | |||
wiretype | Wire Type | Short Integer | True | 0 | 0 | 2 | True | False | ||||
insulationmaxvoltage | Insulation Maximum Voltage | Long Integer | True | 0 | 0 | 4 | True | False | ||||
lifecyclestatus | Lifecycle Status | Short Integer | True | Lifecycle_Status | 2 | 0 | 0 | 2 | True | False | ||
impedance | Impedance | Double | True | 0 | 0 | 8 | True | False | ||||
temperaturerating | Temperature Rating | Double | True | 0 | 0 | 8 | True | False | ||||
wirenumber | Wire Number | Short Integer | True | 0 | 0 | 2 | True | False | ||||
kcmil | kcmil | Double | True | Electric_Wire_kcmil | 0 | 0 | 8 | True | False | |||
created_user | Created User | String | Creator | True | 0 | 0 | 255 | False | False | |||
created_date | Created Date | Date | Created | True | 0 | 0 | 8 | False | False | |||
last_edited_user | Last Edited User | String | Editor | True | 0 | 0 | 255 | False | False | |||
last_edited_date | Last Edited Date | Date | Edited | True | 0 | 0 | 8 | False | False | |||
nominalvoltagelinetoline | Nominal Voltage (L-L) | Long Integer | True | ElectricTransmission_Combined_Nominal_Voltage_LL | 0 | 0 | 4 | True | False | |||
maxvoltage | Maximum Voltage | Long Integer | True | ElectricTransmission_Combined_Maximum_Voltage | 0 | 0 | 4 | True | False | |||
maxoperatingvoltage | Maximum Operating Voltage | Long Integer | True | ELectricTransmission_High_Voltage_Maximumm_Operating_Voltage_LL | 0 | 0 | 4 | True | False | |||
cablegroupid | Cable Group Number | Short Integer | True | 0 | 0 | 2 | True | False | ||||
constructionstatus | Construction Status | Short Integer | True | Construction_Status | 6 | 0 | 0 | 2 | True | False | ||
assetid | Asset ID | String | True | 0 | 0 | 2000 | True | False | ||||
conductormaterial | Condutor Material | Short Integer | True | ElectricTransmission_Connector_Material | 0 | 0 | 2 | True | False | |||
conductorinsulationmaterial | Conductor Insulation Material | Short Integer | True | 0 | 0 | 2 | True | False | ||||
conductorsize | Conductor Diamter | Double | True | Electric_Wire_Diameter_in | 0 | 0 | 8 | True | False | |||
conductorfulldiameter | Conductor Full Diameter (in) | Double | True | 0 | 0 | 8 | True | False | ||||
conductorinsulationthickness | Conductor Insulation Thickness (in) | Double | True | 0 | 0 | 8 | True | False | ||||
conductorsheaththickness | Conductor Sheath Thickness (in) | Double | True | 0 | 0 | 8 | True | False | ||||
ElectricLineGLOBALID | GlobalID of the parent ElectricLine | GUID | Index | True | 0 | 0 | 38 | True | False |
Name | Is Unique | Is Ascending | Field Name |
---|---|---|---|
GDB_106_Electric | False | True | ElectricLineGLOBALID |
UUID_50 | True | True | GLOBALID |
FDO_OBJECTID | True | True | OBJECTID |
Name | Code | Details |
---|---|---|
Unknown | 0 | |
Aerial Bare | 101 | |
Aerial Covered | 102 | |
Busbar | 104 | |
Underground | 105 | |
Submarine | 108 |
Key | Value |
---|---|
Name | main.UtilityNetwork |
Dataset Type | FeatureDataset |
# of Children | 11 |
Spatial Reference | NAD_1983_StatePlane_Illinois_East_FIPS_1201_Feet;NAVD88_height_(ftUS) |
Name | Dataset Type | Feature Dataset | Dataset ID |
---|---|---|---|
main.ElectricTransmissionSubnetLine | FeatureClass | main.UtilityNetwork | 103 |
main.StructureBoundary | FeatureClass | main.UtilityNetwork | 38 |
main.StructureLine | FeatureClass | main.UtilityNetwork | 37 |
main.ElectricTransmissionDevice | FeatureClass | main.UtilityNetwork | 98 |
main.StructureJunction | FeatureClass | main.UtilityNetwork | 34 |
main.Network | UtilityNetwork | main.UtilityNetwork | 6 |
main.ElectricTransmissionLine_TransmissionConductorDetails | RelationshipClass | main.UtilityNetwork | 107 |
main.ElectricTransmissionAssembly | FeatureClass | main.UtilityNetwork | 101 |
main.ServiceTerritory | FeatureClass | main.UtilityNetwork | 5 |
main.ElectricTransmissionLine | FeatureClass | main.UtilityNetwork | 100 |
main.ElectricTransmissionJunction | FeatureClass | main.UtilityNetwork | 102 |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Conductor_Details_Busbar |
Description | Asset Types for Busbar |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
901 | High Voltage AC | |
902 | High Voltage DC | |
903 | Meduim Voltage | |
904 | Low Voltage AC | |
905 | Low Voltage DC |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | 104 | Busbar | assettype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Assembly_High_Voltage_Bay |
Description | Bay container |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
91 | Capacitor | |
92 | Regulator | |
93 | Switch | |
94 | Transformer | |
95 | Metering |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionAssembly | 31 | High Voltage Bay | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Device_High_Voltage_Generation |
Description | High Voltage Generation |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
61 | Battery HV | |
63 | Coal HV | |
64 | Gas Turbine HV | |
66 | Hydro HV | |
67 | Nuclear HV | |
68 | Photovoltaic Solar HV | |
69 | Thermal Solar HV | |
70 | Wind HV | |
72 | Generator HV | |
73 | Interconnect HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 4 | High Voltage Generation | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Device_High_Voltage_Section_Heads |
Description | Asset Types for High Voltage Section Heads |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
221 | AC Section Head HV | |
222 | DC Section Head HV | |
223 | AC Tap HV | |
224 | DC Tap HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 12 | High Voltage Section Head | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Device_High_Voltage_Service |
Description | High Voltage Service |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
161 | AC Metering HV | |
162 | DC Metering HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 9 | High Voltage Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Device_High_Voltage_Switch |
Description | High Voltage Switch |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
181 | AC Circuit Breaker HV | |
182 | AC Disconnect HV | |
184 | DC Circuit Breaker HV | |
187 | AC Bus Tie Breaker HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 10 | High Voltage Switch | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Device_High_Voltage_Transformer |
Description | High Voltage Transformer |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
203 | DC Power - HV->HV | |
205 | Station - HV->MV | |
206 | Station Three Winding - HV->HV-HV | |
207 | Station Three Winding - HV->HV-MV | |
209 | Station Three Winding - HV->HV-LV | |
210 | Station Step Up - MV->HV | |
211 | Station Step - HV->HV | |
212 | Station Three Winding - HV->MV-MV | |
213 | Station Three Winding - HV->MV-LV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 11 | Power Transformer | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Junction_High_Voltage_Attachment |
Description | High Voltage Attachment |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | AC Overhead HV | |
2 | AC Underground HV | |
3 | DC Overhead HV | |
4 | DC Underground HV | |
7 | AC Submersible HV | |
8 | DC Submersible HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionJunction | 1 | High Voltage Attachment | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Junction_High_Voltage_Connection_Point |
Description | High Voltage Connection Point |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 10 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
21 | AC Tap HV | |
23 | DC Tap HV | |
24 | AC Busbar Tap HV | |
25 | DC Busbar Tap HV | |
36 | AC Bond Connection HV | |
37 | DC Bond Connection HV | |
45 | AC Busbar Connection HV | |
46 | DC Busbar Connection HV | |
47 | Transmission Station HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionJunction | 2 | High Voltage Connection Point | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Busbar |
Description | High Voltage Busbar |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | AC Station Single Phase HV | |
2 | AC Station Three Phase HV | |
3 | DC Station HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 1 | High Voltage Busbar | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Connector |
Description | High Voltage Connector |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
40 | AC Connector HV | |
41 | DC Connector HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 3 | High Voltage Connector | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Overhead_Conductor |
Description | High Voltage Conductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
20 | AC Overhead HV | |
23 | DC Overhead HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 2 | High Voltage Overhead Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Service |
Description | High Voltage Service Lines |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
260 | AC Overhead Service HV | |
261 | AC Underground Service HV | |
262 | DC Overhead Service HV | |
263 | DC Underground Service HV | |
264 | AC Submersible Service HV | |
265 | DC Submersible Service HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 15 | High Voltage Service | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Submersible_Conductor |
Description | High VoltageSubmersibleConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
21 | AC Submersible HV | |
24 | DC Submersible HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 32 | High Voltage Submersible Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_ElectricTransmission_Line_High_Voltage_Underground_Conductor |
Description | High VoltageUndergroundConductor |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
22 | AC Underground HV | |
25 | DC Underground HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 31 | High Voltage Underground Conductor | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Boundary_Electric_Substation_Boundary |
Description | The Asset Types for the Electric Distribution Asset Group Substation Boundary |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A polygon used to define the outline of a station of unknown type |
82 | Distribution Substation | A polygon used to represent the location of a Distribution Substation |
83 | Transmission Substation | A polygon used to define the outline of a Transmission Substation |
84 | Transmission Switching Station | A polygon used to define the outline of a Transmission Switching station |
88 | Transmission Metering Station | |
89 | Transmission Terminal Station |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 102 | Electric Substation Boundary | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Boundary_Electric_Zone |
Description | Asset Types for Electric Zones |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A electrically connect group of equipment used for an unknown purpose |
561 | Protection Zone | A electrically connect group of equipment used in providing protection |
562 | Switching Zone | A electrically connect group of equipment used in switching a subsection of a circuit |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureBoundary | 110 | Electric Zone | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Electric_High_Voltage_Pole |
Description | The Asset Types for the Electric Distribution Asset Group High Voltage Pole |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Pole of Unknown type primarily used to support high voltage cables |
330 | Single Circuit Lattice HV | A Single Circuit Lattice structure primarily used to support high voltage cables |
331 | Dual Circuit Lattice HV | A Dual Circuit Lattice structure primarily used to support high voltage cables |
332 | Triple Circuit Lattice HV | A Triple Circuit Lattice structure primarily used to support high voltage cables |
333 | Quadruple Circuit Lattice HV | A Quadruple Circuit Lattice structure primarily used to support high voltage cables |
334 | Gantry HV | |
335 | H-Frame HV | |
337 | Pole HV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Electric_Station |
Description | Asset Types for Electric Stations |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | A Point representing the location of a Electric Station |
82 | Distribution Substation | A point used to represent the location of a Distribution Substation |
83 | Transmission Substation | A point representing the location of a Transmission Substation |
87 | Subtransmission Substation | A point representing the location of a Subtransmission Substation |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 135 | Electric Station | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Structure_Junction_Marker |
Description | Junctions used to represent markers in the Structure Network |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 7 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | Unknown type of Marker. |
461 | Aerial Marker | An aerial marker for overhead wires. |
462 | Buried Cable Marker | A location marker and warning for buried cables. |
463 | Overhead Water Crossing | A water crossing marker and warning for overhead cables over bodies of water. |
464 | Submerged Cable Marker | A marker used to indicate submerged cables at this location, typically found in large bodies of water. |
465 | Covered Marker | A location marker and warning for buried cables. |
466 | Terrain Marker | A surface marker used to make cables |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | ASSETTYPE |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Transmission_Conductor_Details_Aerial_Bare |
Description | Aerial Bare Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
901 | High Voltage AC | |
902 | High Voltage DC | |
903 | Meduim Voltage | |
906 | Static Wire |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | 101 | Aerial Bare | assettype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Transmission_Conductor_Details_Aerial_Covered |
Description | Asset Types for Aerial Covered Cable |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
901 | High Voltage AC | |
902 | High Voltage DC | |
903 | Meduim Voltage |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | 102 | Aerial Covered | assettype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Transmission_Conductor_Details_Submarine |
Description | Asset Types for Submarine |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
901 | High Voltage AC | |
902 | High Voltage DC | |
903 | Meduim Voltage | |
904 | Low Voltage AC | |
905 | Low Voltage DC |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | 108 | Submarine | assettype |
Key | Value |
---|---|
Owner | |
Domain Name | Asset_Type_Transmission_Conductor_Details_Underground |
Description | Asset Types for Underground |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
901 | High Voltage AC | |
902 | High Voltage DC | |
903 | Meduim Voltage | |
904 | Low Voltage AC | |
905 | Low Voltage DC |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | 105 | Underground | assettype |
Key | Value |
---|---|
Owner | |
Domain Name | Attribute Rule Type |
Description | The attribute rule type that created the error record. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Calculation | |
1 | Constraint | |
2 | Validation |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.GDB_ValidationObjectErrors | RuleType | ||
main.GDB_ValidationPointErrors | RuleType | ||
main.GDB_ValidationLineErrors | RuleType | ||
main.GDB_ValidationPolygonErrors | RuleType |
Key | Value |
---|---|
Owner | |
Domain Name | Construction_Status |
Description | Valid Construction statues for the assets |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 48 |
Code | Description | Details |
---|---|---|
0 | Warehouse | |
1 | Abandoned | |
2 | Removed | |
3 | Design | |
4 | Approved | |
5 | Under construction | |
6 | Construction complete | |
7 | Maintenance |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Combined_Bank_Power_Units |
Description | Combined domain for power units |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 161 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
30 | 30 A | |
60 | 60 A | |
100 | 100 A | |
200 | 200 A | |
250 | 250 A | |
300 | 300 A | |
350 | 350 A | |
400 | 400 A | |
450 | 450 A | |
500 | 0.5 kVA | |
600 | 600 A | |
750 | 0.75 kVA | |
900 | 900 A | |
1000 | 1000 A/1 kVA | |
1350 | 1350 A | |
1500 | 1.5 kVA | |
2000 | 2 kA/ 2 kVA | |
3000 | 3000 A/ 3 kVA | |
5000 | 5 kVA | |
7000 | 7 kVA | |
7500 | 7.5 kVA | |
10000 | 10 kVA | |
15000 | 15 kVA/ 15 kVAR | |
20000 | 20 kVA | |
30000 | 30 kVA | |
31500 | 31.5 kA | |
37500 | 37.5 kVA | |
38000 | 38 kVA | |
38100 | 38.1 kVA | |
40000 | 40 kA | |
45000 | 45 kVA | |
57000 | 57 kVA | |
57200 | 57.2 kVA | |
60000 | 60 kA | |
69000 | 69 kVA | |
72000 | 72 kVA | |
75000 | 75 kVA | |
76000 | 76 kVA | |
76200 | 76.2 kVA | |
80000 | 80 kA | |
90000 | 90 kA | |
112500 | 112.5 kVA | |
114000 | 114 kVA | |
114300 | 114.3 kVA | |
124800 | 124.8 kVA | |
138000 | 138 kVA | |
144000 | 144 kVA | |
152000 | 152 kVA | |
167000 | 167 kVA | |
171600 | 171.6 kVA | |
172500 | 172.5 kVA | |
207000 | 207 kVA | |
216000 | 216 kVA | |
219000 | 219 kVA | |
225000 | 225 kVA | |
228600 | 228.6 kVA | |
250000 | 250 kVA | |
276000 | 276 kVA | |
288000 | 288 kVA | |
332000 | 332 kVA | |
333000 | 333 kVA | |
342000 | 342 kVA | |
342900 | 342.9 kVA | |
345000 | 345 kVA | |
375000 | 375 kVA | |
414000 | 414 kVA | |
416000 | 416 kVA | |
432000 | 432 kVA | |
456000 | 456 kVA | |
500000 | 500 kVA | |
517500 | 517.5 kVA | |
518000 | 518 kVA | |
552000 | 552 kVA | |
576000 | 576 kVA | |
621000 | 621 kVA | |
657000 | 657 kVA | |
666000 | 666 kVA | |
667000 | 667 kVA | |
690000 | 690 kVA | |
700000 | 700 kVA | |
720000 | 720 kVA | |
750000 | 750 kVA | |
828000 | 828 kVA | |
833000 | 833 kVA | |
863000 | 863 kVA | |
864000 | 864 kVA | |
900000 | 900 kvar | |
966000 | 966 kVA | |
999000 | 999 kVA | |
1000000 | 1000 kVA | |
1035000 | 1035 kVA | |
1145000 | 1145 kVA | |
1242000 | 1242 kVA | |
1248000 | 1248 kVA | |
1250000 | 1250 kVA | |
1296000 | 1296 kVA | |
1500000 | 1500 kVA | |
1554000 | 1554 kVA | |
1656000 | 1656 kVA | |
1728000 | 1728 kVA | |
1750000 | 1750 kVA | |
2000000 | 2000 kVA | |
2001000 | 2001 kVA | |
2070000 | 2070 kVA | |
2100000 | 2100 kVA | |
2160000 | 2160 kVA | |
2499000 | 2499 kVA | |
2500000 | 2500 kVA | |
2589000 | 2589 kVA | |
3000000 | 3000 kVA | |
3462000 | 3462 kVA | |
3500000 | 3500 kVA | |
3750000 | 3750 kVA | |
4000000 | 4000 kVA | |
4250000 | 4250 kVA | |
4500000 | 4500 kVA | |
4750000 | 4750 kVA | |
5000000 | 5000 kVA | |
5500000 | 5.5 MVA | |
7000000 | 7000 kVA | |
7500000 | 7500 kVA | |
10000000 | 10 MVA/10000 kVA | |
12000000 | 12000 kVA/12 MVA | |
20000000 | 20 MVA | |
25000000 | 25 MVA | |
30000000 | 30 MVA | |
35000000 | 35 MVA | |
37500000 | 37.5 MVA | |
40000000 | 40 MVA | |
50000000 | 50 MVA | |
55000000 | 55 MVA | |
60000000 | 60 MVA | |
74000000 | 74 MVA | |
75000000 | 75 MVA | |
90000000 | 90 MVA | |
100000000 | 100 MVA | |
120000000 | 120 MVA | |
150000000 | 150 MVA | |
200000000 | 200 MVA | |
300000000 | 300 MVA | |
350000000 | 350 MVA | |
400000000 | 400 MVA | |
500000000 | 500 MVA | |
550000000 | 550 MVA | |
650000000 | 650 MVA | |
750000000 | 750 MVA | |
1000000000 | 1000 MVA | |
1200000000 | 1200 MVA | |
1500000000 | 1500 MVA | |
25000 | 25 kVA/ 25 kVAR | |
33000 | 33 kVAR | |
50000 | 50 kVA/50 kVAR | |
100000 | 100 kVA/100 kVAR | |
150000 | 150 kVA/150 kVAR | |
200000 | 200 kVA/200 kVAR | |
300000 | 300 kVA/300 kVAR | |
400000 | 400 kVA/400 kVAR | |
450000 | 450 kVA/450 kVAR | |
600000 | 600 kVA/600 kVAR | |
1200000 | 1200 kVA/1200 kVAR |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ground_Configuration |
Description | List of valid ground types for the distribution system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Grounded Wye | |
2 | Wye | |
3 | Delta | |
4 | Grounded Delta | |
5 | Direct Current |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ground_Configuration_Transformer_Regulator |
Description | Grounding type for transformers and regulators |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 5 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Grounded Wye | |
2 | Wye | |
3 | Delta | |
4 | Direct Current |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | secondarygrounding | ||
main.ElectricTransmissionDevice | tertiarygrounding | ||
main.ElectricTransmissionDevice | 11 | Power Transformer | secondarygrounding |
main.ElectricTransmissionDevice | 11 | Power Transformer | tertiarygrounding |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Marker_Type |
Description | Valid Marker Types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Buried | |
2 | Overhead Ball | |
3 | Lighted Overhead Ball | |
4 | Low Line | |
5 | Water Crossing |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | indicatortypefield |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Ohms_per_KM |
Description | Range domain of valid values for Electric Cable resistance per KM |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 4 |
Minimum | Maximum |
---|---|
0 | 999999 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionLine | 2 | High Voltage Overhead Conductor | ohm |
main.ElectricTransmissionLine | 31 | High Voltage Underground Conductor | ohm |
main.ElectricTransmissionLine | 32 | High Voltage Submersible Conductor | ohm |
main.ElectricTransmissionLine | 1 | High Voltage Busbar | ohm |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Operating_Status |
Description | Switchable Device Position |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Closed | |
1 | Open | |
2 | Open, Traceable |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | normaloperatingstatus | ||
main.ElectricTransmissionDevice | 0 | Unknown | normaloperatingstatus |
main.ElectricTransmissionDevice | 10 | High Voltage Switch | normaloperatingstatus |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Transmission_Phase_Attribution_All |
Description | All Valid Phase Descriptions |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 2 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | III or C or c | |
2 | II or B, or b | |
3 | III,II or BC or bc | |
4 | I or A,or a | |
5 | I,III or AC or ac | |
6 | I,II or AB or ab | |
7 | I,II,III or ABC or abc |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 0 | Unknown | phasesnormal |
main.ElectricTransmissionDevice | 12 | High Voltage Section Head | phasesnormal |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_Diameter_in |
Description | Wire diameter AWG size, stored as inches |
Field Type | Double |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 22 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
0.0641 | 14 | |
0.072 | 13 | |
0.0808 | 12 | |
0.0907 | 11 | |
0.1019 | 10 | |
0.1144 | 9 | |
0.1285 | 8 | |
0.1443 | 7 | |
0.162 | 6 | |
0.1819 | 5 | |
0.2043 | 4 | |
0.2294 | 3 | |
0.2576 | 2 | |
0.2893 | 1 | |
0.3249 | 0 | |
0.3648 | 00 | |
0.4096 | 000 | |
0.46 | 0000 | |
0.666 | 366 | |
0.792 | 477 | |
0.811 | 500 |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_Insulation_Type |
Description | Electric Wire Insulation Type |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Bare Wire | |
2 | Cross linked polyethylene | |
3 | Ethylene propylene rubber | |
4 | Paper insulated lead covered | |
5 | Polyethylene | |
6 | PVC | |
7 | Tree retardant cross linked polyethylene |
Key | Value |
---|---|
Owner | |
Domain Name | Electric_Wire_kcmil |
Description | Wire kcmil sizes |
Field Type | Double |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 7 |
Minimum | Maximum |
---|---|
250 | 4000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.TransmissionConductorDetails | kcmil | ||
main.TransmissionConductorDetails | 0 | Unknown | kcmil |
main.TransmissionConductorDetails | 101 | Aerial Bare | kcmil |
main.TransmissionConductorDetails | 102 | Aerial Covered | kcmil |
main.TransmissionConductorDetails | 104 | Busbar | kcmil |
main.TransmissionConductorDetails | 105 | Underground | kcmil |
main.TransmissionConductorDetails | 108 | Submarine | kcmil |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Combined_Maximum_Voltage |
Description | Combined Maximum Voltage Values |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 18 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
8000 | 8 kV | |
15000 | 15 kV | |
25000 | 25 kV | |
35000 | 35 kV | |
52000 | 52 kV | |
72500 | 72.5 kV | |
120000 | 120 kV | |
145000 | 145 kV | |
170000 | 170 kV | |
240000 | 240 kV | |
300000 | 300 kV | |
362000 | 362 kV | |
420000 | 420 kV | |
550000 | 550 kV | |
800000 | 800 kV | |
1100000 | 1.1 MV | |
1200000 | 1.2 MV |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Combined_Maximumm_Operating_Voltage_LL |
Description | Combined list of maximum operating voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 17 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
7200 | 7.2 kV | |
12000 | 12 kV | |
24000 | 24 kV | |
28000 | 28 kV | |
36000 | 36 kV | |
44000 | 44 kV | |
64000 | 64 kV | |
72500 | 72.5 kV | |
96000 | 96 kV | |
100000 | 100 kV | |
121000 | 121 kV | |
124000 | 124 kV | |
145000 | 145 kV | |
172000 | 172 kV | |
245000 | 245 kV | |
420000 | 420 kV |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | maxoperatingvoltage |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Combined_Nominal_Voltage_LG |
Description | Combined Line to Ground Nominal Voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 11 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
2400 | 2.4 kV | |
4800 | 4.8 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
12000 | 12 kV | |
13200 | 13.2 kV | |
14400 | 14.4 kV | |
19920 | 19.92 kV |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Combined_Nominal_Voltage_LL |
Description | Combined Line to Line Nominal Voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 75 |
# of Assignments | 15 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1000 | 1000 V | |
2400 | 2.4 kV | |
4160 | 4.16 kV | |
4800 | 4.8 kV | |
6900 | 6.9 kV | |
6930 | 6.93 kV | |
7200 | 7.2 kV | |
7620 | 7.62 kV | |
7970 | 7.97 kV | |
8320 | 8.32 kV | |
11000 | 11 kV | |
12000 | 12 kV | |
12470 | 12.47 kV | |
13200 | 13.2 kV | |
13800 | 13.8 kV | |
14400 | 14.4 kV | |
15000 | 15 kV | |
18000 | 18 kV | |
19920 | 19.92 kV | |
20780 | 20.78 kV | |
22860 | 22.86 kV | |
23000 | 23 kV | |
24940 | 24.94 kV | |
34500 | 34.5 kV | |
46000 | 46 kV | |
50000 | 50 kV | |
60000 | 60 kV | |
69000 | 69 kV | |
70000 | 70 kV | |
75000 | 75 kV | |
80000 | 80 kV | |
100000 | 100 kV | |
115000 | 115 kV | |
120000 | 120 kV | |
138000 | 138 kV | |
145000 | 145 kV | |
150000 | 150 kV | |
161000 | 161 kV | |
180000 | 180 kV | |
200000 | 200 kV | |
230000 | 230 kV | |
250000 | 250 kV | |
266000 | 266 kV | |
270000 | 270 kV | |
285000 | 285 kV | |
320000 | 320 kV | |
345000 | 345 kV | |
350000 | 350 kV | |
362000 | 362 kV | |
400000 | 400 kV | |
440000 | 440 kV | |
500000 | 500 kV | |
515000 | 515 kV | |
525000 | 525 kV | |
533000 | 533 kV | |
600000 | 600 kV | |
765000 | 765 kV | |
800000 | 800 kV | |
1000000 | 1 MV | |
1100000 | 1.1 MV | |
1200000 | 1.2 MV | |
1400000 | 1.4 MV | |
1500000 | 1.5 MV | |
1800000 | 1.8 MV | |
2500000 | 2.5 MV | |
3000000 | 3 MV | |
4000000 | 4 MV | |
5000000 | 5 MV | |
6000000 | 6 MV | |
6400000 | 6.4 MV | |
7200000 | 7.2 MV | |
8000000 | 8 MV | |
10000000 | 10 MV | |
12000000 | 12 MV |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Connector_Material |
Description | List of valid Connector Common Conductor Material |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 14 |
# of Assignments | 7 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1001 | ACSR | |
1002 | ACSR/AW | |
1003 | ACSR/TW | |
1004 | ACSS/AW | |
1005 | ACSS/TW | |
1006 | AAC | |
1007 | AAC/TW | |
1008 | AAAC | |
1009 | ACAR | |
1010 | Welded Aluminum Sheath | |
1011 | Copper Wires with Aluminum Sheath | |
1012 | Copper Wires with Copper Sheath | |
1013 | Copper Wires with Lead Sheath |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_High_Voltage_Generation_Range |
Description | |
Field Type | Long Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
5000000 | 5000000 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 4 | High Voltage Generation | peakload |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_High_Voltage_Maximum_Voltage |
Description | The maximum voltage, in kV |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 10 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
120000 | 120 kV | |
145000 | 145 kV | |
170000 | 170 kV | |
240000 | 240 kV | |
300000 | 300 kV | |
362000 | 362 kV | |
420000 | 420 kV | |
550000 | 550 kV | |
800000 | 800 kV | |
1100000 | 1100 kV | |
1200000 | 1200 kV |
Key | Value |
---|---|
Owner | |
Domain Name | ELectricTransmission_High_Voltage_Maximumm_Operating_Voltage_LL |
Description | List of High Voltage maximum voltages |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 18 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
100000 | 100 kV | |
121000 | 121 kV | |
124000 | 124 kV | |
145000 | 145 kV | |
172000 | 172 kV | |
245000 | 245 kV | |
420000 | 420 kV |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_High_Voltage_Nominal_Voltage |
Description | List of valid nominal voltages for high voltage |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 46 |
# of Assignments | 8 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
115000 | 115 kV | |
138000 | 138 kV | |
161000 | 161 kV | |
230000 | 230 kV | |
345000 | 345 kV | |
500000 | 500 kV | |
765000 | 765 kV | |
18000 | 18 kV | |
50000 | 50 kV | |
60000 | 60 kV | |
70000 | 70 kV | |
75000 | 75 kV | |
80000 | 80 kV | |
100000 | 100 kV | |
150000 | 150 kV | |
180000 | 180 kV | |
200000 | 200 kV | |
250000 | 250 kV | |
266000 | 266 kV | |
277000 | 277 kV | |
285000 | 285 kV | |
320000 | 320 kV | |
350000 | 350 kV | |
400000 | 400 kV | |
440000 | 440 kV | |
515000 | 515 kV | |
525000 | 525 kV | |
533000 | 533 kV | |
600000 | 600 kV | |
1000000 | 1 MV | |
1100000 | 1.1 MV | |
1200000 | 1.2 MV | |
1400000 | 1.4 MV | |
1500000 | 1.5 MV | |
1800000 | 1.8 MV | |
2500000 | 2.5 MV | |
3000000 | 3 MV | |
4000000 | 4 MV | |
5000000 | 5 MV | |
6000000 | 6 MV | |
6400000 | 6.4 MV | |
7200000 | 7.2 MV | |
8000000 | 8 MV | |
10000000 | 10 MV | |
12000000 | 12 MV |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_High_Voltage_Phase_Attribution |
Description | List of valid phase identifiers for the transmission system |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 14 |
Code | Description | Details |
---|---|---|
0 | De-Energized | |
1 | III | |
2 | II | |
3 | II,III | |
4 | I | |
5 | I,III | |
6 | I,II | |
7 | I,II,III |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_High_Voltage_Transformer_VA |
Description | List of valid High Voltage Transformer Power Rating |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 31 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
5500000 | 5.5 MVA | |
10000000 | 10 MVA | |
12000000 | 12 MVA | |
15000000 | 15 MVA | |
20000000 | 20 MVA | |
25000000 | 25 MVA | |
30000000 | 30 MVA | |
35000000 | 35 MVA | |
37500000 | 37.5 MVA | |
40000000 | 40 MVA | |
50000000 | 50 MVA | |
55000000 | 55 MVA | |
60000000 | 60 MVA | |
74000000 | 74 MVA | |
75000000 | 75 MVA | |
90000000 | 90 MVA | |
100000000 | 100 MVA | |
120000000 | 120 MVA | |
150000000 | 150 MVA | |
200000000 | 200 MVA | |
300000000 | 300 MVA | |
350000000 | 350 MVA | |
400000000 | 400 MVA | |
500000000 | 500 MVA | |
550000000 | 550 MVA | |
650000000 | 650 MVA | |
750000000 | 750 MVA | |
1000000000 | 1000 MVA | |
1200000000 | 1200 MVA | |
1500000000 | 1500 MVA |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionDevice | 11 | Power Transformer | ratedpower |
Key | Value |
---|---|
Owner | |
Domain Name | ElectricTransmission_Section_Indicator |
Description | Valid domain for Section Indicator |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 5 |
Code | Description | Details |
---|---|---|
1 | Start or End of Section |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Combined |
Description | Bitwise combination of lifecycle states for subnetwork management |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | Out of Service | |
1 | Proposed | |
2 | In Service | |
3 | Proposed and In Service | |
4 | Planned Removal | |
6 | In Service and Planned Removal |
Key | Value |
---|---|
Owner | |
Domain Name | Lifecycle_Status |
Description | Valid lifecycle states for the assets. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 4 |
# of Assignments | 39 |
Code | Description | Details |
---|---|---|
0 | Out of Service | |
1 | Proposed | |
2 | In Service | |
4 | Planned Removal |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_AssociationStatus |
Description | Indicates how the feature participates in associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 36 |
# of Assignments | 41 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Container | |
2 | Structure | |
4 | Content | |
5 | Content and Container | |
6 | Content and Structure | |
8 | Attachment | |
9 | Attachment and Container | |
10 | Attachment and Structure | |
12 | Attachment and Content | |
13 | Attachment and Content and Container | |
14 | Attachment and Content and Structure | |
16 | Visible Content | |
17 | Visible Content and Container | |
18 | Visible Content and Structure | |
24 | Visible Content and Attachment | |
25 | Visible Content and Attachment and Container | |
26 | Visible Content and Attachment and Structure | |
32 | Connectivity | |
33 | Connectivity and Container | |
34 | Connectivity and Structure | |
36 | Connectivity and Content | |
37 | Connectivity and Content and Container | |
38 | Connectivity and Content and Structure | |
40 | Connectivity and Attachment | |
41 | Connectivity and Attachment and Container | |
42 | Connectivity and Attachment and Structure | |
44 | Connectivity and Attachment and Content | |
45 | Connectivity and Attachment and Content and Container | |
46 | Connectivity and Attachment and Content and Structure | |
48 | Connectivity and Visible Content | |
49 | Connectivity and Visible Content and Container | |
50 | Connectivity and Visible Content and Structure | |
56 | Connectivity and Visible Content and Attachment | |
57 | Connectivity and Visible Content and Attachment and Container | |
58 | Connectivity and Visible Content and Attachment and Structure |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FeatureSourceID |
Description | The source feature class name in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 16 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Association | |
2 | System Junction | |
3 | System Junction Object | |
4 | Structure Junction | |
5 | Structure Line | |
6 | Structure Boundary | |
7 | Structure Junction Object | |
8 | Structure Edge Object | |
9 | Electric Transmission Device | |
10 | Electric Transmission Line | |
11 | Electric Transmission Assembly | |
12 | Electric Transmission Junction | |
13 | Electric Transmission Subnet Line | |
14 | Electric Transmission Junction Object | |
15 | Electric Transmission Edge Object |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_FlowDirection |
Description | Indicates how the feature flows in network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 14 |
Code | Description | Details |
---|---|---|
1 | With digitized | |
2 | Against digitized | |
3 | Indeterminate |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsConnected |
Description | Indicates if the feature is connected to a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 23 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True | |
2 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsContentVisible |
Description | Indicates if the content or attachment association is visible for containment associations. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDeleted |
Description | Indicates if a subnetwork has been marked for deletion. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsDirty |
Description | Indicates if a subnetwork is clean, dirty, or invalid. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | Clean | |
1 | Dirty | |
2 | Invalid |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.ElectricTransmissionSubnetLine | ISDIRTY | ||
main.ElectricTransmissionSubnetLine | 0 | Unknown | ISDIRTY |
main.ElectricTransmissionSubnetLine | 1 | Generation | ISDIRTY |
main.ElectricTransmissionSubnetLine | 2 | Transmission | ISDIRTY |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_IsSubnetworkController |
Description | Indicates if a device feature is a subnetwork controller. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TerminalNames |
Description | The terminal names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 49 |
# of Assignments | 16 |
Code | Description | Details |
---|---|---|
0 | None | |
1 | Single Terminal | |
2 | DT:Source | |
3 | DT:Load | |
4 | T:Terminal A | |
5 | T:Terminal B | |
6 | T:Terminal C | |
7 | 2wXFR:Primary | |
8 | 2wXFR:Secondary | |
9 | V:Terminal A | |
10 | V:Terminal B | |
11 | V:Terminal C | |
12 | INV:DC Input | |
13 | INV:AC Output | |
14 | RT:AC Input | |
15 | RT:DC Output | |
16 | CB:Line Side | |
17 | CB:Bus Side | |
18 | Bypass:Regulator Source | |
19 | Bypass:Regulator Load | |
20 | Bypass:Regulator In Bushing | |
21 | Bypass:Regulator Out Bushing | |
22 | VR:In Bushing | |
23 | VR:Out Bushing | |
24 | HVDS:Bus Side | |
25 | HVDS:Line Side | |
26 | HVIS:Terminal A | |
27 | HVIS:Terminal B | |
28 | RT:Measured Power | |
29 | RT:Communications | |
30 | RT:Aux Power | |
31 | SS:S1 | |
32 | SS:S2 | |
33 | Power | |
34 | Monitor | |
35 | Communications | |
36 | 3wXFR:Primary | |
37 | 3wXFR:Secondary | |
38 | 3wXFR:Tertiary | |
39 | Line Side | |
40 | Load Side | |
41 | CBD:Line Side | |
42 | CBD:Bus Side | |
43 | 2wXFRBD:Primary | |
44 | 2wXFRBD:Secondary | |
45 | GS:Line Side | |
46 | GS:Ground Side | |
47 | TW:Core | |
48 | TW:Bushing |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierName |
Description | The tier names in the utility network. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Generation | |
2 | Transmission |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_TierTopologyType |
Description | The type of topology for each tier. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 0 |
Code | Description | Details |
---|---|---|
1 | Radial | |
2 | Mesh |
Key | Value |
---|---|
Owner | |
Domain Name | Network_6_UnknownAssetType |
Description | The AssetType domain for the Unknown AssetGroup. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 1 |
# of Assignments | 11 |
Code | Description | Details |
---|---|---|
0 | Unknown |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Error Exception |
Description | Indicates if the error record has been marked as an exception. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
0 | False | |
1 | True |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.GDB_ValidationObjectErrors | IsException | ||
main.GDB_ValidationPointErrors | IsException | ||
main.GDB_ValidationLineErrors | IsException | ||
main.GDB_ValidationPolygonErrors | IsException |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Error Phase |
Description | Indicates error lifecycle phase of an error |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
2 | Review | |
4 | Correction | |
6 | Verification |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.GDB_ValidationObjectErrors | ErrorPhase | ||
main.GDB_ValidationPointErrors | ErrorPhase | ||
main.GDB_ValidationLineErrors | ErrorPhase | ||
main.GDB_ValidationPolygonErrors | ErrorPhase |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Error Status |
Description | Indicates error lifecycle status of an error |
Field Type | Long Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 6 |
# of Assignments | 4 |
Code | Description | Details |
---|---|---|
1 | Reviewed | |
2 | Resolved | |
3 | Mark As Exception | |
4 | Acceptable | |
6 | Unacceptable | |
9 | Exception |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.GDB_ValidationObjectErrors | ErrorStatus | ||
main.GDB_ValidationPointErrors | ErrorStatus | ||
main.GDB_ValidationLineErrors | ErrorStatus | ||
main.GDB_ValidationPolygonErrors | ErrorStatus |
Key | Value |
---|---|
Owner | |
Domain Name | Validation Status |
Description | The current record's validation status. |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Default Value |
Merge Policy | Default Value |
# of Codes | 8 |
# of Assignments | 32 |
Code | Description | Details |
---|---|---|
0 | No calculation required, no validation required, no error | |
1 | No calculation required, no validation required, has error(s) | |
2 | No calculation required, validation required, no error | |
3 | No calculation required, validation required, has error(s) | |
4 | Calculation required, no validation required, no error | |
5 | Calculation required, no validation required, has error(s) | |
6 | Calculation required, validation required, no error | |
7 | Calculation required, validation required, has error(s) |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Attachment_Height |
Description | Height of attachment |
Field Type | Short Integer |
Domain Type | Range |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | |
# of Assignments | 1 |
Minimum | Maximum |
---|---|
0 | 100 |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 124 | Marker | height |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Pole_Height_Combined |
Description | List of valid heights for all poles |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 22 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
25 | 25 Feet | |
30 | 30 Feet | |
35 | 35 Feet | |
40 | 40 Feet | |
45 | 45 Feet | |
50 | 50 Feet | |
55 | 55 Feet | |
60 | 60 Feet | |
65 | 65 Feet | |
70 | 70 Feet | |
75 | 75 Feet | |
80 | 80 Feet | |
85 | 85 Feet | |
90 | 90 Feet | |
95 | 95 Feet | |
100 | 100 Feet | |
105 | 105 Feet | |
110 | 110 Feet | |
115 | 115 Feet | |
120 | 120 Feet | |
125 | 125 Feet |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | height |
Key | Value |
---|---|
Owner | |
Domain Name | Wire_Structure_Junction_Pole_Treatment_Type |
Description | List of pole or tower treatment types |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 12 |
# of Assignments | 1 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Butt | |
2 | Natural | |
3 | Penta | |
4 | Creosote | |
5 | Chromated Copper Arsenates | |
6 | Chemonite | |
7 | Napthena | |
8 | Cellon | |
9 | Paint | |
10 | Copper Naphthenate | |
11 | Other |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | 120 | Electric High Voltage Pole | treatment |
Key | Value |
---|---|
Owner | |
Domain Name | Yes_No |
Description | Valid Yes, No values |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 3 |
# of Assignments | 3 |
Code | Description | Details |
---|---|---|
0 | Unknown | |
1 | Yes | |
2 | No |
Dataset | Subtype Code | Subtype Name | Field Name |
---|---|---|---|
main.StructureJunction | grounded | ||
main.StructureJunction | 135 | Electric Station | grounded |
main.StructureJunction | 120 | Electric High Voltage Pole | grounded |
Key | Value |
---|---|
Owner | |
Domain Name | Yes_No_Simple |
Description | Valid Yes, No values without unknown |
Field Type | Short Integer |
Domain Type | Coded Value |
Split Policy | Duplicate |
Merge Policy | Default Value |
# of Codes | 2 |
# of Assignments | 9 |
Code | Description | Details |
---|---|---|
0 | No | |
1 | Yes |